• Title/Summary/Keyword: 고려의학

Search Result 972, Processing Time 0.038 seconds

Study on Glomerular Filtration Rate comparison according to renal depth measurement of kidney donors (신 공여자에서 신장 깊이 측정에 따른 사구체여과율의 비교에 관한 고찰)

  • Lee, Han Wool;Park, Min Soo;Kang, Chun Goo;Cho, Seok Won;Kim, Joo Yeon;Kwon, O Jun;Lim, Han Sang;Kim, Jae Sam;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.48-56
    • /
    • 2014
  • Purpose $^{99m}Tc$-DTPA renal scintigraphy serves as a key indicator to measure a kidney donor's Glomerular Filtration Rate (GFR) and determine the possibility of kidney transplant. The Gates method utilized to measure GFR considers 3 variables of renal depth, injection dose, and net kidney counts. In this research, we seek to compare changes in kidney donors' GFR according to renal depth measurement methods of the 3 variables. Materials and Methods We investigated 32 kidney donors who had visited the hospital from October, 2013 to March, 2014 and received abdominal CT and $^{99m}Tc$-DTPA GFR examination. With the cross-section image of the CT and the lateral image from a gamma camera, we measured the renal depth and compared with renal depth calculation equations-Tonnesen, Taylor, and Itoh methods. Renal depth-specific GFR was calculated by using Xeleris Ver. 2.1220 of GE. Then the results were compared with MDRD (Modification of Diet Renal Disease) GFRs based on serum creatinine level. Results The renal depths measured based on the CT and gamma camera images showed high correlation. Tonessen equation gave the lowest GFR value while the value calculated by using the renal depth of CT image was the highest with a 16.62% gap. MDRD GFR showed no statistically significant difference among values calculated through Taylor, Itoh, CT and gamma camera renal depth application (P>0.05), but exhibited a statistically significant change in the value based on Tonnesen equation (P<0.05). Conclusion This research has found that, in GFR evaluation in kidney donors by utilizing $^{99m}Tc$-DTPA, Tonnesen equation-based Gates method underestimated the value than the MDRD GFR. Therefore, if a MDRD GFR value shows a huge difference from the actual examination value, using an image-based renal depth measurement, instead of Tonnesen equation applied to Gates method, is expected to give an accurate GFR value to kidney donors.

  • PDF

A Case Study about PET/CT Collaboration Operation (PET/CT 공동운영에 대한 사례 연구)

  • Kim, Chang-Ho;Pyo, Sung-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.87-92
    • /
    • 2010
  • Purpose: In 2003, we decided to buy a PET/CT, at the time, it was the latest cancer diagnostic medical equipment. Equipment company was offered the marketing of collaboration operation because the highly cost of PET/CT. However, this hospital's choice was own purchase way. In this study we evaluated the collaboration operation way by post-mortem analysis to the current situation. Materials and Methods: From 2004 until 2008, five years, we investigate the revenue analysis the number of PET/CT cases about own purchase way and collaboration operation way according (ABC costing). Results: The year 2004, own purchase way is 4 billion 9 thousand 2 hundred million won in deficit, the collaboration operation way is 1 billion 1 thousand 7 hundred million won in deficit. The year 2005, own purchase way is 1 billion 5 hundred million won in deficit, collaboration operation way is 8 thousand 7 hundred million won in deficit. However, the year 2006, own purchase way is 5 billion 1thousand 3 hundred million won in surplus, collaboration operation way is 9 thousand 9 hundred million won in deficits. The year 2007 and 2008, revenue of own purchase way is more increased but the collaboration operation way is more decreased. From the year 2004 to 2008, subtotal of own purchase way is 10 billion 8 thousand 8 hundred won in surplus, sub-total of collaboration operation way is 6 billion 7 thousand million won in deficit. Conclusion: Own purchase way has been a big benefit occurs and to reflect the equipment price, the collaboration operation way became to deficit continues. In other words, the problem of collaboration operation way showed us. When you buy the high cost Equipment, consideration will be risk and economic analysis of variance, the appropriate of the initial investment cost, clinical diagnostic needs and etc.

  • PDF

Metal artifact SUV estimation by using attenuation correction image and non attenuation correction image in PET-CT (PET-CT에서 감쇠보정 영상과 비감쇠보정 영상을 통한 Metal Artifact 보정에 대한 고찰)

  • Kim, June;Kim, Jae-II;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.21-26
    • /
    • 2016
  • Purpose Because of many advantages, PET-CT Scanners generally use CT Data for attenuation correction. By using CT based attenuation correction, we can get anatomical information, reduce scan time and make more accurate correction of attenuation. However in case metal artifact occurred during CT scan, CT-based attenuation correction can induce artifacts and quantitative errors that can affect the PET images. Therefore this study infers true SUV of metal artifact region from attenuation corrected image count -to- non attenuation corrected image count ratio. Materials and Methods Micro phantom inserted $^{18}F-FDG$ 4mCi was used for phantom test and Biograph mCT S(40) is used for medical test equipment. We generated metal artifact in micro phantom by using metal. Then we acquired both metal artifact region of correction factor and non metal artifact region of correction factor by using attenuation correction image count -to- non attenuation correction image count ratio. In case of clinical image, we reconstructed both attenuation corrected images and non attenuation corrected images of 10 normal patient($66{\pm}15age$) who examined PET-CT scan in SNUH. After that, we standardize several organs of correction factor by using attenuation corrected image count -to- non attenuation corrected count ratio. Then we figured out metal artifact region of correction factor by using metal artifact region of attenuation corrected image count -to- non attenuation corrected count ratio And we compared standard organs correction factor with metal artifact region correction factor. Results according to phantom test results, metal artifact induce overestimation of correction factor so metal artifact region of correction factors are 12% bigger than the non metal artifact region of correction factors. in case of clinical test, correction factor of organs with high CT number(>1000) is $8{\pm}0.5%$, correction factor of organs with CT number similar to soft tissue is $6{\pm}2%$ and correction factor of organs with low CT number(-100>) is $3{\pm}1%$. Also metal artifact correction factors are 20% bigger than soft tissue correction factors which didn't happened metal artifact. Conclusion metal artifact lead to overestimation of attenuation coefficient. because of that, SUV of metal artifact region is overestimated. Thus for more accurate quantitative evaluation, using attenuation correction image count -to-non attenuation correction image count ratio is one of the methods to reduce metal artifact affect.

  • PDF

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

Tegumental ultrastructure of juvenile and adult Echinostoma cinetorchis (이전고환극구흡충 유약충 및 성충의 표피 미세구조)

  • 이순형;전호승
    • Parasites, Hosts and Diseases
    • /
    • v.30 no.2
    • /
    • pp.65-74
    • /
    • 1992
  • The tegumental ultrastructure of juvenile and adult Echinostoma cinetorchis (Trematoda: Echinostomatidae) was observed by scanning electron microscopy. Three-day (juvenile) and 16-day (adult) worms were harvested from rats (Sprague-Dawley) experimentally fed the metacercariae from the laboratory-infected fresh water snail, Hippeutis cantori. The worms were fifed with 2.5% glutaraldehyde, processed routinely, and observed by an ISI Korea DS-130 scanning electron microscope. The 3-day old juvenile worms were elongated and ventrally curved, with their ventral sucker near the anterior two-fifths of the body. The head crown was bearing 37∼38 collar spines arranged in a zigzag pattern. The lips of the oral and ventral suckers had 8 and 5 type II sensory papillae respectively, and bewteen the spines, a few type III papillae were observed. Tongue or spade-shape spines were distributed anteriorly to the ventral sucker, whereas peg-like spines were distributed posteriorly and became sparse toward the posterior body. The spines of the dorsal surface were similar to those of the ventral surface. The 16-day old adults were leaf-like, and their oral and ventral suckers were located very closely. Aspinous head crown, oral and ventral suckers had type II and type III sensory papillae, and numerous type I papillae were distributed on the tegument anterior to the ventral sucker. Scale-like spines, with broad base and round tip, were distributed densely on the tegument anterior to the ventral sucker but they became sparse posteriorly. At the dorsal surface, spines were observed at times only at the anterior body. The results showed that the tegument of E. cinetorchis is similar to that of other echinostomes, but differs in the number and arrangement of collar spines, shape and distribution of tegumenal spines, and type and distribution of sensory papillae.

  • PDF

The Patient Recognition, Acceptability and Evaluation of Feasibility for Day Surgery (종합병원 일부 입원환자의 당일수술에 대한 태도와 당일수술 적용 가능성 평가)

  • Beak, Young-Ran;Lee, Kyeong-Soo;Kim, Seok-Beom;Kang, Pock-Soo;Kang, Young-Ah
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.3
    • /
    • pp.334-342
    • /
    • 2000
  • Objectives . This study was conducted in order to investigate the degree of recognition, acceptability, and altitude towards day surgery of patients who were hospitalized with diseases that were candidates for day surgery; in order to analyze the average length of stay for treatment of the ailments; and to analyze the percentage of patients who could be discharged on the same day after the surgery ,using the post-anesthesia discharge scoring system. Methods : Data was collected between February 1 and March 31, 1999 from 353 patients who received surgery for cataract, adenoid hypertrophy, inguinal hernia, strabismus, ptosis, cholelithiasis, hemorrhoid, or anal fistula, at a general hospital in Daegu city. The patients were interviewed and surveyed by a post-anesthesia discharge scoring system(PADS) in order to collect data on patient condition such as vital signs, activity and mental status, pain, nausea and vomiting, surgical bleeding, intake and output after the surgery. Results : Among the 353 patients, 52.7% were after of the day surgery and 52.7% were interested in day surgery. Of the respondents, 43.1% said 'my ailment was not serious and the surgery was simple' and 30.4% said 'according to my condition rest at home was desirable' as the reasons for wanting day surgery Alternatively, 56.5% of those declining day surgery said the 'uncertainty of staying home' was the reason. The greatest concern in discharging within 24 hours after surgery was a post-op emergency situation. On the other hand, the shortened hospitalization was the largest advantage of day surgery with 39.1% responding this way, followed by the savings in hospitalization costs (25.8%) and emotional stability (13.7%). The majority of those surveyed (47.6%) believed that discharge should be determined within 1-2 days after the surgery. The average hospital stay was 3.1 days for dischargeable ailments. Pain (45.6%), nausea and vomiting (10.5%), and headache (7.9%) were the common symptoms following surgery. The percentage of patients who were able to be discharged within 24 hours after surgery revealed 95.2% were dischargeable after approximately 3 hours, 99.2% dischargeable after 12 hours, and 100% dischargeable after 24 hours. Conclusions : According to the PADS score, the cataract extract and strabismus correction patients were eligible for day surgery and the further evaluation concerning the reason for delayed recovery of the other diseases is needed.

  • PDF

Improved Image Quality and Radiation Dose Reduction in Liver Dynamic CT Scan with the Protocol Change (Liver CT 검사에서 프로토콜 변화에 따른 선량 감소와 영상의 질 개선에 관한 연구)

  • Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.107-114
    • /
    • 2015
  • The purpose is reducing radiation dose while maintaining of image quality in liver dynamic CT(LDCT) scan, by protocols generally used and the tube voltage set at a low level protocol compared to the radiation dose and image quality. The target is body mass index, 18.5~24 patients out of 40 patients who underwent the ACT(abdominal CT). Group A(tube voltage : 120kVp, SAFIRE strength 1) of 20 people among 40 people, to apply the general abdominal CT scan protocol, group B(tube voltage : 100kVp, apply SAFIRE strength 0~5) was 20 people, set a lower tube voltage. Image quality evaluation was setting a region of interest(ROI) in the liver parenchyma, aorta, superior mesenteric artery (SMA), celiac trunk, visceral fat of arterial phase. In the ROI were compared by measuring the noise, signal to noise ratio(SNR), contrast to noise ratio(CNR), CT number. In addition, qualitative assessments to evaluate two people in the rich professional experience in Radiology by 0-3 points. We compared the total radiation dose, dose length product(DLP) and effective dose, volume computed tomography dose index(CTDIvol). The higher SAFIRE in the tube voltage 100 kVp, noise is reduced, CT number was increased. Thus, SNR and CNR was increased higher the SAFIRE step. Compared with the tube voltage 120kVp, noise, SNR, CNR was most similar in SAFIRE strength 2 and 3. Qualitative assessment SAFIRE strength 2 is the most common SAFIRE strength 2 the most common qualitative assessment, if the tube voltage of 100kVp when the quality of the images better evaluated was SAFIRE strength 1. Dose was reduced from 21.69%, in 100kVp than 120kVp. In the case of a relatively high BMI is not LDCT scan, When it is shipped from the factory tube voltage is set higher, unnecessary radiation exposure when considering the reality that is concerned, when according to the results of this study, set a lower tube voltage and adjust the SAFIRE strength to 1 or 2, the radiation without compromising image quality amount also is thought to be able to be reduced.

Improving Diagnostic Accuracy for Malignant Nodes and N Staging in Non-Small Cell Lung Cancer Using CT-Corrected FDG-PET (비소세포폐암에서 CT-보정 양전자단층촬영술을 이용한 악성 림프절 평가 및 N 병기 결정 성적 향상)

  • Lee, Eun-Jeong;Choi, Joon-Young;Lee, Kyung-Soo;Chung, Hyun-Woo;Lee, Su-Jin;Cho, Young-Seok;Choi, Yong;Choe, Yearn-Seong;Lee, Kyung-Han;Kwon, O-Jung;Shim, Young-Mog;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.231-238
    • /
    • 2005
  • Purpose: We investigated prospectively whether the interpretation considering the patterns of FDG uptake and the findings of unenhanced CT for attenuation correction can improve the diagnostic accuracy for assessing malignant lymph node (LN) and N stage in non-small cell lung cancor (NSCLC) using CT-corrected FDG-PET (PET/CT). Materials & Methods: Subjects were 91 NSCLC patients (M/F 62/29, age: $60{\pm}9$ yr) who underwent PET/CT before in dissection. We evaluated the maximum SUV (maxSUV), patterns of FDG uptake, short axis diameter, and calcification of LN showing abnormally increased FDG uptake. Then we investigated criteria improving the diagnostic accuracy and correlated results with postoperative pathology. In step 1, in was classified as benign or malignant based on maxSUV only. In step 2, LN was regarded as benign if it had lower maxSUV than the cut-off value of step 1 or it had calcification irrespective of its maxSUV. In step 3, LN regarded as malignant in step 2 was classified as benign if they had indiscrete margin of FDG uptake. Results: Among 432 LN groups surgically resected (28 malignant, 404 benign), 71 showed abnormally increased FDG uptake. We determined the cut-off as maxSUV=3.5 using ROC curve analysis. The sensitivity, specificity, and accuracy for assessing malignant LN were 64.3%, 86.9%, 85.4% in step 1, 64.3%, 95.0%, 93.1% in step 2, and 57.1%, 98.0%, 95.4% in step3, respectively. The accuracy for assessing N stage was 64.8% in step 1, 80.2% in step 2, and 85.7% in step 3. Conclusion: interpreting PET/CT, consideration of calcification and shape of the FDG uptake margin along with maxSUV can improve the diagnostic accuracy for assessing malignant involvement and N stage of hilar and mediastinal LNs in NSCLC.

Development of a Comprehensive Model of Disaster Management in Korea Based on the Result of Response to Sampung Building Collapse (1995), - Disaster Law, and 98 Disaster Preparedness Plan of Seoul City - (우리나라 사고예방과 재난관리 모형 개발을 위한 연구)

  • Lee, In-Sook
    • Research in Community and Public Health Nursing
    • /
    • v.11 no.1
    • /
    • pp.289-316
    • /
    • 2000
  • 우리나라의 경우 지역사회 재난 관리계획과 훈련이 보건의료적 모형이라기 보다는 민방위 모형에 입각하기 때문에 사고 현장에서의 환자 중증도 분류, 합리적 환자배분 및 이송, 병원 응급실에서의 대처 등이 체계적으로 이루어지지 못하고 있으며, 지역사회가 이에 즉각적으로 반응할 수 없다. 본 연구는 삼풍 붕괴사고 시에 대응방식과 그 후의 우리나라 응급의료 체계를 분석함으로써 대형사고 예방과 재난관리를 위한 우리나라 응급의료체계의 개선방안과 간호교육에서의 준비부분을 제시하고자 한다. 1 삼풍 사고 발생시에는 이를 관장할 만한 법적 근거인 인위적 재해에 관한 재난관리법이 없었다. 따라서 현장에서는 의학적 명령체계를 확보하지 못했기 때문에 현장에서의 응급 처치는 전혀 이루어지지 못하였다. 현장에서의 중증도 분류. 응급조치와 의뢰, 병원과 현장본부 그리고 구급차간의 통신 체계 두절, 환자 운송 중 의료지시를 받을 수 있도록 인력, 장비, 통신 체계가 준비되지 못하였던 점이 주요한 문제였다. 또한 병원 응급실에서는 재난 계획이 없거나 있었더라도 이를 활성화하여 병원의 운영 체계를 변환해가지 못하였다. 2. 삼풍백화점 붕괴사고 한달 후에는 인위적 재해에 대한 재난관리법이 제정되고, 행정부 수준별로 매년 지역요구에 합당한 재난관리 계획을 세우도록 법으로 규정하였다. 재난 관리법에는 보건의료 측면에서의 현장대응, 주민 참여, 응급 의료적 대처, 정보의 배된. 교육/훈련 등이 포함되어 있어야 한다. 그러나 법적 기반이 마련된 이후에도 한국 재난 계획 내에는 응급의료 측면의 대응 영역은 부처간 역할의 명시가 미흡하며, 현장에서의 응급 대응과정을 수행할 수 있는 운영 지침이 없이 명목상 언급으로 그치고 있기 때문에 계획을 활성화시켜 지역사회에서 운영하기는 어렵다. 즉 이 내용 속에는 사고의 확인 /공고, 응급 사고 지령, 요구 평가, 사상자의 중증도 분류와 안정화, 사상자 수집, 현장 처치 생명보존과 내과 외과적 응급처치가 수반된 이송, 사고 후 정신적 스트레스 관리, 사고의 총괄적 평가 부분에 대한 인력간 부처간 역할과 업무가 분명히 제시되어 있지 못하여, 사고 발생시 가장 중요한 연계적 업무 처리나 부문간 협조를 하기 어렵다. 의료 기관과 응급실/중환자실, 시민 안전을 책임지고 있는 기관들과의 상호 협력의 연계는 부족하다. 즉 현재의 재난 대비 계획 속에는 부처별 분명한 업무 분장, 재난 상황에 따른 시나리오적 대비 계획과 이를 훈련할 틀을 확보하고 있지 못하다. 3. 지방 정부 수준의 재난 계획서에는 재난 발생시 보건의료에 관한 사항 전반을 공공 보건소가 핵심적 역할을 하며 재난 관리에 대처해야 된다고 규정하고 있다. 그러므로 보건소는 지역사회 중심의 재난 관리 계획을 구성하고 이를 운영하며, 재난 현장에서의 응급 치료 대응 과정은 구조/ 구명을 책임지고 있는 공공기관인 소방서와 지역의 응급의료병원에게 위임한다. 즉 지역사회 재난 관리 계획이 보건소 주도하에 관내 병원과 관련기관(소방서. 경찰서)이 협동하여 만들고 업무를 명확히 분담하여 연계방안을 만든다. 이는 재난관리 대처에 성공여부를 결정하는 주요 요인이다. 4 대한 적십자사의 지역사회 주민에 대한 교육 프로그램은 연중 열리고 있다. 그러나 대부분의 교육주제는 건강증진 영역이며. 응급의료 관리는 전체 교육시간의 8%를 차지하며 이중 재난 준비를 위한 주민 교육 프로그램은 없다. 또한 특정 연령층이 모여있는 학교의 경우도 정규 보건교육 시간이 없기 때문에 생명구조나 응급처치를 체계적으로 배우고 연습할 기회가 없으면서 국민의 재난 준비의 기반확대가 되고 있지 못하다. 5. 병원은 재난 관리 위원회를 군성하여 병원의 진료권역 내에 있는 여러 자원을 감안한 포괄적인 재난관리계획을 세우고, 지역사회를 포함한 훈련을 해야 한다. 그러나 현재 병원은 명목상의 재난 관리 계획을 갖고 있을 뿐이다. 6. 재난관리 준비도를 평가할 때 병원응급실 치료 팀의 인력과 장비 등은 비교적 기준을 충족시키고 있었으나 병원의 재난 관리 계획은 전혀 훈련되고 있지 못하였다 그러므로 우리나라 재난 관리의 준비를 위해서는 현장의 응급의료체계, 재난 대응 계획, 이의 훈련을 통한 주민교육이 선행되어야만 개선될 수 있다. 즉 민방위 훈련 모델이 아닌 응급의료 서비스 모델에 입각한 장기적 노력과 재원의 투입이 필요하며, 지역사회를 중심으로 대응 준비와 이의 활성화 전략 개발, 훈련과 연습. 교육에 노력을 부여해야 한다. 7. 현장의 1차 응급처치자에 대해서는 법적으로 명시하고 있는 역할이 없다. 한국에서는 응급구조사 1급과 2급에 대한 교육과 규정을 1995년 이후 응급의료에 관한 법률에서 정하고 있다. 이 교육과정은 미국이 정하고 있는 응급구조사 과정 기준과 유사하지만 실습실이나 현장에서의 실습시간이 절대적으로 부족하다. 덧붙여 승인된 응급구조사 교육 기관의 강사는 강사로서의 자격기준을 충족할 뿐 아니라 실습강사는 대체적으로 1주일의 1/2은 응급 구조차를 탑승하여 현장 활동을 끊임없이 하고 있으며, 실습은 시나리오 유형으로 진행된다. 그러므로 우리나라의 경우 응급 구조사가 현장 기술 인력으로 역할 할 수 있도록 교과과정 내에서 실습을 강화 시켜야하며, 졸업생은 인턴쉽을 통한 현장 능력을 배양시키는 것이 필요하다. 8. 간호사의 경우 응급전문간호사의 자격을 부여받게 됨에 따라, 이를 위한 표준 교육 지침을 개발함으로써 병원 전 처치와 재난시 대응할 수 있는 역량을 보완해야 한다. 또한 현 자격 부여 프로그램 내용을 고려하여 정규자격 간호사가 현장 1차 치료자(first responder)로 역할 할 수 있도록 간호학 교과과정을 부분 보완해야한다.

  • PDF

The Usefulness of Measurement of Whole Body Count in Assessing Bone Marrow Metastasis in Cancer Patients with Increased Periarticular Bone Uptake on Follow-up Bone Scan: A Comparison with Bone Marrow Scan (암환자의 추적 골스캔에서 관절주위 섭취증가시 전신골섭취계수 측정이 골수전이 평가에 도움이 되는가-골수스캔과의 비교)

  • Jin, Seong-Chan;Choi, Yun-Young;Cho, Suk-Shin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.428-436
    • /
    • 2003
  • Purpose: Increased periarticular uptake could be associated with peripheral bone marrow expansion in cancer patients with axial bone marrow metastasis. We compared bone scan and bone marrow scan to investigate whether the increased whole body count in patients with increased periarticular uptake on bone scan is useful in the diagnosis of axial marrow metastasis, and evaluate the role of additional bone marrow scan in these cases. Materials and methods: Twelve patients with malignant diseases who showed increased periarticular uptake on bone scan were included. Whole body count was measured on bone scan and it is considered to be increased when the count is more than twice of other patients. Bone marrow scan was taken within 3-7 days. Results: Five hematologic malignancy, 3 stomach cancer, 2 breast cancer, 1 prostate cancer and 1 lung cacner were included. All three patients with increased whole body count on bone scan showed axial marrow suppression and peripheral marrow expansion. Eight of 9 patients without increased whole body count showed axial marrow suppression and peripheral marrow expansion. One turned out to be blastic crisis of chronic myelogeneous leukemia, and seven showed normal axial marrow with peripheral marrow expansion in chronic anemia of malignancy. The last one without increased whole body count showed normal bone marrow scan finding. Conclusion: Increased whole body count on bone scan could be a clue to axial bone marrow metastasis in cancer patients with increased periarticular uptake, and bone marrow scan is a valuable method for differential diagnosis in these cases.