• Title/Summary/Keyword: 고장신호

Search Result 427, Processing Time 0.04 seconds

Implementation of a DCS Terminal Remote Monitoring System using Wire and Wireless Communication (유무선 통신을 이용한 DCS 터미널 원격 감시 시스템 구현)

  • Baek, Yeong-Tae;Lee, Se-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.3
    • /
    • pp.267-275
    • /
    • 2007
  • In this paper, we designed and implemented DCS terminal remote monitoring middleware for real-time auditor and management terminal status signal with relay and fuse status at power management room. The middleware consist of four component as event analyzer, event manager, service manager and user interface. We expected economic effects extend relay life-time that pre-detected errors and prevented relay fault.

  • PDF

A study on the Comparison of the International Standards for Railway Reliability (철도신뢰성관련 국제 규격비교 분석연구)

  • Han Seok-Youn;Ha Chen-Soo;Jun Bong-Roong;Lee Ho-Yong
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2005.05a
    • /
    • pp.267-271
    • /
    • 2005
  • 도시철도시스템은 차량, 전력, 신호, 선로구축물 등이 유기적으로 결합된 복합시스템으로 고장 또는 사고가 발생하면 원인규명이 어렵고 사고에 따른 영향이 매우 크기 때문에 시스템의 신뢰성과 안전성은 매우 중요하다. 본 논문에서는 철도에서 적용되고 있는 신뢰성관련 국제 규격을 분석하여 국내에서 개발하고 있는 무인운전 도시철도시스템에 이러한 규격들의 내용들을 충족하는 관리체계를 제시하고자 한다. 즉 기존에 적용하고 있는 신뢰성 관리체계인 IEC 60300, IEC 62278, MIL-STD-785B 등의 특성과 장점을 비교분석하여 도시철도시스템에 구체적으로 적용할 수 있는 신뢰성관리체계를 제시하고자 한다.

  • PDF

Design and Implementation of Embedded Based DCS Terminal Remote Monitoring System (임베디드 기반의 DCS 터미널 원격 감시 시스템 설계 및 구현)

  • Park, Hae-Dong;Ha, Jong-Hyun;Park, Hun-Chang;Lee, Se-Hoon
    • KSCI Review
    • /
    • v.15 no.1
    • /
    • pp.219-223
    • /
    • 2007
  • 이 논문에서는 기존 개발된 일체형의 통합 터미널 보드의 유선방식으로 자동제어시스템에서의 중요 신호에 대한 전체적 통합관리시스템 구축을 위한 DCS터미널 원격 감시 보드를 설계 제작하고 제작된 보드의 동작을 테스트하기 위해 원격감시 프로그램을 구현하여 기능을 평가한다. 구현된 원격감시보드는 전원관리실의 각 릴레이들의 동작상태 및 릴레이와 퓨즈의 이상 유무를 실시간으로 확인이 가능하며 릴레이의 수명을 고려하여 릴레이의 고장을 사전에 예방함으로써 산업분야의 경제적인 효과가 기대된다.

  • PDF

Fault Analysis of Electric Equipment Using Vehicle Signal (차량신호를 이용한 주요 전장품의 고장 분석)

  • Han, Young-Jae;Kim, Ki-Hwan;Kim, Sang-Soo;Lee, Byoung-Seog;Jung, Sang-Hun;Cho, Byoung-Chan
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1488-1494
    • /
    • 2006
  • The most important thing to secure safety and reliability of railway vehicles is to verify performance characteristics of equipments, and related companies or research institutes had many efforts to verify performances and functions of equipments synthetically and efficiently. KHST(Korean High Speed Train) has been developed by KRRI(Korea Railroad Research Institute). An electric railway system is composed of high-tech subsystems, among which main electric equipment such as transformers and converter are critical components determining the performance of rolling stock. We developed a measurement system for on-line test and evaluation of performances of KHST. The measurement system is composed of software part and hardware part. Perfect interface between multi-users is possible. A new method to measure temperature was applied to the measurement system. By using the system, fault diagnosis and performance evaluation of electric equipment in Korean High Speed Train was conducted during test running.

  • PDF

공동주택에 설치된 소화 및 제연시스템에 관한 화재연동 실태분석

  • Gang, Won-Seon;Son, Bong-Se;Jeong, Jong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.161-162
    • /
    • 2013
  • 최근에 신축되는 주상복합건축물이나 대단위 아파트단지는 지상층에서 보면 각각이 독립되어 있는 별도의 소방대상물로 보이지만, 실제로는 지하층을 통하여 연결된 하나의 소방대상물이다. 이러한 건물의 지하층에서 화재가 발생하면 열이나 연기가 다른 동으로 확산되어 피해가 커질 수 있으며, 특정동의 소방펌프에서 고장이 발생하거나 우발적인 선로합선 등으로 인하여 수신기에 이상이 발생하면 전체 동에 설치된 소방시설이 정상적으로 작동되지 않는 경우가 발생하게 된다. 화재감지기의 신호에 따라 작동되는 제연댐퍼, 준비작동식 스프링 클러설비 등이 수신기에서 연동되는 과정을 인천송도에 위치한 글로벌주상복합 단지를 토대로 하여 소화 및 제연설비의 연동실태를 분석하였다.

  • PDF

Fault determination of power transformer by using analysis of vibration signal (진동신호 분석을 이용한 변압기 고장판별법 연구)

  • Park, Su-Mun;Chung, Chan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1152-1154
    • /
    • 1996
  • In power transformers, vibration occurs at winding, core and case due to current, voltage, temperature changing and winding reformation. Winding deformation and change of vibration signals are occurred due to electromagnetic force induced by fault current. In this paper, in normal and fault states, the trends of fundamental waves and higher harmonics are considered. To inspect the factors that affect the fundamental waves and higher harmonics, the trends are considered with varying voltage and load. Determination functions are generated and applied to signals so that normal and fault state are determined by determination functions.

  • PDF

An Advanced Instrumentation Signal Analyzing Technique for Automated Power Plant Monitoring and Fault Diagnosis (발전소 운전감시 및 고장진단을 위한 계측기기 신호의 전처리 기법에 관한 연구)

  • Chang, Tae-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.450-453
    • /
    • 1996
  • This research presents a new method of detecting and diagnosing faults of a power plant. Detection of characteristic wave patterns from multichannel instrumentation signals forms the basis of the proposed approach. The dynamics of 500MW drum-type boiler (Boryung coal-fired plant unit #1 and #2) and its control systems are modeled and simulated to generate diverse operation patterns and fault situations and to utilize them for the development of the fault detection algorithms. The results of the boiler system modeling and simulations show a fairly high agreement when compared with some of the actual plant performance test data.

  • PDF

A Study on Performance Characteristics of Electric Equipments using Control Signal of High speed Train (고속열차의 제어신호를 이용한 전기장치의 성능 특성 연구)

  • Han, Young-Jae;Mok, Jing-Yong;Lee, Tae-Hyoung;Park, Chang-Su;Lee, Jun-Seok;Jo, Hyun-Uk
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1159-1160
    • /
    • 2007
  • 고속열차에서 주요 전장품들은 차량의 전체 성능을 좌우하는 매우 중요한 요소이다. 따라서 장치에 대한 성능 특성을 파악하고 진단하기 위해 상시계측시스템을 구축하였다. 또한 제작된 상시계측시스템을 통해 전장품에 대한 계측 및 분석을 통한 시험평가와 동시에 완성차 시험이나 본선시운전 시험시에 발생할 수 있는 고장원인을 찾아내었다.

  • PDF

Analysis of Series Arc-Fault Signals Using Wavelet Transform From Non-linear Loads (웨이블렛 변환을 이용한 비선형 부하 전원선에서의 직렬 아크고장 신호 분석)

  • Bang, Sun-Bae;Park, Chong-Yeun;Jang, Mog-Soon;Choi, Won-HO
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1470-1477
    • /
    • 2008
  • In this paper, a new detection method of series arc-fault signals occurring at the wiring of home appliances is proposed. The discrete wavelet transform was used for the numerical analysis of the variation rate in peak, RMS, noise energy, shoulder of the arc-fault current wave. As a results, the arc distinction threshold value of these variation rates was about 0.1 in most cases. The arc-fault current of the loads with the active PFC circuit showed a high rate of variation in noise energy and shoulder, but arc-fault current of the loads without the active PFC circuit showed a high rate of variation in peak and RMS. The arc fault current in resistive loads showed a high rate of variation in shoulder.

Study on Faults Diagnosis of Induction Motor Using KPCA Feature Extraction Technique (KPCA 특징추출기법을 이용한 유도전동기 결함 진단 연구)

  • Han, Sang-Bo;Hwang, Don-Ha;Kang, Dong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1063-1064
    • /
    • 2007
  • 본 연구는 유도전동기 진단시스템을 개발하기 위하여 테스트 전동기 내부에 취부된 자속센서 신호를 사용한 알고리즘 적용 결과를 논한 것으로서 분류기별 고장 판별 정확도에 대하여 서술하였다. 특징추출은 Kernel Principal Component Analysis (KPCA) 방법을 이용 하였으며, 테스트 샘플들에 대해서는 LDA(Linear Discriminant Analysis)와 k-NN(k-Nearest neighbors) 분류기법을 이용하여 판별하였다. 회전자 바 손상이나 편심(동적/정적)인 경우는 두 가지 분류기 모두 95[%]이상의 높은 분류 정확도를 보였지만, LDA인 경우 정상상태를 비롯한 베이링 불량이나, 샤프트 변형인 경우는 낮은 분류율을 보였다.

  • PDF