Dynamic Response Analysis of Pneumatic Floating Breakwater Mounted Wave-power Generation System of Oscillating Water Column (진동수주형 파력발전시스템을 탑재한 공기주입식 부유식방파제의 동적거동해석)

  • Lee, Kwang-Ho;Kim, Do-Sam;Jung, Ik-Han
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.6
    • /
    • pp.305-314
    • /
    • 2017
  • Ocean wave energy harvesting is still too expensive despite developing a variety of wave energy converter (WEC) devices. For the cost-effective wave energy harvesting, it can be an effective measure to use existing breakwaters or newly installed breakwaters for both wave control and energy harvesting purposes. In this study, we investigated the functionality of both breakwater and wave-power generator for the oscillating water column (OWC)-type wave energy converter (WEC) installed in a pneumatic floating breakwater, which was originally developed as a floating breakwater. In order to verify the performance of the breakwater as a WEC, the air flow velocity from air-chamber to WEC has to be evaluated properly. Therefore, air flow velocity, wave transformation and motion of floating structure was numerically implemented based on BEM from linear velocity potential theory without considering the compressibility of air within the chamber. Air pressure, meanwhile, was assumed to be fluctuated by the motions of structure and the water level change within air-chamber. The validity of the obtained values can be determined by comparing the previous results from the numerical analysis for different shapes. Based on numerical model results, wave transformation characteristics around OWC system mounted on the fixed and floating breakwaters, and motions of the structure with air flow velocities are investigated. In summary, all numerical results are almost identical to the previous research considering air compressibility. Therefore, it can be concluded that this analysis not considering air compressibility in the air chamber is more efficient and practical method.

Mean viscous drift forces on a fixed vertical cylinder in waves and currents (파랑과 조류에 의한 고정된 수직 실린더 구조물에 작용하는 평균 점성 표류력)

  • Shin, Dong Min;Kim, Yuncheol;Moon, Byung Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.521-527
    • /
    • 2020
  • In offshore structures, the mean viscous drift force due to drag is considered to be a design part that has not been considered until recently. In particular, it is most important to calculate the drift force acting on a vertical cylinder considering both waves and currents in the low frequency region. This paper presents a process for deriving analytical solutions for the drift forces acting on a fixed vertical cylinder considering waves and currents. The area of the cylinder was considered by dividing it into a splash zone above the free surface and a submerged zone below the free surface. The presence of waves is considered only in the Splash Zone, and in the case of waves and currents, the equations were obtained for both the splash and submerged zones. The results show that drift forces occur due to the significant viscous effects in both the splash zone and the submerged zone. Therefore, the analytical solutions derived in this study can be used to calculate the drift force using the given design variables and form a theoretical basis for judging whether the magnitude of the drift force in each case has a dominant influence within a specific physical range.

CFD Application to Evaluation of Wave and Current Loads on Fixed Cylindrical Substructure for Ocean Wind Turbine (해상풍력발전용 고정식 원형 하부구조물에 작용하는 파랑 및 조류 하중 해석을 위한 CFD 기법의 적용)

  • Park, Yeon-Seok;Chen, Zheng-Shou;Kim, Wu-Joan
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.7-14
    • /
    • 2011
  • Numerical simulations were performed for the evaluation of wave and current loads on a fixed cylindrical substructure model for an ocean wind turbine using the ANSYS-CFX package. The numerical wave tank was actualized by specifying the velocity at the inlet and applying momentum loss as a wave damper at the end of the wave tank. The Volume-Of-Fluid (VOF) scheme was adopted to capture the air-water interface. An accuracy validation of the numerical wave tank with a truncated vertical circular cylinder was accomplished by comparing the CFD results with Morison's formula, experimental results, and potential flow solutions using the higher-order boundary element method (HOBEM). A parametric study was carried out by alternately varying the length and amplitude of the wave. As a meaningful engineering application, in the present study, three kinds of conditions were considered, i.e., cases with current, waves, and a combination of current and progressive waves, passing through a cylindrical substructure model. It was found that the CFD results showed reasonable agreement with the results of the HOBEM and Morison's formula when only progressive waves were considered. However, when a current was included, CFD gave a smaller load than Morison's formula.

The Influence of Suction Foundation Models for Offshore Wind Turbine (해상풍력발전 석션기초의 강성산정 방법에 따른 영향 분석)

  • Jang, Hwa Sub;Nam, Hyun Woo;Kwak, Yeon Min;Yoon, Se Woong;Kim, Ho Sun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.5
    • /
    • pp.339-344
    • /
    • 2015
  • Suction piles have been widely used as foundations and anchor systems in offshore industry, and recently, it have been tried to be used as foundations for offshore wind turbines. Many researches have shown that stiffness of a foundation could effect dynamic responses of a offshore wind turbine so that appropriate modeling application of wind turbine foundations is recommended. In this paper, we calculate a stiffness matrix of a suction foundation through 3D FEM analysis and compare the results with the ones calculated by conventional formula for estimating stiffness of shallow foundations. And then we carry out integrated load analysis for the evaluation of dynamic responses and natural frequencies of the structure using the calculated stiffness matrix. The results shows that the effect of load in the mudline is not large, but in the case of assuming the foundation as a fixed support, the natural frequency is over-estimated up to 10%. Therefore, considering stiffness of foundations is recommended when you evaluate the natural frequencies of wind turbine structures.

Seismic Soil-Structure Interaction Analyses of LNG Storage Tanks Depending on Foundation Type (기초 형식에 따른 LNG 저장탱크의 지반-구조물 상호작용을 고려한 지진응답 분석)

  • Son, Il-Min;Kim, Jae-Min;Lee, Changho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.3
    • /
    • pp.155-164
    • /
    • 2019
  • In this study, the soil-structure interaction(SSI) effect on the seismic response of LNG storage tanks was investigated according to the type of foundation. For this purpose, a typical of LNG storage tank with a diameter of 71m, which is constructed on a 30m thick clay layer over bedrock was selected, and nonlinearity of the soil was taken into account by the equivalent linearization method. Four different types of foundations including shallow foundation, piled raft foundation, and pile foundations(surface and floating types) were considered. In addition, the effect of soil compaction in group piles on seismic response of the tank was investigated. The KIESSI-3D, which is a SSI analysis package in the frequency domain, was used for the SSI analysis. Stresses in the outer tank, and base shear and overturning moment in the inner tank were calculated. From the comparisons, the following conclusions could be made: (1) Conventional fixed base seismic responses of outer tank and inner tank can be much larger than those of considering the SSI effect; (2) The influence of SSI on the dynamic response of the inner tank and the outer tank depends on the foundation types; and (3) Change in the seismic response of the structure by soil compaction in the piled raft foundation is about 10% and its effect is not negligible in the seismic design of the structure.

Performance of Oscillating Water Column type Wave Energy Converter in Oblique Waves (사파중 진동수주형 파력발전장치의 성능평가)

  • Jin, Jiyuan;Hyun, Beom-Soo;Hong, Keyyong;Liu, Zhen
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.3
    • /
    • pp.182-188
    • /
    • 2014
  • In an oscillating water column (OWC)-type wave energy conversion system, the performance of the OWC chamber depends on the chamber shape, as well as the incident wave direction and pressure drop produced by the turbine. Although the previous studies on OWC chambers have focused on wave absorbing performance in ideal operating conditions, incident waves do not always arrive normally to the OWC chamber in real sea conditions, especially in fixed devices. The present study deals with experiments and numerical calculations to investigate the effects of wave direction on the performance of the OWC chamber. The experiments were carried out in a three-dimensional wave basin for five different wave directions, including the effect of turbine using the corresponding orifice. The wave elevation inside the chamber was measured at the center point under various incident wave conditions. The numerical study was conducted by using a numerical wave tank-based volume-of-fluid model to compare the results with experimental data and to reveal the detailed flows around the chamber.