Minimizing the Measurement Error from Gas Compositions of Gas Vent in Sanitary Landfill (쓰레기 매립지 가스 포집관에서 가스조성에 따른 계측오차의 최소화)

  • 이해승;이문형
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.28-35
    • /
    • 2002
  • A methods of minimizing the measurement error brought from gas compositions was proposed by Hot wire Anemometer which don't have measurement resistance to calculate of gas vent in sanitary landfill. It was determined measurement error to compared velocity at the center of pipe to calculate using rotor meter and density gas compositions with velocity at the center of pipe to calculate using water head indicator which don't have measurement resistance. Considering the methods of minimizing gas velocity in sanitary landfill using hot wire anemometer and rotor meter, it was found to minimize within 10% as error of gas vent in sanitary landfill.

The comparison of landmark identification errors and reproducibility between conventional lateral cephalometric radiography and digital lateral cephalometric radiography (일반두부방사선계측사진과 디지털방사선계측사진의 계측점 식별의 오차 및 재현성에 관한 비교 연구)

  • Lee, Yang-Ku;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.79-89
    • /
    • 2002
  • The purpose of this study is to evaluate the reproducibility and errors in landmark identification of conventional lateral cephalometric radiography and digital lateral cephalometric radiography. Fifteen conventional lateral cephalometric radiographs and fifteen digital lateral cephalometric radiographs were selected in adults with no considerations on sex and craniofacial forms. Each landmark was identified and expressed as the coordinate (x, y). The landmarks were classified into 3 groups. The landmarks of the first identification was T1, identification after one week was T2, and identification after one month was T3. The mean and standard deviation of identification errors between replicates were calculated according to the x and y coordinates. The errors between first identification and second identification were expressed as T2-T1(x), T2-T1(y) and those between first identification and third identification were expressed as T3-T1(x), T2-T1(y). Each was divided into conventional lateral cephalometric radiography and digital lateral cephalometric radiography. The independent t- test was used for statistical analysis of identification errors for the evaluation of reproducibility. The results of this study were as follows ; 1. Generally, the mean and standard deviation of landmark identification errors in digital lateral cephalometric radiography was smaller than those of conventional lateral cephalometric radiography. 2. Only a few landmarks showed statistically significant difference in identification error between conventional lateral cephalometric radiography and digital lateral cephalometric radiography. 3. The enhancement of image quality didn't guarantee decrease in landmark identification error and didn't affect tendency of landmark identification error.

A 3D Image Measurement Algorithm for the Distance Measurement to the Object on 3D Plane (평면상에 존재하는 물체의 거리계측을 위한 3차원 영상계측 알고리즘)

  • 김용준;서경호;김태효
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.12a
    • /
    • pp.65-68
    • /
    • 2000
  • 본 논문에서는 평면상에 존재하는 물체까지의 거리를 카메라시스템을 이용하여 실제 거리를 계측하는 알고기즘을 제안하였다. 계측 시스템을 교정하기 위해, 우선 3차인 실세계 좌표계와 2차원의 카메라 좌표계의 관계를 해석하고, 카메라의 변수들을 포함하는 카메라 좌표계의 변수들을 구하였다. 한편, 3파원 공간에서 계측면을 평면으로 가정하고 평면의 방정식과 좌표계 변환 방정식으로부터 뉴턴-랩슨법을 이용하여 최소값에 대응하는 근사치를 구함으로써 물체까지의 거리 정보를 추출하였다. 실제의 계측 실험에서, 도로에 표준 물체인 Ca]ibration 시트를 두고 승용차의 백미러 위치에 카메라를 설치하고 영상을 획득하였다. 계측 거리는 4m부터 lOm까지는 1m간격으로 계측하고, 10m부터 30m까지는 10m간격으로 계측하였다. 그 결과 4m에서는 약 1.4mm의 오차가 발생하였고, 30m의 거리에서는 3.5m의 오차를 보였는데 계측 거리가 길어질수록 오차가 지수함수적으로 증가함을 알 수 있었다.

  • PDF

Error Quantification of Photogrammetric 6DOF Pose Estimation (사진계측기반 6자유도 포즈 예측의 오차 정량화)

  • Kim, Sang-Jin;You, Heung-Cheol;Reu, Taekyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.5
    • /
    • pp.350-356
    • /
    • 2013
  • Photogrammetry has been widely used for measuring the important physical quantities in aerospace areas because it is a remote and non-contact measurement method. In this study, we analyzed photogrammetric error which can be occur in six degrees of freedom(6DOF) analysis among coordinates systems with single camera. Error analysis program were developed, and validated using geometric problem converted from imaging process. We analogized that the statistic from estimated camera pose which is need to 6DOF analysis is normally distributed, and quantified the photogrammetric error using estimated population standard deviation.

A STUDY ON THE ERRORS UN THE CEPHALOMETRIC MEASUREMENTS (두부방사선사진의 계측오류에 관한 연구)

  • Na, Kwang-Cheon;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.75-83
    • /
    • 1998
  • This study was done to recognize the importance of errors in measurements of cephalometric radiograph and to find the anatomical structures those need special care to select as a reference points through the detection of the systematic errors and estimation of random errors. For this purose, 100 cephalometric radiographs were prepared by usual manner and 61 reference points, and 130 measurement variables were established. Measurement errors were detected and estimated by the comparison of the 25 randomly-selected samples for repeated measurements with the main sample. The following results were obtained : 1. In comparison of the repeated measurements, there were statistical significant differences in 24 variables which were 18.4% of 130 total variables. 2. The frequency of the difference in identification of the reference points between the repeated measurements was very high in the root apex of upper incisor(as), the most posterior wall of maxilla(tu), soft tissue nasion(n'), soft tissue frontal eminence(ft), and ad3 in airway. 3. After correction of reference points marking until the level of below 5% significance, the range of random errors were from 0.67 to 1.71 degree or mm. 4. The variable shown the largest random error was the interincisal angle(ILs-ILi). 5. Measurement errors were mainly caused by the lack of precision in anatomic definitions and obscure radiographic image. From the above results, the author could find the high possibility of errors in cephalometric measurements and from this point, we should include error analysis in all the studies concerning measurments. In is essential to have a concept of error analysis not only for the investigator but also for a reader of other articles.

  • PDF

A Measurement Method for 3D Human Body Using 2D Images (2D 영상을 이용한 3D 인체 계측 방법)

  • 김창우;최창석;김효숙;강인애
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.201-204
    • /
    • 2001
  • 디지털 카메라를 이용하여 인체의 영상을 촬영하여 3D 인체를 계측하는 영상 계측 방법을 제안한다. 영상 계측을 위해 인체 촬영 환경을 설정하고, 정면, 측면, 후면의 인체 2D 영상을 촬영하여 사영투영을 고려하여 3D 인체를 추정하는 알고리즘을 개발한다. 인체 계측의 항목 중 40항목에 대해 직접 계측, 영상 계측, 3D 계측을 3인이 교대로 시행한 결과를 비교하고 있다. 계측자별, 계측 방법별로 비교할 때, 영상 계측은 최대오차 0.44cm로 3D 계측(허용오차 0.5cm)와 유사하여, 직접 계측에 비해 우수한 성능을 나타내고 있다. 이것은 영상 계측에서 사영투영을 이용하여 인체의 3D위치를 추정하여 계측 결과를 보정하고 있기 때문이다. 또한, 계측치 이외에 계측 장비, 비용, 기동성, 인력 부담등 여러 가지면 에서도 영상 계측은 장점을 고루 갖춘 방법으로 인체 계측에 사용할 수 있는 새로운 방법으로 기대된다.

  • PDF

간섭계에 있어서의 계통 오차의 자율 교정 알고리즘

  • 후지모토이쿠마츠;이태용;편영식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.139-139
    • /
    • 2004
  • 나노테크놀로지의 발전과 함께, 간섭계를 이용한 정밀 계측의 중요성이 더욱 더 높아지고 있다. 본 방법은, 간섭성을 가진 레이저의 파장을 계측의 척도로서 기준 평면으로 사용되는 참조면에 대한 상대 측정에 의해, 3차원 형상을 계측하는 것이다. 고로, 본 논문에서는 간섭계를 이용한 계측에서 고정밀도를 실현하기 위해서는 참조면의 교정이 중요하다는 기본적인 생각을 기초로, 참조면 오차(참조면의 이상적 평면으로부터의 차이)를 주로, 광학 부품에 의한 파면의 왜곡 등을 포함한 간섭계 시스템의 계통 오차를 결정하는 방법을 검토한다.(중략)

  • PDF

Error Correction Technique for Industrial Distance measurement (산업용 거리 계측기를 위한 오차 보정 기법)

  • Kim, Eun-Ju;Bae, Young-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1412-1413
    • /
    • 2008
  • 본 연구에서는 산업용 거리 계측기에서 정밀한 측정에 요구되는 오차 보정 기법을 제시하였다. 제시한 기법은 본 연구에서는 산업용 거리 계측기에서 보다 정밀한 측정을 위한 방법으로 측정하고자 하는 기법을 전원회로에서의 잡음, 공급 전원의 잡음, 공통모드에서의 잡음, 중간주파수에 섞여 있는 잡음 및 비교기에서의 오차 저감 기법을 제시하고자 한다.

  • PDF

냉동저장고 주변의 온도분포에 관한 현장 계측 및 수치해석

  • Lee, Gyu-Sang;Lee, Jeong-In
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2004.04a
    • /
    • pp.101-110
    • /
    • 2004
  • 지하냉동 저장고 주변의 온도분포를 예측하기 위하여 국내 최초로 건설된 상업적 규모의 지하암반 저장고인 '곤지암 지하암반 저장고'에 대한 약 5년간의 암반 온도 계측 결과와 FLAC을 이용한 2차원 및 3차원 수치해석 결과를 비교하였다. 수치해석 수행 시 지하수, 지하수의 동결잠열, 지표온도의 영향을 고려하였으며, 각각의 요소가 지하암반 온도분포에 미치는 영향을 계측자료와의 비교를 통하여 분석하였다. 각각의 경우에 대한 2차원 수치해석과 계측결과를 비교한 결과 지하수와 동결잠열을 같이 고려한 경우가 지하수의 영향만 고려한 경우에 비해 오차가 적게 나타났으며, 2차원 해석에서는 냉동기 가동 시간이 경과하면서 지표면의 영향으로 오차가 커지는 경향이 나타났다. 3차원 수치해석은 지표까지 거리의 영향을 고려하여 수행하였으며, 해석결과 2차원과 같이 지하수 및 동결잠열의 영향이 고려된 해석이 가장 작은 오차를 나타내었으며, 시간의 경과에 따른 오차의 증가는 없었다.

  • PDF

A Study on Applicability Evaluation of digital Photogrammetry for Settlement Measurement of Soil Contaminated with Heavy Metals (중금속으로 오염된 지반의 침하계측을 위한 수치사진측량의 적용성 평가)

  • Han, Jung-Geun;Park, Jeong-Jun;You, Seung-Kyong;Yun, Jung-Mann;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.4
    • /
    • pp.85-93
    • /
    • 2020
  • This study describes the results of laboratory model test on settlement of soil contaminated with heavy metals, in order to evaluate the applicability of VMS to the measurement of gound settlements generated during the purification of contaminated soil. The measurement results for settlement of contaminated soil were compared using a 3D-Visual Monitoring System (VMS) based on digital photogrammetry and a total station. The test result showed that the settlement of the soil contaminated with heavy metals occurred a lot in the experimental condition in which the hydrophilic filter was applied. The minimum and maximum error ranges of VMS were calculated as ±0.36mm and ±0.87mm, respectively, and the error of VMS was satisfied in all experimental conditions. The average error rate of VMS was lower in the hydrophilic filter condition than in the hydrophobic filter condition. Therefore, it was evaluated that VMS can be applied to measure the settlement of contaminated soil.