A Study on Development of Alternative Non-aqueous Cleaning Agents to Ozone Depletion Substances and its Field Application (오존파괴물질 대체 비수계세정제 개발 및 현장 적용 연구)

  • Park, Yong-Bae;Bae, Jae-Heum;Lee, Min-Jae;Lee, Jong-Gi;Lee, Ho-Yeoul;Bae, Soo-Jung;Lee, Dong-Kee
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.306-313
    • /
    • 2011
  • Flux or solder is used in soldering process for manufacturing electronic parts such as printed circuit boards (PCB). After soldering process, residual flux and solder paste on the parts should be removed since their residuals could cause performance degradation or failure of parts due to their corrosion and electric leakage. Ozone depletion substances such as 1,1,1- trichloroethane (TCE) and HCFC-141b have widely been using for removal of residual flux and solder paste after soldering process In manufacturing of electronic parts until now. In this study, non-aqueous cleaning agents without flash point were developed and applied to industrial field for replacement of cleaning agents with ozone depletion. In order to develop non-aqueous cleaning agents without ethers, esters, fluoride- type solvents. And their physical properties and cleaning abilities were evaluated, and they were applied to industrial fields for cleaning of flux and solder on the PCB. And vacuum distillation apparatus were operated to determine their operating conditions and recycling yields for recycling of used cleaning agents formulated in this study. As a result of physical properties measurement of our formulated cleaning agents, they were expected to have good wetting and penetrating power since their surface tensions were relatively low as 18.0~20.4 dyne/$cm^2$ and their wetting indices are relatively large. And some cleaning agents holding fluoride-type solvents as their components did not have any flash point and they seemed to be safe in their handling and storage. The cleaning experimental results showed that some cleaning agents were better in their cleaning of flux and solder paste than 1,1,1-TCE and HCFC-141b. And industrial application results of the formulated cleaning agents for cleaning PCB indicated that they can be applicable to industry due to their good cleaning capability in comparison with HCFC-141b. The recycling experiments of the used formulated cleaning agents through a vacuum distillation apparatus also showed that their 91.9~97.5% could be recycled with its proper operating conditions.

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Power generation and Stream - Results of the Precision Monitoring (바이오가스 이용 기술지침 마련을 위한 연구(II) - 정밀모니터링 결과 중심으로)

  • Moon, HeeSung;Bae, Jisu;Park, Hoyeun;Jeon, Taewan;Lee, Younggi;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.1
    • /
    • pp.65-78
    • /
    • 2018
  • According to the in social aspects such as population growth, urbanization and industrialization, development of livestock industry by meat consumption, amount of organic wastes (containing sewage sludge and food waste, animal manure, etc) has been increased annually in South Korea. Precise monitoring of 11 organic wastes biogas facilities were conducted. The organic decomposition rate of organic wastewater was 68.2 % for food wastes, 66.8 % for animal manure and 46.2 % for sewage sludge and 58.8 % for total organic wastes. As a result of analyzing the biogas characteristics before and after the pretreatment, the total average of the whole facility was measured to be 560 ppm using iron salts and desulfurization, and decreased to 40 ppm when the reduction efficiency was above 90 %. Particularly, when iron salt is injected into the digester, the treatment efficiency is about 93 %, and the average is reduced to 150 ppm. In the case of dehumidification, the absolute humidity and the relative humidity were analyzed. The dew point temperature of the facility where the dehumidification facility was well maintained as $14^{\circ}C$, the absolute humidity was $12.6g/m^3$, and the relative humidity was 35 %. Therefore, it is necessary to compensate for the disadvantages of biogasification facilities of organic waste resources and optimize utilization of biogas and improve operation of facilities. This study was conducted to optimize biogas utilization of type of organic waste(containing sewage sludge and food waste, animal manure) through precision monitoring.

A Study on the Place Identity on the Vicinity of Sangsosan and Government Office of Buan-hyun by Letters Carved on the Rocks (바위글씨로 본 부안 관아와 상소산 일대의 장소정체성)

  • Rho, Jae-Hyun;Kim, Jeong-Moon;Lee, Hyun-Woo;Lee, Jung-Han;Kim, Dae-Soo
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.2
    • /
    • pp.142-154
    • /
    • 2012
  • This study aimed at learning the characteristics of place identity of the Buan county hall garden and Sangsosan(上蘇山) by looking over the pattern and content of letter-engraved rocks and nearby facilities and history. Especially, we focused on the meaning and contents of the letters in Sangsosan and a Government Office of Buan engraved on rocks in order to learn what the place means. The results of our study are as follows. Buan-hyun(扶安縣) in the Joseon dynasty period blossomed literary culture of enjoying poetry and melody, and this was faithful realization of the concept of "Rakto(樂土)" of 'Saengubuan(生居扶安).' The grand scale letters written by Si-SooPark(朴蓍壽: 1767~1876), head of the office in the early 19th century, in the cursive style on the basis stone of the garden of Buan county building, which was the site of the office of Buan-hyun in the Joseon dynasty period, such as 'Bongraedongcheon(蓬萊洞天)', 'Jurim(珠林)', and 'Okcheon(玉泉)' mean that "'Bongrae', the another name of Buan', is a place where Taoist hermits would live because the spring water of Seorim flows down to be Okcheon.", showing his pride of living Buan. The regions like Seorimjeong, Geumdae(琴臺), and Hyecheon(惠泉) where letters engraved on rocks are located intensively are closely related with those who communicated with Mae-ChangLee(李梅窓: 1573~1610), the slave of the government, and are local attractions and garden traces where the literary culture and scholar's spirit of Buan are well-harmonized. Most of the letters were written from the 19th century to the early 20th century, showing that 4 for landscapes, 8 for Kyungseck(景色: imaginary scenry), 5 for figures, 15 for poems and 2 for others. The ratio of poems is much higher than that of poems in other regions' letters on rocks, and the keyword of the letters is Haecheon. A piece of the place identity heavily influenced by the Taois thermit ideology is revealed by the expressions of 'Bongraedongcheon', 'Sosansaho(蘇山四皓)' or 'the spring water of Haecheon' that was considered as an elixir of Taoist hermits. Seorim the forest, which had been managed after Yeon-Myeong Cho(趙然明: 1797~?), head of the office, planted trees in the 11th year of the reign of King Heonjong(1845), Seorimjeong in the forest, and rocks with engraved letters on them are proof of literary culture and the garden traces showing the characteristics and aspect of Imcheon(林泉) Garden of the office heavily influenced by the Taoist hermit ideology. Along with Naebyeon-san national park and Kyeokpo region, the center of Buan tourism, we hope that cultural heritages including rocks with engraved letters over Seorim park would become a representative cultural heritage and attraction of Buan.

Relationship Between Airway Inflammation Assessed by Induced Sputum and Airway Hyperresponsiveness in Asthmatic Patient (기관지천식 환자에서 유도객담으로 평가한 기도염증과 기관지 과민성과의 관계)

  • Chung, Lee-Young;Kim, Hyun-Jin;Jeong, Gyeong-Won;Kang, Mi-Jeong;Kim, Hwi-Jong;Chung, Hyo-Young;Lee, Jong-Deog;Hwang, Young-Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.4
    • /
    • pp.517-524
    • /
    • 1999
  • Background : Airway inflammation and hyperresponsiveness are recognized as major characteristics of bronchial asthma. Airway inflammation has usually been assessed by invasive methods, e.g. BAL or bronchial biopsy, but recent studies proposed induced sputum as another reliable and non-invasive tool to investigate airway inflammation in asthmatic patients. Thus, the relationship between airway inflammation assessed by induced sputum and airway hyperresponsiveness was investigated in asthmatic patient. Method : Airway responsiveness was determined by the concentration that caused a 20% decrease in $FEV_1$($PC_{20}$) after inhaling incremental concentrations of methacholine. The numbers of inflammatory cells and the concentration of eosinophilic cationic protein(ECP) were assessed in induced sputum obtained by inhalation of hypertonic saline(3%). Result: We analyzed sputum induced in 15 stable asthmatic patients. The differential cell count(%) of macrophages, neutrophils, eosinophils and lymphocytes in induced sputum were $39.1{\pm}27.0%$, $29.6{\pm}21.0%$, $28.8{\pm}18.8%$, $1.3{\pm}3.1%$ respectively. The mean value of baseline FEV1(predicted) and ECP were $76.3{\pm}30.3%$ and $1,101{\pm}833{\mu}g/L$ respectively. The geometric mean value of $PC_{20}$ was 0.56 mg/mL. The relationships between the sputum eosinophil and ECP in induced sputum, and between sputum eosinophil and degree of airway responsiveness($PC_{20}$) were found to be significantly correlated (r=0.81, p<0.05 and r=-0.78, p<0.05, respectively). Sputum neutrophils and $PC_{20}$ were not correlated to each other (r=0.11, p=0.69) and a significant negative correlation was found between ECP and baseline $FEV_1$(predicted)(r=-0.62, p<0.05). Conclusion : The results of this study suggest that an induced sputum via a inhalation of hypertonic saline is useful to determine a patient's status of airway inflammation, and airway inflammation is one of the major causal factors in the development of bronchial hyperresponsiveness in asthmatic patients.

  • PDF

2-D/3-D Seismic Data Acquisition and Quality Control for Gas Hydrate Exploration in the Ulleung Basin (울릉분지 가스하이드레이트 2/3차원 탄성파 탐사자료 취득 및 품질관리)

  • Koo, Nam-Hyung;Kim, Won-Sik;Kim, Byoung-Yeop;Cheong, Snons;Kim, Young-Jun;Yoo, Dong-Geun;Lee, Ho-Young;Park, Keun-Pil
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.127-136
    • /
    • 2008
  • To identify the potential area of gas hydrate in the Ulleung Basin, 2-D and 3-D seismic surveys using R/V Tamhae II were conducted in 2005 and 2006. Seismic survey equipment consisted of navigation system, recording system, streamer cable and air-gun source. For reliable velocity analysis in a deep sea area where water depths are mostly greater than 1,000 m and the target depth is up to about 500 msec interval below the seafloor, 3-km-long streamer and 1,035 $in^3$ tuned air-gun array were used. During the survey, a suite of quality control operations including source signature analysis, 2-D brute stack, RMS noise analysis and FK analysis were performed. The source signature was calculated to verify its conformity to quality specification and the gun dropout test was carried out to examine signature changes due to a single air gun's failure. From the online quality analysis, we could conclude that the overall data quality was very good even though some seismic data were affected by swell noise, parity error, spike noise and current rip noise. Especially, by checking the result of data quality enhancement using FK filtering and missing trace restoration technique for the 3-D seismic data inevitably contaminated with current rip noises, the acquired data were accepted and the field survey could be conducted continuously. Even in survey areas where the acquired data would be unsuitable for quality specification, the marine seismic survey efficiency could be improved by showing the possibility of noise suppression through onboard data processing.

A Study on the Factors affecting the Utilization of Waterscape Facilitiesin Apartment Complexes based upon Resident Perception - Focused on the Factors of Planning·Design, Maintenance and Usage - (주민인식에 기반한 아파트단지 내 수경시설 이용 영향 요인 분석 - 계획·설계, 유지·관리, 이용 행태를 중심으로 -)

  • Park, Do-Hwan;Cho, Se-Hwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.6
    • /
    • pp.62-75
    • /
    • 2017
  • This study analyzes the multiple effects of the following three aspects of waterscape facilities within apartment complexes: planning/designing, maintenance/management, and use of the facilities and suggests primary documents that will be fundamental for the methods to accelerate the implementation of waterscape facilities. A survey and analysis was conducted among a few of the most representative private apartment complexes in Seoul in accordance with the management and operation of waterscape facilities. The analysis used frequency analysis, descriptive statistics, reliability test, t-test, and PLS regression analysis. The research findings are as follows: first, the degree of use of waterscape facilities was found to be low regardless of the levels of operation, but residents' preference for the facilities was shown to be high, thus indicating there are still high expectations on the part of residents. Second, regardless of whether the facilities are being operated efficiently, the two items of location and display method under the section of planning and designing and the two items of aptitude and convenience under the section of use were found to positively affect the operation and use of waterscape facilities. Particularly, the item of freshness, cleanliness was shown to be directly and indirectly correlated with obsolescence, administration costs, and noise, which negatively affect the operation. Third, it was found that the administration costs itself that had been shown as the most negative factor of operating landscaping facilities in previous research did not cause problems in the residential area where the facilities are not operated efficiently. The finding suggests that the administration costs do not matter but that in the case of experience- and entertainment-typed facilities that residents want, they are linked to problems that do not introduce the desired facilities. Fourth, it was found that various aspects of planning, designing, maintaining, and using facilities interconnect and affect one another in the process of operating and using waterscape facilities resulting in the need to have a comprehensive approach to these three factors of planning, design, maintenance, management, and utilization. This study proposes that the needs and values of residents should be reflected to activate the introduction of landscaping facilities in the apartment complexes.

A Case Study on Forecasting Inbound Calls of Motor Insurance Company Using Interactive Data Mining Technique (대화식 데이터 마이닝 기법을 활용한 자동차 보험사의 인입 콜량 예측 사례)

  • Baek, Woong;Kim, Nam-Gyu
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.3
    • /
    • pp.99-120
    • /
    • 2010
  • Due to the wide spread of customers' frequent access of non face-to-face services, there have been many attempts to improve customer satisfaction using huge amounts of data accumulated throughnon face-to-face channels. Usually, a call center is regarded to be one of the most representative non-faced channels. Therefore, it is important that a call center has enough agents to offer high level customer satisfaction. However, managing too many agents would increase the operational costs of a call center by increasing labor costs. Therefore, predicting and calculating the appropriate size of human resources of a call center is one of the most critical success factors of call center management. For this reason, most call centers are currently establishing a department of WFM(Work Force Management) to estimate the appropriate number of agents and to direct much effort to predict the volume of inbound calls. In real world applications, inbound call prediction is usually performed based on the intuition and experience of a domain expert. In other words, a domain expert usually predicts the volume of calls by calculating the average call of some periods and adjusting the average according tohis/her subjective estimation. However, this kind of approach has radical limitations in that the result of prediction might be strongly affected by the expert's personal experience and competence. It is often the case that a domain expert may predict inbound calls quite differently from anotherif the two experts have mutually different opinions on selecting influential variables and priorities among the variables. Moreover, it is almost impossible to logically clarify the process of expert's subjective prediction. Currently, to overcome the limitations of subjective call prediction, most call centers are adopting a WFMS(Workforce Management System) package in which expert's best practices are systemized. With WFMS, a user can predict the volume of calls by calculating the average call of each day of the week, excluding some eventful days. However, WFMS costs too much capital during the early stage of system establishment. Moreover, it is hard to reflect new information ontothe system when some factors affecting the amount of calls have been changed. In this paper, we attempt to devise a new model for predicting inbound calls that is not only based on theoretical background but also easily applicable to real world applications. Our model was mainly developed by the interactive decision tree technique, one of the most popular techniques in data mining. Therefore, we expect that our model can predict inbound calls automatically based on historical data, and it can utilize expert's domain knowledge during the process of tree construction. To analyze the accuracy of our model, we performed intensive experiments on a real case of one of the largest car insurance companies in Korea. In the case study, the prediction accuracy of the devised two models and traditional WFMS are analyzed with respect to the various error rates allowable. The experiments reveal that our data mining-based two models outperform WFMS in terms of predicting the amount of accident calls and fault calls in most experimental situations examined.

Analyze for the Quality Control of General X-ray Systems in Capital region (수도권지역 일반촬영 장비의 정도관리 분석)

  • Kang, Byung-Sam;Lee, Kang-Min;Shim, Woo-Yong;Park, Soon-Chul;Choi, Hak-Dong;Cho, Yong-Kwon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.93-102
    • /
    • 2012
  • Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

Analysis of Building Characteristics and Temporal Changes of Fire Alarms (건물 특성과 시간적 변화가 소방시설관리시스템의 화재알람에 미치는 영향 분석 연구)

  • Lim, Gwanmuk;Ko, Seoltae;Kim, Yoosin;Park, Keon Chul
    • Journal of Internet Computing and Services
    • /
    • v.22 no.4
    • /
    • pp.83-98
    • /
    • 2021
  • The purpose of this study to find the factors influencing the fire alarms using IoT firefighting facility management system data of Seoul Fire & Disaster Headquarters, and to present academic implications for establishing an effective prevention system of fire situation. As the number of high and complex buildings increases and former bulidings are advanced, the fire detection facilities that can quickly respond to emergency situations are also increasing. However, if the accuracy of the fire situation is incorrectly detected and the accuracy is lowered, the inconvenience of the residents increases and the reliability decreases. Therefore, it is necessary to improve accuracy of the system through efficient inspection and the internal environment investigation of buildings. The purpose of this study is to find out that false detection may occur due to building characteristics such as usage or time, and to aim of emphasizing the need for efficient system inspection and controlling the internal environment. As a result, it is found that the size(total area) of the building had the greatest effect on the fire alarms, and the fire alarms increased as private buildings, R-type receivers, and a large number of failure or shutoff days. In addition, factors that influencing fire alarms were different depending on the main usage of the building. In terms of time, it was found to follow people's daily patterns during weekdays(9 am to 6 pm), and each peaked around 10 am and 2 pm. This study was claimed that it is necessary to investigate the building environment that caused the fire alarms, along with the system internal inspection. Also, it propose additional recording of building environment data in real-time for follow-up research and system enhancement.

Modeling and Implementation of Safety Test Device for Grounding System Based on IEC 60364 (IEC 60364의 접지방식에 기반한 안전성 평가 시험장치의 모델링 및 구현에 관한 연구)

  • Kim, Soon-Sik;Han, Byeong-Gill;Lee, Hu-Dong;Ferreira, Marito;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.599-609
    • /
    • 2021
  • A novel grounding system, which is presented in IEC 60364, has been adopted since 2021. A safety evaluation for the human body on the grounding system is required due to the various characteristics of the touch voltage and current passing when the human body experiences an electric shock. The Korea Electrical Safety Corporation (KESCO) and Korea Electric Association (KEA) have been conducting a safety technical education on the grounding system. On the other hand, it is difficult to instruct the electrical safety manager because of a lack of safety evaluations for the test equipment on the grounding system. Therefore, this paper modeled and implemented a test device for a safety evaluation depending on the grounding system of IEC 60364. Namely, this paper presents the modeling of the test device for a safety evaluation using PSCAD/EMTDC S/W, which is composed of an AC grid section, s test device section on the grounding system, and a sub-device section. This paper implemented a test device for safety evaluation, which consisted of an AC grid section, TT grounding system section, TN-S grounding system section, and monitoring section. From the simulation and test results with the safety characteristics of the human body in the TT and TN-S grounding system, when the fault impedances are 0[Ω], 10[Ω], and 100[Ω], the currents passing through the human body in the TT grounding system are 104[mA], 87.4[mA], and 35.5[mA], respectively. The corresponding currents in the TN-S grounding system are 54.9[mA], 4.1[mA], and 0.4[mA], respectively. Based on the results, the protection performance for an electric shock to the human body in the TN-S system is better than the TT system. This can be improved when the existing grounding system is changed from the TT system to the TN-S system.