• Title/Summary/Keyword: 고장용량

Search Result 196, Processing Time 0.032 seconds

Supercapacitive Properties of Carbon-Nano Fiber/MnO2 Composite Electrode (나노탄소섬유/MnO2 복합전극의 초고용량 캐폐시터 특성)

  • Lee, Byung Jun;Yoon, Yu Il;Ko, Jang Myoun
    • Korean Chemical Engineering Research
    • /
    • v.46 no.1
    • /
    • pp.94-98
    • /
    • 2008
  • In order to improve the specific capacitance of amorphous hydrous manganese oxide ($MnO_2$) for supercapacitors, it is made into composites with vapour-grown carbon nanofibers (VGCF) having the VGCF ratio as 40 wt% in the composites. The electrochemical properties of these composites are investigated in 1.0 M $Na_2SO_4$ by cyclic voltammetry (CV), impedance measurements and chronopotentiometric charger/discharger. The composite with 40 wt% VGCF shows the superior electrochemical performance, whose specific capacitance (based on the mass of $MnO_2$, $0.8mg/cm^2$) is 380 F/g at 20 mV/s and 230 F/g at 500 mV/s. Also, the cycle-life testing of this electrode carried out for 3,000 charge/discharge cycles at $2.0mA/cm^2$ shows 97% capacitance retention.

Queueing Network Model for Large-scale Multimedia -On-Demand Service Systems with Unreliable Components (결함 발생을 고려한 대규모 주문형 멀티미디어 서비스 시스템의 큐잉 네트워크 모델)

  • Park, Gi-Jin;Kim, Seong-Su
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.26 no.3
    • /
    • pp.291-300
    • /
    • 1999
  • 멀티미디어 서비스환경에서는 수백에서 수천의 클라이언트들이 하나의 서버에 접속되기 때문에 서버 결합이 미치는 영향이 상당히 크다. 이러한 결함은 단지 서버 자체의 장애로 끝나는 것이 아니라 그로 인해 서비스 제공자들에게 유형.무형의 막대한 재산상의 피해를 가져올수 있다. 본 논문에서는 멀티미디어 서버를 구성하고 있는 자원(프로세서, 디스크, 네트워크)의 결함 발생을 고려한 큐잉 네트워크 모델을 개발하였다. 복수개의 M/M/1 큐를 큐잉 네트워크로 연결하여, 각 자원에 대한 접근 및 서비스를 모델링하였으며, 각 자원에서의 서비스 시간 지연 비율(큐의 응답시간)의 조정을 통해서, 서버 자원의 결함 발생을 고려하였다. 고객 도착률과 자원 고장률 변동에 대한 서버 자원의 이용률과 큐의 길이를 구하여 효율적인 시스템 구성 자원의 부분별 용량을 산정하였으며 , 또한 데이터 패킷 응답 시간 분포 및 고장률 변화에 따른 시스템의 신뢰도 수준을 계산하였다. 이와 같은 서비스 시스템 성능에 관련된 파라미터 분석을 통하여 멀티미디어 데이터 서비스 수준 (Quality of Service)에 중요한 영향을 미치는 서버 설계 요소를 파악하였고, 시뮬레이터 패키지를 활용한 모의 실험을 통하여 개발된 큐잉 네트워크 모델의 정확성을 검증하였다.

The Research for a Structure of Current Limiter using a Phasic Similitude of Magnetic Circuit (자기회로의 위상학적 상사성을 이용한 전류제한기 구조에 관한 연구)

  • Ji, Geun-Yang;Jang, Bong-Hwan;Lee, Soo-Won;Min, Kyung-Il;Moon, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.344_346
    • /
    • 2009
  • 본 논문에서는 전력계통에서 고장발생시 자속의 변화를 통한 magnetic switching을 이용한 전류제한기를 제안하였다. 구조는 자속이 흐를 수 있는 철심과 회로에 연결되어 있는 1차권선, 철심과 1차권선 사이에 위차한 1차권선과 반대방향으로 감겨져 있는 2차권선 및 2차권선 하부에 이동이 가능한 동판의 2차권선 secondary로 구성되어 있다. 정상상태에서는 철심내에 1차권선과 2차권선에 의해 발생된 자속이 서로 상쇄되어 두 권선에 유기되는 전압은 0이지만 고장이 발생하여 2차 권선의 스위치를 open하고 2차권선 secondary를 철심밖으로 쳐 내면 그동안 상쇄되었던 자속이 철심을 통하여 흐르게 되고 이에 따라 1차권선에 유기된 전압은 회로의 전류를 제한하게 되므로 차단기를 용이하게 동작시킬 수 있는 구조이다. 실험을 통하여 전류제한기 동작 전 후의 전류제한 효과를 분석하였으며 이를 통해 본 논문에서 제안하는 시스템은 차단기에 가해지는 아크충격을 완화하여 설비의 수명을 연장하고 적은 용량의 차단기 사용이 가능하므로 설비투자예산 절감 및 모든 차단기 사용분야에 활용될 수 있는 장점을 가지고 있음을 확인하였다.

  • PDF

A Study of Insulation Breakdown Cause Analysis and Measure of 362kV 50kA Circuit Breaker for Shunt Reactor Switching (362kV 50kA 다빈도 차단기 고장원인 분석 및 대책에 관한 연구)

  • Choi, Young-Sung;Jeon, Sang-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.408-409
    • /
    • 2015
  • 한국전력공사에서는 2015년 4월말 기준 808개의 변전소를 운전 중에 있다. 변압기 용량으로 보면 299,734MVA에 달하고 있으며, 매년 증가하는 전력수요에 맞추어 신규 변전소 건설과 더불어 변전설비가 계속하여 확충되고 있다. 또한, 계절별 및 시간대별 부하변동에 따른 변전소 모선의 전압변동에 대응하기 위하여 Sh.C(Shunt Condenser), Sh.R(Shunt Reactor), SVC(Static Var Compensator) 등 다양한 무효전력보상 및 조절 설비들이 지속적으로 설치되고 있다. 이들 무효전력보상 설비들은 주로 변전소 모선에 전용 차단기를 통하여 연결되어 운전되고 있으며, 전용 차단기는 매일 시간대별 부하변동에 대응하여 개폐빈도가 많은 다빈도 차단기로서 잦은 개폐조작에 따른 내구성이 필요하며 변전소 모선전압을 기준전압 범위 이내로 안정적으로 유지하기 위한 신뢰성이 요구되고 있다. 본 논문에서는 345kV Sh.R 개폐용 동일유형의 345kV 50kA 1점절 다빈도 차단기에서 차단조작시 발생한 차단부 절연파괴 고장의 원인을 분석하고 재발방지를 위한 대책에 대하여 논하였다.

  • PDF

Reliability Analysis of MLCC Degradation Data based on Eyring Model (아이링 모델에 기초한 MLCC 열화데이터의 신뢰성 해석)

  • 김종철;김광섭;차종범
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2004.07a
    • /
    • pp.239-246
    • /
    • 2004
  • Accelerated degradation test (ADT) can be a useful tool for assessing the reliability when few or even no failure are expected in an accelerated life test. In this paper, MLCC (Multilayer Ceramic Capacitors), a sort of passive components which have large capacitance(X7R -55$^{\circ}C$~1$25^{\circ}C$) have been tested, and least-square analyses are used to illustrate our approach in which amount of degradation of a DUT following log-normal distribution. We assumed a simple and useful linear model to describe the amount of degradation over time subjected to different voltage levels applied. Tests for linearity of the performance-time relationship, and provide tests for how well the assumptions hold. Also, by using Eyring Model, MLCC's mean life time is assessed.

  • PDF

Schemes to Overcome ATM VC Switch Failures using Backup Virtual Paths (예비 가상 경로를 이용한 ATM VC 교환기 고장 우회 방법)

  • Yoo, Young-Hwan;Ahn, Sang-Hyun;Kim, Chong-Sang
    • Journal of KIISE:Information Networking
    • /
    • v.27 no.2
    • /
    • pp.187-196
    • /
    • 2000
  • Failures in ATM networks can occur at virtual path (VP) links, virtual path switches, and virtual channel (VC) switches. Restoration schemes have been proposed for VP link and VP switch failures, however, none for VC switch failures. In general, VC switches are used for edge nodes in protection domains. Since even only one VC switch failure can cause a critical problem, new restoration schemes for VC switch failures are highly required. Restoration schemes at the VP level proposed so far can be categorized into those using the flooding algorithm and those using the backup virtual path (BVP) concept. Even though the latter cannot handle unpredictable failures, it has some advantages such as fast restoration and low spare capacity requirement. In this paper, we propose new restoration schemes using a new type of BVPs to handle VC switch failures. The simulation results show that the proposed schemes can restore virtual connection failures due to VC switch failures without degrading restorability for VP failures.

  • PDF

A Study on the Evaluation of the Impact of Power System according to the Connection of Renewable Energy (신재생 전원 계통 접속에 따른 전력계통 영향 평가에 관한 연구)

  • Park, Seoung-Jun;Cho, Yun-Sung;Hur, Jin;Park, Sang Ho;Yoon, Gi Gab
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.733-737
    • /
    • 2018
  • In this paper, we describe the effects on the power system by adding renewable generator. In order to examine the stability of the system, the system analysis was performed using the PSS/E software. We confirmed whether occur the line overload of system through the load flow analysis and contingency analysis. and confirmed whether exceed of fault current using the fault current analysis. Dynamic stability of the system is analyzed through dynamic simulation. The analysis of the system according to the addition of the renewable generator was carried out according to the power system reliability and electricity quality maintenance standard.

Protection Coordination Analysis for Distribution Systems Integrated with Distributed Generation (분산전원이 도입된 배전계통의 보호협조 해석방법)

  • Kim, Jae-Eon;Kim, Eui-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2279-2284
    • /
    • 2011
  • In most of radial distribution systems, the overcurrent protection coordination is adopted for the protection of apparatus and the improvement of electrical power system reliability. The protection coordination structure in distribution substation is composed of several circuit breakers(CB) with distribution lines originating from one substation bus under one transformer, which trip for their fault current. But sufficient analysis is necessary for the capacity of CB's in distribution systems with several distribution generations(DG). In this paper, a protection coordination method not to exceed the traditional capacity of CB's was proposed and certified through simulation by the PSCAD-EMTDC S/W.

Supercapacitive Properties of a Hybrid Capacitor Consisting of Co-Mn Oxide Cathode and Activated Carbon Anode (코발트망간 산화물 양전극과 활성탄 음전극으로 구성된 초고용량 커패시터 특성)

  • Kim, Yong Il;Yoon, Je Kook;Kown, Je Sung;Ko, Jang Myoun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.440-443
    • /
    • 2010
  • A hybrid supercapacitor consisting of Co-Mn oxide as a cathode, activated carbon as an anode, and 6 M KOH as a electrolyte was fabricated and its supercapacitor performance was investigated by means of cyclic voltammetry. The prepared supercapacitor showed the specific capacitance of 67.3 F/g, energy density of 18.3 Wh/kg, and power density of 237.7 kW/kg, respectively. It means that the supercapacitor can be used for the practical applications.

A Study on Determination of Capacity for Pump and Detention Pond in Small Basins for Flood Control (소유역에서 홍수조절용 펌프 및 유수지 규모의 결정에 관한 연구)

  • Ahn, Tae-Jin;Park, Jong-Yoon;Lyu, Heui-Jeong;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.3 s.134
    • /
    • pp.385-398
    • /
    • 2003
  • The concept of the effective storage ratio has been suggested to determine the size of detention pond by the previous researchers. The 11 pump - pond facilities in Dongdu-chun city were selected to analyze the critical duration for design rainfall and the storage ratio for each rainfall duration in this study It has been then found that the criteria of the maximum storage ratio is not reasonable for determining the size of detention pond because the difference of storage ratio with respect to each rainfall duration is too small. Moreover, since the size of pond compared with the pump capacity is not always big enough, the pump should be frequently operated, which may result in pump failure. Thus, the pond should be sufficiently sized to prevent the possibility of the pump failure due to frequent operation. According to the analyses for changing pump capacity, it has been found that if the function of the pond compared with the pump is concentrated, determining the size of pond based on the storage ratio is operationally feasible for even small basin. Thus, an improved procedure based on the storage ratio for determining the size of detention pond in small basin has been suggested. The results by the proposed procedure considering pump switching frequency may lead to reasonable pump operation. A simple linear programming model has been also adopted to figure out the relationship between pump capacity and pond size. It has been shown that the determination lot the size of detention pond based on conventional hydrologic flood routing in pond is feasible for only urban districts not rural areas.