• Title/Summary/Keyword: 고정성

Search Result 6,261, Processing Time 0.03 seconds

Modified resin-bonded fixed partial dentures utilizing tooth undercuts: a clinical case study (서로 다른 삽입로를 이용한 최소 삭제 접착성 고정성 보철물의 임상 연구)

  • Doh, Re-Mee;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.106-113
    • /
    • 2011
  • The object of this clinical study was to evaluate the short-term outcome of modified resin-bonded fixed partial dentures which utilizes the original tooth undercuts and different path of insertion of components. Materials and methods: 71 units of modified RBFPDs that were used in 21 patients at the Department of Prosthodontics, College of Dentistry, Yonsei University were evaluated. The follow-up period was up to 25 months, the mean being 7 months. Survival rate, mobility, percussion, probing depth, bleeding on probing, plaque index was recorded and radiographs were taken to monitor alveolar bone loss. Results & Conclusion: Within the limits of this short term retrospective study, it was concluded that: 1. No mechanical failure such as debonding or fracture of the framework was found during the follow-up period. 2. The periodontal apparatus was stable and no clinical change was observed after prosthetic treatment. 3. No significant marginal bone loss was found in the radiographic evaluation.

Effects of Gender-stereotype Activation in Men's and Women's Self-construal (성 고정관념 활성화가 남녀의 자아해석에 미치는 영향)

  • Hee Jeong Bang ;Hyeja Cho
    • Korean Journal of Culture and Social Issue
    • /
    • v.10 no.1
    • /
    • pp.83-106
    • /
    • 2004
  • This study was conducted to explore how men's and women's self-construals do change according to gender-stereotype activation. The results showed that men have stronger gender-stereotypes and construe self more gender-stereotypic way than women. In general, women showed having less gender-stereotype but they construed self more stereotypic way. And the stereotype activation affected only on women to construe self less stereotypic way. Both men and women do accept physical appearance stereotypes more than other domains of gender-stereotype when they construe their selves. Gender-role stereotypes are more accepted by men than women, and gender-stereotypes of ability are more accepted by men but refused by women when stereotype was activated. And men accepted prescriptive gender-stereotype more than women. People of high gender-stereotype group construe self more stereotypic way than those of low stereotype group. But in low gender-stereotype group, women construe self less stereotypic way when stereotype is activated than when not. These results are taken to show, among others, that self-stereotyping of targets were different depending on whether the targets are man or woman, and that self stereotyping of an individual contributes to build a mechanism of maintaining gender-stereotype of a society to which he or she belongs.

  • PDF

The Fixation Effects of Biological specimen Using Microwave Oven Equipped With Infrared-Temperature Sensor (적외선 온도감응기를 장착한 마이크로파 오븐의 생체물질 고정효과)

  • 신길상
    • The Korean Journal of Zoology
    • /
    • v.37 no.2
    • /
    • pp.144-155
    • /
    • 1994
  • 마이크로파 에너지로서 현미경 관찰을 위한 생체물질을 고정할 때, 고정효과는 화학 고정액을 사용할 때와 비교하여 보다 우수한 또는 적어도 동일한 고정효과를 볼 수 있다는 것은 알려진 사실이다. 그러나 기존의 마이크로파 오븐을 사용하여 생체물질을 고정하면 고정 정도에 일정성이 없는데, 이는 마이크로파가 균일하게 조사되지 않고 고정에 적절하도록 마이크로팍의 강도를 조절하기 어려우며, 이로 인하여 정확한 고정온도의 측정이 불가능하기 때문으로 생각된다. 이 연구에서는 마이크로파가 조사되는 동안 시료의 온도를 측정할 수 없는 기존의 마이크연.파 오븐의 단점을 보완하기 위하여 비접촉식 적외선 온도 감응기를 장착한 마이크로파 오븐을 개발하였으며 고정효과를 관찰하기 위하여는 포유류의 기준 조직으로 알려진 생쥐의 신장을 고정하였다 고정효과는 전체적인 구조와 세부 구조의 보존이 모두 우수하였고 최적의 고정온도는 28$\pm$1$^{\circ}C$(완충용액 20 ml, 10초) 이었다. 이와같이 고정된 재료는 고정효과 뿐만 아니라 염색성이 좋아서 조직화학 반응이 우수하고, 냉동절편법과 연계했을 때 전체 절편제작 과정이 2~4시간 내에 완료될 수 있었다 이때 절편의 질(질)은 화학 고정액이나 냉동절편 법에 의하여 제작된 것 보다 우수하였다.

  • PDF

Clinical Evaluation of Implant-Supported Fixed Prostheses (임플란트-지지 고정성 보철물의 임상적 상태에 대한 평가)

  • Park, Chan-Yong;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Jeon, Yeong-Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.317-326
    • /
    • 2013
  • This study was to compare the cumulative survival rate of implant-supported fixed prostheses and to analyze association between risk factors and cumulative survival rate of implant-supported fixed prostheses. In order to assess the clinical status of implant-supported fixed prostheses, individuals who treated in the Department of Prosthodontics, Pusan National University Dental Hospital, between 2000 to 2007 were examined. The results of this study were as follows: 1. Length of service of implant-supported fixed prostheses was $6.6{\pm}32.0$ years (mean), 11.7 years (median). 2. Age and sex of patient was found to have no statistically significant influence on longevity of implant-supported fixed prostheses (P>.05). 3. Reason of tooth extraction wax found to have statistically significant influence on implant-supported fixed prostheses (P<.05). The longevity of fixed prostheses was low in tooth extraction case due to periodontal disease (median:9.0 years). 4. Location of implant-supported fixed prostheses was found to have statistically significant influence on longevity of fixed prostheses (P<.05). The longevity of fixed prostheses was low in molar region (median:8.8 years). 5. Number of units in implant-supported fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 6. Condition of opposing dentition was found to have no statistically significant influence on longevity of implant-supported fixed prostheses (P>.05). 7. Food impaction (40.5%), porcelain fracture (25.8%), screw loosening (23.6%) were frequent complications.

Complication and Failure Analysis of Fixed Restorations (고정성 보철물과 연관된 합병증과 실패에 관한 조사)

  • Yun, Mi-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.149-159
    • /
    • 2011
  • Restoring and replacing teeth with fixed prostheses commonly used in dental practice. Because of improper oral hygiene care and inaccurate laboratory procedure, complication of fixed prostheses was found in the mouth of patient. Although many efforts have been continually made to obtain the data of long term prognosis of fixed prostheses, it was difficult to do it. The purpose of this study was to evaluate the clinical status of fixed prostheses to improve the quality of dental care. In order to assess the clinical status of fixed prostheses, a total of 154 individuals (aged 22-82, 88 women and 66 men loaded with 578 unit of fixed prostheses, and 423 abutments) who visited the Department of Prosthodontics, Pusan National University Hospital, between January 2009 to December 2009 and removed old fixed prostheses were examined. The results of this study were as follows: 1. Length of service of fixed prostheses was $10.3{\pm}05.5$ years (mean), 10.0 years (median). 2. Location of fixed prostheses was found to have statistically significant influence on longevity of fixed prostheses (P<.05). The longevity of fixed prostheses was high in anterior-posterior combination region (mean:13.1, median:13.5) than anterior and posterior region. 3. Longevity of fixed prostheses made of metal was longest (mean:13.3, median:12.3). 4. Number of units in fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 5. Condition of opposing dentition was found to have statistically significant influence on longevity of fixed prostheses (P>.05). The fixed prostheses lasted longest when opposed by complete denture (mean:17.1, median:19.7), removable partial denture, fixed prosthesis and natural dentition trailing behind (P<.05) 6. Periodontal disease (37.5%), dental caries (19.0%), defective margin (18.4%) were frequent complications. In 33.1% of the cases, abutment state after removing fixed prostheses was needed to be extracted.

A Study on how to Utilize the DR System using Assistive Devices (보조기구를 이용한 DR System 활용 방법에 대한 연구)

  • Seon-Yeol, Seo;Jeong-Ho, Kim;Jin-Ok, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.115-122
    • /
    • 2023
  • The hip joint device is an important immobilization device for internal rotation in the diagnosis of bone density test, microfracture, and arthritis. These fixing mechanisms have limitations in maintaining reproducibility due to the use of Velcro. In this study, we developed an improved hip joint device and evaluated its usefulness. For 30 students enrolled in the Department of Radiology, we evaluated the reproducibility through medical imaging and the time required for positioning by applying the conventionaling and improved device. Changes over time were also evaluated. As a result, compared to the conventional device, the improved device showed a 32% reduction in positioning time and improved reproducibility by about 6.2 times. As for the amount of change over time, the positioning time increased in the conventional device, but decreased in the improved device, and the reproducibility of the conventional device was lower than that of the improved device. Through this, it can be said that the use of the improved device improved the image quality and reduced the radiologist's workload.

Restoration of bilateral distal extension removable partial denture using a fixed implant prosthesis in unilateral partial edentulous patient: A case report (하악 편측 소수치 잔존 환자에서 임플란트 고정성 보철물을 사용하여 양측성 후방 연장 국소의치로 수복: 증례보고)

  • Kee, Wonjin;Park, Jae-Ho;Lim, Hyun-Pil;Yun, Kwi-Dug;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.176-181
    • /
    • 2019
  • Traditional removable partial denture is a successful treatment for partial edentulous patients. When the abutment is formed with unilateral minority teeth, satisfaction with the use of removable partial denture may be lowered due to patient's discomfort and damage of the abutment. Recently, it has been reported that the unilateral posterior extension partial denture is used as a bilateral posterior extension partial denture using implant fixed prostheses as abutments. In this case, by using implant surveyed crown prostheses, bilateral posterior extension partial denture is fabricated in site that is predicted to have a poor prognosis. This resulted in improved support, maintenance, and stabilization of the removable partial denture, which were economically beneficial to patient and satisfied with use.

Marginal fit of three-unit zirconia anterior fixed dental prostheses fabricated using CAD/CAM and MAD/MAM system (CAD/CAM과 MAD/MAM 시스템으로 제작된 3-unit 지르코니아 고정성 국소의치의 변연 적합도에 관한 연구)

  • Song, Tae-Jin;Yeo, In-Sung;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.145-151
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the marginal fit of three-unit zirconia fixed dental prostheses (FDPs) fabricated using CAD/CAM and MAD/MAM system. Materials and methods: Dentiform maxillary central and lateral incisor were prepared for 3-unit FDP and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, fifteen 3-unit FDPs were fabricated. Metal-ceramic group was three-unit metal-ceramic FDPs, $Everest^{(R)}$ group was zirconia three-unit FDPs fabricated using the $Everest^{(R)}$ system (Kavo Dental GmbH, Biberach, Germany) and $Rainbow^{TM}$ group was zirconia three-unit FDPs fabricated using the $Rainbow^{TM}$ system (Dentium Co. Inc., Seoul, South Korea). They were cemented to resin dies with adhesive resin cement. After removing pontics, each retainers were separated and observed under measuring machine (Presize 440C) and analyzed through one-way ANOVA and Duncan test (${\alpha}$ = .05). Results: Mean values and standard deviations of marginal gap dimensions in each group for three-unit FDPs were $78.5{\pm}11.05\;{\mu}m$ for the metal-ceramic group, $59.30{\pm}11.63\;{\mu}m$ for the $Everest^{(R)}$ group and $70.34{\pm}13.98\;{\mu}m$ for the $Rainbow^{TM}$ group. Conclusion: 1. The $Everest^{(R)}$ group in comparison with metal-ceramic group showed better marginal fit, which had significant differences P<.05. 2. The mean marginal gap values between $Everest^{(R)}$ and $Rainbow^{TM}$ group did not showed significant differences (P>.05). 3. The mean marginal gap values between $Rainbow^{TM}$ group and metal-ceramic group did not showed significant differences (P>.05). 4. The mean marginal gaps of each group were within clinically acceptable range ($120\;{\mu}m$).

A Study on Gender Differences of Gender-Role Stereotype among Youth (청소년 성역할 고정관념에 관한 연구 - 성 차이를 중심으로 -)

  • Kim, So-joung
    • Korean Journal of Social Welfare Studies
    • /
    • no.36
    • /
    • pp.129-149
    • /
    • 2008
  • This study examined gender differences of gender-role stereotype among Korean youth. Specifically, the contribution of youth's individual traits and parental background factors were tested. Data came from Korea Youth Panel Survey 2005. Analysis methods were t-test and regression analysis. The major findings of this study are as follows. First, the boys exhibited higher scorers on gender-role stereotype than the girls. Second, both boys and girls acquired higher masculine gender-role stereotype than feminine. Third, self-esteem, age, and mother's education influenced significantly boys' masculine and feminine gender-role stereotype. And self-esteem, age, mother's education, father's education and family structure influenced significantly girls' masculine and feminine gender-role stereotype, but mother's work status and income level did not. The limitations and implications of the findings from this study were discussed with respect to further studies.