• Title/Summary/Keyword: 계측증폭기

Search Result 46, Processing Time 0.021 seconds

A Study on Measurement and Analysis of Pilot Channel Power at CDMA Communication Network (CDMA통신망에서 파일롯 채널전력 측정 및 분석에 관한 연구)

  • Jeong, Ki-Hyeok;Ra, Keuk-Hwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.6 s.360
    • /
    • pp.31-39
    • /
    • 2007
  • In this paper, a system for real-time or periodic measurement and analysis of RF parameters such as forward transmit power and pilot power in CDMA base station systems is proposed. Such RF characteristic parameter measurement can be prevented from system fault and used to achieve optimal service quality and maximum investment return through cell coverage expansion, subscriber capacity increase and so on. For forward power measurement, the local oscillator frequency for the detector is varied so that the transmit power for all channels can be measured. The channel power measurement can be used to analyze the variation in transmit power for changes in voice traffic. By comparing to forward $E_c/I_o$, the pilot channel power can be deducted, which can be used to determine uy degradation in transmit section modules such as the high dover amplifier. Since an accurate analysis of carefully measured data using the CDMA level detector must be made, the system is designed so that measurement errors due to changes in crest factor with modulation method can be overcome.

Gaze Tracking with Low-cost EOG Measuring Device (저가형 EOG 계측장치를 이용한 시선추적)

  • Jang, Seung-Tae;Lee, Jung-Hwan;Jang, Jae-Young;Chang, Won-Du
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.11
    • /
    • pp.53-60
    • /
    • 2018
  • This paper describes the experiments of gaze tracking utilizing a low-cost electrooculogram measuring device. The goal of the experiments is to verify whether the low-cost device can be used for a complicated human-computer interaction tool, such as the eye-writing. Two experiments are conducted for this goal: a simple gaze tracking of four directional eye-movements, and eye-writing-which is to draw letters or shapes in a virtual space. Eye-written alphabets were obtained by two PSL-iEOGs and an Arduino Uno; they were classified by dynamic positional warping after preprocessed by a wavelet function. The results show that the expected recognition accuracy of the four-directional recognition is close to 90% when noises are controlled, and the similar median accuracy (90.00%) was achieved for the eye-writing when the number of writing patterns are limited to five. In future works, additional algorithms for stabilizing the signal need to be developed.

The variation of poisson's ratio for The Cretaceous Sandstones and Shale in the Euiseoung Subbasin. (백악기 사암과 세일에 대한 포아송비의 변화)

  • 정태종
    • The Journal of Engineering Geology
    • /
    • v.6 no.2
    • /
    • pp.103-110
    • /
    • 1996
  • This study shows the variation of poisson's ratio according to stress for the Cretaceous sandstones and shale in the Euiseoung Subbasin. To make a mechanical experiment, samples prepared with 3.0 cm in diameter and 6.2 cm in length were used in testing stress and strain. Generally poisson's ratio has been considered as one of properties, but contrary to steel, the test result makes sure that poisson's ratio has functional relation to stress. I had used four methods to calculate poisson's ratio, Poisson's ratio shows considerable different results according to the calculating, method but it has similar tendency in an elastic limit. Poisson' s ratio increases rapidly and is distinguished clearly in internal fracture region according to the calculating method. Poisson's ratio of sandstone and shale is different from one another in low and high stress regimes,but it is linearly proportional to the stress in an elastic regimes, that is, ${\nu}_t={\;}{\nu}_0+P_{\sigma}({\nu}_0$:first stage Poisson's ratio, ${\nu}_t$:poisson's ratio, P: poisson's coefficient, $\sigma$:stress). Poisson's ratios of two kinds of rock samples show continuous variation from 0.1 to 0.21 in an elastic regime. The variation of poisson's ratio is much wider in an internal fracture regine. It varies from 0.22 to 0.45 in sandstone, which is out of elastic regime.

  • PDF

Implementation and Evaluation of Electroglottograph System (전기성문전도(EGG) 시스템의 개발 및 평가)

  • 김기련;김광년;왕수건;허승덕;이승훈;전계록;최병철;정동근
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.343-349
    • /
    • 2004
  • Electroglottograph(EGG) is a signal recorded from the vocal cord vibration by measuring electrical impedance across the vocal folds through the neck skin. The purpose of this study was to develop EGG system and to evaluate possibility for the application on speech analysis and laryngeal disease diagnosis. EGG system was composed of two pairs of ring electrodes, tuned amplifier, phase sensitive detector, low pass filter, and auto-gain controller. It was designed to extract electric impedance after detecting by amplitude modulation method with 2.7MHz carrier signal. Extracted signals were transmitted through line-in of PC sound card, sampled and quantized. Closed Quotient(CQ), Speed Quotient(SQ), Speed Index(SI), fundamental frequency of vocal cord vibration(F0), pitch variability of vocal fold vibration (Jitter), and peak-to-peak amplitude variability of vocal fold vibration(Shimmer) were analyzed as EGG parameters. Experimental results were as follows: the faster vocal fold vibration, the higher values in CQ parameter and the lower values in SQ and SI parameters. EGG and speech signals had the same fundamental frequency. CQ, SQ, and SI were significantly different between normal subjects and patients with laryngeal cancer. These results suggest that it is possible to implement portable EGG system to monitor the function of vocal cord and to test functional changes of the glottis.

Major B-H Loop Measurement of Toroidal Shape Magnetic Powder Core (토로이드형 분말코어의 Major B-H Loop 측정)

  • Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.3
    • /
    • pp.76-80
    • /
    • 2014
  • Toroidal cores made of metallic powder requires large magnetic field strength up to few decade kA/m to obtain major hysteresis loop. To overcome thermal heat generation problem from large exciting current during measurement, we have employed a real time hysteresis loop tracer which can digitize and calculate B-H signals in personal computer as real time. For example, when we magnetize specimen at 10 Hz frequency, we could display hysteresis loops 10 times per second. Using the real time hysteresis loop tracer, we could measure major hysteresis loop of toroidal shape metallic powder core at maximum flux density or maximum magnetic field strength to be measured within 5 second not to significant increasement of specimen temperature due to the heat dissipation from coil windings. For the constructed hysteresis loop tracer, we could measure hysteresis loop at magnetic field strength higher than 50 kA/m for the toroidal shape specimen.

Design of Cold-junction Compensation and Disconnection Detection Circuits of Various Thermocouples(TC) and Implementation of Multi-channel Interfaces using Them (다양한 열전쌍(TC)의 냉점보상과 단선감지 회로설계 및 이를 이용한 다채널 인터페이스 구현)

  • Hyeong-Woo Cha
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 2023
  • Cold-junction correction(CJC) and disconnection detection circuit design of various thermocouples(TC) and multi-channel TC interface circuit using them were designed. The CJC and disconnection detection circuit consists of a CJC semiconductor device, an instrumentation amplifier(IA), two resistors and a diode for disconnection detection. Based on the basic circuit, a multi-channel interface circuit was also implemented. The CJC was implemented using compensation semiconductor and IA, and disconnection detection was detected by using two resistor and a diode so that IA input voltage became -0.42V. As a result of the experiment using R-type TC, the error of the designed circuit was reduced from 0.14mV to 3㎶ after CJC in the temperature range of 0℃ to 1400℃. In addition, it was confirmed that the output voltage of IA was saturated from 88mV to -14.2V when TC was disconnected from normal. The output voltage of the designed circuit was 0V to 10V in the temperature range of 0℃ to 1400℃. The results of the 4-channel interface experiment using R-type TC were almost identical to the CJC and disconnection detection results for each channel. The implemented multi-channel interface has a feature that can be applied equally to E, J, K, T, R, and S-type TCs by changing the terminals of CJC semiconductor devices and adjusting the IA gain.