• Title/Summary/Keyword: 고유임상

Search Result 166, Processing Time 0.025 seconds

Prior Eco-preserve Zoning through Stream Ecosystem Evaluation on Dam Basin -A Case of Yongdam-dam Watershed, Jeollabukdo Province- (댐유역 하천생태계평가를 통한 생태보전우선지역설정 -용담다목적댐 유역을 사례로-)

  • Lim, Hyun-Jeong;Lee, Myung-Woo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.2
    • /
    • pp.103-112
    • /
    • 2011
  • The purpose of this study is to specify the prior eco-preserve zone by establishing the eco-landscape unit on the stream corridor and evaluating the stream ecosystem in the dam basin. The fundamental ecological data was surveyed and collected through "the ecosystem project on Yongdam multipurpose dam watershed" from 2008 to 2009. The Yongdam Dam Watershed has several streams, Jujacheon, Jeongjacheon and Guryangcheon, of which the area is $930km^2$, stretching to Jinangun, Jangsugun and Mujugun Jellabukdo. In spite of being used for drinking purpose, the dam water quality and ecosystem is threatened by in-watershed pollution produced by development, golf course grounds and sports complex, etc. The landscape unit of stream corridor was zoned across by 250m, 500m, and 750m from the vicinity line of stream, which was decided to the accuracy of mapping and surveying. Types of evaluation are the Stream Corridor Evaluation(SCE) and the Vegetated Area Evaluation(VAE). In the process of SCE, several indices were analysed, fish species diversity, species peculiarity, and stream naturality. Indices for VAE were forest stand map, vegetation protection grade, species diversity and peculiarity for wild bird and mammal life. The importance of the ecological items is categorized into three levels and overlapped for specifying the prior preserve zone. The area at which legally protecting species appeared is categorized as absolute preserve area. This study might be meaningful for proposing the evaluation process of a stream corridor ecosystem, which can synthesize a lot of individual ecological surveys. We hope further research will be actively performed about the ecotope mapping which is based on a individual wildlife territory and habitats and also their relationships.

A Study of Test-Retest Reliability and Interrater Reliability of the Sensory Processing Scale for Children (SPS-C) (아동감각처리척도(Sensory Processing Scale for Children; SPS-C)의 검사-재검사 신뢰도와 검사자간 신뢰도 연구)

  • Kim, Kyeong-Mi;Kim, Ga-Yeon;Lee, Seung-Jin
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.20 no.2
    • /
    • pp.11-21
    • /
    • 2022
  • Objective : This study examined the test-retest reliability and interrater reliability of the Sensory Processing Scale for Children (SPS-C). Method : Senventy primary caregivers of children with sensory processing difficulties and 3 years old participated in the study. The subjects were recruited through child development centers, welfare centers, and acquaintances located in Seoul, Gyeonggi-do, Busan, and Gyeongsang-do. The test-retest reliability verification targeted 20 main caregivers of children with difficulty in sensory processing. Re-evaluation was performed within 7 to 14 days after the initial evaluation, and Pearson's correlation coefficient was used to confirm the relevance between the two time points, and the Intraclass correlation coefficient was used to confirm the degree of agreement. The interrater reliability verification was conducted with 18 primary caregivers and 18 subsidiary caregivers of children with sensory processing difficulties. Each caregiver evaluated the same child, and the Intraclass correlation coefficient was used to confirm the agreement between the two sets of caregivers. Results : The test-retest reliability was Pearson's correlation coefficient r=.914 and intraclass correlation coefficient ICC=.939, indicating a high level of relevance and agreement. The interrater reliability was an Intraclass correlation coefficient ICC=.727, which showed a moderate level of agreement, but the tactile area (ICC=.455) and proprioceptive area (ICC=.439) were not statistically significant and showed a low degree of agreement. Conclusion : Through this study, it was confirmed that the children's Sensory Processing Scale for Children (SPS-C) is a stable evaluation tool with test-retest reliability and interrater reliability verified, and it will be able to provide help in standardization studies for future clinical use.

Dental Assistant and Dental Hygienist-comparison with U.S. (치과 보조 인력과 치과위생사-미국의 제도 비교)

  • Youngyuhn Choi
    • Journal of Korean Dental Hygiene Science
    • /
    • v.6 no.2
    • /
    • pp.65-77
    • /
    • 2023
  • Background: The shortage of dental hygienists as assistant is a great concern to dental clinics, while dental hygienists are rather pursuing the role of oral hygiene control and preventive treatments which is the main role for dental hygienists in the United States. The dental hygienist and dental assistant system in the United States can be a reference in these discussions. Methods: Educational requirements for licensure and work areas for dental hygienists and dental assistants were investigated through the information provided by the American Dental Association (ADA), American Dental Hygienists Association, National Board Dental Hygiene Examination (NBDHE), Dental Assistants Association of America (ADAA), and Dental Assistants National Board (DANB). Results: In the United States, each state has different systems, but in general, dental hygienists obtain licenses after completing 2~3 years of associate degree programs in dental hygiene after obtaining basic learning skills, and mainly perform tasks related to patient screening procedures, oral hygiene management and preventive care. Dental assistants can take the license test after completing a training course of 9~11 months to obtain a dental assistant certification. Additional expanded work typically requires passing state qualification tests, completing a training program, obtaining a degree, or gaining clinical experience for a certain period of time, depending on the state Conclusion: The scope of work of dental hygienists designated by the Medical Engineer Act and the Enforcement Decree in Korea includes both the work of dental hygienists and dental assistants in the United States, and if a dental assistant system like the United States is introduced to address the current shortage of dental assistants, institutional supplementation such as adjustment of the scope of work and expansion of the role of dental hygienists in oral hygiene management and prevention work is needed and in-depth discussion is necessary.

Changes in Serum IGF-I and Spermatogenesis Analysed by Flow Cytometry in Growing Male Rabbit (성장 중인 수토끼에서 혈청 IGF-I 수준과 Flow Cytometry 측정에 의한 정자 형성의 변화)

  • Lee J. H.;Kim C. K.;Chang Y. M.;Ryu J. W.;Park M. Y.;Chung Y. C.;Pang M. G.
    • Reproductive and Developmental Biology
    • /
    • v.29 no.3
    • /
    • pp.163-168
    • /
    • 2005
  • The aim of this study was to investigate the changes in insulin-like growth factor-I (IGF-I) and growth hormone (GH) in serum, the quantitation of spermato-genesis and the comparable relationships among these measurements during pubertal period in New Zealand White male rabbits. To investigate the age-related testicular changes in DNA contents of spermatogenic cells, the fine-needle testicular biopsies from males aged 10 to 28 wks were evaluated by flow cytometry(FCM). Body weight increased significantly between the ages of 12 and 20 wks (P<0.05) and reached 3.4 kg at 28 wks of age. The highest serum IGF-I level (451.3ng/mL) was observed at 20wks of age (P<0.05) and thereafter remained stable at low levels. Serum GH level at 18 wks of age was 183.3 pg/mL which was significantly higher compared to the other ages (P<0.05), and the rising time in serum GH tend to be somewhat earlier than that of IGF-I. The relative percentage of It-cells in testicular cell compartments was $48.2\%$ at the age of 18 wks which significantly increased than those of 16-wk-old (P<0.05) and thereafter increased with the advance of age to $68\%$. The percentage of 2C-cells in testis was $26.8\%$ at 18 wks of age which was significantly lower than $54.3\%$ at 16 wks old (P<0.05). The percentage of 4C-cells was constantly maintained $2\~6\%$ except the $9.9\%$ at 18 wks of age. In conclusion, the results suggest that the puberty onset occurred at about the 18 wks of age and that the IGF-I and GH in serum during the pubertal period showed the age/growth-specific changes and these changes might be related to the spermatogenesis. The DNA FCM combined with fine-needle testicular biopsy could offer a very sensitive method to monitor the quantitative spermatogenic events related to the puberty onset.

Analysis of Bone Mineral Density and Related Factors after Pelvic Radiotherapy in Patients with Cervical Cancer (골반부 방사선 치료를 받은 자궁경부암 환자의 골밀도 변화와 관련 인자 분석)

  • Yi, Sun-Shin;Jeung, Tae-Sig
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.15-22
    • /
    • 2009
  • Purpose: This study was designed to evaluate the effects on bone mineral density (BMD) and related factors according to the distance from the radiation field at different sites. This study was conducted on patients with uterine cervical cancer who received pelvic radiotherapy. Materials and Methods: We selected 96 patients with cervical cancer who underwent determination of BMD from November 2002 to December 2006 after pelvic radiotherapy at Kosin University Gospel Hospital. The T-score and Z-score for the first lumbar spine (L1), fourth lumbar spine (L4) and femur neck (F) were analyzed to determine the difference in BMD among the sites by the use of ANOVA and the post-hoc test. The study subjects were evaluated for age, body weight, body mass index (BMI), post-radiotherapy follow-up duration, intracavitary radiotherapy (ICR) and hormonal replacement therapy (HRT). Association between the characteristics of the study subjects and T-score for each site was evaluated by the use of Pearson's correlation and multiple regression analysis. Results: The average T-score for all ages was -1.94 for the L1, -0.42 for the L4 and -0.53 for the F. The average Z-score for all ages was -1.11 for the L1, -0.40 for the L4 and -0.48 for the F. The T-score and Z-score for the L4 and F were significantly different from the scores for the L1 (p<0.05). There was no significant difference between the L4 and F. Results for patients younger than 60 years were the same as for all ages. Age and ICR were negatively correlated and body weight and HRT were positively correlated with the T-score for all sites (p<0.05). BMI was positively correlated with the T-score for the L4 and F (p<0.05). Based on the use of multiple regression analysis, age was negatively associated with the T-score for the L1 and F and was positively correlated for the L4 (p<0.05). Body weight was positively associated with the T-score for all sites (p<0.05). ICR was negatively associated with the T-score for the L1 (p<0.05). HRT was positively associated with the T-score for the L4 and F (p<0.05). Conclusion: The T-score and Z-score for the L4 and F were significantly higher than the scores for the L1, a finding in contrast to some previous studies on normal women. It was thought that radiation could partly influence BMD because of a higher T-score and Z-score for sites around the radiotherapy field. We suggest that a further long-term study is necessary to determine the clinical significance of these findings, which will influence the diagnosis of osteoporosis based on BMD in patients with cervical cancer who have received radiotherapy.

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF