• Title/Summary/Keyword: 계측장치

Search Result 871, Processing Time 0.037 seconds

A Case Study on Impact Factor of Bridge in Tunnels Subjected to Moving Vehicle Load (터널내 교량의 이동차량하중 작용시 충격계수에 대한 사례연구)

  • 김재민;이중건;이익효;이두화
    • Tunnel and Underground Space
    • /
    • v.9 no.3
    • /
    • pp.185-193
    • /
    • 1999
  • This paper presents results of dynamic analysis for a bridge in intersection part of two tunnels subjected to moving vehicle load. Since such a bridge system is very unusual due to the fact that it is located in tunnel, the dynamic characteristics of the structure can not be assumed as conventional one. The structure investigated in this study it a reinforced concrete bridge in the intersection part of Namsan Tunnel-1 and Tunnel-2 in Seoul. It is supported by temporary steel structure which shall be constructed during the period of replacing lining in Tunnel-2. Dynamic analysis was carried out for the system using a finite element model constructed by general purpose FE program SAP2000. For this purpose, the structure, lining of tunnels, and surrounding rock were represented by finite elements, while the rock region it truncated and on its outer boundary viscous dampers were placed to simulate radiation of elastic waves generated tunnels. Several types of vehicle with various driving velocities were considered in this analysis. The FE model including vehicle loadings was verified by comparing calculated peak particle velocity with the measured one. From the analysis, the impart factor for the bridge was estimated as 0.21, which indicates that the use of upper bound for the impact factor in design code is reasonable for this kind of bridge system.

  • PDF

A Measurement of the Exposure Rates by Terrestrial y-rays in Taegu Area (대구지역(大邱地域) 지각(地殼) ${\gamma}$-선(線)의 조사선량율(照射線量率) 측정(測定))

  • Chang, Si-Ho;Jeong, Chun-Gyun;Kang, Hee-Dong;Lee, Mo-Sung;Choi, Mun-Kyu;Kim, Wi-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.2
    • /
    • pp.121-132
    • /
    • 1994
  • This study concerns about the measurement and the investigation of environmental radiation characteristics which the components and the distribution of exposure rates by terrestrial y-rays in Taegu area. $4^{'}{\phi}{\times}4^{'}$ NaI(T1) scintillation detector with a multichannel analyzer was used in the measurement of y-rays as a part of in-situ spectrometry at twenty eight different locations in this area. The conversion into the exposure rate from the measured ${\gamma}-ray$ spectrum has been carried out leading to a net exposure rate and component ones by $^{40}K,\;^{238}U$ series and $^{232}Th$ series products which are known by the major parts in the terrestrial ${\gamma}-rays$ generally. As a result, the average exposure rate by the terrestrial ${\gamma}-rays$ in Taegu area is $9.4{\mu}R/h$ and the distribution of individual exposure rates shows more or less differences between these locations even after the consideration of diurnal and yearly variations which are always involved in these measurements. The component parts of exposure rates are distributed $^{40}K\;2.9{\sim}4.6{\mu}R/h,\;^{238}U$ series $1.2{\sim}3,\;1{\mu}R/h,\;^{232}Th$ series $2.5{\sim}5.0{\mu}R/h$ over the measured locations.

  • PDF

An experimental study on the dynamic tooth movement of two molar uprighting springs by calorific machine (두 종류의 구치직립 스프링 사용시 저항원 및 근심경사치의 동적인 치아이동 양상에 관한 연구)

  • Chun, Youn-Sic;Row, Joon
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.273-285
    • /
    • 2000
  • The aim of this investigation was to evaluate the differences of two canti-leyer springs by using a new simulation system. This was done using a Calorific machine that compared iron uprighting spring and root uprighting spring. The Calorific machine was designed to allow observation of the whole process of tooth moving, and is composed of three parts(a temperature regulating system, electro-thermodynamic teeth, and an artificial alveolar bone component). The experiment of both mechanics were repeated five times and measured two times. The intra-examiner agreement and inlet-examiner agreement were $96.54\%\;and\;95.73\%$ and these data were statistically tested by paired t-test. The obtained results were as follows. 1. Distal and buccal movement of the anchor teeth were observed greater in the root uprighting spring than the crown uprighting spring. 2. Crown uprighting spring showed distal movement of the crown of lower second molar for 3.29mm but root uprighting spring showed only 1.68mm. 3. Crown uprighting spring exhibited forward movement of mesial and distal root of the lower second molar for 3.91mm, 3.60mm but the root uprighting spring showed 6.76mm, 6.26mm.

  • PDF

Establishment of the Monoenergetic Fluorescent X-ray Radiation Fields (교정용 단일에너지 형광 X-선장의 제작)

  • Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Jae-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.33-47
    • /
    • 1998
  • Using a combination of an X-ray generator Installed in radiation calibration laboratory of Korea Atomic Energy Research Institute (KAERI) and a series of 8 radiators and filters described in ISO-4037, monoenergetic fluorescent X-rays from 8.6 keV to 75 keV were produced. This fluorescent X-rays generated by primary X-rays from radiator were discriminated $K_{\beta}$ lines with the aid of filter material and the only $K_{\alpha}$ X-rays were analyzed with the high purity Ge detector and portable MCA. The air kerma rates were measured with the 35 co ionization chamber and compared with the calculational results, and the beam uniformity and the scattered effects of radiation fields were also measured. The beam purities were more than 90 % for the energy range of 8.6 keV to 75 keV and the air kerma rates were from 1.91 mGy/h (radiator : Au, filter : W) to 54.2 mGy (radiator : Mo, filter : Zr) at 43 cm from center of the radiator. The effective area of beam at the measurement point of air kerma rates was 12 cm ${\times}$ 12 cm and the influence of scattered radiation was less than 3 %. The fluorescent X-rays established in this study could be used for the determination of energy response of the radiation measurement devices and the personal dosemeters in low photon energy regions.

  • PDF

A Study on the accuracy of speed measuring system by the Doppler effect -The error of speed single beam Doppler log over the ground by various trim- (Doppler 효과(效果)에 의한 속도계측장치(速力計測裝置)의 정도(精度)에 관(關)한 연구(硏究) -Single beam Doppler log의 트림 변화에 따른 대지속력(對地速力) 오차(誤差)-)

  • Kim, Koang-Hong
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.9 no.2
    • /
    • pp.179-187
    • /
    • 1997
  • Doppler log and current meter are based on the measurment of the doppler effect. Ship's speed over the ground measured by means of doppler log effect of underwater ultrasonic intends to get infulence by the difference of sound velocity, the ship's course, the sea bottom inclination, the trim and tranducer installation etc. This paper investigated on the error of speed over the ground by change of the trim comparing the real speed obtained by the mile post with the speed of single beam type doppler log on the trainning ship Kyeongyangho. The results are as follows ; 1. Indicating speed of doppler log is very much greatly influenced on variation of trim, but the real speed is less affected variation by trim. 2. The range of variation and error of speed over ground are smallest when ship's trim is 2.15m trim by the stern.

  • PDF

A Comparative Study of Facemask Therapy with Two Types of Bonded Expander (Bonded expander 형태에 따른 facemask의 치료 효과 비교연구)

  • Lee, Eunha;Park, Kitae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.4
    • /
    • pp.298-305
    • /
    • 2014
  • The purpose of this study is to evaluate the effects of facemask therapy in patients with Class III malocclusion with two types of bonded expanders covering different numbers of anchored teeth and to compare the anchorage value of two types of bonded expander. Eighteen subjects with Class III malocclusion in early mixed dentition were included in this study, and subjects were divided into two groups based on the number of teeth covered by bonded expander: group 1 (splinting four teeth on each side, 9 subjects) and group 2 (splinting three teeth on each side, 9 subjects). Lateral cephalograms were obtained and assessed before (T1) and after (T2) the treatment. The facemask therapy showed skeletal effects including anterior movement of maxilla and backward rotation of mandible in both groups, with no significant differences between groups. Mesial movement of maxillary molars which indicates anchorage loss of the bonded expander was found in both groups, but significantly larger mesial movement was found in group 2 than in group 1. In conclusion, the value of anchorage was different according to the number of teeth covered by bonded expander as an intraoral anchorage of facemask, but there were no significant differences in skeletal effects.

Estimation of Suspended Sediment Concentration in Small Stream with Acoustic Backscatter from Horizontal ADCP based on Real-Scale Field Experiment (실규모 현장 실험 기반 H-ADCP 초음파 산란도 활용 소하천용 하천 부유사 농도 측정 기법 개발)

  • Seo, Kanghyeon;Kim, Dongsu;Son, Geunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.1023-1035
    • /
    • 2016
  • Suspended sediment concentration (SSC) is a crucial riverine parameter in terms that it can be utilized for analyzing sediment transport, stability assessment of river and structure and so on. However, in case of domestic, sediment discharge data are not enough because of using conventional sediment samplers. This study aimed at developing a practical technique for estimating suspended sediment concentration in high spatial and temporal resolution by building relationship between acoustic backscatter (or SNR) from H-ADCP with actually observed data using LISST-100X. In this regard, a dedicated correction algorithm was proposed particularly for the adapted H-ADCP (SonTek SL-3000). Then, a SNR-SSC relation was built based upon a real-scale field experiment, where both H-ADCP and LISST-100X were concurrently operated to observe SNR and SSC, respectively. The coefficient of determination for the developed regression equation of SNR-SSC relation was around 0.85~0.88, thereby the relation could be evaluated to be highly correlated. The result of this study might be potentially applied for real-time and simultaneous observation of SSC when H-ADCP could be applied.

Accuracy Verification of Optical Tracking System for the Maxillary Displacement Estimation by Using of Triangulation (삼각측량기법을 이용한 광학추적장치의 상악골 변위 계측에 대한 정확성 검증)

  • Kyung, Kyu-Young;Kim, Soung-Min;Lee, Jong-Ho;Myoung, Hoon;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.41-52
    • /
    • 2012
  • Purpose: Triangulation is the process of determining the location of a point by measuring angles to it from known points at either end of a fixed baseline. This point can be fixed as the third point of a triangle with one known side and two known angles. The aim of this study was to find a clinically adaptable method for applying an optical tracking navigation system to orthognathic surgery and to estimate its accuracy of measuring the bone displacement by use of triangulation methods. Methods: In orthognathic surgery, the head position is not fixed as in neurosurgery, so that a head tracker is needed to establish the reference point on the head surface byusing an optical tracking system. However, the operation field is interfered by its bulkiness that makes its clinical use difficult. To solve this problem, we designed a method using an Aquaplast splinting material and a mini-screw in applying a head tracker on a patient's forehead. After that, we estimated the accuracy of measuring displacements of the ball marker by an optical tracking system with a conventional head tracker (Group A) and with a newly designed head tracker (Group B). Measured values of ball markers' displacements by each optical tracking system were compared with values obtained from fusion CT images for an estimation of accuracy. Results: The accuracy of the optical tracking system with a conventional head tracker (Group A) is not suitable for clinical usage. Measured and predictable errors are larger than 10 mm. The optical tracking system with a newly designed head tracker (Group B) shows 1.59 mm, 6.34 mm, and 9.52 mm errorsin threeclinical cases. Conclusion: Most errors were brought on mainly from a lack of reproducibility of the head tracker position. The accuracy of the optical tracking system with a newly designed head tracker can be a useful method in further orthognathic navigation surgery even though the average error is higher than 2.0 mm.

PHYSIOLOGIC DRIFT OF THE MANDIBULAR DENTITION FOLLOWING THE EXTRACTION OF FOUR FIRST PREMOLARS (상, 하악 제1소구치 발치 후 하악치열의 생리적 치아이동에 관한 연구)

  • Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.26 no.1 s.54
    • /
    • pp.33-41
    • /
    • 1996
  • Retrostpective study of two groups of patients was conducted to evaluate the physiologic drift of the mandibular teeth following the extraction of four first premolars. The concept of physiologic drift, commonly referred to as 'driftodontics', following first premolar extractions has been gaining acceptance in the orthodontic community, the exact nature and amount of drift has not been adequately documented. There were also no guide lines as to when drift should be allowed to now. The purpose of this study was to quantify physiologic drift of the untreated mandibular dentition following extraction of the four first premolars during the early permanent and late permanent dentition stages. The early permanent dentition extraction sample(Group 1) included 26 Patients and the mean age at pretreatment was approximately 13.5 years. The observation period following extraction was approximately 6.96 months. The late permanent dentition extraction sample(Group 2) included 31 patients. The mean age at pretreatment was 21.3 years, followed by a observation period of 7.26 months. During the observation period, except for the extractions, no other mandibular therapy was rendered. Pre-and post-treatment lateral cephalograms and dental casts were analyzed. The obtained results were as follows 1. Group 2 showed marked changes in movements of the mandibular incisors and canines but minimal changes in molars. 2. The amount of changes in movements of the mandibular incisors and canines were significantly greater in Group 1 than in Group 2. The results showed no differences in rates of molar movements between groups. 3. Physiologic drift of the dentition produced desirable changes such as decreased Incisor Irregularity.

  • PDF

A Development of Automation system and a way to use Solar Energy System Efficiently in Greenhouse(2) - Study on improvement of growth and yield of a cucumber in soil heating - (시설원예 태양열 시스템의 효율적 이용과 자동화 장치개발(2) -지중가온에 의한 오이 생육 및 수량성 향상에 관한 연구-)

  • 김진현;오중열;구건효;김태욱
    • Journal of Bio-Environment Control
    • /
    • v.7 no.1
    • /
    • pp.25-33
    • /
    • 1998
  • Root zone temperature have influenced on protected cultivation in winter season. Especially root zone temperature is acted on limiting factor in crop cultivation. This study was conducted to obtain optimum temperature of root zone in Protected cultivation Root zone was warmed by heated water($28^{\circ}C$) flowing through the PPC pipe(${\phi}15$) buried depth 40 cm. And the flowing water was heated by solar system. Minimum air temperature during night time was set at $14^{\circ}C$ and maximum air temperature during day time was set at $28~30^{\circ}C$ the growing period of cucumber was from Nov. 6, 1996 to Jan. 30, 1997. The results are summarized as follows. 1. Average soil temperature at 15~20 cm depth was $22^{\circ}C$ at warming plots, $17~18^{\circ}C$ at non-warming plots 2. Early growth in leaf length, stem diameter, number of leaves and leaf area for 30 days after planting were accelerated by root zone warming. Especially, the grawing rate of soil warming plots was higher 27% in leaf length, 51% in leaf number, 150% in leaf area than non-warming Plots. Above-ground and underground part of warming plots was higher 117%, 56% than non-warming plots. 3. In total yield analysis, number of fruits were 614 in soil warming and 313 in non-warming plots. In the result, total yield of soil warming plots was increased with 196% than non-warming plots. 3. In total yield analysis. number of fruits were 614 in soil warming and 313 in non-warming plots. In the result. total yield of soil warming plots was increased with 196% than non-warming plots.

  • PDF