• Title/Summary/Keyword: 고온설계

Search Result 813, Processing Time 0.029 seconds

Latch-Up Prevention Method having Power-Up Sequential Switches for LCD Driver ICs (LCD 구동 IC를 위한 Power-Up 순차 스위치를 가진 Latch-Up 방지 기술)

  • Choi, Byung-Ho;Kong, Bai-Sun;Jun, Young-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.111-118
    • /
    • 2008
  • In this paper, novel latch-up prevention method that employs power-up sequential switches has been proposed to relieve latch-up problem in liquid crystal display (LCD) driver ICs. These sequential switches are inserted in the 2'nd and 3'rd boosting stages, and are used to short the emitter-base terminals of parasitic p-n-p-n circuit before relevant boosting stages are activated during power-up sequence. To verily the performance of the proposed method, test chips were designed and fabricated in a 0.13-um CMOS process technology. The measurement results indicated that, while the conventional LCD driver If entered latch-up mode at $50^{\circ}C$ accompanying a significant amount of excess current, the driver IC adopting the proposed method showed no latch-up phenomenon up to $100^{\circ}C$ and maintained normal current level of 0.9mA.

Three-Dimensional Thermoforming Analysis of an Inner Case with Three Cavities for Refrigerator (3개의 캐비티를 가지는 냉장고 내상의 3차원 진공 열성형 해석)

  • Lee, Ho Jin;Ahn, Dong Gyu;Lee, Sang Hun;Ki, Jun Chul;Ko, Jae Hong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.5
    • /
    • pp.505-511
    • /
    • 2016
  • The aim of this study is to investigate the thermoforming characteristics of an inner case with three refrigerator cavities using three-dimensional(3D) thermoforming analyses. We perform fundamental formability analyses using a 3D model of the mould for the inner case. We carry out tensile tests at the elevated temperature to examine the properties and characteristics of the thermoformed material. Then, we design sub-processes of the thermoforming process for the inner case. In addition, we develop suitable finite-element models for different sub-processes. We investigate the deformed shapes and thickness distributions of the inner case for different sub-processes using the results of the thermoforming analysis. Finally, we discuss the formability and thermoforming characteristics of the inner case with three cavities.

Thermal Behaviors and Reaction Characteristics of an Integrated Reactor with Catalytic Combustion-Reforming According to Operation Conditions (운전조건 변경에 따른 통합형 촉매연소-개질반응기의 열적 거동 및 반응 특성)

  • Ghang, Tae-Gyu;Lee, Sang-Min;Ahn, Kook-Young;Kim, Yong-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.6
    • /
    • pp.641-648
    • /
    • 2011
  • Off-gases emitted from the anode of a molten carbonate fuel cell (MCFC) at high temperatures for power generation are used as fuel in catalytic combustion. The heat generated in the catalytic combustor is utilized as the heat for the endothermic reaction required for steam reforming. Among the various operational conditions of the integrated reactor, we varied the inlet gas compositions of the catalytic combustor according to fuel utilization in the MCFC and the ratio of steam to carbon in the reformer. Subsequently, the thermal behaviors and reaction characteristics of the integrated reactor were investigated experimentally. The fundamental data from this experimental study will be useful for the design and fabrication of a more practical integrated reactor in the future.

Fabrication and performance and stability tests of Bi-2223 pancake magnet

  • Sohn, M.H.;Cha, M.K.;Lee, J.K.;Cho, Y.S.;Ha, H.S.;Jang, H.M.;Lee, N.J.;Kim, B.J.;Kim, H.K.;Kim, Y.C.;Jeong, D.Y.
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.241-247
    • /
    • 2000
  • 77 K와 self-field에서 22 A 의 Ic 를 갖는 길이 120 m, 19-심 Bi-2223상 선재를 제조하여, 두 개의 double pancake 코일로 구성된 proto-type 고온초전도 자석을 설계, 제작하여 이 자석에서의 4.2 K와 77 K에서의 I-V 특성과 운전 특성을 평가한 결과, 이 자석은 77 K 등온조건에서는 9.5 A 의 Ic를, 77 K 헬륨가스 속에서는 8.3 A 의 Ic를 나타내었고, 4.2 K 등온조건에서는 93.7 A 의 Ic와 102 A 의 Iq를, 4.2K헬륨가스 속에서는 88.4A의 Ic 와 92.0 A 의 Iq를 나타내어, 이 자석은 4.2 K 와 77 K 의 등온조건에서 각각 0.58 T 와 0.06 T 의 자장을 발생하였는데, 이는 해석적 방법으로 계산한 결과와 잘 일치하였다. 그리고 이 자석이 전도냉각되어 4.2 K 에서 운전될 때의 안정성 특성평가로서, Ic 보다 약간 큰 전류인 89 A 를 인가한 결과, 전류인가 후 82.6초 후에 quench가 발생하였는데, 이 quench는 네 번째 pancake의 전류도입선부 연결부에서와 약간 늦지만 첫 번째 pancake의 전류도입선부 연결부에서 거의 동시에 개시되어 전체로 파급된 것으로 사료되었는데, Ic 가 낮은 첫번째 pancake에서 더 높은 전압 강하가 나타났다. 또한 장착된 heater를 통하여 77 K 에서 8.9 A 의 전류로 운전되고 있는 코일에 146 joule 의 열을 가했을 때 quench 가 일어났는데, 이때 quench 는 방위각 방향의 Bi-2223/Ag 선재를 따라서 보다 Kapton 절연층을 관통하는 선재의 반경방향으로 훨씬 빨리 전파하였다.

  • PDF

A Study on the Feeding Structure of the High-Temperature Superconducting Hairpin-comb Filter (고온초전도 헤어핀 콤 여파기의 급전 구조에 관한 연구)

  • Yun, Seok-Sun;Park, Ik-Mo;Min, Byoung-Chul;Choi, Young-Hwan;Moon, Seung-Hyun;Lee, Seung-Min;Oh, Byung-Du
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.12
    • /
    • pp.11-20
    • /
    • 1999
  • We have designed and fabricated direct-and gap-coupled microstrip hairpin-comb filters by patterning double-sided YBCO films on a single 50-mm-diameter, 0.5-mm-thick $LaAlO_3$ wafer. Both filters have a center frequency at 1.773 GHz, 12 MHz bandwidth, 0.5 dB minimum insertion loss in the passband, and very strong out-of- band rejection. Due to two attenuation poles below and above the passband, the direct-coupled hairpin-comb filter showed a better skirt characteristic than the gapcoupled hairpin-comb filter which had only one attenuation pole below the passband.

  • PDF

Study of Blank Thickness Optimization in Free Bulging for Maximizing Bulged Height (가스압력을 이용한 자유벌징에서 성형양 최대화를 위한 두께 분포 최적화)

  • Yoo, Joon-Tae;Yoon, Jong-Hoon;Lee, Ho-Sung;Youn, Sung-Kie
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.8
    • /
    • pp.899-904
    • /
    • 2014
  • Thickness profiled blank is designed using optimization techniques for maximizing the bulged heights during the free bulging of Inconel 718. The thickness of the blank was described by the Bezier curve and the locations of the control points were used as the design variables for optimization. The maximization of the bulged heights within the limited strain range served as the objective function and constraints for optimization. The equivalent static loads method for non-linear static response structural optimization (ESLSO) was used and the result of the optimization revealed 22 increased bulged heights. A free bulging test using a blank with an optimized profile was conducted to verify the optimization process. The results were compared with those of numerical analysis in terms of bulged height and deformed shape.

Experimental Study of Performance and Bubble Pattern of Air-Lift Pumps with Various Tube Diameters and Submergence Ratios (공기부양 펌프의 관직경과 잠수비 변화에 따른 기포 형상과 성능에 관한 실험적 연구)

  • Kim, Seung Hwan;Sohn, Chae Hoon;Hwang, Jun Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.9
    • /
    • pp.837-845
    • /
    • 2013
  • An airlift pump can be used to pump liquids and sediments within itself, which cannot easily be pumped up by a conventional method, by using the airlift effect. This characteristic of the airlift pump can be exploited in a DCFC (Direct Carbon Fuel Cell) so that molten fuel with high temperature may be carried or transported. The basic characteristics of airlift are investigated. A simple system is constructed, where the reservoir is filled with water, a tube is inserted, and air is supplied from the bottom of the tube. Then, water is lifted and its flow rate is measured. Bubble patterns in the tube are observed in a range of air flow rates with the parameters of the tube diameter and submergence ratio, leading to four distinct regimes. The pumping performance is predicted, and the correlation between the supplied gas flow rate and the induced flow rate of water is found.

Development of cascade refrigeration system using R744 and R404A - Prediction and comparison on maximum COP(Coefficient of Performance) - (R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(2) - 최대 성능계수에 관한 예측과 비교 -)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.189-195
    • /
    • 2011
  • In this paper, prediction and comparison on COP(coefficient of performance) of R744-R404A cascade refrigeration system are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in the R404A high- and R744 low-temperature cycle, respectively. The main results were summarized as follows : The prediction for performance of R744-R404A cascade refrigeration system have been proposed through multiple regression analysis and compared with other researcher's correlations. As a result, prediction proposed in the study shows disagreement with existing equations. Therefore, it is necessary to propose the more accurate correlation predicting the COP of R744-R404A cascade refrigeration system through an addition experiments.

Application of High-temperature 3-phase Equilibrium Distribution to Dry Scrubber for the Simultaneous Removal of $SO_2$ and Vinyl Chloride (건식세정기에서의 오염물 동시제거를 위한 고온3계평형 모델의 적용과 예비설계에의 응용)

  • 구자공;백경렬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.85-96
    • /
    • 1990
  • Simultaneous removal efficiencies of hydrophilic and hydrophobic gaseous pollutants are experimentally determined, and the macroscopic removal mechanism of pollutants in a dry scrubber is analyzed using the extended model of three phase equilibrium distribution of pollutant at high temperatures that can describe the different morphological conditions of adsorbent and water at varying relative humidities. For the simplicity, the inside of spray dryer is divided into three regions of ; (1) absorption, (2) three-phase equilibrium, and (3) adsorption, and the removal efficiencies of each pollutants at three regions are observed at different experimental conditions to estimate the effects of important parameters of dry scrubber. The laboratory experiments simulate the three regions of spray dryer with the temperature control and thus evaporation rate of water from the slurry particle. $SO_2$ as a hydrophilic gaseous pollutant and vinyl chloride as a hydrophobic toxic gas are selected for the future field application to soid waste incineration, and the two types of slurry are made of the two sorbents ; 10 wt.% $Ca(OH)_2$, and 10 wt.% NaOH. Result of temperature effect shows the height of absorption plus three-phase region is decreased as the operation temperature is increased, which results in the lower removal efficiency of $SO_2$ but higher removal for vinyl chloride in the adsorption region of dry scrubber. The removal efficiency of $SO_2$ is higher by NaOH slurry than by $Ca(OH)_2$ slurry due to the hygroscopic nature of NaOH, while the removal of vinyl chloride is higher in $Ca(OH)_2$ case. From the analysis of redults using three-phase equilibrium distribution model, the effective two-phase partition coefficients can be obtained, and the possible extention in the application of the three-phase equilibrium model in a dry scrubber design has been demonstrated.

  • PDF

A Study on the Performance Prediction of Fire Extinguish System in Aircraft Engine Bay (항공기 엔진베이 내 소화장치 성능예측을 위한 연구)

  • Park, Young-Ha;Kim, Hyung-Sik;Kim, Jin-Han;Cho, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.8
    • /
    • pp.718-725
    • /
    • 2012
  • Fuel or oil which is leaked into the aircraft engine bay can make a fire when it is contacted to the engine surface of hot temperature. In order to avoid fire, the fire extinguish system should be designed so that the extinguishing agent is quickly injected and its concentration keeps higher in the fire protection region. FAA requires that the extinguishing agent injected within the fire protection region should be sustained longer than 0.5 second on keeping a higher concentration than 6%. For developing a fire protection system satisfying the FAA regulation, numerical and experimental studies for the injection time and the concentration of the extinguishing agent were conducted. These results showed similar trend for the injection time or concentration, but the data acquisition was delayed due to the response of the sensors in the experiment.