• 제목/요약/키워드: 고온에서 고강도콘크리트의 특성

검색결과 50건 처리시간 0.026초

비소성 황토를 치환한 고강도 콘크리트의 고온 역학적 특성 평가를 위한 초음파 속도 분석 (Ultrasonic pulse velocity analysis for high- temperature mechanical properties of high strength concrete replacing non-sintered hwangto )

  • 김태형;김원창;이태규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.273-274
    • /
    • 2023
  • In this study, ultrasonic pulse velocity was analyzed to evaluate the high-temperature mechanical properties of concrete mixed with non-sintered hwangto. The W/B of the specimens was set at 0.41, the percentage of non-sintered hwangto admixture was set at two levels of 15,30%. The target temperature of the specimen is set to 6 levels of 20, 100, 200, 300, 500, 700 ℃, and the heating rate is set to 1℃/min. The result showed that the amount of non-sintered hwangto incorporated into the concrete tends to results in lower compressive strength. Ultrasonic pulse velocity showed similar trends, but differed in some areas.

  • PDF

고온 가열에 따른 섬유혼입 고강도 콘크리트의 강도특성 변화 (Strength Properties of the Fiber Mixed High Strength Concrete at Elevated Temperature)

  • 김상식;김성수
    • 한국건축시공학회지
    • /
    • 제8권5호
    • /
    • pp.53-58
    • /
    • 2008
  • This study is to investigate experimentally residual strength properties of the high strength concrete containing the hybrid of nylon and polypropylene fiber at elevated temperature. Test results showed that specimens heated up to $300^{\circ}C$ exhibited similar strength properties to the one at room temperature. This result is significantly different from previous studies. but specimens heated over $400^{\circ}C$ showed dramatic decrease indicating similar tendency. For the residual strength properties, one at $300^{\circ}C$ even increased 10%, which is also different from previous studies, but it significantly decreased in $400^{\circ}C$ as widely expected. Melted pores by organic fibers in concrete specimens was observed with FE-SEM. For the density of concrete in elevated temperature, internal system in $200^{\circ}C$ had even denser than in $20^{\circ}C$, but was collapsed in $400^{\circ}C$.

고온에서 폴리프로필렌섬유와 비정질강섬유를 보강한 150MPa급 초고강도 콘크리트의 수증기 압력특성 (The water vapor pressure property of 150MPa level ultra high strength concrete reinforced with polypropylene fiber and amorphous steel fiber at high temperature)

  • 서동균;김규용;이상규;황의철;유하민;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.132-133
    • /
    • 2020
  • The aim of this study is to evaluate the combination effect of amorphous steel fiber and polypropylene fiber on spalling of the 150MPa level ultra high strength concrete. Considering spalling has a great relationship with water vapor pressure, this paper is focusing on water vapor pressure. The test specimens were heated accordance with ISO-834 Standard Curve using electric heating furnace, the depth of 10mm water vapor pressure formation was tend to get faster and spalling damage become severe when the mixing proportion of amorphous steel fiber increase. When using ultra high strength concrete reinforced with amorphous steel fiber, further research about proper mixing proportion of polypropylene fiber.

  • PDF

비정질강섬유 보강 고강도 콘크리트의 온도별 잔존 역학적 특성 평가 (The residual mechanical properties evaluation according to temperature of the amorphous metallic fiber reinforced high strength concrete)

  • 서동균;김규용;이상규;황의철;유하민;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.98-99
    • /
    • 2020
  • This study is aim to assess mechanical properties which is highly related to structural safe and durability of 100MPa high strength concrete mixed with amorphous metallic fiber. All specimens were heated with low velocity heating rate(1℃/min.), residual compressive strength and residual flexural strength was evaluated. The specimens were cooled down to room temperature after heating. As a result, in the case of 100MPa high-strength concrete, the residual compressive strength enhancing effect of amorphous metallic fiber has showed with the mix proportion of fiber. In addition, residual flexural strength showed more regular pattern before 300℃ then residual compressive strength, but simillar decreasing behavior was shown after 300℃ like residual compressive strength. Further study about fiber pull-out behavior and fiber mechanical, chemical property change due to temperature is needed.

  • PDF

혼입 섬유종류 변화에 따른 고온가열 고강도 콘크리트의 역학적 특성 (Mechanical Properties of High Strength Concrete Subjected to Elevated Temperature Depending on Fiber Types and Contents)

  • 김상식;송용원;이보형;양성환;김성수;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.95-98
    • /
    • 2007
  • This study investigates the mechanical properties of the high strength concrete in the region of 80MPa corresponding to the temperature and fiber content change. For the properties of the fresh, slump flow is $600{\pm}100mm$, and air content is $3.0{\pm}1.0%$. They satisfy each targets, and there was no difference for the each fiber types. As the propertied of the hardened concrete, the compressive strength at 28 days is indicated over 80MPa, and they are similar to the change of the fiber types. The residual compressive strength in response to the temperature change of the NY, PP, and NY+PP fiber at $200^{\circ}C$ are increased by 115, 114, and 110% on the standard condition, and it is suddenly decreased at $400^{\circ}C$. They are decreased by 33, 19, and 16% on the standard condition at $800^{\circ}C$.

  • PDF

시멘트종류를 변화시킨 프리캐스트 고강도 콘크리트의 실험적 연구 - 수화열 온도특성을 중심으로 - (An Experimental Study of Precast concrete Alters Cement Types of High-Strength Concrete)

  • 박흥이;김성진;백민수;이승훈;박병근;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.119-122
    • /
    • 2009
  • As architectures have recently become high-risers and mega-structured, stable high strength products have been ensured. Accordingly, use of precast concrete accouplement has been increased in order to facilitate air compression and rationalize construction. Since not only external heating but a1so internal temperature rise caused by the accumulation of cement hydration heat in manufacturing process, precast concrete members with large cross-section used for high-rise mega-structure's columns and beams may exhibit different temperature history compared to the precast concrete members for wall and sub-floor with relatively small cross-sections. Therefore, this study aims to elucidate the characteristics of temperature history of mass concrete members cast with high-strength concrete fur precast concrete application. In this study, large cross-sectional precast concrete mock-up, unit cement quantity, and temperature histories in manufacturing precast concrete member under different curing condition were inclusively investigated.

  • PDF

고온시 고강도 콘크리트의 물리적 특성 모델 설정에 관한 실험적 연구 (An Experimental Study on the Physical Properties Model of High Strength Concrete at High Temperature)

  • 김흥열;서치호;최승관;전현규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.1-4
    • /
    • 2005
  • This research is to present experimental materials model of high strength concrete for prediction of fire safety of structural members based on physical properties of materials during heating up to 800$^{circ}C$. The following conclusions are drawn from this study. First of all, between 100 to 200 $^{circ}C$, the physical models of concrete such as specific heat and thermal conductivity, show visible degradation, regardless of concrete strength. Second, between 300 to 600$^{circ}C$, the physical models of the 29MPa and 49MPa concrete show degradation continually at these temperatures. Finally, beyond 600$^{circ}C$, the physical models of 49MPa strength concrete show larger degradation than 29MPa strength concrete due to rise of pore pressure and melting of the interface between aggregate and cement paste.

  • PDF

석영미분말의 입자크기가 UHPC의 유동성 및 강도에 미치는 영향 (Effect of siliceous powder's particle size on the workability and strength of UHPC)

  • 강수태;박정준;류금성;고경택;김성욱;이장화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.441-444
    • /
    • 2008
  • 본 연구에서의 초고성능 콘크리트(Ultra High Performance Concrete, UHPC)는 모래, 시멘트, 실리카퓸, 석영미분말, 강섬유 및 고성능감수제 등으로 구성되며, 평균입경 약 0.5mm이하의 아주 작은 입자들로 구성된다. 일반적으로 석영미분말는 일정크기 이상의 공극을 메움으로써 물리적 성능개선의 효과가 있으며 또한 높은 $SiO_2$함량을 가지므로 고온 또는 고압의 양생조건에서 시멘트 수화물과의 화학반응을 통해서도 성능 향상효과가 있는 것으로 알려져 있다. 본 연구에서는 상압, $90^{\circ}C$ 증기양생 조건에서 석영미분말의 입자크기가 초고성능 콘크리트의 역학적 특성에 어떠한 영향을 미치는지에 대해 알아보고자 하였으며, 평가항목으로는 굳지 않은 상태에서의 유동성과 굳은 상태에서의 압축강도, 극한변형률, 탄성계수 및 휨강도를 평가하였다. 석영미분말의 입경크기의 영향은 약 $2{\mu}m$에서 $26{\mu}m$까지의 범위에서 고려하였으며, 입경 크기가 작을수록 유동성 및 강도특성이 모두 향상되는 것으로 나타났다.

  • PDF

표준화재 재하조건하에서 Fiber Cocktail을 혼입한 고강도 콘크리트 보의 폭렬특성 및 내화성능에 관한 연구 (A Study on Fire Resistance and Spalling of HPC Beam with Fiber-Cocktail in ISO Fire under Loading Condition)

  • 조경숙;김흥열;김형준
    • 한국화재소방학회논문지
    • /
    • 제23권6호
    • /
    • pp.126-134
    • /
    • 2009
  • 본 연구는 고강도 콘크리트의 폭렬 발생을 제어하기 위하여 폭렬 저감재를 혼입함에 따른 폭렬 저감효과를 살펴보고 콘크리트 보 부재의 고온 가열시의 열적 특성을 평가하기 위하여 실시하였다. 이에 고강도 콘크리트 40~60MPa를 폭렬 저감재를 혼입하여 부재를 제작하였으며, KS F 2257의 ISO 표준화재 재하조건에서의 내화성능을 살펴보았다. 실험결과 폭렬 저감재를 혼입하지 않은 40MPa은 180분, 50MPa 174분, 60MPa 152분으로 50, 60MPa보는 기준에서 정하는 3시간 내화성능에 6~28분 부족한 것으로 나타났다. 그러나 폭렬 저감재를 혼입한 50, 60MPa 보는 모두 법에서 정하는 내화 성능 시간인 180분을 만족하였다. 폭렬 저감재를 혼입하지 않은 50, 60MPa의 콘크리트 보는 화재에 노출된 모든 면에서 폭렬이 발생되었으나 폭렬 저감재를 혼입한 50, 60MPa 보에서는 표면탈락 및 폭렬은 거의 발생되지 않았다. 따라서 콘크리트의 폭렬 방지를 위해 혼입한 PP섬유는 폭렬 방지 효과를 나타내고 있으나 60MPa 표면이 일부 탈락 된 것으로 보아 표면 탈락 방지를 위해 혼입한 강섬유는 60MPa 이상의 강도에서는 크게 효과가 나타나지 않았다.

급냉 제강 슬래그 잔골재 대체율에 따른 모르타르의 유동성 및 압축강도 특성 (The Properties of Flow and Compressive Strength of Mortar According In Replacement Ratio of Rapidly-Chilled Steel Slag Pine Aggregate)

  • 조성현;김진만;한기석;김무한
    • 콘크리트학회논문집
    • /
    • 제17권1호
    • /
    • pp.77-84
    • /
    • 2005
  • 제강 슬래그는 제강 공정에서 발생되는 부산물로서 주로 에이징 한 후 도로용 노반재로 사용된다. 제강 슬래그내에 포함된 free-CaO와 물과의 반응하여 체적팽창을 일으키기 때문에 공기중에 장시간 에이징 하는 것이 필요하다. 이러한 문제 때문에 제강 슬래그를 콘크리트용 골재로 사용하는데 어려움이 있다. 그러나, 본 연구에서는 고온의 용융상태에서 고속공기로 뿜어 급냉시킨 제강 슬래그를 사용하였다. 이와 같이 급냉시키는 방법은 제강 슬래그내의 free-CaO의 생성량을 저감시킨다. 본 연구에서는 통계적 실험계획법 중 일원배치법을 이용하여 급냉 제강 슬래그 대체율이 플로우, 고성능감수제의 첨가율, 물-시멘트비 및 압축강도 등 모르타르의 특성에 미치는 영향을 검토하였다. 또한, 이들 데이터를 분산분석 후 F-검정을 실시하여 급냉 제강 슬래그가 모르타르의 특성에 유의한 영향을 주고 있는 지를 검정하였다. F-검정결과 유의수준 $1\%$내에서 급냉 제강 슬래그 대체율이 증가할수록 모르타르의 플로우 증가, 고성능감수제 첨가율 및 물-시멘트비의 감소, 압축강도의 증진에 크게 영향을 미치는 것을 검정하였다. 또한, 유동성 및 압축강도를 고려할 때 강모래에 대하여 급냉 제강 슬래그 대체율 $75\%$를 사용하는 것이 가장 우수한 유동성과 압축강도 발현하는 것으로 나타났다.