• Title/Summary/Keyword: 계면접착

Search Result 821, Processing Time 0.022 seconds

MICROTENSILE BOND STRENGTH OF DENTIN BONDING ADHESIVES ON BOVINE TEETH (Bovine teeth에 대한 수 종 상아질 접착제의 미세인장결합강도)

  • Song, Eun-Ju;Kim, Jae-Moon;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.420-429
    • /
    • 2007
  • The purpose of this study was to compare the micro ensile bond strength to bovine dentin of several adhesives (SM, Scotch $Bond^{TM}$ Multipurpose; SB, $Adper^{TM}$ Single Bond 2; SE, $Clearfil^{(R)}$ SE Bond; AQ, AQ $Bond^{TM}$; TS, $Clearfil^{(R)}$ tri-S Bond). Except SM and SB, they have a simplified one- or two-step application protocols in compare with the dentin adhesives conventional three-step protocols. For the microtensile bond strength test, the labial surfaces of bovine incisors were used. Following exposure of dentin layer, according to their manufacturer's directions, each dentin adhesives were applied and composite resin blocks were constructed. The teeth were sectioned for specimen and tested microtensile bond strength. Also observed the fracture mode of interface. The obtained results were as follows : 1. The microtensile bond strength values ranged from 51.34 to 24.04 MPa on dentin(in decreasing order, SE, SM, SB, AQ and TS). 2. The highest microtensile bond strength was by SE and SM on bovine dentin, and the lowest by AQ and TS. 3. SM, SB and SE showed cohesive failures and adhesive failure but AQ, TS presented almost adhesive failures. In summary, microtensile bond strengths of single-step adhesives (AQ and TS) on bovine dentin were significantly lower than those of multi-step adhesives (SM, SB and SE) (p<0.05).

  • PDF

CUSPAL DEFLECTION IN CLASS V CAVITIES RESTORED WITH COMPOSITE RESINS (5급 와동의 복합레진 수복 시 발생되는 교두굴곡에 관한 연구)

  • Park, Jun-Gyu;Lim, Bum-Soon;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of the polymerization shrinkage and modulus of elasticity of composites on the cusp deflection of class V restoration in premolars. The sixteen extracted upper premolars were divided into 2 groups with similar size. The amounts of cuspal deflection were measured in Class V cavities restored with a flowable composite (Filtek flow) or a universal hybrid composite (Z-250). The bonded interfaces of the sectioned specimens were observed using a scanning electron microscopy (SEM). The polymerization shrinkage and modulus of elasticity of the composites were measured to find out the effect of physical properties of composite resins on the cuspal deflection. The results were as follows. 1. The amounts of cuspal deflection restored with Filtek flow or Z-250 were $2.18\;{\pm}\;0.92{\mu}m$ and $2.95\;{\pm}\;1.13\;{\mu}m$, respectively. Filtek flow showed less cuspal deflection but there was no statistically significant difference (p > 0.05). 2. The two specimens in each group showed gap at the inner portion of the cavity. 3. The polymerization shrinkages of Filtek flow and Z-250 were 4.41% and 2.23% respectively, and the flexural modulus of elasticity of cured Filtek flow (7.77 GPa) was much lower than that of Z-250 (17.43 GPa). 4. The cuspal deflection depends not only on the polymerization shrinkage but also on the modulus of elasticity of composites.

Recovery of Covalently Linked Fatty Acid Monolayer on the Hair Surface Using Biomimetic Lipid (생체모사 지질을 이용한 모발 표면에 공유 결합된 지방산 단분자층의 회복)

  • Kim, Ei-Suk;Son, Seong-Kil;Lee, Cheon-Koo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.2
    • /
    • pp.139-145
    • /
    • 2012
  • There is a unique type of fatty acid in the hair surface. 18-methyleicosanoic acid (18-MEA) is an unusual anteiso fatty acid covalently linked to the outermost surface of hair cuticle. A layer of 18-MEA is located in the upper ${\beta}$-layer of the CMC that is responsible for the low surface energy and low friction resistance of the hair's outer surface. The high mobility of 18-MEA molecule facilitates spreading of extraneous lipid by decreasing interfacial shear strength. In this study, we introduced N-hydroxyl succinimidyl ester functional group to the one end of C10 - 40 isoalkyl acid for regenerating hair surface with covalently bound fatty acid layer. The re-hydrophobicization of hair surface has been investigated by contact angle measurement. The inner moisture content of hair at different levels of humidity (40, 55, 70 %RH) was measured by electric moisture analyzer. Treatment with Hydroxysuccinimidyl C10 - 40 Isoalkyl Acidate (HCIA) was supposed to make hair surface smoother by filling the cracks between cuticles with covalently bound fatty acid monomolecular layer like cuticle glue. This glue effect was also confirmed with line profile of AFM images. Therefore, the moisture and structural components of inner hair were not easily flown out and the optimum moisture content could be kept constantly though the outside humidity level was changed. The lateral force microscopy (LFM) by using atomic force microscope showed that the friction force of hair surface treated with HCIA was decreased. It also showed the constantly sustained friction value even after shampooing repeated 15 times.

A Study of Damage Sensing and Repairing Effect of CNT Nanocomposites (손상감지용 CNT 나노복합재료의 손상 감지능 및 보강효과 연구)

  • Kwon, Dong-Jun;Wang, Zuo-Jia;Choi, Jin-Young;Shin, Pyeong-Su;Park, Joung-Man
    • Composites Research
    • /
    • v.27 no.6
    • /
    • pp.219-224
    • /
    • 2014
  • Nancomposites manufacture has been developed rapidly, because of reinforcing effects of CNT in terms of mechanical, electrical and thermal properties. In this study, 10 wt% CNT paste was fabricated with good dispersion state and easy processability. Damage sensing and reinforcing effect of CNT paste were investigated in nanocomposites. 10 wt% CNT paste exhibited better tensile and flexural properties than those of general 1 wt% CNT nanocomposites. To observe the healing effect of CNT paste, a crack was made artificially with 30wt% CF30wt%/PP composites, and the CNT paste was filled inside the crack. The damage sensing of CNT paste in CF30wt%/PP composites was investigated by electrical resistance measurement and mechanical tests. CNT paste exhibited good reinforcing effect in mechanical properties of CF30wt%/PP composites, and this reinforcing effect was getting better with larger cracks. The reason was because CNT paste had good interfacial adhesion with CF30wt%/PP composites to resist crack propagation. In electrical resistance measurement, there was a jump in electrical resistance signal at the adhesion interface. The jumping signal could be used to predict fracture of CF/PP composites. CNT nanocomposites for damage sensing had crack reducing effect and damage detection using electrical resistance method.

Physical Properties and Electrical Conductivity of PAN-based Carbon Fiber Reinforced Paper (PAN계 탄소섬유 강화 종이의 물리적 특성 및 전기전도도)

  • Jang, Joon;Lee, Chang-Ho;Park, Kwan-Ho;Ryu, Seung-Kon
    • Korean Chemical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.602-608
    • /
    • 2006
  • Carbon fiber (CF) reinforced papers using polyacrylonitrile (PAN) based CF and wood pulp were prepared by varying the lengths and the concentrations of CF, and the basis weight of paper to investigate adhesive state between CF and pulp, and physical properties and electrical conductivity of the paper. The reinforcement was caused by physical entanglement and adhesion at the interface of the different fibers rather than by chemical bonds. The tear strength and the thickness of the paper increased as increasing the concentration of CF, while the tensile and the burst strength of the paper decreased. The improved dispersion of CF in the paper was obtained from mixing shorter CF, but the maximum electrical conductivity of the paper was gained from mixing 10 mm chopped CF. The electrical conductivity of the paper increased sharply from 2 wt% to 8 wt% of CF showing S-curve, and increased linearly as increasing the basis weight of the paper. Therefore, in order to improve the electrical conductivity and the physical property of the paper, the increase of basis weight of the paper is also important as the increase of CF content in the paper.

SURFACE ROUGHNESS AND MICROLEAKAGE OF CLASS V COMPOSITE RESTORATIONS : EFFECT OF SURFACE SEALING (치경부 5급 와동 수복물의 표면 거칠기와 미세누출에 관한 연구 : 표면 전색의 효과)

  • Kim, Min-Jeong;Lee, Mi-Jeong;Yu, Mi-Kyung;Park, Soo-Joung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.22-30
    • /
    • 2005
  • The purpose of this study was to compare the effect of surface sealing materials on microleakage and surface roughness in Class V composite restorations. Twenty five standardized Class V cavity preparations were made on the facial surface of human premolars and were randomly assigned to 5 groups. The teeth were restored with Z-250 after applying Single Bond. Following 7 days storage in distilled water at $37^{\circ}C$, the restorations were sealed as following systems : No sealing ; Single Bond Adhesive ; Biscover ; Fortify ; Optiguard. Then, toothbrush abrasion test was conducted using a wear testing machine. Surface roughness was measured by means of profilometer before and after toothbrushing and the results were statistically analysed by using a paired t-test and ANOVA. The bonded interfaces and the changes of surface roughness were examined by SEM. For microleakage test, specimens were stained in a $2\%$ methylene blue solution, then longitudinally sectioned and analyzed for leakage at occlusal and cervical interfaces using stereomicroscope. The results were statistically analysed by using a Kruskal-Wallis and Mann-Whitney U test. Surface roughness was increasing in all groups after toothbrushing, but no statistically significant differences. In SEM observation, surface sealant was partially retained and partially detached in bonded interfaces. Especially, microgap was identified in cervical margins. In microleakage test, there was better seal in the enamel region and a significant difference between groups at occlusal margin. Control group and Single Bond group had significantly better marginal seal at enamel margin than cervical margin.

Interfacial Evaluation and Microfailure Sensing of Nanocomposites by Electrical Resistance Measurements and Wettability (전기저항측정법 및 젖음성을 이용한 나노복합재료의 미세파손 감지능 및 계면물성 평가)

  • Park, Joung-Man;Kwon, Dong-Jun;Shin, Pyeong-Su;Kim, Jong-Hyun;Baek, Yeong-Min;Park, Ha-Seung
    • Composites Research
    • /
    • v.30 no.2
    • /
    • pp.138-144
    • /
    • 2017
  • Damage sensing of polymer composite films consisting of poly(dicyclopentadiene) p-DCPD and carbon nanotube (CNT) was studied experimentally. Only up to 1st ring-opening polymerization occurred with the addition of CNT, which made the modified film electrically conductive, while interfering with polymerization. The interfacial adhesion of composite films with varying CNT concentration was evaluated by measuring the wettability using the static contact angle method. 0.5 wt% CNT/p-DCPD was determined to be the optimal condition via electrical dispersion method and tensile test. Dynamic fatigue test was conducted to evaluate the durability of the films by measuring the change in electrical resistance. For the initial three cycles, the change in electrical resistance pattern was similar to the tensile stress-strain curve. The CNT/p-DCPD film was attached to an epoxy matrix to demonstrate its utilization as a sensor for fracture behavior. At the onset of epoxy fracture, electrical resistance showed a drastic increase, which indicated adhesive fracture between sensor and matrix. It leads to prediction of crack and fracture of matrix.

IN VITRO STUDY ON APICAL SEAL AND SEM MORPHOLOGY IN CANALS FILLED WITH RESIN-BASED ROOT CANAL SEALER AND SELF-ETCHING PRIMER (SELF-ETCHING PRIMER와 레진계 근관 SEALER 사용시 근관벽의 형태와 치근단 근관밀폐에 대한 실험적 연구)

  • Kang, Sam-Hee;Park, Dong-Sung;You, Heyon-Mee;Oh, Tae-Seok
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.543-549
    • /
    • 2000
  • Gutta-percha와 근관sealer를 사용한 근관 충전은 가장 많이 이용되고 성공률이 높은 방법이지만, 현재 사용되는 모든 근관sealer는 미세누출을 나타낸다. 따라서 더 효과적인 근관 폐쇄를 이루기 위한 재료 및 방법들이 연구되어왔다. 이중 상아질 접착제는 근관 충전재와 함께 사용되어 미세누출을 감소시키지만, 근관 내에 사용하기에 술식이 복잡하고 기술이 요구된다. 본 연구의 목적은 gutta-percha와 레진계 근관 sealer로 충전한 근관에서 self-etching primer를 미리 도포한 경우와 도포하지 않은 경우의 치근단 미세누출을 비교하고, self-etching primer를 도포함에 있어 근관 내에 적용하는 방법에 따른 미세누출을 비교하는 것이다. 또한 근관sealer와 상아질 계면을 주사전자현미경으로 관찰하여, 이 결과를 미세누출과 관련시켜보고자 하였다. 36개의 발거된 사람의 단근치에서 치관부를 절단, 제거하고 ProFile로 근관 형성한 후, 무작위로 선택하여 4개의 군으로 분류하였다. 1군에서는 주사기와 30게이지 주사 바늘로 self-etching primer를 근관 내에 적용하였고, 2군에서는 self-etching primer를 paper point에 적셔 근관 내에 적용하였다. 3군에서는 self-etching primer를 적용하지 않았다. 1, 2, 3군의 치아를 gutta-percha와 AH26 sealer를 사용하여 continuous wave 충전법으로 충전한 후 치근단공 주위 3mm를 제외한 치근변에 nail polish를 2회 도포하였고, 4군(음성 대조군)은 치근면 전체에 도포하였다. 1군과 2군에서 각각 2개의 치아는 주사전자현미경적 관찰을 위해 준비하였다. 모든 치아를 Methylene Blue 수용액에 48시간동안 침적, 수세한 후 치아 장축에 평행하게 양분하여 10배의 실물확대현미경 하에서 치근단 색소 침투를 관찰하였다. Self-etching primer를 도포한 군과 도포하지 않은 군 사이에는 평균 미세누출량에 유의한 차이가 없었다. 주사 바늘로 적용한 군과 paper point로 적용한 군 사이에도 평균 미세누출량에 유의한 차이가 없었다. 상아질과 근관 sealer계면의 주사전자현미경 관찰 결과 일부분에서 긴밀한 접착 관계를 나타내었고, 다른 부분에서는 간극을 나타내었다.

  • PDF

Effects of Cavity Configuration on Bond Strength and Microleakage of Composite Restoration (와동의 형태에 따른 복합레진의 결합강도 및 변연누출에 관한 연구)

  • Choi, Seung-Mo;Choi, Gi-Woon;Choi, Kyoung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.479-487
    • /
    • 2002
  • 복합레진의 중합시 발생하는 수축과 응력은 와동의 형태에 의하여 영향을 받으며 이는 수복재는 물론 접착계면의 물성을 결정하는 요인이 된다. 본 연구는 다양한 C-factor를 갖는 와동에 상아질 접착제 Clearfil SE Bond(Kuraray)를 도포하고 혼합형 복합레진인 Clearfil AP-X(Kuraray)와 미세혼합형의 Esthet-X(Dentsply)를 충전하여 미세인장강도 및 변연누출을 측정 평가함으로써 중합수축이 수복물과 치아계면에 미치는 영향을 평가하고자 시행하였다. 98개의 Bovine 하악전치를 이용하여 표면의 상아질을 #600 SiC paper로 연마한 대조군 및 와동의 넓이를 조절하여 C-factor 2.3, 3.0, 3.7이 되도록 제작한 실험군 와동에 복합레진을 충전한 후 37의 증류수에 24시간 보관하였다. 저속 diamond saw(Buehler)를 이용하여 1mm 두께로 수직절단 후 고속 diamond point(#104 Shofu)를 이용하여 단면적 1mm$^2$가 되도록 hour-glass모양으로 형성하여 시편을 제작하였고, Universal testing machine(EZ-Test; Shimadzu, Japan)에 시편을 부착하고 cross head speed 1mm/min으로 인장력을 가하여 미세인장 결합강도를 측정하였다. 각 C-factor에 따른 변연누출실험을 위하여 복합레진이 수복된 치아를 37$^{\circ}C$의 증류수에 24시간 보관한 후 와동을 제외한 부위에 nail varnish를 도포하고 3mol/L silver nitrate용액에 24시간 암보관한 다음 수세하여 현상액에 24시간 경과시킨 후 치아의 장축에 따라 절단하여 침투된 색소의 정도를 광학현미경상에서 40배로 관찰하였다. 각각의 실험결과는 ANOVA/Tukey's test 및 Kruskal-Wallis non-parametric independent analysis와 Mann-Whitney U test에 의하여 통계 분석하여 다음과 같은 결론을 얻었다. 1. 대조군에 있어서 혼합형 복합레진의 미세인장 결합강도는 미세혼합형에 비하여 높았으며, 실험군 사이에는 유의차를 보이지 않았다. 2.모든 복합레진의 미세인장 결합강도는 와동의 C-factor증가에 따라 감소하는 경향을 나타내었고, 혼합형 복합레진의 실험군은 대조군에 비하여 낮게 나타났으며, 미세혼합형 복합레진에서는 유의차를 보이지 않았다. 3. 절단측 및 치은측 변연부의 미세누출정도는 혼합형 복합레진이 미세혼합형에 비하여 대체로 높게 나타났다. 4. 모든 실험군에서 미세누출은 C-factor증가에 따라 증가하였고 절단측에 비하여 치은측 변연이 높게 나타났으나 통계학적 유의차는 보이지 않았다. C-factor의 변화에 대하여 필러함량과 탄성계수가 높은 혼합형 복합레진이 미세혼합형에 비하여 더 민감한 결과를 보인다. 이는 복합레진 수복시 재료의 선택과 중합수축의 적절한 조절이 중요한 요소임을 시사한다.

이산화탄소를 이용한 방사능 오염 세척 기술개발

  • Ko, Moon-Sung;Park, Kwang-Heon;Ryu, Jung-Dong;Kim, Yang-Eun;Lee, Bum;Park, Hyun-Taek
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.59-59
    • /
    • 2000
  • 원자력발전소 1차계통과 격납용기 내부에서 사용되는 주요 부품들은 운전중에 발생한 방사 성 물질들의 침투와 홉착에 의해 오염되어 간다. 이 오염된 부품 및 장비, 공구, 방호복, 방호모자, 작업화 등의 세정과 정비를 위해서는 제염이 선행되어야 한다. 현재의 제염법은 2차 방사성 폐기물을 발생하는 문제점이 있다. 따라서I 2차 폐기물의 발생을 근원적으로 줄일 수 있는 새로운 제염방안이 절실히 요구되고 있는 실정이다. 본 논문에서는 이러한 문제점을 해결할 수 있는 제염법을 개발하기 위해 2가지 방법을 적용하였다. 첫째로, 원자력 발전소에 서 나오는 방사능 오염 세탁물 제염을 위한 액체 및 초임계 이산화탄소를 이용한 방사능 오염물 제염기를 개발하였다. 제염기는 반응기(16 liteer), 회수시스템 그리고 저장용기로 구성되어있다. 세정에 사용된 모든 이산화탄소는 회수되어 재사용 되어지므로 2차 폐기물의 발생을 근원적으로 없앨 수 있다. 제염성능실험결과 제염지수가 목표치보다는 낮았다. 이는 제염 기에 계면활성제와 기계적인 힘을 가한다면 높은 제염지수를 얻을 수 있을 것으로 예상된다. 둘째로, 발전소에서 나오는 오염된 공구나 장비의 세척을 위한 가변형 노즐 드라이 아이스 세척 장치를 개발하였다. 표면세정시 얼음층 형성방지를 위하여 열공급장치를 부착하였다. 유라표면에 지문을 묻혀 실험한 결과 쉽게 제거되었다. 실제 발전소에 있는 P Pump-housing의 표면을 실험한 결과 방사능의 약 40-80%가 제거되었다. 이 장치는 검출기, 제어장치, 용액상에서 세척될 수 없는 장치에 적용할 수 있는 효율적인 세척법이다. 이는 프리프레그의 표면처리 가 충과 충간의 접착강도를 증가시키고 또한 탄소섬유와 에폭시 간의 계면력을 증가시킨데 기인하는 것으로 사려된다.되었으며, duty-on 시간의 증가에 따라 $Cr_2N$ 상의 형성이 점점 많아져 80% duty-on 시간 경우에는 거의 CrN과 $Cr_2N$ 상이 공존하는 것으로 나타났다. 또한 duty-on 시간이 증가할수록 회절피크의 세기가 증가하여 결정화가 더 많이 진행되어짐을 알 수 있었다. 마찬가지로 바이어스 펄스이 주파수에 다른 결정성의 변화도 펄스의 주파수가 증가할수록 박막이 결정성이 좋아지고 $Cr_2N$ 상이 쉽게 형성되었다. 증착 진공도에 따른 결정성은 상대적으로 질소의 농도가 높은 낮은 진공도에서는 CrN 상이 주로 형성되었으며, 반대로 높은 진공도에서는 $Cr_2N$ 상이 많이 만들어졌다. 즉 $1.3{\times}10^{-2}Torr$의 증착 진공도에서는 CrN 상만이 보이는 반면 $9.0{\tiems}1-^{-2}Torr$ 진공도에서부터 $Cr_2N$ 상이 형성되기 시작하여 $5.0{\tiems}10^{-2}Torr$ 진공도에서는 두개의 상이 혼재되어 있음을 알 수 있었다. 박막의 내마모성을 조사한 결과 CrN 박막의 마찰 계수는 초기에 급격하게 증가한 후 0.5에서 0.6 사이의 값으로 큰 변화를 보이지 않았으며, $Cr_2N$ 박막도 비슷한 거동을 보였다.차 이, 목적의 차이, 그리고

  • PDF