• 제목/요약/키워드: 계측거리

Search Result 447, Processing Time 0.024 seconds

Effect of presurgical nasoalveolar molding (PNAM) appliance and cheiloplasty on alveolar molding of complete unilateral cleft lip and palate patients (완전 편측성 순구개열 신생아 환자의 술전 비치조 정형장치와 구순열 수술이 치조골 정형에 미치는 효과)

  • Kim, Na-Young;Lee, Shin-Jae;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.235-245
    • /
    • 2003
  • The goal of the present study was to evaluate the effects of PNAM appliance and cheiloplasty on alveolar molding. Samples consisted of 16 unilateral cleft lip and palate infants (10 males and 6 female, mean age=37.0 days after birth, average alveolar cleft gap=10.46m), who were treated with PNAM appliances by one orthodontist and rotation- advancement cheiloplasty by one surgeon in Seoul National University Hospital. Average duration of alveolar molding treatment was 13.10 weeks and these patients were recalled at average 8.31 weeks after cheiloplasty. These patients' models were obtained at initial visit (T0, mean age : $37.0\pm27.89$ days after birth), after successful alveolar molding (T1, mean age : $119.25\pm40.18$ days after birth), and after cheilopasty (T2, mean age : $190.81\pm42.78$ days after birth). Seven linear and five angular variables were measured using 1 : 1 photometry and soft ware program(V-ceph. Cybermed. Seoul, Korea). Paired t-test was performed to investigate statistical significance at p<0.05 level. 1 The posterior parts of alveolar segments were the stable structures during alveolar molding treatment period and after cheiloplasty in infants. 2. The closure of cleft gap during alveolar molding was usually due to backward bending of the whole part of the greater segment. 3. Although forward growth of the greater segment was hindered by alveolar molding, it resumed after cheiloplasty. 4. Increase of anterior inter-segment angle after cheiloplasty was due to the molding effect of the lip scar pressure.

Correlation between menton deviation and dental compensation in facial asymmetry using cone-beam CT (Cone-beam CT를 이용한 안면비대칭자에서 이부편위에 따른 치성보상의 양상분석)

  • Park, Soo-Byung;Park, Jeong-Heuy;Jung, Yun-Hoa;Jo, Bong-Hye;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.39 no.5
    • /
    • pp.300-309
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the correlation between menton deviation and dental compensation in facial asymmetry. Methods: Tooth axis and distance of first molar and canine to the reference plane were investigated by cone-beam computerized tomography. The subjects consisted of 50 patients with asymmetric mandibles (male 21, female 29, mean age 24.3 years). Control groups were also assessed (male 11, female 9, mean age 25.6 years). Nine measurements (5 linear measurements and 4 angular measurements) were measured in order to evaluate the correlation between menton deviation and the linear and angular difference of first molar and canine in the deviated and none-deviated sides using the defined MPR images. The differences between deviated and non-deviated side, according to menton deviation, were statistically analyzed using stepwise multiple regression analysis. Results: From the result, Menton deviation was negatively correlated with mandibular first molar's angular measurement (${\Delta\angle}LM6$-Mn plane (dev.-ndev.)) and positively with maxillary fist molar's angular measurement (${\Delta\angle}UM6$-FH plane (dev.-ndev.)) (p < 0.01). Two angular measurements (${\Delta\angle}LM6$-Mn plane (dev.-ndev.), ${\Delta\angle}UM6$-FH plane (dev.-ndev.)) explained the variability in menton deviation with a significant $r^2$ value of 0.589. Conclusions: This study suggests that the tooth axis of upper and lower first molars leans towards the deviated side of Menton when there is mandibular asymmetry with Menton deviation.

An Improved CBRP using Secondary Header in Ad-Hoc network (Ad-Hoc 네트워크에서 보조헤더를 이용한 개선된 클러스터 기반의 라우팅 프로토콜)

  • Hur, Tai-Sung
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.1
    • /
    • pp.31-38
    • /
    • 2008
  • Ad-Hoc network is a network architecture which has no backbone network and is deployed temporarily and rapidly in emergency or war without fixed mobile infrastructures. All communications between network entities are carried in ad-hoc networks over the wireless medium. Due to the radio communications being extremely vulnerable to propagation impairments, connectivity between network nodes is not guaranteed. Therefore, many new algorithms have been studied recently. This study proposes the secondary header approach to the cluster based routing protocol (CBRP). The primary header becomes abnormal status so that the primary header can not participate in the communications between network entities, the secondary header immediately replaces the primary header without selecting process of the new primary header. This improves the routing interruption problem that occurs when a header is moving out from a cluster or in the abnormal status. The performances of proposed algorithm ACBRP(Advanced Cluster Based Routing Protocol) are compared with CBRP. The cost of the primary header reelection of ACBRP is simulated. And results are presented in order to show the effectiveness of the algorithm.

  • PDF

Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring (파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측)

  • Kim, Young-Su;Park, Jin Hyung;Cho, Hwa Youn;Kim, Jae Hyeon;Kwon, Heungrok;Seo, Hee;Park, Se-Hwan;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Compton cameras overcome several limitations of conventional mechanical collimation based gamma imaging devices, such as pin-hole imaging devices, due to its electronic collimation based on coincidence logic. Especially large-scale Compton camera has wide field of view and high imaging sensitivity. Those merits suggest that a large-scale Compton camera might be applicable to monitoring nuclear materials in large facilities without necessity of portability. To that end, our research group have made an effort to design a large-scale Compton camera for safeguard application. Energy resolution or position resolution of large-area detectors vary with configuration style of the detectors. Those performances directly affect the image quality of the large-scale Compton camera. In the present study, a series of Geant4 Monte Carlo simulations were performed in order to examine the effect of those detector parameters. Performance of the designed large-scale Compton camera was also estimated for various monitoring condition with realistic modeling. The conclusion of the present study indicates that the energy resolution of the component detector is the limiting factor of imaging resolution rather than the position resolution. Also, the designed large-scale Compton camera provides the 16.3 cm image resolution in full width at half maximum (angular resolution: $9.26^{\circ}$) for the depleted uranium source considered in this study located at the 1 m from the system when the component detectors have 10% energy resolution and 7 mm position resolution.

The effects of pregnancy on alveolar bone turnover during experimental tooth movement in rats (백서에서 실험적 치아이동시 임신이 치조골 교체(Turnover)에 미치는 영향에 대한 연구)

  • Kim, Young-Sun;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.30 no.4 s.81
    • /
    • pp.413-421
    • /
    • 2000
  • The purpose of this study was to observe the effects of pregnancy on the experimental tooth movement and alveolar bone turnover process of Sprague-Dawley female rat. Sixty rats were divided into pregnant-tooth movement group(P-Tm), normal-tooth movement group(N-Tm) and normal group(N). Maxillary first molar appliances were inserted bilaterally and activated to 40grams. To measure the amount of tooth movement, x-ray was taken 2 times after appliance insertion and before sacrifice. Animals were sacrificed at 1,3,7,14 days(N=5). Just after sacrifice, alveolar bones were collected and frozen immediately for biochemical analysis. Tooth movement was assessed cephalometrically and tartrate-resistant acid(TRAP) and alkaline phosphatase (ALP) activities were measured in extracts of paradental alveolar bone. The results were as follows: 1. The amount of tooth movement in P-Tm group was greater than that of N-Tm group(p<0.01). 2. Alveolar bone ALP of normal tooth movement group was not significantly different from the control, TRAP was significantly different from the control(p<0.01). In normal tooth movement group, alveolar bone ALP was increased gradually and peak(day 7) fell off significantly at day 14(p<0.05). The Peak of alveolar bone TRAP(day 7) fell off slightly, sustained day 14(p<0.01). 3. Alveolar bone ALP and TRAP of pregnant tooth movement group were not significantly different from that of normal tooth movement group. In pregnant tooth movement group, alveolar bone ALP was increased at day 3(p<0.01) and fell off significantly at day 7-14, alveolar bone TRAP were increased at day 3 and sustained day 14. 4. The peak of alveolar bone phosphatases in pregnant tooth movement group(day3) preceded the peak in normal tooth movement group(day7) (p<0.01). According to the above results, we suggested that bone resorption activity was increased in alveolar bone of pregnant rat, and the degree of tooth movement in pregnancy may be greater than that of normal group because of high bone turnover of alveolar bone in pregnant rat.

  • PDF

A Clinical Study on Fiberoptic Bronchoscopy (화이버 기관지경 검사의 임상적 고찰)

  • 이상기;홍영호;권평중;김중환
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.3.2-3
    • /
    • 1981
  • This paper was attemped to analize 55 cases of fiberoptic bronchoscopy during period of 3 years from Feb. 1978 till Feb. 1981 in Chung Ang University hospital. The results were as follow; 1) In age distribution; Most common age group was 5th decade (15 cases, 27.2%) and the other age groups showed relatively even distribution. 2) The ratio of male to female was 3 to 1. 3) The chief complaints were presented in following order; cough (52%), hemoptysis(25%), dyspnea(23.6%), chest pain(18%), chest disomfort(9%). 4) Direct smear of bronchoscopic aspiration material; Not found 33 cases (60%) were most common finding. In the founded bacteria Gram positive cocci 2 cases (3.6%), Gram negative cocci 2 cases (3.6%), Gram positive bacilli 1 cases (1.8%), Gram negativebacilli 2 cases (3.6%), mixed form 15 cases(27.2%) were presented. 5) Bacterial culture of bronchoscopic aspiration material; No growth 28 cases (50.9%) were most common finding. In the bacterial growth, alpha hemolytic streptococci 10 cases (18.2%), Neisseria group 7cases(12.7%), Klebsiella 2 cases (3.6%), Pseudomonas 2 cases (3.6%), mixed culture 6 cases (10.9%) were presented, 6) The diagnosis of bronchoscopic appearance, laboratory exam., and pathologic exam. of biopsed specimen were 21 cases (38.1%) primary carcinoma of bronchus, 8 cases (14.5%) pulmonary tuberculosis, 7 cases (12.7%) bronchitis in orders.

  • PDF

Evaluation and Verification of the Attenuation Rate of Lead Sheets by Tube Voltage for Reference to Radiation Shielding Facilities (방사선 방어시설 구축 시 활용 가능한 관전압별 납 시트 차폐율 성능평가 및 실측 검증)

  • Ki-Yoon Lee;Kyung-Hwan Jung;Dong-Hee Han;Jang-Oh Kim;Man-Seok Han;Jong-Won Gil;Cheol-Ha Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.489-495
    • /
    • 2023
  • Radiation shielding facilities are constructed in locations where diagnostic radiation generators are installed, with the aim of preventing exposure for patients and radiation workers. The purpose of this study is seek to compare and validate the trend of attenuation thickness of lead, the primary material in these radiation shielding facilities, at different maximum tube voltages by Monte Carlo simulations and measurement. We employed the Monte Carlo N-Particle 6 simulation code. Within this simulation, we set a lead shielding arrangement, where the distance between the source and the lead sheet was set at 100 cm and the field of view was set at 10 × 10 cm2. Additionally, we varied the tube voltages to encompass 80, 100, 120, and 140 kVp. We calculated energy spectra for each respective tube voltage and applied them in the simulations. Lead thicknesses corresponding to attenuation rates of 50, 70, 90, and 95% were determined for tube voltages of 80, 100, 120, and 140 kVp. For 80 kVp, the calculated thicknesses for these attenuation rates were 0.03, 0.08, 0.21, and 0.33 mm, respectively. For 100 kVp, the values were 0.05, 0.12, 0.30, and 0.50 mm. Similarly, for 120 kVp, they were 0.06, 0.14, 0.38, and 0.56 mm. Lastly, at 140 kVp, the corresponding thicknesses were 0.08, 0.16, 0.42, and 0.61 mm. Measurements were conducted to validate the calculated lead thicknesses. The radiation generator employed was the GE Healthcare Discovery XR 656, and the dosimeter used was the IBA MagicMax. The experimental results showed that at 80 kVp, the attenuation rates for different thicknesses were 43.56, 70.33, 89.85, and 93.05%, respectively. Similarly, at 100 kVp, the rates were 52.49, 72.26, 86.31, and 92.17%. For 120 kVp, the attenuation rates were 48.26, 71.18, 87.30, and 91.56%. Lastly, at 140 kVp, they were measured 50.45, 68.75, 89.95, and 91.65%. Upon comparing the simulation and experimental results, it was confirmed that the differences between the two values were within an average of approximately 3%. These research findings serve to validate the reliability of Monte Carlo simulations and could be employed as fundamental data for future radiation shielding facility construction.