• Title/Summary/Keyword: 경시변화

Search Result 602, Processing Time 0.043 seconds

Fluidity and Hydration Properties of Cement Paste Added Zinc Fluosilicate(ZnSiF6, aq.) (규불화아연(ZnSiF6, aq)이 첨가된 시멘트의 유동성과 수화특성)

  • Kim, Do-Su;Khil, Bae-Su;Lim, Heon-Seong;Nam, Jae-Hyun;Rho, Jae-Seong
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.2
    • /
    • pp.178-183
    • /
    • 2002
  • Zinc fluosilicate ($ZnSiF_6$, 15% aqueous solution) was prepared using zinc oxide (ZnO) and fluosilicic acid ($H_2SiF_6$) by soluiton synthetic method. The fluidity and hydration properties of cement which was added $ZnSiF_6$ (aq.) as an additive for cement were studied. At water to cement ratio (W/C) equals to 0.45, the initial fluidity and slump loss of cement paste which the addition of $ZnSiF_6$ (aq.) was increased from 1.0% to 4.0% based on cement weight were investigated. Initial fluidity of cement paste was measured by mini-slump test and slump loss was examined by measuring the fluidity variation of cement paste with time elapsed from 0 min to 120 min at intervals 30 min. Also, the effect of $ZnSiF_6$ addition on the setting and hydration of cement paste when $ZnSiF_6$ increased in the addition range 1.0% to 3.0% were investigated. The fluidity of cement paste which was added 2.1% $ZnSiF_6$ (aq.) presented the highest value among all addition ranges. The setting time of cement paste was retarded gradually and the heat evolution of hydrated cement was reduced with the increasing of $ZnSiF_6$ addition.

Evaluation of Fluidity Over Time and Mechanical Properties of Cement-based Composite Materials for 3D Printing (3D 프린팅용 시멘트계 복합재료의 경시변화 및 역학적 특성평가)

  • Seo, Eun-A;Lee, Ho-Jae;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.73-80
    • /
    • 2022
  • This study evaluated changes in fluidity and rheological properties over time for 3D printed composite materials, and evaluated compressive strength and splitting tensile strength properties for laminated and molded specimens. The composite material for 3D printing starts to change rapidly after 30 minutes of extrusion, and the viscosity of the material tends to be maintained up to 90 minutes, but it was confirmed that construction within 60 minutes after mixing is effective. The compressive strength of the laminated test specimen showed equivalent or better performance at all ages compared to the molded test specimen. In the stress-strain curve of the laminated specimen, the initial slope was similar to that of the molded specimen, but the descending slope was on average 1.9 times higher than that of the molded specimen, indicating relatively brittle behavior. The splitting tensile strength of the P-V laminated specimen was about 6% lower than that of the molded specimen. It is judged that this is because the interfacial adhesion force against the vertical load is affected by the pattern direction of the laminated test specimen.

Changes in Insulation Performance of Organic Insulating Materials for Building Construction by Accelerated Durability Test Conditions (가속내구성 조건에 따른 건축용 유기계 단열재의 단열성능 변화)

  • Lim, Soon-Hyun;Lee, Gun-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.595-601
    • /
    • 2016
  • The insulation performance of the insulation currently used in building structures is reflected only during design based on initial performance and the reduction in heat insulation performance due to the degradation of long-term durability is not reflected. This study reviewed the degradation of heat insulation performance due to the durability degradation of insulating materials through the accelerated durability test. The study findings showed that the foamed polystyrene insulation bead method did not show performance degradation due to aging in the standard environmental condition and laboratory accelerated test condition but the performance is degraded in the freeze-thaw test condition. On the other hand, in the case of the extrusion method, the degradation of the heat insulation performance was less in the freeze-thaw test condition, but the rapid performance degradation was caused by the release of the internal gas at the beginning of aging. In addition, the hard polyurethane foam insulation showed better initial insulation performance than other insulation materials, but the performance was found to be degraded somewhat under laboratory accelerated test conditions and freeze-thaw test conditions.

Time-elapes Change of Oil-polluted Taean Coastal Area by the Hebei Spirit Oil Spill Incident - Focusing on the Field Surveying(Vision and Photos) - (허베이스피리트호 원유유출사고로 오염된 태안연안의 경시변화 -현장관측(육안 및 사진분석)을 중심으로-)

  • Jung, Jae-Sung;Cheong, Cheong-Jo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.3
    • /
    • pp.111-123
    • /
    • 2009
  • The purpose of this study is to investigate the time-elapse change of oil-polluted Taean coastal area with by Herbei Spirit oil spill incident. From Mandae of Iwonmeyon to Padori beach of Sowonmeyon, field monitering was conducted at eleven surveying points surveying. The specific conclusions from this study are as follows. The residual oil was not founded at ten surveying points, but the crude oil remained under the ground at the Groompo beach one year passed since the oil spill. Because the efforts of volunteers over millionaires and inhabitants for cleaning and reciprocating actions of waves, the oil-polluted coastal area by Herbei Spirit oil spill incident. It is guessed that a part of stranded oil spilled from the incident was degraded by physical, chemical, and biological weathering and the residue was dispersed in tidal and subtidal zone with oil-minerals aggregates(OMA).

  • PDF

Dissipation and Removal Rate of Dichlofluanid and Iprodione Residues on Greenhouse Cherry Tomato (방울토마토중 Dichlofluanid 및 Iprodione의 생산단계별 잔류농약 경시변화)

  • Choi, Kyu-Il;Seong, Ki-Yong;Jeong, Tae-Gyun;Lee, Joo-Hwan;Hur, Jang-Hyun;Ko, Kwang-Yong;Lee, Kyu-Seung
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.4
    • /
    • pp.231-236
    • /
    • 2002
  • We studied the residual patterns of two fungicides, dichlofluanid and iprodione, in cherry tomato greenhouse after applying with the recommended and double dose. Also, the degradation patterns during storage periods of up to ten days were compared between at room temperature (20$^{\circ}C$) and at cold temperature (4$^{\circ}C$). Removal rates of fungicides by washing with tap-water and detergent solution (0.1%, 0.2%) were measured. Half-lives of dichlofluanid and iprodione in greenhouse cherrytomato were 2.2$\sim$3.5 and 3.3$\sim$5.4 days, respectively. During the storage period, the residues were dissipated more slow. Removal rates were 62.8$\sim$80.3% by tap-water, 60.4$\sim$83.1% by 0.1% detergent solution, and 65.3$\sim$77.6% by 0.2% detergent solution. So, we can predict of terminal residues from cultivation period to marketing, storage and consuming.

A Study of Elapsed Time Change on Concrete for Top-Down Method (역타공법 적용을 위한 콘크리트 경시변화 특성 연구)

  • 정근호;이종균;박선길;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.487-492
    • /
    • 1999
  • The purpose of this study to find the mixture of concrete for Top-Down method. Throughout test of elapsed time change and L-type flow, it was proposed basic performance and level of top-down method concrete. When change as to elapsed time is considered, so series of F10 added 10% S.P satisfied slump and demanded flow (60$\pm$5cm), and L-type slump, L-type flow satisfied liquidity, it can be considered basic mixture of designed actual frame later.

  • PDF

500kg/cm$^2$고강도 콘크리트 - 재료특성$\cdot$현장시공성에 관한 연구

  • 안재현;권영호
    • 어항어장
    • /
    • s.18
    • /
    • pp.69-77
    • /
    • 1992
  • 고강도 콘크리트의 실용화 일환으로 설계기준강도 500kg/cm$^2$ 이상인 고강도 콘크리트의 현장 B/P 생산과 실대구조물의 시공성 및 강도, 온도 특성에 관한 연구를 수행하였다. 이러한 연구를 위해 현장 최적배합비 선정과 레미콘 운반시간에 따른 경시변화 시험을 수행하였고 실대구조물의 코아강도 및 콘크리트 내부온도를 측정하였다. 일반 현장재료와 장비의 사용으로도 고강도 콘크리트의 생산과 시공성을 확보할 수 있었으며 실대구조물의 코아강도가 500kg/cm$^2$ 이상을 나타냄으로써 고강도 콘크리트의 실용화에 대한 가능성을 확인할 수 있었다.

  • PDF

Time Course Change in Composition of Ginseng Polyacetylenes (인삼(人蔘) polyacetylene 조성(組成)의 경시변화(經時變化))

  • Han, Byung-Hoon;Song, Byung-Joon;Ro, Hwan-Sung
    • Korean Journal of Pharmacognosy
    • /
    • v.7 no.3
    • /
    • pp.191-193
    • /
    • 1976
  • It has been known that ginseng extract contains several polyacetylene components. But we found only two polyacetylene components in the freshly prepared ginseng extract. Long-term preservation of ginseng or ginseng extract produced many artifact polyacetylenes. The ratio of artifact/genuine polyacetylene was determined by TLC-densitometry on long-term preserved ginseng samples. The results indicated that the ratio was increased proportionally with the span of preservation.

  • PDF

Experimental Study on the Moisture Distribution in Concrete Specimens According to Different Compressive Strengt (콘크리트 강도차에 따른 함수율 분포의 변동에 관한 실험적 연구)

  • Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.195-196
    • /
    • 2019
  • The temperature and relative humidity in concrete change with the passage of time depending on factors such as compressive strength. They are also different depending upon internal depth of concrete. In this study, we have measured the change of the temperature and relative humidity in the concrete for two years to act as the parameters to evaluate the concrete durability and effective maintenance.

  • PDF