• Title/Summary/Keyword: 고정장치

Search Result 1,231, Processing Time 0.035 seconds

A Simple Pseudo-Random Carrier Generation Technique by Fixed Frequency Carrier Composition (고정 주파수의 캐리어 합성을 통한 간단한 유사 랜덤 캐리어 발생기법)

  • Kim J. N.;Oh S. Y.;Jung Y. G.;Lim Y. C.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.420-424
    • /
    • 2004
  • 본 연구에서는 전력전자 변환장치에 적합한 고정주파수 캐리어 합성을 통한 간단한 유사 랜덤 발생기법을 제안하였다. 제안된 방법은 고정 주파수를 갖는 캐리어 C와 역상의 캐리어 $\bar{C}$ 를 랜덤하게 선택하여 유사 랜덤 캐리어를 발생한다. 랜덤 비트 발생기(PRBS)의 출력 상태에 따라 C와 $\bar{C}$가 랜덤하게 선택된다. 제안된 방법의 타당성을 검증하기 위하여 48v 단상 cascaded 5-레벨 인버터를 제작하였다. 실험 결과 고정 주파수의 캐리어 합성만으로 랜덤 주파수 캐리어를 간단하게 구현하였으며 전압 및 전류의 주파수의 광대역화를 실현할 수 있었다.

  • PDF

Design of Large 2-Axis Magnetic Fields Driving Apparatus for In Vivo Experiments (생체실험용 대형 2축 자기장 발생장치의 설계)

  • 성기연;김윤명
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.277-281
    • /
    • 2000
  • 본 논문에서 생체실험용 대형 2축 자기장 발생장치를 설계하였다. 생체실험 대상이 유동적이지 않고 홀더(holder)내에 고정될 경우 이는 방향성(orientation)의 논란이 불가피하며 이 영향을 줄이기 위해 각 축에 4개씩 총 8개의 코일을 사용하여 2축 4중코일 구조로 장치를 설계하였다. 원하는 특정 자기장에 대한 권선수 및 전류치를 결정하기 위해 정육면체 구조의 자기장 발생장치를 원통형으로 근사화시켜 간소하게 수식을 유도하였으며 각 코일의 최적위치 및 최적 권선비는 별도의 최적화 시뮬레이션을 통하여 수치를 추출하였다. 이렇게 얻어진 수치들을 MATLAB으로 제작한 시뮬레이터에 적용하여 설계 조건과 동일하게 모델링한 발생장치 주변에서의 자기장 분포를 시뮬레이션 해보았으며, 각 축에서의 균일도를 평가하여 균인 자기장 분포영역 또는 사용가능영역을 도출하였다. 장치해석 결과, 임의의 기준 자기장에 대해 약 5%의 오차범위를 인정할 경우, 최소 60% 이상의 사용가능영역을 확보할 수 있었으며, 이 영역 내에서는 고도의 균일 자기장이 분포함을 확인할 수 있었다.

  • PDF

A Study on the after-end ignition of composite solid propellant (I) (고체 추진기관의 후방점화에 대한 연구(I))

  • Suh, Hyuk;Choi, Young-Seok;Hong, Yoon-Taek
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.15-15
    • /
    • 1997
  • 본 연구는 전방점화 방식(the head-end ignition)을 채택하고 있는 composite 고체 추진기관(구룡 1모타)을 이용하여 후방점화 방식(the after-end ignition)에 의한 점화 가능성을 검토하였으며, 점화 방식 차이에 따른 추진기관의 초기 연소거동의 차이점을 고찰하고자 한 실험 연구로서, 후방 점화장치를 설계·제작하여 지상연소시험을 수행하였다. 점화장치는 착화장치(initiation system)와 에너지 방출장치(energy release system), 구조물(Hardware)로 구성되는데, 착화장치는 기존의 K2 squib를 사용하였고, 에너지 방출장치는 FRP튜브에 MTV pellet 점화제를 사용하였으며, 점화기를 후방에 부착시키는 방법으로는 flexible finger 형태의 locking sleeve를 설계하여 노즐목에 고정하였다.

  • PDF

3-D Conformal Radiotherapy for CNS Using CT Simulation (입체조준장치를 이용한 중추신경계의 방사선 입체조형치료 계획)

  • 추성실;조광환;이창걸
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.90-98
    • /
    • 2003
  • Purpose : A new virtual simulation technique for craniospinal irradiation (CSI) that uses a CT-simulator was developed to improve the accuracy of field and shielding placement as well as patient positioning. Materials and Methods : A CT simulator (CT-SIM) and a 3-D conformal radiation treatment planning system (3D-CRT) were used to develop CSI. The head and neck were immobilized with a thermoplastic mask while the rest of the body was immobilized with a Vac-Loc. A volumetric image was then obtained with the CT simulator. In order to improve the reproducibility of the setup, datum lines and points were marked on the head and body. Virtual fluoroscopy was performed with the removal of visual obstacles, such as the treatment table or immobilization devices. After virtual simulation, the treatment isocenters of each field were marked on the body and on the immobilization devices at the conventional simulation room. Each treatment fields was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR) and digitally composited radiography (DCR) images from virtual simulation. Port verification films from the first treatment were also compared with the DRR/DCR images for geometric verification. Results : We successfully performed virtual simulations on 11 CSI patients by CT-SIM. It took less than 20 minutes to affix the immobilization devices and to obtain the volumetric images of the entire body. In the absence of the patient, virtual simulation of all fields took 20 min. The DRRs were in agreement with simulation films to within 5 mm. This not only reducee inconveniences to the patients, but also eliminated position-shift variables attendant during the long conventional simulation process. In addition, by obtaining CT volumetric image, critical organs, such as the eyes and the spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. Differences between the DRRs and the portal films were less than 3 m in the vertebral contour. Conclusion : Our analysis showed that CT simulation of craniospinal fields was accurate. In addition, CT simulation reduced the duration of the patient's immobility. During the planning process. This technique can improve accuracy in field placement and shielding by using three-dimensional CT-aided localization of critical and target structures. Overall, it has improved staff efficiency and resource utilization by standard protocol for craniospinal irradiation.

  • PDF

The Implementation of a Fixed Grid File on the Hand-held Storage (휴대저장장치에서 고정그리드파일의 구현)

  • Kim, Dong Hyun;Ban, Chae Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.313-315
    • /
    • 2013
  • Hand-held devices such as smart phones exploit flash memory based storages to store data for processing jobs. Since the flash memory, non-volatile memory, is able to store mass data, it is required to use the index for processing queries. However, the flash memory has the shortcomings that it does not support the overwrite operation and its write operation is very slow. In this paper, we build the fixed grid file, one of the multi-dimensional spatial index, on a flash memory and evaluate the performance test.

  • PDF