• Title/Summary/Keyword: 고정장치

Search Result 1,228, Processing Time 0.026 seconds

Three dimensional analysis of tooth movement using different types of maxillary molar distalization appliances (간접골성 고정원을 이용한 상악 구치부 원심이동 장치 종류에 따른 치아 이동 양상 평가)

  • Kim, Su-Jin;Chun, Youn-Sic;Jung, Sang-Hyuk;Park, Sun-Hyung
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.376-387
    • /
    • 2008
  • Objective: The purpose of this study was to compare the three dimensional changes of tooth movement using four different types of maxillary molar distalization appliances; pendulum appliance (PD), mini-implant supported pendulum appliance (MPD), stainless steel open coil spring (SP) and mini-implant supported stainless steel open coil spring (MSP). Methods: These experiments were performed using the Calorific $machine^{(R)}$ which can simulate dynamic tooth movement. Computed tomography (CT) images of the experimental model were taken before and after tooth movement in 1 mm thicknesses and reconstructed into a three dimensional model using V-works $4.0^{TM}$. These reconstructed images were superimposed using Rapidform $2004^{TM}$ and the direction and amount of tooth movement were measured. Results: The mean reciprocal anchor loss ratio at the first premolar was 17 - 19% for the PD and SP groups. The appliances using mini-implants (MPD or MSP) resulted in less anchorage loss (7 - 8%). On application of a pendulum appliance or MPD, distalization was obtained by tipping rather than by bodily movement. Furthermore, the maxillary second molar tipped distally and bucally. But on application of MSP, distalization was achieved almost by bodily movement. Conclusions: Regarding tooth movement patterns during molar distalization, stainless steel open coil spring with indirect skeletal anchorage was relatively superior to other methods.

Clinical Implementation of an Eye Fixing and Monitoring System with Head Mount Display (Head Mount Display (HMD)를 이용한 안구의 고정 및 감시장치의 임상사용 가능성 확인)

  • Ko, Young-Eun;Park, Seoung-HO;Yi, Byong-Yong;Ahn, Seung-Do;Lim, Sang-Wook;Lee, Sang-Wook;Shin, Seong-Soo;Kim, Jong-Hoon;Choi, Eun-Kyung;Noh, Young-Ju
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • A system to non-invasively fix and monitor eye by a head mounted display (HMD) with a CCD camera for stereotactic radiotherapy (SRS) of uveal melanoma has been developed and implemented clinically. The eye fixing and monitoring system consists of a HMD showing patient a screen for fixing eyeball, a CCD camera monitoring patient's eyeball, and an immobilization mask. At flrst, patient's head was immobilized with a mask. Then, patient was Instructed to wear HMD, to which CCD camera was attached, on the mask and see the given reference point on its screen. While patient stared at the given point in order to fix eyeball, the camera monitored Its motion. Four volunteers and one patient of uveal melanoma for SRS came into this study. For the volunteers, setup errors and the motion of eyeball were analyzed. For the patient, CT scans were peformed, with patient's wearing HMD and fixing the eye to the given point. To treat patient under the same condition, daily CT scans were also peformed before every treatment and the motion of lens was compared to the planning CT Setup errors for four volunteers were within 1mm and the motion of eyeball was fixed within the clinically acceptable ranges. For the patient with uveal melanoma, the motion of lens was fixed within 2mm from daily CT scans. An eye fixing and monitoring system allowed Immobilizing patient as well as monitoring eyeball and was successfully implemented in the treatment of uveal melanoma for SRS.

  • PDF

채석$\cdot$가공

  • 한국석재협회
    • 석재인
    • /
    • no.3
    • /
    • pp.5-5
    • /
    • 2003
  • 석물공장 '안전 사각지대' - 비멕, 외벽패널 고정장치 개발

  • PDF

Analysis of Biomechanical Responses for the Anterior Cervical Plate Fixation in relation to Bone Mineral Density (골밀도에 따른 전방 내고정 장치 시술 후 경추부의 생체역학적 거동에 대한 분석)

  • Shin, T. J.;Lee, S. J.;Shin, J. W.;Chang, H.
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.1
    • /
    • pp.69-80
    • /
    • 2001
  • 본 연구에서는 환자의 골다공증 유무에 따른 내고정 장치 시술 직후 및 융합 후의 안정성을 평가하기 위해 다양한 하중 모드에서 C5-C6 운동분절의 생체역학적 거동을 분석하였다. 이러한 목적으로 먼저, C5-C6 경추부의 유한요소 모델을 구현하여 검증하였다. 모델의 결과는 기존 실험치와 유사하여 신뢰성이 부여되었다. 검증된 모델은 Smith-Robinson 방식으로 골이식물을 삽입한 후 전방 내고정 장치를 적용한 시술 상황을 재현하기 위해 수정되었다. 수정된 모델은 두 종류로 구현되었다. (1) 첫 번째 모델에서는, 시술 직후의 상황을 재현하기 위해 골이식물과 종판의 경계면에 접촉요소를 사용하였다. (2)두 번째 모델에서는 완전히 융합된 상황을 나타내기 위해 골이식물을 종판에 고정하였다. 골다공증의 효과를 예측하기 위하여 두 모델의 해면골에 대한 탄성계수를 변화시켰다(정상: 100MPa, 골다공증: 40MPa). 각 모델의 C5 주체의 상위면에 73.6N의 압축 하중을 가한 후에 108Nm의 굴곡/신전, 굽힘, 비틀림 하중을 가하였으며, C6 추체의 하단면은 모든 방향에 대하여 구속하였다. 전체적인 결과에 있어서 상대적 회전운동, 미끄럼운동, 골이식물 내에서의 von Mises 응력의 경우 정상 모델에 비해 골다공증 모델에서 증가함을 보였으며, 특히 시술 직후의 모델에서 비틀림 하중이 가해진 경우, 상대적 회전운동 및 미끄럼 운동이 가장 높게 예측되었다. 이는 골다공증환자에게 전방 내고정 장치를 시술한 경우 골이식물의 파단 및 유합의 실패가 비틀림 하중에서 발생할 수 있음을 나타낸다. 해면골의 von Mises 응력은 시술 직후에 골다공증 모델의 모든 하중 모드에서, 유합 후에는 굽힘 하중 외의 모든 하중에서 ultimate strength를 초과하는 것으로 나타나 골다공증 환자에게 screw의 해리가 발생할 가능성이 높은 것으로 예측되었다. 따라서 골다공증 환자에게 과도한 운동이 발생하지 않도록 하기 위해서 시술 후 세심한 주의와 halo 같은 견고한 정형술이 필요할 것으로 사료된다.

  • PDF

Development of 200W Switchmode Power Supply for Precision Wire-cut Electric Discharge Machine (고정밀 와이어컷 방전가공기용 200W급 스위칭모드 전원장치 개발)

  • Jeong, In-Wha;Kim, Jong-Soo;Pavlovets, Mikhail V.;Lee, Hong-Sik;Rim, Geun-Hie;Lee, Byoung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.314-317
    • /
    • 2003
  • 높은 정밀도와 고품위 가공이 요구되는 금형제작 등에서 사용되는 고정밀 와이어컷 방전가공기가 고속, 고정밀 가공특성을 갖기 위해서는 무엇보다도 제어와 출력특성이 우수한 고성능의 전원장치가 필요하다. 본 논문에서는 고정밀 와이어컷 방전가공기용 스위칭모드 보조 전원장치로 사용되는 200W 280Vdc 영전압 포워드 컨버터 개발에 대해 기술하고 있다.

  • PDF

Dosimetric evaluation of using in-house BoS Frame Fixation Tool for the Head and Neck Cancer Patient (두경부암 환자의 양성자 치료 시 사용하는 자체 제작한 BoS Frame 고정장치의 선량학적 유용성 평가)

  • Kim, kwang suk;Jo, kwang hyun;Choi, byeon ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.35-46
    • /
    • 2016
  • Purpose : BoS(Base of Skull) Frame, the fixation tool which is used for the proton of brain cancer increases the lateral penumbra by increasing the airgap (the distance between patient and beam jet), due to the collision of the beam of the posterior oblique direction. Thus, we manufactured the fixation tool per se for improving the limits of BoS frame, and we'd like to evaluate the utility of the manufactured fixation tool throughout this study. Materials and Methods : We've selected the 3 patients of brain cancer who have received the proton therapy from our hospital, and also selected the 6 beam angles; for this, we've selected the beam angle of the posterior oblique direction. We' ve measured the planned BoS frame and the distance of Snout for each beam which are planned for the treatment of the patient using the BoS frame. After this, we've proceeded with the set-up that is above the location which was recommended by the manufacturer of the BoS frame, at the same beam angle of the same patient, by using our in-house Bos frame fixation tool. The set-up was above 21 cm toward the superior direction, compared to the situation when the BoS frame was only used with the basic couch. After that, we've stacked the snout to the BoS frame as much as possible, and measured the distance of snout. We've also measured the airgap, based on the gap of that snout distance; and we've proceeded the normalization based on each dose (100% of each dose), after that, we've conducted the comparative analysis of lateral penumbra. Moreover, we've established the treatment plan according to the changed airgap which has been transformed to the Raystation 5.0 proton therapy planning system, and we've conducted the comparative analysis of DVH(Dose Volume Histogram). Results : When comparing the result before using the in-house Bos frame fixation tool which was manufactured for each beam angle with the result after using the fixation tool, we could figure out that airgap than when not used in accordance with the use of the in-house Bos frame fixation tool was reduced by 5.4 cm ~ 15.4 cm, respectively angle. The reduced snout distance means the airgap. Lateral Penumbra could reduce left, right, 0.1 cm ~ 0.4 cm by an angle in accordance with decreasing the airgap while using each beam angle in-house Bos frame fixation tool. Due to the reduced lateral penumbra, Lt.eyeball, Lt.lens, Lt. hippocampus, Lt. cochlea, Rt. eyeball, Rt. lens, Rt. cochlea, Rt. hippocampus, stem that can be seen that the dose is decreased by 0 CGE ~ 4.4 CGE. Conclusion : It was possible to reduced the airgap by using our in-house Bos frame fixation tool for the proton therapy; as a result, it was possible to figure out that the lateral penumbra reduced. Moreover, it was also possible to check through the comparative analysis of the treatment plan that when we reduce the lateral penumbra, the reduction of the unnecessary irradiation for the normal tissues. Therefore, Using the posterior oblique the Brain cancer proton therapy should be preceded by decreasing the airgap, by using our in-house Bos frame fixation tool; also, the continuous efforts for reducing the airgap as much as possible for the proton therapy of other area will be necessary as well.

  • PDF

Development of a Fixed System for Socket (콘센트 고정기구 개발)

  • Cho, Byong-Hwan
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.607-608
    • /
    • 2012
  • 본 논문에서는 콘센트의 품질이나 기능이 비약적으로 발전하였으나, 기존 노출형 콘센트에 플러그를 연결하는 경우에 쉽게 빠지는 경우가 발생하거나, 콘센트와 플러그가 외부에 바로 노출되어 있어 먼지나 수분에 취약한 문제가 있어 그 해결책을 해결하고자 하였다. 콘센트와 플러그 사이에 콘센트 고정 장치를 결합하는 방법을 제시하고, 매입형 콘센트의 경우에도 고정 장치를 쉽게 결합하여 빠지는 현상을 방지하고, 먼지나 수분에 의한 감전사고 예방 효과를 누릴 수 있는 제품을 개발하고자 하였다.

  • PDF

Development of Mounting Device for Multi Aerial Sensor (항공용 멀티센서 고정 장치 개발)

  • Shin, Jin-Soo;Seol, Il-Hwan;Won, Jong-Hyeon
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2009.04a
    • /
    • pp.321-322
    • /
    • 2009
  • 항공기에 장착되어 1개 지점을 수직 및 경사각도로 5면에서 촬영하는 항공용 다각촬영 카메라를 비롯한 항공용 멀티센서는 항공기라는 공간상의 제약으로 인해 다양한 각도로 센서를 고정하기에 어려움이 있다. 또한 항공기 운항 중 기류변화등으로 인해 촬영예상 지역을 벗어나 촬영되기 쉽다. 이에 항공용 센서의 자세를 연직방향으로 유지 시켜주는 기존 항공용 마운트를 활용할 수 있으면서, 다양한 각도로 센서를 고정할 수 있는 장치를 개발하였다.

  • PDF

A study on correlation between open-close force and sensibility evaluation of child anchor cover (유아용 시트 고정 장치 커버의 개폐력과 감성평가와의 상관관계 연구)

  • Kim, Seong-Ju;Lee, Jong-Geol;Yu, Jong-Bong;Kim, Gi-Chan;Kim, Bong-Gyun;Kim, Hyeong-Seop
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2008.10a
    • /
    • pp.1-4
    • /
    • 2008
  • 본 연구는 유아용 시트 고정 장치 커버의 개폐 시 사용자가 느끼는 물리적 영향도와 감성적 영향도의 상관관계를 분석하여 주요설계인자와의 관계를 분석하고자 한다. 이를 위하여 커버의 형상이 각기 다른 차종을 선정, 주요설계인자에 대한 치수를 측정하고, 시험기를 이용하여 개폐 시 사용자에게 가해지는 물리적인 힘을 측정하였다. 또한, 감성평가 체크리스트를 통한 사용자의 감성평가도 실시하였으며, 감성평가의 기준은 힘평가(힘만 고려한 평가)와 감각평가(힘을 제외한 평가)로 분리하여 평가하였다. 정리하면 기계적으로 측정된 물리적 힘과 감성에 의한 힘평가의 결과값을 비교 분석하여 두 측정값의 상관관계를 분석하고자 하고, 또한 감성평가 중 힘평가와 감각평가 사이의 관계도를 분석하여 주요설계인자에 대해 어떠한 감성적 영향을 미치는 가를 알아보고자 한다. 최종적으로 유아용 시트 고정 장치의 최종 제품에 대해 감성을 고려한 설계인자를 제공하고자 한다.

  • PDF

Design of IR laser-based High-precision Automatic Focus Alignment (IR 레이저 기반 고정밀 자동 초점 정합장치 설계)

  • Jeon, Jae-Hwan;Kim, Myeong-Ho;Kim, Gwan-Hyung;Oh, Am-Suk
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2014.07a
    • /
    • pp.427-428
    • /
    • 2014
  • 화재발생 시 인명 안전을 위하여 초기의 화재감지가 매우 중요한 요인이다. 기존 연기감지기의 경우 일정한 조건만 맞으면 작동하기 때문에 비화재보의 우려가 높다. 특히 차량 매연도 연료가 연소되어 나오는 연기이므로 차량정체 시 트럭 등에서 발생하는 심한 매연에도 반응하여 오작동의 가능성이 높다. 이러한 기존 화재감지기의 문제점을 해결하기 위해 다양한 IR 레이저 기반 연기검출장치가 활용되고 있다. 하지만 IR 레이저 기반 연기검출장치는 100m 거리가 이격된 레이저 발광부와 수광부 구조에 따라 발광부 레이저광선의 각도변화에 따른 수광부 레이저 포인트 위치가 매우 민감하게 변화함에 따라 초기 레이저 포인트의 초점을 정확히 정합하고, 이후 보정하기 위한 고정밀 자동 초점 정합장치가 필요하다. 이에 본 논문에서는 레이저 투광부와 수광부를 분리하여 레이저 송신기, 수신기로 구성되는 고정밀 자동초점 정합장치를 설계하고자 한다.

  • PDF