• Title/Summary/Keyword: 고압 시험

Search Result 430, Processing Time 0.038 seconds

Development of Evaluation Technique for Hydrogen Embrittlement Behavior of Metallic Materials Using in-situ SP Testing under Pressurized Hydrogen Gas Conditions (고압수소가스하 in-situ SP시험법을 사용한 금속재료의 수소취화거동 평가기법 개발)

  • Shin, Hyung-Seop;Kim, Ki-Hyun;Baek, Un-Bong;Nahm, Seung-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.11
    • /
    • pp.1377-1382
    • /
    • 2011
  • Recently, alternative and novel energy resources have been developed for use in the future because of the current environmental problems and exhaustion of fossil energy resources. Hydrogen energy has many merits, such as its environmental friendliness, easy storage, and easy production, but it also has disadvantages, in that it is highly combustible and explosive. In this study, a test procedure using a simple SP test under highly pressurized hydrogen gas conditions was established. In order to evaluate its applicability, SP tests were carried out using a stainless steel (SUS316L) sample under atmospheric, pressurized helium, and pressurized hydrogen gas conditions. The results under the pressurized hydrogen gas condition showed fissuring and produced a reduction of the elongation in the plastic instability region due to hydrogen embrittlement, showing the effectiveness of the current in-situ SP test.

Design and Manufacture of the air mixing system for supersonic ground test facility (초음속 지상추진시험설비의 공기 혼합시스템 설계 및 제작)

  • Lee, Yagn-Ji;Kang, Sang-Hun;Yang, Soo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.40-48
    • /
    • 2008
  • Air mixing system which is composed of air pressure control system, hot pipe system and air mixer, is the facility for mixing hot air($1000^{\circ}C$, 10kg/s) from storage air heater (SAH) and decompressed air($20^{\circ}C$, 15kg/s) from high pressure air supply system. Air pressure control system reduce the pressure of the air, from 32MPa to 3.5 MPa and supply the decompressed air to air mixer. The hot pipe system supply hot air from SAH to air mixer which mix hot with the decompressed air from air pressure control system. Fully mixed air flow rate is 25kg/s and mixed temperature is up to $400^{\circ}C$. So, we can expand the operating envelop of the supersonic ground test facility to low Mach number and low altitude region.

  • PDF

High Pressure Operation Characteristics of Pilot Scale Entrained-Bed Gasification System Using ABK Coal (ABK탄을 이용한 pilot급 분류층 석탄가스화기 시스템의 고압 운전특성)

  • Chung, Seokwoo;Yoo, Sangoh;Jung, Woohyun;Lee, Seungjong;Yun, Yongseung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.105.2-105.2
    • /
    • 2010
  • 석탄의 직접 연소 대신 고온/고압의 조건에서 불완전연소 및 가스화 반응을 통하여 일산화탄소(CO)와 수소($H_2$)가 주성분인 합성가스를 제조하여 이용하는 석탄 가스화 기술은 현실적인 에너지원의 확보를 위한 방법인 동시에 이산화탄소를 저감할 수 있는 기술이라 할 수 있다. 따라서, 본 연구에서는 non-slagging 방식의 pilot급 분류층 석탄가스화기를 대상으로 고압 미분탄공급장치, 합성가스 냉각장치, 고온 집진장치 등을 연계하여 상용급 석탄가스기와 유사한 $1,300^{\circ}C$, 20 kg/$cm^2$의 운전조건에서 미분탄의 안정적인 공급을 통한 양질의 합성가스 제조 및 제조된 합성가스의 분기 공급특성 시험을 진행하였다. 그리고, 고압 미분탄공급장치는 공급호퍼에 저장된 미분탄을 고온/고압 조건으로 운전되는 석탄가스화기에 공급하기 위한 설비로서, 이러한 고압 미분탄공급장치를 이용한 기류수송 방식의 미분탄 공급 기술은 가스화기 설계 및 운전제어 기술과 더불어 석탄가스화기 시스템의 안정적 연속운전을 위한 가장 핵심적인 기술 중 하나라고 할 수 있다. 따라서, 본 연구에서는 아역청탄인 인도네시아 ABK탄을 대상으로 향후 dense phase 고압 기류수송을 목적으로 하는 고압 미분탄공급장치의 성능특성을 시험을 진행하였는데, 시험 결과 73 kg/h 조건에서 20 kg/$cm^2$의 가스화기에 대한 안정적인 미분탄 공급특성을 확인할 수 있었으며, 이러한 미분탄 공급 조건에서 CO 40~45%, $H_2$ 16~20%, $CO_2$ 5~8% 조성의 양질의 합성가스를 평균적으로 $230{\sim}50Nm^3/h$ 안정적으로 제조할 수 있었다.

  • PDF

A life test of metal halide and high pressure sodium lamp according to voltage variation (전원전압 변동에 따른 메탈핼라이드램프와 고압나트륨램프의 수명시험)

  • Chee, Chol-Kon;Yi, Chin-Woo;Cho, Ho-Yon;Ahn, Jae-Hyuk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.228-229
    • /
    • 2006
  • 본 논문에서는 250W 메탈핼라이드램프와 250W 고압나트륨램프에 대하여 전원전압 변동에 따른 수명측정시험을 수행하였다. 시험 전압은 220V와 220V의 80%인 176V 두 가지 전압을 사용하였다. 시험 방법은 100시간 에이징 후, 일주일마다 광속을 측정하였다. 전원전압을 변경하여 연속점등시 조도측정시험 결과는 메탈핼라이드램프의 경우 정격전압의 80%에서는 정격전압의 경우보다 초기광속의 70%에 도달하는 시간이 약 30% 단축되는 것으로 조사되었다. 그러나 고압나트륨램프의 경우는 전압변동과 수명과의 관계를 파악할 수 없었다.

  • PDF

A Study on the Construction of Test circuit and Unification of Experiment Method for High Voltage Gas-insulated Load Switch using High Power Testing System (특고압 가스 절연 부하 개폐기의 통합형 대전력 시험 방법 및 회로 구성에 관한 연구)

  • Jung, Heung-Soo;Kim, Min-Young;Kim, Juen-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.36-46
    • /
    • 2008
  • This paper is to study on the Construction of Test circuit and Unification of Experiment Method for high voltage gas-insulated load switch using high power testing system The high power testing system is a equipment to verify electrical and mechanical performance on electrical product. The system consist of short-circuit generator, back-up breaker, making switch, impedance, high voltage transformer, low voltage transformer, measuring and protection system, etc. Using this system, we can test related to high power, for example, short-time current test, active load Current test, magnetizing Current test, capacitive current test, closed loop current test, etc. Standards of high voltage gas-insulated load switch that is in use domestic distribution line are ES 5925-0002, IEC 60265-1, IEC 62271-1 and IEEE C 37.74, etc. In this paper, we standardized on the test procedure, organization of test circuit and analysis of measured data prescribed many difference standards, and applied this test method to 600[MVA] high power testing system. So that we can test the load switch satisfied standards.

Temporary Over Voltage Test System for Surge Protective Device in Low Distribution system (배전계통의 순간전압 상승에 따른 SPD 고압 TOV 시험설비 구축)

  • Kim, Young-Sung;Kim, Oun-Seok;Ahn, Gun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1391_1392
    • /
    • 2009
  • 본 논문에서는 저압 서지보호기의 안전성평가를 위한 고압 계통 고장에 의한 순간 과전압시험 설비를 IEC 61643-1의 따라 구축 하였고, 구축된 시험설비의 성능을 분석하였다. 고압 계통의 순간 과전압시험 기준은 가장 일반적인 미국전력 계통의 기준인 3상 4선식이 반영이 되었으며 전압의 크기는 AC 1200V이다. 본 논문에서는 순간과전압이 상과 접지사이의 개방전압 AC 1200V을 약 200ms 동안 인가되는지를 측정하였고, 단락전류가 AC 300A이상을 측정하였다.

  • PDF

A study on revision of international standard(IEC62271-105) (퓨즈 부착 고압교류 부하개폐기의 국제규격(IEC62271-105) 개정에 관한 검토)

  • Suh, Yoon-Taek;Rhyou, Hyeong-Kee;Kim, Dae-Won;Yoon, H.D.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.537-539
    • /
    • 2003
  • 퓨즈 부착 고압 교류부하개폐기(Alternating current switch-fuse combination)는 개폐기와 한류형 퓨즈의 조합으로서 각각의 규격(개폐기는 IEC60265-1, 한류형 퓨즈는 IEC60282-1)에 따른 개발시험을 실시 한 후 휴즈부착 고압교류 부하개폐기의 규격인 IEC62271-105에 따라 개발시험이 이루어진다. 본 논문에서는 최근에 개정된 IEC62271-105의 신구 비교, 시험종류 및 시험방법에 대해서 기술하였다.

  • PDF

Characterization Test of Sub-Modules for High Voltage DC Transmission System-Based Modular Multi-Level Converter (고압 직류송전망을 위한 모듈형 멀티레벨 컨버터의 서브모듈 특성시험)

  • Seo, Dong-Woo;Jeong, Jong-Kyou;Jung, Hong-Ju
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.344-345
    • /
    • 2019
  • High Voltage Direct Current (HVDC) 시스템은 고압 직류 송전을 위한 시스템으로서 단위 유닛인 서브모듈로 구성된 모듈형 멀티레벨 컨버터 구조를 갖는다. 서브모듈의 신뢰성 확보 및 설계 검증은 HVDC 시스템의 성능과 효율, 크기를 결정짓는 중요한 요소이다. 본 논문에서는 (주)효성이 개발하는 200MW 모듈형 멀티레벨 컨버터 서브모듈의 성능을 검증하기 위한 특성시험을 나타낸다. 특성시험을 통해서 개발 중인 서브모듈의 성능과 보호동작을 검증한다.

  • PDF

Rupture Safety Assesment of Bipropellant Propulsion System at High Pressure Testing (이원 추진 시스템 고압 시험시의 파열 안전성 고찰)

  • Chang, Se-Myong;Han, Cho-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.6
    • /
    • pp.605-611
    • /
    • 2010
  • The geostationary satellite COMS is going to be launched in 2010, and, in the series of test, there are some high-pressure tests concerning the vessel tank filled with helium gas of hundreds atmospheric pressure. In this paper, authors evaluates risk associated with accidental rupture of the test system. Two possible scenarios are considered: 1) the 310-bar helium tank ruptures at the center of the acoustic chamber, and 2) the 116-bar reduced-pressure helium tank ruptures in the test room shielded by bullet-proof glasses. Using the theory of blast wave propagation and computational simulation, the dynamics of wave reflected in a confined space is investigated for highly complex unsteady flow physics.

Evaluation on Behavior of Hydraulic Cycling Test for Type3 Hydrogen Composite Cylinder (수소복합재용기 TYPE3에 대한 수압반복 거동 평가)

  • Cho, Sung Min;Lee, Seung Hoon;Lyu, Geun Jun;Kim, Young Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.98.2-98.2
    • /
    • 2011
  • 지구 온난화의 원인이 되는 이산화탄소를 저감하며 유해한 배기가스를 배출하지 않는 수소연료전지자동차(FCV)에 대한 관심이 높아지고 있다. 한국가스안전공사에서 현재 구축하고 있는 평가장비는 이러한 수소연료전지자동차용으로 사용되는 고압용기의 수압반복시험 및 밸브류로 구성된 고압수소저장시스템의 단품 및 시스템 평가를 통한 안전신뢰성 검증을 목적으로 하고 있다. 현재 수소연료전지자동차는 차량이나 부품의 시험 방법에 대한 통일된 기준/표준/시험법이 아직 완전하게 정비되어 있지 않고, 시장에서의 도입 제도, 기준 등이 만들어지고 있는 현실이다. 또한 연료로 수소를 사용하는 도입단계에 있기 때문에, 수소용기가 반복압력변동에 따라 어떤 거동을 나타내는지에 대한 실험관련 연구가 미진한 상태이다. 따라서 수소연료전지자동차용 고압수소저장시스템에 대한 내구성, 안전성 확보를 위하여 수소연료전지자동차에서 중요한 부품인 용기에 대한 반복피로시험이 필요하다. 특히 복합재 용기 분야에서 Type3용기에 대한 높은 안전성과 내구성이 보고되고 있지만 실질적으로 얼마나 다른 용기에 비해 높은 성능을 가지고 있는지 국내에서는 체계적으로 검증된바 없다. 따라서 구축된 수압반복 장비를 이용하여 Type3 용기에 대한 수압반복시험을 실시하였으며, 이를 통해 수소용기의 거동을 확인하고자 한다.

  • PDF