• Title/Summary/Keyword: 경사에코

Search Result 49, Processing Time 0.028 seconds

MR spectroscopy using single-shot RF localization technique (단일 RF 펄스를 사용한 3차원 체적 선택 방법을 이용한 MR 스펙트로 스코피)

  • Rim, C.Y.;Chun, K.W.;Ra, J.B.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.51-54
    • /
    • 1989
  • In last several years, a number of volume localization techniques, such as ISIS, VSE, SPARS and STEAM etc., have been developed for the MR spectroscopy. These localizing techniques, however, require application of several RF pulses for the 3-D volume selection and suffer from T1 and T2 decays due to relatively long RF excitation time. In this paper, we propose a single-shot RF pulse localization technique to achieve the localized 3-D volume selection. This technique combines the cylindrical volume selection technique with a radial gradient coil with single-shot RF pulse and the oscillating selection gradient technique, so thai it minimizes the volume selection time. We report some experimental results obtained with the proposed method which appears promising for 3-D volume imaging and localized spectroscopy.

  • PDF

Analysis NPS Run-off Characteristics During Rainfall Event in upper Han-river Nae-Rin Cheon watershed (한강 상류 내린천 유역의 강우시 비점오염물질 유출특성 분석)

  • KI Cheol Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.471-471
    • /
    • 2023
  • 소양댐 상류 유역에 위치한 고랭지 밭에서 강우시 많은 양의 탁수가 유입되고 있어 상·하류지역사회에 갈등을 유발하고 하천 환경오염의 주범으로 지목되었다. 이에 환경부는 2007년부터 꾸준히 소양호 유역을 비점오염원 관리지역으로 지정하여 다양한 노력을 기울여왔으나 여전히 소양강 상류 수계의 강우시 흙탕물 발생이 지속적으로 문제가 되고 있다. 특히 고랭지 농업이 활발한 자운지구의 경우 고랭지 밭 경작 이외에도 나대지 상태로 방치되거나, 절삭지 보호가 제대로 이루어지지 않는 등 여러 가지 문제로 토사유출이 심각하게 발생하고 있어 흙탕물 관리가 필요한 실정이다. 이에 본 연구에서는 자운지구를 포함한 내린천 유역을 대상으로 강우유출수 모니터링을 수행하였으며, 모니터링 결과를 바탕으로 강우시 비점오염물질 유출 특성을 분석하였다. 강우유출수 모니터링은 2022년 3월부터 10월 중 총 5회를 수행하였으며, 내린천 유역 내 유량 측정망이 설치되어 있는 4개지점(양지교, 현리교, 하죽천교, 원대교)과 내린천 상류 2개지점(에코빌리지, 새터교) 총 6개 지점에서 강우유출수 모니터링을 실시하였다. 분석된 자료를 바탕으로 각 소유역별 EMC, 오염부하, 단위면적당 오염부하를 산정한 결과 하죽천교와 원대교의 단위면적 당 오염부하가 높게 나타났다. 이는 해당 소유역(내린천 하류)에서 발생한 강우강도가 상류에 비해 높았으며, 하죽천교는 유역내 농경지의 비율이 높고, 원대교는 가파른 경사도의 영향이 큰 것으로 판단된다. 또한, 하죽천교와 원대교 소유역에서 배출된느 흙탕물이 내린천 유역의 하천수질 오염에 상당한 기여를 하고 있는 것으로 나타났으며, 오염 우심 소유역에서 발생하는 흙탕물 저감을 위한 적절한 대책이 마련되어야 할 것으로 판단된다. 본 연구 결과와 같이 장기적인 모니터링을 통해 내린천 유역의 흙탕물 저감 대책 수립을 위한 기초자료로 활용할 수 있을 것으로 기대된다.

  • PDF

Gaussian Filtering Effects on Brain Tissue-masked Susceptibility Weighted Images to Optimize Voxel-based Analysis (화소 분석의 최적화를 위해 자화감수성 영상에 나타난 뇌조직의 가우시안 필터 효과 연구)

  • Hwang, Eo-Jin;Kim, Min-Ji;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.275-285
    • /
    • 2013
  • Purpose : The objective of this study was to investigate effects of different smoothing kernel sizes on brain tissue-masked susceptibility-weighted images (SWI) obtained from normal elderly subjects using voxel-based analyses. Materials and Methods: Twenty healthy human volunteers (mean $age{\pm}SD$ = $67.8{\pm}6.09$ years, 14 females and 6 males) were studied after informed consent. A fully first-order flow-compensated three-dimensional (3D) gradient-echo sequence ran to obtain axial magnitude and phase images to generate SWI data. In addition, sagittal 3D T1-weighted images were acquired with the magnetization-prepared rapid acquisition of gradient-echo sequence for brain tissue segmentation and imaging registration. Both paramagnetically (PSWI) and diamagnetically (NSWI) phase-masked SWI data were obtained with masking out non-brain tissues. Finally, both tissue-masked PSWI and NSWI data were smoothed using different smoothing kernel sizes that were isotropic 0, 2, 4, and 8 mm Gaussian kernels. The voxel-based comparisons were performed using a paired t-test between PSWI and NSWI for each smoothing kernel size. Results: The significance of comparisons increased with increasing smoothing kernel sizes. Signals from NSWI were greater than those from PSWI. The smoothing kernel size of four was optimal to use voxel-based comparisons. The bilaterally different areas were found on multiple brain regions. Conclusion: The paramagnetic (positive) phase mask led to reduce signals from high susceptibility areas. To minimize partial volume effects and contributions of large vessels, the voxel-based analysis on SWI with masked non-brain components should be utilized.

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.57-65
    • /
    • 2001
  • Purpose : $T_2$-weighted half courier Echo Planar Imaging (T2HEPI) method is proposed to reduce measurement time of existing EPI by a factor of 2. In addition, high $T_2$ contrast is obtained for clinical applications. High resolution single-shot EPI images with $T_2$ contrast are obtained with $128{\times}128$ matrix size by the proposed method. Materials and methods : In order to reduce measurement time in EPI, half courier space is measured, and rest of half courier data is obtained by conjugate symmetric filling. Thus high resolution single shot EPI image with $128{\times}128$ matrix size is obtained with 64 echoes. By the arrangement of phase encoding gradients, high $T_2$ weighted images are obtained. The acquired data in k-space are shifted if there exists residual gradient field due to eddy current along phase encoding gradient, which results in a serious problem in the reconstructed image. The residual field is estimated by the correlation coefficient between the echo signal for dc and the corresponding reference data acquired during the pre-scan. Once the residual gradient field is properly estimated, it can be removed by the adjustment of initial phase encoding gradient field between $70^{\circ}$ and $180^{\circ}$ rf pulses. Results : The suggested T2EPl is implemented in a 1.0 Tela whole body MRI system. Experiments are done with the effective echo times of 72ms and 96ms with single shot acquisitions. High resolution($128{\times}128$) volunteer head images with high $T_2$ contrast are obtained in a single scan by the proposed method. Conclusion : Using the half courier technique, higher resolution EPI images are obtained with matrix size of $128{\times}128$ in a single scan. Furthermore $T_2$ contrast is controlled by the effective echo time. Since the suggested method can be implemented by software alone (pulse sequence and corresponding tuning and reconstruction algorithms) without addition of special hardware, it can be widely used in existing MRI systems.

  • PDF

Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System (3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정)

  • Ryu, Jung Kyu;Oh, Jang-Hoon;Kim, Hyug-Gi;Rhee, Sun Jung;Seo, Mirinae;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose : $T_2{^*}$ relaxation time which includes susceptibility information represents unique feature of tissue. The objective of this study was to investigate $T_2{^*}$ relaxation times of the normal glandular tissue and fat of breast using a 3T MRI system. Materials and Methods: Seven-echo MR Images were acquired from 52 female subjects (age $49{\pm}12 $years; range, 25 to 75) using a three-dimensional (3D) gradient-echo sequence. Echo times were between 2.28 ms to 25.72 ms in 3.91 ms steps. Voxel-based $T_2{^*}$ relaxation times and $R_2{^*}$ relaxation rate maps were calculated by using the linear curve fitting for each subject. The 3D regions-of-interest (ROI) of the normal glandular tissue and fat were drawn on the longest echo-time image to obtain $T_2{^*}$ and $R_2{^*}$ values. Mean values of those parameters were calculated over all subjects. Results: The 3D ROI sizes were $4818{\pm}4679$ voxels and $1455{\pm}785$ voxels for the normal glandular tissue and fat, respectively. The mean $T_2{^*}$ values were $22.40{\pm}5.61ms$ and $36.36{\pm}8.77ms$ for normal glandular tissue and fat, respectively. The mean $R_2{^*}$ values were $0.0524{\pm}0.0134/ms$ and $0.0297{\pm}0.0069/ms$ for the normal glandular tissue and fat, respectively. Conclusion: $T_2{^*}$ and $R_2{^*}$ values were measured from human breast tissues. $T_2{^*}$ of the normal glandular tissue was shorter than that of fat. Measurement of $T_2{^*}$ relaxation time could be important to understand susceptibility effects in the breast cancer and the normal tissue.

Voxel-based Investigations of Phase Mask Effects on Susceptibility Weighted Images (화소 간 분석을 이용하여 자화율 가중 영상(SWI)에 나타난 위상 마스킹의 효과 분석)

  • Hwang, Eo-Jin;Kim, Min-Ji;Kim, Hyug-Gi;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.25-34
    • /
    • 2013
  • To investigate effects of phase mask on susceptibility-weighted images (SWI) using voxel-based analyses in normal elderly subjects. A three-dimensional (3D) gradient echo sequence ran to obtain SWIs in 20 healthy elderly subjects. SWIs with two (SWI2) and four (SWI4) phase multiplications were achieved with positive (PSWI) and negative (NSWI) phase masks to investigate phase mask effects. The voxel-based comparisons were performed using paired t-tests between PSWI and NSWI and between SWI2 and SWI4. Differences of signal intensities between magnitude images and SWI4 were larger than those between magnitude images and SWI2s. Differences of signal intensities between magnitude images and PSWIs were larger than those between magnitude images and NSWIs. Moreover, the signal intensities from NSWI2s and NSWI4s were greater than those from PSWI2s and PSWI4s, respectively. More differences of signal intensities between NSWI4 and PSWI4s were found than those between NSWI2s and PSWI2s in the whole brain images. The voxel-based analyses of SWI could be beneficial to investigate susceptibility differences on the entire brain areas. The phase masking method could be chosen to enhance brain tissue contrast rather than to enhance venous blood vessels. Therefore, it is recommended to apply voxel-based analyses of SWI to investigate clinical applications.

Comparison of In-Phase and Opposed-Phase FMPSPGR Images in Breath-hold T1-weighted MR IMaging of Liver (호흡정지 T1 강조 간 자기공명영상에서 동위상 역위상 FMPSPGR 영상의 비교)

  • 김명진;김만득;정재준;이종태;유형식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.142-147
    • /
    • 1997
  • Purpose: To compare the effectiveness of the in-phase (IP) sequence and the opposed-phase (Op) sequence in the detection of focal hepatic lesions in the single breath-hold hepatic MR imaging with fast gradient T1-weighted pulse sequences. Materials and Methods: IP and OP T1-weighted breath-hold imaging was performed using fast gradient echo sequences in 45 patients referred for known focal hepatic lesions, in which 78 lesions were detected. Three blind readers independently reviewed the images for lesion detectability. The signal-to-noise ratio (SNR) of the liver, the lesion-to-liver contrast-to-noise ratio (CNR) and the liver-to-spleen CNR were also compared. A consensus was reached by three readers to determine which sequence is better in image quality. Results: On OP images, 61(78%), 61(78%), and 63(89%) lesions were correctly identified for reader 1, 2 and 3, respectively. On IP images, 66(85%), 65(83%), and 65(93%) lesions were detected for each reader, respectively. When two image sets were combined, 71(91 %), 69(88 %), and 76(97%) lesions respectively were detected for each reader. In cases of hepatocellular carcinoma, liver-to-Iesion CNR was greater on the OP images(p (0.05), but in other lesions significant difference was not demonstrated. Liver-to-spleen CNR was higher on OP images(p ( 0.1), but the SNR of the liver was higher on the IP images. Conclusion: Use of both IP and OP imaging can be helpful to avoid erroneous missing of some focal hepatic lesions.

  • PDF

Alternative Technique of Aortic Valve Replacement -Implantation of Mechanical Aortic Valve at a Supra-Annular Level- (기계판막을 판륜상연에 위치시킨 대동맥판 치환술)

  • 최종범;이삼윤
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.504-509
    • /
    • 1996
  • When a valve prosthesis is to be implanted in the aortic position, simple interrupted suture, figure-of- eight suture, or horizontal mattress suture technique is used as a suture method. However, the suture techniques may be unacceptable for aortic valve replacement in patients with friable annulus caused by some lesions, such as endocarditis and degenerative change. We used an alternative technique for the aortic vlave replacement in 4 patients with valve endocarditis, ) patients with degenerative valvular lesion, and 1 with rheumatic valvular disease. Mattress sutures through the annulus were placed with pledgets on the ventricular side of the annulus, whi h resulted in implantation of the prosthesis at a supra-annular level. Mechanical valves of 21 mm or larger were implanted in the supra-annular position in all patients and there was no impeded motion of leaflets during the follow-up period of mean 13.3 mouths. The transvalvular pressure gradient was less than 6 mm Hg in 3 patients and 20 to 40 mm Hg in 5 patients. The supra-annular implantation of mechanical aortic valve using a vertical mattress suture technique may be a useful alternative method of aortic valve replacement for the selected patients with friable or destroyed aortic annulus.

  • PDF

Landscape Design for Masan Robot Land (마산로봇랜드 조경설계)

  • Yoon, Sung-Yung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.3
    • /
    • pp.115-125
    • /
    • 2010
  • A theme park is not just a recreational space for leisure activities, but also a place of storytelling as collected around abstract boundaries called themes. These stories are 'a space that tells the meaning' that the visitor is looking for and the Robot Land space offers robots, humans, and nature. This study is a description of the design strategy and content of the work which was elected as a subject of the subsequent rank negotiation of the Masan Robot Land design contest for the selection of a private contractor. The focus of the plan is, first, the organizational power of each space and the delivery power of a theme for the history of revisits, which might be considered depending on whether or not the theme park has been successful in the visitor's mind. Second, it is to actively use the potential of Masan, which is not only the key hub of the mechanical industry but also has beautiful coastal resources. First, they created a space that can flexibly react depending on the user's desire and the change of form, minimizing environmental damage by using a linear metabolism that can provide an amalgam of the elemental characteristics of robots, humans, and nature as motifs. They introduced a planting plan for the admissions square, an existing forest, slope, vacation spot, the inside of a complex, and Eco Island, etc. by utilizing symbolic meaning and adjusting to the spatial characteristics of each space. In addition, they sought a detailed space by setting up zones tailored to the use and character of the subject area, having exhibitions and education about robots, vacation facilities for lodgers, various recreational and commercial facilities, and space for utopian gardens as themes. They planned Masan Robot Land to be a true cultural space that creates mental richness on the basis of not only the economical effects but also local emotion.

SH Wave Scattering from Cracks: Comparisons of Approximate and Exact Solutions (SH파의 균열 산란장 해석: 근사해와 엄밀해의 비교)

  • Jeong, Hyun-Jo;Park, Moon-Cheol;Song, Sung-Jin;Schmerr, L.W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.354-361
    • /
    • 2004
  • This Paper describes a crack scattering model for SH wave based on the boundary integral equation(BIE) method, where the fundamental unknown is crack opening displacement(COD). When a time harmonic plane wave was incident on a 2-D isolated crack (slit) of width 2a, the COD distributions were numerically calculated as a function of ka. The calculated COD agreed well with results obtained with other methods. The far-field scattering amplitude, which completely characterizes the flaw response, was calculated in two ways. The Kirchhoff approximation and the BIE-COD exact formulation were compared in terms of incidence angle and frequency ka in a pulse-echo mode. Maximum response was obtained for both methods at the specular reflection direction. Away from the specular direction, the Kirchhoff approximation becomes less accurate. The time domain crack response was also calculated using a band-limited spectrum of center frequency 10 MHz. At oblique incidence to the crack both methods show the existence of an antisymmetric flash points occurring from the crack edge. The Kirchhoff approximation provides an exact time interval between flash points, although it unrealistically gives the same amplitude.