• Title/Summary/Keyword: 고장보호시스템

Search Result 120, Processing Time 0.045 seconds

Estimating the Failure Rate of Protection System Using a Discrete Markov Model (이산 마코프 모델을 이용한 보호 시스템의 고장 비율 추정)

  • Shin, Jung-Jin;Lee, Hee-Tae;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.385-387
    • /
    • 2008
  • When a fault occurs in the distribution system, it is detected by protection system, then protection system is opened and de-energises the feeder where the fault exists. in this paper, the failure rate of protection system will estimate that using a discrete markov approach with failure data of protection system in order to improve the reliability of protection system.

  • PDF

An Application of DFT for Accurate Frequency Measurement (정확한 주파수 계측을 위한 DFT 필터의 적용)

  • Park, Chul-Won;Lee, Ha-Na
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2249_2250
    • /
    • 2009
  • 전력계통이 대규모, 다양화됨에 따라 계통의 안정화를 위한 광역보호계전 지능화 기술 개발이 요구되고 있다. 이를 위해서 네트워크 기반 주파수 모니터링 및 고장예측 시스템 개발 분야에 관심이 증대되고 있다. 본 논문은 정확한 주파수 계측을 위해서 요소기술로 필수적으로 사용해야하는 DFT 필터의 크기 응답, 위상 응답 등에 대해 연구하였다.

  • PDF

A Study on the Protection Method with Interconnection of Wind-Power Generation System (풍력발전시스템의 계통연계 보호방식에 관한 연구)

  • 김응상;김일동
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.216-223
    • /
    • 2002
  • Generation facilities of the power system are mainly classified into large-scale concentrated generation and small-scale dispersed generation, but generation planning of the Korea power system has been focusing on the large-scale generation so far. Recently, however, applications of dispersed generation sources including solar cell, fuel cell, wind power, etc. have been rapidly increasing and being strongly promoted, and such generation sources should be comprehensively considered in both planning and operating. Since it is not always possible that the dispersed generation alone meets all the load interconnected to it is especially when a fault occurs, interconnection into the existing utility is desirable and recommended. In relation to wind power generation systems interconnected at the low and extra high voltage levels, this paper performs the simulation and analysis of the system protection and suggests protection coordination plans on various faults which possibly occur.

Analysis for digital excitation system with IGBT devices (IGBT소자로 구성된 디지털 여자시스템에 관한 분석)

  • Lee, Jae-Do;Lim, Ick-Hun;Lee, Ju-Hyun;Ryu, Ho-Sun;Shin, Man-Su
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1105-1107
    • /
    • 2003
  • 일반적으로 정지형 석자시스템은 싸이리스터 제어 정류기를 사용하고 있으나 제주화력에는 IGBT 소자로 구성된 강압형 쵸퍼방식으로 하드웨어 연구가 필요한 실정이다. 발전기 제어시스템이 후비보호가 없는 경우 사소한 고장으로 인한 코아 발전소의 정지로 계통 파급효과가 크게 발생되므로, 이런 현상을 방지위해 디지털 다중화 방식의 설비를 개발하여 신뢰도의 증강 및 안정적인 전력공급이 필요하다. 이를 위해 우선적용 IGBT 소자로 구성된 디지털 여자시스템의 분석을 통해 현장적용에 알맞은 디지털 여자시스템의 신뢰성, 안정성, 기능성을 갖춘 발전기 여자시스템를 개발하고자 한다.

  • PDF

Effect of Internal Circuit Faults of Non-reference Type APS Malfunction on Commercial and Tactical Vehicles (참조센서가 없는 상용/전술차량용 APS내부 회로 불량이 오작동에 미치는 영향)

  • Jo, Yong Jin;Cho, Haeng Muk
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.163-170
    • /
    • 2016
  • In the condition of electronic controlled acceleration system, APS Sensor is the only and the most important parts to reflect the will of driver. Especially, the non-reference type APS is the critical part of this system. It can't provide the cross-reference values and it will make the vehicle goes into the 'NMC(Non-moveable condition)' or 'Limp-home mode' on the malfunction situation easier. If the situation is happened, it's very dangerous condition for the drivers, soldiers and war material systems of battlefield. The electronic control is not a necessary system for the tactical vehicles. The tactical vehicles must be prepared the manual control system independently from the electronic control system to escape, save and rescue the soldier's life and war materials. Therefore it was studied the water-penetrated broken APS output. If the output value was changed without driver's will, even the cross-reference type APS, it will effect the uncontrollable engine RPM changing or the performance down on limp-home mode. It means the manual control system of tactical vehicle is needed for any kinds of APS.

Lightning Protection System of Solar Power Generation Device (태양광발전장치의 낙뢰보호 시스템)

  • Yongho Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.157-162
    • /
    • 2023
  • Among the failures of photovoltaic power generation facilities, failures caused by surges account for 20% of the total failure rate, and energy emissions of tens to hundreds [A] during power generation and electrical damage to inverters and connection boards lead to electrical safety accidents. In particular, in the case of lightning, an abnormal voltage is induced in an electric circuit to destroy insulation, and the current flowing at this time causes a fire and acts as a factor that accelerates the deterioration of parts. Due to this action, the problem of electrical safety of solar power generation devices spreading from outside the city center to the inside of the city center such as houses, apartments, and government offices is emerging. Since lightning strikes cause both field-based and conducted electrical interference, this effect increases with increasing cable length or conductor loops. In addition, surge damages not only solar modules, inverters and monitoring devices, but also building facilities, which can eventually cause operational shutdown due to fire of the photovoltaic power generation system and consequent financial loss. Therefore, in this paper, a lightning protection system for solar power generation devices is studied for the purpose of reducing property damage and human casualties due to the increase in fire and electrical safety accidents caused by lightning strikes in photovoltaic power generation systems.

ATM Network Survivability Enhancement Scheme using Disjoint VP Groups (분리 VP 그룹을 이용한 ATM 망 생존도 향상 방안)

  • Lee, Gil-Heung;Choe, Yong-Hun;Park, Won-Seo;Lee, Jae-Yong;Lee, Sang-Bae
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.26 no.8
    • /
    • pp.949-956
    • /
    • 1999
  • 이 논문에서는 ATM (Asynchronous Transfer Mode) 방식의 초고속망의 장애 발생 시 이용자 연결의 QoS (Quality of Service)를 고려하여 복구할 수 있게 하는 보호 망 설계 방안을 제시한다. 제시한 설계 방안에 기초한 비용과 복구 특성을 분석과 모의 실험을 통해 알아본다. 제안하는 망에서의 복구는 분리 VP 그룹 (Disjoint Virtual Path Group, DVPG) 을 사용하는 상태 독립적 (State- independent) 방식으로 복구된다. ATM 망의 운용 및 보호 VP 할당과 용량 배정 문제를 정의하고 이를 바탕으로 최소의 비용을 갖는 VP 망을 설계한다. 망의 고장 시 기존 노드간의 VP 연결은 미리 할당된 링크 또는 노드 분리 보호 VP 경로를 따라 간단한 복구 알고리즘에 의해 빠르게 복구된다. QoS의 고려는 추가 비용을 필요로 하지만 정확한 이용자 연결의 복구를 실현하며, 분리 VP 그룹의 적용은 비용을 상승시키지만, 빠른 복구와 복수의 고장에 대처할 수 있는 방안이 된다.Abstract A cost evaluation of protection scheme for VP-based ATM network is presented here and its related characteristics are evaluated. The proposed and evaluated scheme is a state-independent restoration scheme using a disjoint path group. For fast and simple restoration of failed connections, link disjoint or node disjoint VP groups (DVPG) were utilized in this paper. A VP assignment and capacity planning problem is formulated. When failure occurs, the failed working VPs are switched to the protection VPs of disjoint path groups with a simple restoration scheme. And, cost evaluation and restoration characteristics are presented. The consideration of multiple QoS (Quality of Service) levels and disjoint path group protection scheme require additional network cost but acquire fit and fast restoration.

A Study on the Calibration of Measuring Instruments for the Short Circuit Test System (단락시험설비의 측정시스템 교정에 관한 연구)

  • Kim, Dong-Su;Kim, Bong-Sung;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.955-956
    • /
    • 2007
  • 차단기는 전력계통에서 사고시 고장점을 분리 차단하여 계통을 보호하고, 복구 완료시 전원을 투입하는 장치로 전력기기 중 가장 중요한 제품이며, 특히 저압 차단기는 실제 가정 및 소규모 공장에서 많이 사용되고 있어 안전성과 성능의 신뢰성이 가장 중요한 제품이므로 단락성능에 대한 성능평가가 이루어져야 한다. 이와 같은 단락성능평가를 위한 단락시험설비의 측정시스템은 시험 신뢰도의 확보를 위해 주기적으로 교정하여 사용하여야 한다. 본 논문에서는 측정시스템으로 구성된 각 계측기의 교정 결과를 이용하여 전체 측정시스템을 교정하고자 한다.

  • PDF

A Study on Frequency Measurement Technique for Wide Area Protection (광역보호를 위한 주파수 측정기법에 관한 연구)

  • Park, Chul-Won;Kim, Yoon-Sang;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2023-2024
    • /
    • 2008
  • 근래 초기고장(seed fault)에 대한 적절치 못한 대책들이 광역정전으로 파급되어 그 피해정도가 매우 심각하다. 전력의 안정적 공급에 대한 중요성이 새롭게 부각되고 그 예방책에 대한 다각적인 연구가 요구되고 있다. 이에 위성망을 이용한 위기 관리시스템에 대한 필요성이 제기되었다. 본 논문에서는 광역보호를 위해 sPMU(satellite Phasor Measurement Unit), 전력계통 상태감시장치(Power System Dynamic Monitor:PSDM)에 중요한 요소로서 전력계통에서 가장 중요한 지표중의 하나인 주파수에 대한 여러 가지 측정방법을 다룬다. 향후 정상상태와 과도상태에서도 측정시간 단축과 측정오차를 줄일 수 있는 최적의 주파수 계측기법을 개발하기 위함이다.

  • PDF

The Application of Variable Frequency Drive for Forced Draft Fan (보일러 압입통풍기용 인버터 적용기술)

  • Lim, Ick-Hun;Kim, Bong-Suck;Ryu, Ho-Seon;Lee, Joo-Hyun;Whang, Young-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.185-187
    • /
    • 2006
  • 본 논문에서는 평택화력 제2호기 FDF(Forced Draft Fan : 압입송풍기, 이하 FDF) 출구의 공기량제어를 Vane Control 시스템으로 구성되어 있는 것을 구동 유도전동기에 가변속 제어시스템(이하 VFD: Variable Frequency Drive)으로 교체하여 발생한 실험결과를 보여준다. VFD는 Vane을 전개(全開)하고 전동기 속도를 변경시켜 연소에 필요한 노내 공기량을 제어하는 방식이다. VFD 운전은 정속도 Vane 개도 운전에 비해 Throttle Loss를 최소화해서 에너지 절감효과는 크지만 간단한 Vane 제어기에 비해 복잡한 전력전자제어시스템이 어우러진 기기로 신뢰도는 떨어지는 것이 사실이다. 따라서 고도의 신뢰성이 요구되는 전력생산 보일러에서 후비보호책으로 VFD 고장 시에 Vane제어 모드로 절환은 필연적으로 필요한 설비이다. VFD에서 Vane으로 절환 시에 일어나는 과도상태를 최소화하기 위해서는 보일러 연소제어 알고리즘의 최적화가 필요하다. 본 논문에서는 구현된 제어알고리즘을 정리한 것이다.

  • PDF