• Title/Summary/Keyword: 계산기하

Search Result 893, Processing Time 0.023 seconds

The Crystal and Molecular Structure of 25,26,27,28-Tetrnacetoxy[4]Arene${\cdot}$Monohydrate (25,26,27,28-테트라아세트오키시[4]에렌${\cdot}$일수화물의 결정 및 분자구조)

  • Choong Tai Ahn;Kwanghyun No
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.3
    • /
    • pp.344-350
    • /
    • 1993
  • 25,26,27,28-Tetraacetoxycalix[4]arene·monohydrate is orthorhombic, space group Pbca with a = 14.979(4), b = 15.154(4), c = 27.890(3) ${\AA}$, Z = 8, V = 6330.6 ${\AA}^{-3}$, D$_c$ = 1.28 $g{\cdot}cm^{-3}$, (Mo K${\alpha}$) = 0.71069 ${\AA}$, ${\mu}$ = 0.86 cm$^{-1}$, F(000) = 2600, and R = 0.069 for 3376 unique observed reflections with I > 1.0 ${\sigma}$(I). The structure was solved by direct methods and refined by cascade diagonal least-squares refinement. All the C-H bond lengths(= 0.96 ${\AA}$), the methyl groups and the methylene groups are fixed and refined as the rigid groups with ideal geometry. The macrocycle exists in the 1,3 alternate conformation (by Conforth) making the angles of 110.7, 684, 113.7 and 68.8$^{\circ}$ between the benzene rings and the methylenic mean plane, and four each acetoxy groups are twisted away from their own benzene rings with the angles of 68.2, 97.6, 78.9 and 71.3$^{\circ}$, respectively. The relative dihedral angles between two opposite side of the benzene rings are 135.6$^{\circ}$ for the rings (1) and (3) and 135.2$^{\circ}$ for (2) and (4). A water molecule which has nearly the same height of the methylenic plane of the macrocycle in the c-axis, is located within the distances of 2.942(5) ${\AA}$ from the O(8) atom of the carbonyl group and 2.901 ${\AA}$ from, another O(2)(1/2-x, -1/2+y, z). The shortest contact between the molecule is 3.193 ${\AA}$ from the O(4) to the C(3)(1/2+x, 1/2-y,-z).

  • PDF

Analysis of Reinforcement Effect of Hollow Modular Concrete Block on Sand by Laboratory Model Tests (실내모형실험을 통한 모래지반에서의 중공블록 보강효과 분석)

  • Lee, Chul-Hee;Shin, Eun-Chul;Yang, Tae-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.7
    • /
    • pp.49-62
    • /
    • 2022
  • The hollow modular concrete block reinforced foundation method is one of the ground reinforcement foundation methods that uses hexagonal honeycomb-shaped concrete blocks with mixed crushed rock to reinforce soft grounds. It then forms an artificial layered ground that increases bearing capacity and reduces settlement. The hollow modular honeycomb-shaped concrete block is a geometrically economical, stable structure that distributes forces in a balanced way. However, the behavioral characteristics of hollow modular concrete block reinforced foundations are not yet fully understood. In this study, a bearing capacity test is performed to analyze the reinforcement effectiveness of the hollow modular concrete block through the laboratory model tests. From the load-settlement curve, punching shear failure occurs under the unfilled sand condition (A-1-N). However, the filled sand condition (A-1-F) shows a linear curve without yielding, confirming the reinforcement effect is three times higher than that of unreinforced ground. The bearing capacity equation is proposed for the parts that have contact pressure under concrete, vertical stress of hollow blocks, and the inner skin friction force from horizontal stress by confining effect based on the schematic diagram of confining effect inside a hollow modular concrete block. As a result of calculating the bearing capacity, the percentage of load distribution for contact force on the area of concrete is about 65%, vertical force on the area of hollow is 16.5% and inner skin friction force of area of the inner wall is about 18.5%. When the surcharge load is applied to the concrete part, the vertical stress occurs on the area of the hollow part by confining effect first. Then, in the filled sand in the hollow where the horizontal direction is constrained, the inner skin friction force occurs by the horizontal stress on the inner wall of the hollow modular concrete block. The inner skin friction force suppresses the punching of the concrete part and reduces contact pressure.

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF