• Title/Summary/Keyword: 고압송전

Search Result 59, Processing Time 0.036 seconds

Prediction of Electromagnetic Noise using Spatial Modelling in Magnetotellurics (공간 모델링을 이용한 자기지전류 탐사의 전자기 잡음 예측)

  • Lee, Choon-Ki;Lee, Heui-Soon;Kwon, Byung-Doo
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.4
    • /
    • pp.251-261
    • /
    • 2005
  • The quality of MT (magnetotellurics) data highly depends on the level of artificial noise form industrial sources. We have conducted the feasibility study of MT noise modelling using digital spatial data and spatial modelling through the comparison between the predicted and the measured MT noises. A simple noise model predicting the intensity of electromagnetic field radiated from the latent noise sources, that is, the electric facilities in the building, road and high-voltage powerline, is developed in consideration of the propagation property of electromagnetic waves. From the analysis of correlation between the predicted and the measured noise power, the correlation coefficients of electric field are higher than those of magnetic field in whole frequency band. The magnetic field component has the high correlation in the narrow band near 60 Hz only. The spatial noise modelling proposed in this study would provide some useful informations for the MT surveys in the noisy environment like urban area.

Study about the Applicable Plan of GIS on Range of Magnetic Field Emitted from 60 Hz Powerline (60Hz 고압 송전선로의 자기장 발생범위에 대한 GIS 적용 방안에 대한 연구)

  • Hong, Seung Cheol;Choi, Seong Ho;Kim, Yoon Shin;Park, Jae Young
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.4
    • /
    • pp.271-277
    • /
    • 2006
  • In this study, we investigated the applicable plan of GIS on the environmental impact assessment of 60 Hz Powerline. So we assessed distance data based on calculations by use of 2D and 3D Geographical information systems(GIS) and distance data based on measurements on 1: 5000 maps accord with on site distance measurements to use input data for calculating magnetic field. One hundred eight of the on site measured addresses were selected from residences. The data were achieved by measuring the distance between residence and power line on maps with scales of 1: 5000. The digital map was obtained from National Geographic Information Institute with scales of 1: 5000, and we made 2D and 3D map. Correlation analyses were performed for statistical analyses. For the 3D GIS versus on site comparison of different exposure categories, 70 of 108 measurements were assigned to the correct category. Similarly for 2D GIS versus on site comparison, 71 of 108 were correctly categorized. When comparing map measurement with on site measurement, 62 of 108 were correctly categorized. When the correlation analysis was performed, best correlation was found between 3D GIS and on site measurements with r = 0.84947 (p<0.0001). The correlation between map and on site measurement yielded an r of 0.76517 (p<0.0001). Since the GIS measurements and map measurement were made from the center point in the building and the on site measurements had to be made from the closest wall on the building, this might introduce and additional error in urban areas. The difference between 2D and 3D calculations were resulted from the height of buildings.

Identification of Normally Operating High-Voltage Cables beyond Expected Life time (예상 수명을 초과하여 정상적으로 동작하는 고압 케이블의 확인)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.5
    • /
    • pp.207-212
    • /
    • 2015
  • Continuous, high-quality supply of electrical energy is the backbone of any modern economy. Any equipment operating at a power station must be reliable and safe. All major power supply components such as transformers, cables, generators, and switchgear need to be kept in perfect operating condition. The lifetime of power cables, used as the main means of transferring electric power, is understood to be about 30 years, from the time of manufacturing. The dielectrics between two conductors of a cable must be able to withstand electrical stresses from high-voltage input. This condition should be verified throughout the lifetime of the cable system. Several techniques, such as VLF-tan${\delta}$, partial discharge, and insulation resistance are used in order to determine the operating conditions of cables. In this paper, we present our work on insulation resistance to diagnose cables in operation at the Western Power station in Taean, Chungcheong Namdo Province, South Korea. As a result we have found cables the life time of which is 38 years.

Analysis of Internal Energy Pulsation in MMC System According to Offset Voltage Injection with PWM Methods (PWM 방식을 이용한 옵셋 전압 주입에 따른 MMC 시스템 내부 에너지 맥동 분석)

  • Kim, Jae-Myeong;Jung, Jae-Jung
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1140-1149
    • /
    • 2019
  • In general, there are various pulse width modulation(PWM) methods simply using the offset voltage injection in voltage source converter(VSC). In accordance with the AC side voltage synthesis method with the offset voltage, DC side voltage utilization factor in VSC is changed. Also, this can apply equally to the MMC system. In other words, if the DC side capacity of the high voltage DC(HVDC) transmission system is determined, the maximum reactive power which can be supplied to the AC side can be changed according to the applied output voltage synthesis method with the offset voltage. In this paper, the leg energy pulsation in MMC system according to the AC side output voltage synthesis method with offset voltage which several representative PWM are applied to are mathematically analyzed and compared with each other. Finally, the above results are verified by simulation emulating the 400MVA full-scale MMC system to determine the consistency of the mathematical analysis.

Study about Prediction Model to Extremely Low Frequency Magnetic Fields for the Selected Primary Schoolchildren Nearby High Voltage Power Line (고압 송전선로 주변에 위치한 초등학교 학생들의 극저주파 자기장 노출량 예측 모델에 관한 연구)

  • Kim, Yoon-Shin;Hyun, Youn-Joo;Choi, Seong-Ho;Roh, Young-Man;Hong, Seung-Cheol
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.506-514
    • /
    • 2006
  • The objectives of this study were to evaluate personal exposure estimated using a time activity pattern and microenvironmental model. The study was carried out for 44 children attending a primary school nearby the lines (school A) and 125 children attending a school away from 154 kV power lines (school B). For children attending school A, the estimated personal level was a little weak correlated with the measured level($Pearson\;r\;=0.34{\sim}0.35$). For children attending school B, the correlation was very low ($Pearson\;r\;=\;0.09{\sim}0.16$) using the TW A Model II, otherwise, TWA Model II-I which considered the average residential MF level according to the distance from the power line and home explained $39{\sim}53%$ of the correlation in MF personal exposures. The estimated personal exposure level was very well represented by the measured exposure level using TWA Model II-2 which consisted on spot and 24 h stationary measurements at subject's home ($Pearson\;r\;=\;0.65{\sim}0.85$). In conclusion, personal magnetic field expsoure estimated using a TWA Model II-2 should be provided for a reasonable estimate of measured exposure in schoolchildren living near the power line.

SSD-based Fire Recognition and Notification System Linked with Power Line Communication (유도형 전력선 통신과 연동된 SSD 기반 화재인식 및 알림 시스템)

  • Yang, Seung-Ho;Sohn, Kyung-Rak;Jeong, Jae-Hwan;Kim, Hyun-Sik
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.777-784
    • /
    • 2019
  • A pre-fire awareness and automatic notification system are required because it is possible to minimize the damage if the fire situation is precisely detected after a fire occurs in a place where people are unusual or in a mountainous area. In this study, we developed a RaspberryPi-based fire recognition system using Faster-recurrent convolutional neural network (F-RCNN) and single shot multibox detector (SSD) and demonstrated a fire alarm system that works with power line communication. Image recognition was performed with a pie camera of RaspberryPi, and the detected fire image was transmitted to a monitoring PC through an inductive power line communication network. The frame rate per second (fps) for each learning model was 0.05 fps for Faster-RCNN and 1.4 fps for SSD. SSD was 28 times faster than F-RCNN.

A Study on the Calculation of Allowable Continuous Current for HVDC Submarine Power Cables (HVDC 해저케이블의 연속허용전류 계산에 관한 연구)

  • Lim, Chung-Hwan;Park, Hung-Sok;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.815-824
    • /
    • 2022
  • The growing integration of intermittent renewable sources like offshore wind energy increases the need for transferring electric energy over long distances, which may include sea crossings. One of the solutions available for bulk electric power transmission across large distances encompassing wide and deep sea is using HVDC submarine power cables. However, there are no standards or research related to the calculation of the continuous allowable current with various ocean conditions of a DC power cable that does not have an alternating magnetic field. In this study, assuming the typical two types of subsea cable models and two areas of the south coast and the west coast marine conditions, a continuous allowable current simulation of DC cables was performed. As a simulation result, the DC cable continuous allowable current find out the gradient reduction characteristics based on subsea base depth.

Evaluation of the Magnetic Field Exposure Level in 60 Hz High Voltage Transmission Lines Nearby Residential Area (60 Hz 고압송전선로 인접 주거지역의 자기장 노출수준 평가)

  • Hong, Seung-Cheol;Jung, Joon-Sig;Kim, Keun-Young;Park, Hyun-Ju;Choi, Sung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.1
    • /
    • pp.27-33
    • /
    • 2008
  • In order to evaluate the magnetic field (MF) exposure level in residential areas near high voltage power lines, this research measured MF levels at 120 sites near high voltage transmission lines in the Busan region, Gwangju region, Daegu region and Changwon region from July to December, 2005, and compared and analyzed the efficiencies by measuring and applying the MF emission levels of underground cables and high voltage transmission lines. As a result of the investigation of the MF exposure level by the building usage, the average MF level of 17 locations at schools was $2.44{\pm}2.45mG;$ that of 10 locations at hospitals $6.21{\pm}12.39mG;$that of 76 locations at apartments $2.55{\pm}2.98mG;$ and that at kindergartens and infant houses $3.32{\pm}4.21mG$. MF exposure was analysed as a function of distance from the source and the MF levels directly below a source were $5.15{\pm}8.72mG$, those within 30 m were $3.10{\pm}3.32mG$, while those within 50 m were $2.45{\pm}2.38mG$, and within 100 m were $0.71{\pm}0.93mG$. In order to determine the difference of MF levels by the actual distance from high voltage transmission line within the same building, the evaluation of the floor position and the MF level has shown that the MF levels were highest in the order of roof, 4th floor, 3rd floor, 2nd floor and 1st floor. Comparison of MF emission intensity of underground cables and high voltage transmission lines, has shown that underground cables have an 86-94% of reduction ratio in MF compared to high voltage transmission lines, thus demonstrating higher efficiency.

Development of Simulation Model for Modular Multilevel Converters Using A Dynamic Equivalent Circuit (동적 등가 회로를 이용한 MMC의 시뮬레이션 모델 개발)

  • Shin, Dong-Cheoul;Lee, Dong-Myung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.17-23
    • /
    • 2020
  • This paper proposes a simulation model using an equivalent circuit for the development of an MMC system. The MMC has been chosen as the most suitable topology for high voltage power transmission, such as a voltage-type HVDC, and it has dozens to hundreds of sub-modules in the form of a half-bridge or full-bridge connected in series. A simulation study is essential for the development of an MMC algorithm. On the other hand, it is virtually impossible to construct and implement MMC simulation models, including hundreds or thousands of switching devices. Therefore, this paper presents an MMC equivalent model, which is easily expandable and implemented by modeling the dynamic characteristics. The voltage and current equation of the equivalent circuit was calculated using the direction of the arm current and switching signal. The model was implemented on Matlab/Simulink. In this paper, to show the validity of the model developed using Matlab/Simulink, the simulation results of a five-level MMC using the real switching element and the proposed equivalent model are shown. The validity of the proposed model was verified by showing that the current and voltage waveform in the two models match each other.