• 제목/요약/키워드: 고단열

검색결과 33건 처리시간 0.028초

고기밀 고단열 주택의 기밀성능에 관한 실험적 연구 (Experimental Study on Airtightness Performance of the House with High Levels of Insulation and Airtight Construction)

  • 신우철;윤종호;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.61-67
    • /
    • 2005
  • The purpose of this study is to evaluate the air tightness of Zero Energy Solar House(ZeSH) and to propose the construction improvement of junctions and penetrations where air infiltration was identified. Air leakage rate were measured by means of blower door test in accordance with ASTM E779-87. The results showed that ZeSH has an excellent airtightness with ACH50/20 (air change per hour at a pressure difference of 50 Pa between inside outside) of 0.34hr-1 and leakage class E by normalized leakage area of ASHRAE.

수도 고단백 돌연변이계통에 관한 연구 (Studies on the High Protein Mutants of Rice)

  • 한창열;원종락
    • 한국작물학회지
    • /
    • 제20권
    • /
    • pp.63-68
    • /
    • 1975
  • (1) 진흥에 방사선을 처리하여 얻은 고단백돌연변이계통(1974년에 M$_4$세대, 종자는 M$_{5}$)들에 대해 3개지역에서 특성조사, 단위면적당단백질수량, 종자의 수량조사등을 실시하였고, 한편 (2) 호광에서 얻은 고단백이면서 단간, 조열인 변이계통 398(1974년에 M$_{10}$ , 종자는 M$_{11}$)에 대해 변이형질들을 지배하는 인자와 이의 다발성(또는 연관)여하를 구명하기 위해 이를 모품종과 교잡하여 F$_1$mF$_2$세대에 있어서 변이형질들의 발현 및 분리를 조사하였다. 1. 진흥유래의 고단백변이계통들의 단배질함량은 년차 및 지역간에 변이는 있으나 모품종에 비해 모두 높고 종자수량은 모품종과 비슷하거나 증가되었다. 2. 이들의 열기는 5-10일 단축되었고, 간장은 1계통을 제외하고는 단간화되었고 엽 및 수수도열병의 저항성은 비교적 강한 편이었다. 2. 이들의 숙기는 5-10일 단축되었고, 간장은 1계통을 제외하고는 단간화되었고, 엽 및 수수도열병의 저항성은 비교적 강한 편이었다. 3. 고단백변이계통 398과 모품종 호광과의 F$_1$에서 간장, 숙기는 양친의 중간형으로 나타났다. F$_2$에서 단간, 조숙이면서 저단백인 것이 분리되어 고단백인자와 기타 변이형질과는 독립적으로 유전되는ㄱ서 같으나 F$_2$세대와 F$_3$종자가 비정상적 환경하에서 생육 및 성숙했기 때문에 확실치 않고, 정확한 것은 비상환경에서 자란 F$_2$세대에서 밝혀질 것이다.

  • PDF

환기시스템을 갖춘 온돌 성능에 관한 연구 (A Study on the Performance of Ondol with a Ventilation System)

  • 전성택;조진표
    • 한국산학기술학회논문지
    • /
    • 제15권7호
    • /
    • pp.4047-4051
    • /
    • 2014
  • 현대의 공동 주택은 에너지 효율을 높이기 위해 고기밀, 고단열 방식으로 지어지고 있는데 이러할 경우 환기량 부족에 따른 각종 부작용이 발생을 한다. 본 연구에서는 우리나라의 겨울철 대표적인 난방원으로 사용되고 있는 온돌시스템을 기본으로 구성하고 환기방법에 따른 실내 열환경을 평가하여 환기 방식에 따른 에너지 절감 요인을 분석하였다. 실험장치는 일정한 외기 조건을 모사하기 위해 항온항습 챔버에 뜬바닥 온돌 시스템을 설치하고 온돌시스템의 외기온도/습도 조건은 3조건($10^{\circ}C$/50%Rh, $0^{\circ}C$/-, $-10^{\circ}C$,-)으로 설정 하였다. 공급되는 온수온도는 2 조건($60^{\circ}C$, $50^{\circ}C$) 설정하여 설정된 환기 방식에 따라 성능시험을 수행 하여 열 환경 및 에너지 절감 요인을 비교 분석 하였다. 실험결과 급기온도는 온수온도가 높을수록 급기풍량이 적을수록 높았으며 바닥 급/배기 > 전열교환 급/배기 > 강제 급/배기 순으로 나타났다. 본 연구를 통해 다양한 환기 방식의 적용 가능성에 대하여 검토 할 수 있었다.

평행류형 열교환기를 이용한 분리형 히트파이프의 성능에 관한 연구 (Study on the Performance of the Separate type Heat Pipe Using the Parallel Flow type Heat Exchanger)

  • 전성택;조진표
    • 한국산학기술학회논문지
    • /
    • 제16권8호
    • /
    • pp.5045-5050
    • /
    • 2015
  • 현대 주택이 고기밀 고단열로 건축되기 때문에 에너지 절감의 이점이 있는 반면 오염된 공기로 인한 많은 부작용이 발생하고 있다. 이런 부작용을 해결하기 위해 환기장치를 사용하여 실내 공기 환경을 개선하고 있다. 본 연구에서는 자동차용 에어컨의 열교환기로 사용되고 있는 평행류형 열교환기의 배기열 회수 환기장치로 적용 가능성을 알아보기 위해 냉매 충진량에 따른 열교환 효율 특성을 시험적으로 평가 하였다. 본 연구에서 사용된 히트 파이프는 환기장치에 적용이 가능하도록 분리형으로 제작되었다. 작동유체는 R22 냉매이고 유체의 충진량은 40~60(%vol.)로 10(%vol.) 단위로 충진 하였다. 환기량은 전면풍속을 기준으로 0.3~1.5m/s로 0.3 m/s 간격으로 바꿔 가며 측정하였다. 시험결과 최대 효율을 가지는 냉매 충진량이 환기량에 따라 다름을 알 수 있었고, 실험 결과 분석을 통하여 분리형 히트파이프의 환기량에 따른 최적 냉매 충진량을 찾을 수 있었다.

식이 단백질 수준이 납중독된 흰쥐의 혈청 및 조직의 무기질 함량에 미치는 영향 -I . 납, 철, 구리 함량에 미치는 영향- (Effect of Dietary Level on Pb, Fe, and Cu Level of the Tissue of the Pb-administered Rats)

  • 이정숙;조수열;김석환
    • 한국식품영양과학회지
    • /
    • 제18권4호
    • /
    • pp.389-397
    • /
    • 1989
  • 납중독된 흰쥐의 무기질 축적과 식이 단백질 수준과의 관계를 관찰하기 위해 흰쥐에게 납 2,000ppm을 함유한 식수를 제한없이 주면서, 식이 단백질수준을 6%(저단백납급여군), 15(중단백납급여군), 40%(고단백납급여군)로 하여 각 3주, 7주동안 사육시켜 얻은 결과는 다음과 같다. 납급여군들의 체중 증가는 대조군에 비해 적었으나, 간, 신장, 비장, 뇌의 단위 체중당 무게는 대조군에 비해 증가하였다. Hematocrit치, hemoglobin 함량, RBC수는 납급여군들이 대조군에 비해 감소하였으며, 식이내 단백 수준이 낮을 수록 감소하는 경향을 보였다. 혈청, 간의 단백질 함량은 저단백납급여군이 대조군에 비해 감소하였다. 혈청, 간, 신장의 납 축적량은 저단백납급여군이 유의적으로 높았다. 철의 함량은 혈청에서는 고단백납급여군이 높게 나타난 반면, 간에서는 저단백납급여군이 높게 나타났다. 구리의 함량은 혈청 내에서는 각 군 사이에 유의성이 없었고, 간에서는 저단백납급여군은 대조군과 비슷했으나, 고단백납급여군, 중단백납급여군은 대조군에 비해 감소하는 것으로 나타났다.

  • PDF

공동주택 세대내 발코니 유형별 창호의 냉난방 에너지 성능분석 연구 (A Study on the Energy Performance Evaluation of Window System with the Balcony Types of Apartments)

  • 윤종호;안영섭;김병수;황상근
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.83-90
    • /
    • 2007
  • Apartment balcony has been indiscreetly remodeled since the government permitted remodeling on January 2006. But remodeled balcony has a few problems such as increase of heating energy, surface condensation and cold draft. The reason of thermal problem is mainly caused by the window system in a extended balcony. The purpose of this study is to analyze heating and cooling energy and propose the efficient window types for the extended balcony area of a apartment building. 4 types of window system which have fairly high U value in Korea are investigated as follows ; double clear glass, double low-e glass, triple clear glass and triple low-e glass. Comparing double clear 91ass with double low-e glass, triple clear glass and triple low-e glass, simulation results show that 10%, 7% and 15% saving of total primary energy can be expected.

확장형 발코니 공동주택의 창호종류에 따른 결로 및 온열환경에 관한 연구 (A Study on the Condensation and Thermal Environment according to Window Systems Types Installed for a Extended-Balcony Apartment)

  • 윤종호;안영섭;김병수
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.87-92
    • /
    • 2007
  • As expansion of balconies at apartments has been legalized, the major function of the balconies as a thermal buffer zone is disappearing. This weakens the ability of window to insulate heat and multiplies surface condensation. Thus more and more residents require solutions to increasing surface condensation and aggravation in thermal comfort. This study intends to provide basic data by evaluating performance of triple layered Low-E windows, triple layered clear windows, double layered Low-E windows and double layered clear window used for expanded balconies and marketed within the country in terms of surface condensation and thermal environment through simulation. Results revealed that no surface condensation occurred at double layered Low-E windows and triple layered Low-E windows. Surface condensation took place at double layered clear windows and triple layered clear windows at a relative humidity of 60%. Thermal environment analysis suggested that double layered clear windows showed the most time falling into the range of comfort at $23^{\circ}C$. The figure were $22^{\circ}C$ for triple layered clear windows, $22^{\circ}C$ for double layered Low-E windows and $21^{\circ}C$ for triple layered Low-E windows.

자철광 및 철분말을 혼입한 고열전도 콘크리트의 열전도 평가 및 해석기법 비교에 대한 연구 (Study on Analysis Technique Comparison and Evaluation of High Thermal Conductivity Concrete with Magnetite Aggregates and Steel Powder)

  • 이학수;김민규;권성준
    • 콘크리트학회논문집
    • /
    • 제26권3호
    • /
    • pp.315-321
    • /
    • 2014
  • 콘크리트는 경제적이면서 내구적인 건설재료로서 고단열성능을 가지고 있으므로 RC 구조물 뿐 아니라 내외장재에 많이 사용되고 있다. 또한 우수한 방사선 차폐 성능을 가지고 있으므로 원전구조물 및 플랜트 구조에 사용되고 있다. 그러나 이러한 고단열 성능으로 인해 내부에 원전구조물 내부에 화재나 멜트다운(melt-down)과 같은 문제가 발생하면 외부에서 인공적으로 온도를 낮출 방법이 매우 제한적이다. 이 연구는 자철광 골재와 철분말을 이용하여 고열전도 콘크리트를 제조하고 이에 대한 역학적 성능과 열전도 특성을 평가하였다. 자철광 골재를 체적비 최대 42.9%, 철분말을 1.5% 혼입하여 열전도 특성을 분석하였다. 자철광골재의 체적비가 30% 수준까지는 큰 열전도가 평가되지 않았으나, 이후 선형적으로 증가하여 체적비 42%가 되었을 때, 열전도는 2.5배 수준으로 증가하였다. 또한 철분말을 포함한 경우는 포함하지 않은 경우에 비해 열전도가 106~113% 증가하였다. 기존의 열전도 모델(ACI, DEMM, MEM)의 결과들이 실험 결과와 비교되었으며, 이러한 모델들은 자철광 및 철분말이 함유된 고열전도 콘크리트에 대해서도 합리적으로 적용될 수 있음을 검증하였다.

WUFI 시뮬레이션 프로그램을 이용한 목조주택 벽체 레이어 구성에 따른 hygrothermal 성능 평가 (Evaluation of The Hygrothermal Performance by Wall Layer Component of Wooden Houses Using WUFI Simulation Program)

  • 강유진;김수민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.75-84
    • /
    • 2016
  • 건물에너지 저감에 효과적으로 기여하는 건축 재료를 이용하는 목조주택을 기반으로 단열 성능이 향상되고 있다. 그러나 고단열 고기밀화로 인한 습기 제어가 어려워져 외벽의 결로 및 곰팡이 발생으로 인하여 성능이 저하될 수 있다. 이에 열 습기 시뮬레이션 프로그램을 이용하여 선정한 5가지 형태의 목조주택 외벽의 열 습기 성능, 결로 발생 및 곰팡이 성장 위험을 평가하였다. 목조주택은 농촌주택 표준설계도 '10과 '14, $2^{{\prime}{\prime}}{\times}6^{{\prime}{\prime}}$형, EIFS 그리고 목조형 패시브 하우스로 선정하였고, 각 벽체 레이어를 구성에 따라 벽 A, B, C, D, E로 구분하였다. 벽체의 열관류율은 각각 0.171, 0.172, 0.221, 0.150, $0.079W/m^2K$이다. 벽 A와 C의 OSB 절대함수량은 기준치 20%를 초과하는 값이 나타났고, 결로 평가를 통하여 단열재 내부 표면에서 겨울철에 결로가 발생할 수 있음을 확인하였다. 벽 D와 E는 외단열 벽체로 다른 벽체에 비하여 함수량 평가와 결로 평가에서 우수한 결과를 보여주었다. 그러나 곰팡이 성장 위험 평가에서 5가지 형태의 벽체 모두 곰팡이 성장 위험성이 있음을 확인하였다. 이에 따라 외벽의 열 습기 성능의 차이는 열적 성능에 의한 발생보다는 레이어 구성에 따른 차이가 발생하는 것으로 판단되었다. 모든 벽체는 비슷한 열적 성능을 가지고 있으나 레이어에 따라 동일한 조건에서의 적합성이 다르게 나타나는 것을 확인하였다.