• Title/Summary/Keyword: 계획표적체적

Search Result 95, Processing Time 0.025 seconds

The Analysis of Predictive Factors for the Identification of Patients Who Could Benefit from Respiratory-Gated Radiotherapy in Non-Small Cell Lung Cancer (비소세포성 폐암에서 호흡동기방사선치료 적용 환자군의 선택을 위한 예측인자들의 분석)

  • Jang, Seong-Soon;Park, Ji-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.228-239
    • /
    • 2009
  • Purpose: 4DCT scans performed for radiotherapy were retrospectively analyzed to assess the possible benefits of respiratory gating in non-small cell lung cancer (NSCLC) and established the predictive factors for identifying patients who could benefit from this approach. Materials and Methods: Three treatment planning was performed for 15 patients with stage I~III NSCLC using different planning target volumes (PTVs) as follows: 1) PTVroutine, derived from the addition of conventional uniform margins to gross tumor volume (GTV) of a single bin, 2) PTVall phases (patient-specific PTV), derived from the composite GTV of all 6 bins of the 4DCT, and 3) PTVgating, derived from the composite GTV of 3 consecutive bins at end-exhalation. Results: The reductions in PTV were 43.2% and 9.5%, respectively, for the PTVall phases vs. PTVroutine and PTVgating vs. PTVall phases. Compared to PTVroutine, the use of PTVall phases and PTVgating reduced the mean lung dose (MLD) by 18.1% and 21.6%, and $V_{20}$ by 18.2% and 22.0%, respectively. Significant correlations were seen between certain predictive factors selected from the tumor mobility and volume analysis, such as the 3D mobility vector, the reduction in 3D mobility and PTV with gating, and the ratio of GTV overlap between 2 extreme bins and additional reductions in both MLD and $V_{20}$ with gating. Conclusion: The additional benefits with gating compared to the use of patient-specific PTV were modest; however, there were distinct correlations and differences according to the predictive factors. Therefore, these predictive factors might be useful for identifying patients who could benefit from respiratory-gated radiotherapy.

Assessment of the Usefulness of an IMRT Plan Using a Shell-Type Pseudo Target with Patients in Stage III or IV of NSCLC (비소세포폐암 III, IV기 환자에 있어서 Shell-Type Pseudo Target을 이용한 세기 조절 방사선치료계획기법의 유용성 평가)

  • Lee, Sang-Bong;Park, Ki-Ju;Park, Du-Chan;Kim, Man-Wo;Kim, Jun-Gon;Noh, Sung-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.95-106
    • /
    • 2012
  • Purpose: The objective of this study was to investigate the usefulness of an IMRT treatment plan according to whether there was a shell-type pseudo target during radiation therapy for patients in Stage III or IV of non-small cell lung cancer (NSCLC). Materials and Methods: After setting an IMRT (Intensity-Modulated Radiation Therapy, IMRT) plan for when there was a shell-type pseudo target (SPT) and when there was none (WSPT) with 22 patients in Stage III or IV of NSCLC, the investigator analyzed dose-volume histograms (DVHs) and made assessment with dosimetric comparisons such as homogeneity index (HI) inside the tumor target, conformity index (CI) of the tumor target, spinal cord maximum dose, Esophagus $V_{50%}$, mean lung dose (MLD), and $V_{40%}$, $V_{30%}$, $V_{20%}$, $V_{10%}$, $V_{5%}$. Results: The mean CI of WSPT and SPT was $1.22{\pm}0.04$ and $1.16{\pm}0.032$ ($.000^*$), respectively, and the mean HI of WSPT and SPT was $1.06{\pm}0.015$ and $1.07{\pm}0.014$ ($.000^*$), respectively. In SPT, the mean of each CI difference decreased by $-5.16{\pm}2.54%$, while HI increased by average $0.81{\pm}0.47%$. Esophagus $V_{50%}$ recorded $14.54{\pm}12.01%$ (WSPT) and $12.14{\pm}11.09%$ ($.000^*$, SPT) with the mean of SPT differences dropping by $-26.37{\pm}25.05%$. Mean spinal cord maximum dose was $3,898.44{\pm}1,075.0$ cGy (WSPT) and $3,810.8{\pm}1,134.9$ cGy ($.004^*$, SPT) with SPT dropping by average $-3.36{\pm}5.81%$. As for lung $V_{X%}$, the mean of $V_{5%}$ and $V_{10%}$ differences was $-1.62{\pm}2.29%$ ($.006^*$) and $-1.98{\pm}5.02%$ ($.005^*$), respectively with SPT making a decrease. The mean of V20%, V30%, and V40% differences was $-3.51{\pm}3.07%$ ($.000^*$), $-4.84{\pm}6.01%$ ($.000^*$), and $-6.16{\pm}8.46%$ ($.001^*$), respectively, with SPT making a decrease with statistical significance. In MLD assessment, SPT also dropped by average $-2.83{\pm}2.41%$ ($.000^*$). Those results show that SPT allows for mean 169 cGy (Max: 547 cGy, Min: 6.4 cGy) prescription dose. Conclusion: An IMRT treatment plan with SPT during radiation therapy for patients in Stage III or IV of NSCLC will help to reduce the risk of lung toxicity and radiation-induced pneumonia by cutting down radiation doses entering the normal lung, reduce the local control failure rate during radiation therapy due to increasing prescription doses to a certain degree, and increase treatment effects.

  • PDF

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

Study on the Photoneutrons Produced in 15 MV Medical Linear Accelerators : Comparison of Three-Dimensional Conformal Radiotherapy and Intensity-Modulated Radiotherapy (15 MV 의료용 선형가속기에서 발생되는 광중성자의 선량 평가 - 3차원입체조형방사선치료와 세기조절방사선치료의 비교 -)

  • Yang, Oh-Nam;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.335-343
    • /
    • 2012
  • Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photonueutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photonbeams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.

Estimation of Secondary Scattered Dose from Intensity-modulated Radiotherapy for Liver Cancer Cases (간암환자에 대한 세기조절방사선치료에서의 2차 산란선량평가)

  • Kim, Dong Wook;Sung, Jiwon;Lee, Hyunho;Yoon, Myonggeun;Chung, Weon Kuu;Bae, Sun Hyun;Shin, Dong Oh;Chung, Kwangzoo;Lim, Young Kyung;Shin, Donho;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.295-302
    • /
    • 2013
  • We estimated secondary scattered and leakage doses for intensity-modulated radiotherapy (IMRT), volumetric arc therapy (VMAT) and tomotherapy (TOMO) in patients with liver cancer. Five liver patients were planned by IMRT, VMAT and TOMO. Secondary scatter (and leakage) dose and organ equivalent doses (OEDs) are measured and estimated at various points 20 to 80 cm from the iso-center by using radiophotoluminescence glass dosimeter (RPLGD). The secondary dose per Gy from IMRT, VMAT and TOMO for liver cancer, measured 20 to 80 cm from the iso-center, are 0.01~3.13, 0.03~2.34 and 0.04~1.29 cGy, respectively. The mean values of relative OED of secondary dose of VMAT and TOMO for five patients, which is normalized by IMRT, measured as 75.24% and 50.92% for thyroid, 75.14% and 40.61% for bowel, 72.30% and 47.77% for rectum, 76.21% and 49.93% for prostate. The secondary dose and OED from TOMO is relatively low to those from IMRT and VMAT. OED based estimation suggests that the secondary cancer risk from TOMO is less than or comparable to the risks from conventional IMRT and VMAT.

Influence of Delayed Gastric Emptying in Radiotherapy after a Subtotal Gastrectomy (위부분절제술 후 방사선치료에서 음식물 배출지연에 따른 영향)

  • Kim, Dong-Hyun;Kim, Won-Taek;Lee, Mi-Ran;Ki, Yong-Gan;Nam, Ji-Ho;Park, Dal;Jeon, Ho-Sang;Jeon, Kye-Rok;Kim, Dong-Won
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.194-200
    • /
    • 2009
  • Purpose: This aim of this study was to evaluate changes in gastric volume and organ position as a result of delayed gastric emptying after a subtotal gastrectomy performed as part of the treatment of stomach cancer. Materials and Methods: The medical records of 32 patients who underwent concurrent chemoradiotherapy after a subtotal gastrectomy from March 2005 to December 2008 were reviewed. Of these, 5 patients that had more than 50 cc of residual gastric food detected at computed tomography (CT) simulation, were retrospectively enrolled in this study. Gastric volume and organ location was measured from CT images obtained before radiotherapy, twice weekly. In addition, authors evaluated the change of radiation dose distribution to planning the target volume and normal organ in a constant radiation therapy plan regardless of gastric volume variation. Results: A variation in the gastric volume was observed during the radiotherapy period (64.2~340.8 cc; mean, 188.2 cc). According to the change in gastric volume, the location of the left kidney was shifted up to 0.7 - 2.2 cm (mean, 1.2 cm) in the z-axis. Under-dose to planning target volume (V43, 79.5${\pm}$10.4%) and over-dose to left kidney (V20, 34.1${\pm}$12.1%; Mean dose, 23.5${\pm}$8.3 Gy) was expected, given that gastric volume change due to delayed gastric emptying wasn't taken into account. Conclusion: This study has shown that a great change in gastric volume and left kidney location may occur during the radiation therapy period following a subtotal gastrectomy, as a result of delayed gastric emptying. Detection of patients who experienced delayed gastric emptying and the application of gastric volume variation to radiation therapy planning will be very important.

Treatment Margin Assessment using Mega-Voltage Computed Tomography of a Tomotherapy Unit in the Radiotherapy of a Liver Tumor (간종양 방사선치료 시 토모테라피 메가볼트 CT를 이용한 치료 여백 평가)

  • You, Sei-Hwan;Seong, Jin-Sil;Lee, Ik-Jae;Koom, Woong-Sub;Jeon, Byeong-Chul
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.280-288
    • /
    • 2008
  • Purpose: To identify the inter-fractional shift pattern and to assess an adequate treatment margin in the radiotherapy of a liver tumor using mega-voltage computed tomography (MVCT) of a tomotherapy unit. Materials and Methods: Twenty-six patients were treated for liver tumors by tomotherapy from April 2006 to August 2007. The MVCT images of each patient were analyzed from the $1^{st}$ to the $10^{th}$ fraction for the assessment of the daily liver shift by four groups based on Couinard's proposal. Daily setup errors were corrected by bony landmarks as a prerequisite. Subsequently, the anterior-, posterior-, right-, and left shifts of the liver edges were measured by maximum linear discrepancies between the kilo-voltage computed tomography (KVCT) image and MVCT image. All data were set in the 2-dimensional right angle coordinate system of the transverse section of each patient's body. Results: The liver boundary shift had different patterns for each group. In group II (segment 2, 3, and 4), the anterior mean shift was $2.80{\pm}1.73\;mm$ outwards, while the left mean shift was $2.23{\pm}1.37\;mm$ inwards. In group IV (segment 7 and 8), the anterior-, posterior-, right-, and left mean shifts were $0.15{\pm}3.93\;mm$ inwards, $3.15{\pm}6.58\;mm$ inwards, $0.60{\pm}3.58\;mm$ inwards, and $4.50{\pm}5.35\;mm$ inwards, respectively. The reduced volume in group II after MVCT reassessment might be a consequence of stomach toxicity. Conclusion: Inter-fractional liver shifts of each group based on Couinard's proposal were somewhat systematic despite certain variations observed in each patient. The geometrical deformation of the liver by respiratory movement can cause shrinkage in the left margins of liver. We recommend a more sophisticated approach in free-breathing mode when irradiating the left lobe of liver in order to avoid stomach toxicity.

Clinical Usefulness of Implanted Fiducial Markers for Hypofractionated Radiotherapy of Prostate Cancer (전립선암의 소분할 방사선치료 시에 위치표지자 삽입의 유용성)

  • Choi, Young-Min;Ahn, Sung-Hwan;Lee, Hyung-Sik;Hur, Won-Joo;Yoon, Jin-Han;Kim, Tae-Hyo;Kim, Soo-Dong;Yun, Seong-Guk
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.91-98
    • /
    • 2011
  • Purpose: To assess the usefulness of implanted fiducial markers in the setup of hypofractionated radiotherapy for prostate cancer patients by comparing a fiducial marker matched setup with a pelvic bone match. Materials and Methods: Four prostate cancer patients treated with definitive hypofractionated radiotherapy between September 2009 and August 2010 were enrolled in this study. Three gold fiducial markers were implanted into the prostate and through the rectum under ultrasound guidance around a week before radiotherapy. Glycerin enemas were given prior to each radiotherapy planning CT and every radiotherapy session. Hypofractionated radiotherapy was planned for a total dose of 59.5 Gy in daily 3.5 Gy with using the Novalis system. Orthogonal kV X-rays were taken before radiotherapy. Treatment positions were adjusted according to the results from the fusion of the fiducial markers on digitally reconstructed radiographs of a radiotherapy plan with those on orthogonal kV X-rays. When the difference in the coordinates from the fiducial marker fusion was less than 1 mm, the patient position was approved for radiotherapy. A virtual bone matching was carried out at the fiducial marker matched position, and then a setup difference between the fiducial marker matching and bone matching was evaluated. Results: Three patients received a planned 17-fractionated radiotherapy and the rest underwent 16 fractionations. The setup error of the fiducial marker matching was $0.94{\pm}0.62$ mm (range, 0.09 to 3.01 mm; median, 0.81 mm), and the means of the lateral, craniocaudal, and anteroposterior errors were $0.39{\pm}0.34$ mm, $0.46{\pm}0.34$ mm, and $0.57{\pm}0.59$ mm, respectively. The setup error of the pelvic bony matching was $3.15{\pm}2.03$ mm (range, 0.25 to 8.23 mm; median, 2.95 mm), and the error of craniocaudal direction ($2.29{\pm}1.95$ mm) was significantly larger than those of anteroposterior ($1.73{\pm}1.31$ mm) and lateral directions ($0.45{\pm}0.37$ mm), respectively (p<0.05). Incidences of over 3 mm and 5 mm in setup difference among the fractionations were 1.5% and 0% in the fiducial marker matching, respectively, and 49.3% and 17.9% in the pelvic bone matching, respectively. Conclusion: The more precise setup of hypofractionated radiotherapy for prostate cancer patients is feasible with the implanted fiducial marker matching compared with the pelvic bony matching. Therefore, a less marginal expansion of planning target volume produces less radiation exposure to adjacent normal tissues, which could ultimately make hypofractionated radiotherapy safer.

A Study of the Radiotherapy Techniques for the Breast Including Internal Mammary Lymph Nodes (유방 보존술 후 내유림프절을 포함하는 방사선치료 기법에 관한 연구)

  • Jeong, Kyoung-Keun;Shim, Su-Jung;You, Sei-Hwan;Kim, Yong-Bae;Keum, Ki-Chang;Kim, Jong-Dae;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.35-41
    • /
    • 2009
  • Purpose: This study was designed to determine the optimum radiotherapy technique for internal mammary node (IMN) irradiation after breast-conserving surgery. Materials and Methods: We selected ten cases of early stage partial mastectomy for plan comparison. Five of the patients were treated to the right-side breast and the rest of the patients were treated to the left-side breast. For each case, four different treatment plans were made to irradiate the entire breast, IMNs and supraclavicular lymph nodes (SCLs). The four planning techniques include a standard tangential field (STF), wide tangential field (WTF), partially wide tangential field (PWT) and a photon-electron mixed field (PEM). We prescribed a dose of 50.4 Gy to the SCL field at a 3 cm depth and isocenter of the breast field. Results: The dose distribution showed clear characteristics depending on the technique used. All of the techniques covered the breast tissue well. IMN coverage was also good, except for the STF, which was not intended to cover IMNs. For the cases of the left-side breasts, the volume of the heart that received more than 30 Gy was larger (in order) for the WTF, PWT, PEM and STF. For radiation pneumonitis normal tissue complication probability (NTCP), the PWT showed the best results followed by the STF. Conclusion: Despite the variety of patient body shapes, the PWT technique showed the best results for coverage of IMNs and for reducing the lung and heart dose.

Comparison of Dosimetric Parameters of Patient with Large and Pendulous Breast Receiving Breast Radiotherapy in the Prone versus Supine Position (유방 크기가 큰 유방암 환자의 방사선 치료 시 환자의 자세에 따른 선량 비교)

  • Moon, Sun Young;Yoon, Myonggeun;Chung, Weon Kuu;Chung, Mijoo;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.234-240
    • /
    • 2015
  • The purpose of this study is to analyze dosimetric parameters of patient with large and pendulous breast receiving breast radiotherapy in the prone versus supine position. The patient underwent computed tomography simulation in both prone and supine position. The homogeneity index (HI), conformity index (CI), coverage index (CVI) to the left breast as planning target volume (PTV) and the doses to the lung, heart, and right breast as organ at risk (OAR) were compared by using dose-volume histogram. The lifetime attributable risk (LAR) according to the prone and supine position was measured for the lung and right breast. The HI, CI of the PTV decreased 21.7%, 6.49%, respectively and the CVI increased 10.8% with the prone position. The mean and maximum dose to the left lung decreased 91.6%, 87.0%, respectively and the volume parameters also decreased over 99% with the prone position. The parameters to the right lung were same regardless of the position. The mean and maximum dose to the heart decreased 51.6%, 14.2% with the prone position. But the mean and maximum dose to the right breast increased unlike the other OARs. The LARs to the lung decreased 80.3% (left), 24.2% (right) but the LAR to the right breast doubled with the prone position. The prone position is a favorable alternative for irradiation of breast in patients with large and pendulous breasts.