• Title/Summary/Keyword: 고분자수용액

Search Result 4, Processing Time 0.017 seconds

The Performance Evaluation of Red Clay Binder with Polymer Aqueous Solution (고분자수용액을 첨가한 황토 결합재의 성능 평가)

  • Kim, Jin-Sung;Kim, Ho-Jin;Choi, Hyeong-Gil
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.141-142
    • /
    • 2020
  • In this study, the performance evaluation was performed by adding a polymer aqueous solution as a new additive of the red clay binder for use in the rammed earth construction method. The evaluation items were compressive strength and microstructure analysis. As a result of the experiment, the performance of the red clay binder was improved by efficiently bonding the silica particles by the polymerized polymer.

  • PDF

A Study on the Characteristics of Flow with Polymer Additives (고분자물질 첨가에 의한 유동특성에 관한 연구)

  • 차경옥;김재근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.176-186
    • /
    • 1996
  • The phenomena of drag reduction using small quantities of a liner macromolecules has attracted the attention of many experimental investigations. On the other hand drag reduction in two phase flow can be applied to the transport of crude oil, phase change system such as chemical reactor, pool and boiling flow, and to flow with cavitation which occurs pump impellers. But the research on dragreduction in two phase flow is not sufficient. The purpose of the present work is to evaluate the drag reduction by measuring pressure drop, void fraction, mean liquid velocity and turbulent intensity whether polymer additives a horizontal single and two phase system or not. Flow pattern of air-water two phase flow was classified by electrical conductivity probe signal. Velocities and turbulent intensities of signal were measured simultaneously with a Hot-film anemometer.

  • PDF

A flow phenomenon of aquaous polymer solution in couette flow of concentric cylinder with wide circular (넓은 환상간극을 가진 동심원통속의 couette 흐름에서 고분자수용액의 유동현상)

  • 권혁칠;이성노;정진도
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.81-88
    • /
    • 1993
  • This report describes the experimental research on the flow phenomena of the aq uaous polymer solution within the Cuette flow of the concentric, cylinders type with a wide circular gap. We have investigated the phenomena of the fluid flow through torque measuring in the system that the inner cylinder is stationary and the outer one is rotating. Geometrical parameters of the system are the gap ratio of t/R$_{0}$=0.2 and Aspect ratio of l/t=100. The torque increases considerably in about 420-480RPM, So, it is considered a turbulent transition boundary, the higher plymer concentration is, the lower torque value is and the higher transition Reynolds number is. In each of the polymer concentration, the unstable boundary of torque, that is, idiosyncrasies of torque is observed around 220-280RPM. and the boundary is looked upon as a resonant vibration which is caused by the inner cylinder and tortional vibration of torque sensor.r.

  • PDF

A study on the drag reduction in a horizontal two phase flow (수평 2상유동에서 마찰저항감소에 관한 연구)

  • Cha, Gyeong-Ok;Kim, Jae-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.4
    • /
    • pp.1472-1480
    • /
    • 1996
  • The phenomena of drag reduction using small quantities of a linear macromolecules has attracted the attention of experimental investigations. It is well known that drag reduction in single phase liquid flow is affected by polymer materials, molecular weight, polymer concentration, pipe diameter and flow velocity. But the research on drag reduction in two phase flow has not intensively investigated. Drag reduction can be applied to phase change system such as chemical reactor, pool and boiling flow, and to flow with cavitation which occurs pump impellers. The purpose of the present work is to evaluate the drag reduction by measuring pressure drop, mean liquid velocity, and turbulent intensity and determine the effects of polymer additives on drag reduction in horizontal two phase flow. Experimental results show higher drag reduction using co-polymer comparing with using polyacrylamide. Mean liquid velocities increase as adding more polymer, and turbulent intensities decrease as the distance for the wall in inversed.