• Title/Summary/Keyword: 고인성 섬유보강 콘크리트

Search Result 50, Processing Time 0.021 seconds

W/C Ratio Effects on Mechanical Properties of High Performance hybrid SC and PE Fibers Reinforced Cement Composites (물-시멘트비에 따른 하이브리드 섬유보강 고인성 시멘트 복합체의 역학적 특성)

  • Yun, Hyun-Do;Kim, Sun-Woo;Cheon, Esther;Lee, Sang-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.118-121
    • /
    • 2006
  • The research reported here is concerned with the effects of the fiber combination condition and water/cement ratio on the mechanical properties of high performance fiber-reinforced cementitious composites(HPFRCC). An experimental investigation of the behavior of steel cords(SC) and SC and Polyethylene(PE) hybrid fiber reinforced cementitious material under compressive and tensile loading is presented. In this experimental research, the tensile and compressive strength and strain capacity of HPFRCC were selected using the cylindrical specimens. The results show that W/C ratio is a significant effect factor on the compressive and tensile performance of HPFRCC. The envelope curve concept applies to hybrid fiber-reinforced cementitious composites in tension just as it does to compressive stress-strain curve of fiber-reinforced cement composites. For practical purposes, the tensile envelope curve may be taken to be the same as the monotonic tensile stress-strain curve.

  • PDF

Bending Property of Composited Ductile Fiber Reinforced Cementitious Composite, DFRCC (고인성 섬유보강 시멘트 복합재료의 복합구성에 의한 휨 특성)

  • 김규용;손유신;양일승;후쿠야마히로시;윤현도;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.367-372
    • /
    • 2003
  • Fiber Reinforced Cementitious Composite, DFRCC has strain hardening property with multiple crack in failed of compressive, tensile, bending force, concrete is not so that. But DFRCC could not use to the building element for which has not structural stiffness only has ductile property. DFRCC is used for repair only in recently. In that reason, we considered the concrete of light weight concrete, porous concrete, mortar complex with DFRCC. and DFRCC reinforced by fiber net, steel bar. In this study, results of experiment on complex method of concrete and DFRC were shown as follows; The complex methods of concrete lay on DFRCC, sandwich layer composition were effective for bending force depending on section size each layer, and reinforce DFRCC by fiber net, steel bar was effective method also.

  • PDF

An Behavior of RC Columns Using High Performance Fiber Reinforced Cement Composites under Axial Loads (일정축력을 받는 고인성 섬유보강 시멘트 복합체 기둥의 거동)

  • Hwang Sun-Kyoung;Yun Hyun-Do;Han Byung-Chan;Park Wan-Shin;Yang Il-Seung;Cheon Esther
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.87-90
    • /
    • 2005
  • An experimental investigation on the strength and behaviour of reinforced concrete columns using high performance fiber reinforced cement composites has been carried out. The columns were subjected to monotonic axial compression until failure. The variables in this study are the combination ratio of steel cord(SC) and Polyethylene (PE), and the volumetric ratio of transverse reinforcement Test results showed that the fibers, when used in a hybrid form, could result in superior composite performance compared to their individual fiber reinforced cement composites.

  • PDF

The Structural Behavior of Seismic Devices using High Performance Fiber Reinforced Cement Composites (고인성 섬유보강 시멘트 복합체를 사용한 내진요소의 구조성능)

  • Yang Il-Seung;Yun Hyun-Do;Han Byung-Chang;Park Wan-Shin;Kim Sun-Woo;Moon Yeon-Jun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.21-24
    • /
    • 2004
  • Structural performance of the seismic devices made by steel bar and high performance fiber reinforced cement composites(HPFRCCs) was experimentally observed. These dampers will be applied for reducing damage as well as seismic response. The advantages of the HPFRCCs damper is selective structural performance, strength, stiffness, and ductility by changing configuration, bar arrangements and type of materials used. The experimental results indicate that elemental ductility is much increased with decreasing damage when the HPFRCCs are applied to the damper. It means cementitious damper for structural control is available which has much merit in performance and cost.

  • PDF

Tension Stiffening of High Performance Fiber-Reinforced Cementitious Composites (고인성 섬유보강 시멘트 복합체의 인장강성)

  • Yun Hyun-Do;Yang Il-Seung;Han Byung-Chan;Hiroshi Fukuyama;Cheon Esther;Kim Sun-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.441-444
    • /
    • 2004
  • This paper presnets the tensile behavior of 8 high performance fiber-reinforced cementitious composites (HPFRCCs) members, each reinforced with one deformed bar 16mm in diameter. The variables included HPFRCC(Ductal, steel cord and polyethylene hybrid fiber, PE fiber) versus normal concrete. Fibers used in HPFRCC significantly increased tensile strength, ductility, and tension stiffening of cementitious materials. For HPFRCC, after first cracking, tensile load continue to rise without fracture localization. Sequentially developed parallel cracks contributed to the inelastic strain at increasing stress level. After yielding of the reinforcing bars, HPFRCC showed increases in loads with increasing strains.

  • PDF

Performance and Evaluation of Flexural Toughness Indices for HPFRCCs (고인성 섬유보강 시멘트 복합체의 휨인성 성능 및 평가)

  • Han Byung Chan;Yang Il-Seung;Park Wan Shin;Jeon Esther;Kim Sun Woo;Yun Hyun Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.615-618
    • /
    • 2004
  • The primary role of fibers in High performance fiber reinforced cement composites(HPFRCCs) is to improve the toughness, or energy absorption capacity, of the composite material, However, there is still no general agreement as to how this toughness should be characterized, or how it might be used in the design of structures containing HPFRCCs. In this paper, therefore, we focus on test techniques for measuring flexural toughness. For mechanical properties, HPFRCCs can be tested in the same way as fiber reinforced concrete(FRC). Both the significance and the limitations of somewhat different national and industrial standards of FRC are discussed. For flexural toughness, with depend on the presence of fibers, new test methods was developed and verified. We also suggest evaluation method of tensile toughness indices using the moment curvature relationship in flexural tests.

  • PDF

Flexural Behavior of Dual Concrete Beams Using Fiber Reinforced Concrete at Tensile Parts (섬유보강 고인장강도 콘크리트를 이용한 이중 콘크리트 보의 휨 거동 해석)

  • 박대효;부준성;조백순
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.584-592
    • /
    • 2001
  • The cracks are developed in reinforced concrete(RC) beams at the early stage of service load because of the relatively small tensile strength of concrete. The structural strength and stiffness are decreased by reduction of tensile resistance capacity of concrete due to the developed cracks. Using the fiber reinforced concrete that is increased the flexural strength and tensile strength at tensile part can enhance the strength and stiffness of concrete structures and decrease the tensile flexural cracks and deflections. Therefore, the RC beams used of the fiber reinforced concrete at. tensile part ensure the safety and serviceability of the concrete structures. In this work, analytical model of a dual concrete beams composed of the normal strength concrete at compression part and the high tension strength concrete at tensile part is developed by using the equilibrium conditions of forces and compatibility conditions of strains. Three groups of test beams that are formed of one reinforced concrete beam and two dual concrete beams for each steel reinforcement ratio are tested to examine the flexural behavior of dual concrete beams. The comparative study of total nine test beams is shown that the ultimate load of a dual concrete beams relative to the RC beams is increased in approximately 30%. In addition, the flexural rigidity, as used here, referred to the slope of load-deflection curves is increased and the deflection is decreased.

Shotcrete-Retrofit of Shear Walls with an Opening (개구부를 가지는 전단벽의 숏크리트 보강)

  • Choi, Youn-Cheul;Choi, Chang-Sik;Kim, Hyun-Min;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.71-80
    • /
    • 2007
  • Because of the characteristics relating to high tensile ductility, High Performance Fiber Reinforced Cementitious Composites (HPFRCC) are studied to be adopted in repair and retrofit of buildings. A series of three shear wall specimens was tested under constant axial stress and reversed cyclic lateral loading in order to evaluate the seismic retrofit that had been proposed for the shear wall with the opening. The retrofit involved the use of newly developed ECC and MDF(Macro Defect Free), both of which are sprayed through the high pressure pump, over the entire face of the wall. The results indicate that two difference types of retrofitting strategy make the different effects of a rise in the strength and ductility of each specimen.

The Prediction of Debonding Strength on the Reinforced Concrete Beams Strengthened with fiber Reinforced Polymer (섬유복합체로 휨보강된 RC보의 박리하중 예측에 관한 연구)

  • Hong Geon-Ho;Shin Yeong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.903-910
    • /
    • 2005
  • In recent years, fiber reinforced polymer(FRP) plates have shown a great promise as an alternative to steel plates for reinforced concrete beam rehabilitation. Reinforced concrete beams strengthened with externally bonded FRP sheets to the tension face can exhibit ultimate flexural strengths several times greater than their original strength if their bond strength is enough. Debonding failure, however, may occur before the strengthened beam can achieve its enhanced flexural strength. The purpose of this paper is to investigate the debonding failure strength of FRP-strengthened reinforced concrete beams. An analytical procedure for calculating debonding load between concrete and strengthening FRP is presented. Based on the local bond stress-slip relationship in the previous studies, uniform bond stress is assumed on the effective bond length. The analytical expressions are developed from linear elastic theory and statistical analyses of experimantal results reported in the literature. The proposed method is verified by comparisons with experimental results reported in the previous researches.

Enhancements in Performance and Manufacturing Efficiencies of GFRP Rebar (GFRP 보강근의 성능 및 제작 효율화 방안)

  • You, Young Jun;Kim, Jang Ho;Park, Young Hwan;Park, Ji Sun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.110-119
    • /
    • 2012
  • Fiber reinforced polymer (FRP) reinforcing rebar with non-corrosive property is suggested as an alternative replacement to steel reinforcing rebar due to its enhanced durability and non-corrosive characteristics. Currently, a limited number of glass fiber reinforced polymer rebar (GFRP) are sold commercially due to their high cost, relatively low performances, and brittle failure characteristics. Therefore, the performance enhancements and cost reduction of GFRP rebar are needed to increase its applications in construction fields. The intent of this study is to develop high performance GFRP rebar by improving its tensile and shear properties. Also, in order to reduce manufacturing costs, factors such as material composition and manufacturing process were evaluated to improve manufacturing efficiency. Finally a GFRP rebar with enhanced material properties and less expensive than the GFRP rebar currently sold in the market was manufactured and evaluated for its application possibility in construction fields.