• Title/Summary/Keyword: 경량 콘크리트

Search Result 571, Processing Time 0.03 seconds

Effect of the Reinforcement Index on the Unbonded Tendon Stress of Post-tensioned Lightweight Concrete Beams (포스트텐션 경량콘크리트 보의 비부착 긴장재 응력에 대한 보강지수의 영향)

  • Mun, Ju-Hyun;Yang, Keun-Hyeok;Byun, Hang-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.89-90
    • /
    • 2010
  • Three post-tensioned lightweight concrete beams were tested to examine the effect of the reinforcement index on the unbonded tendon stress at ultimate strength of the beams. The reinforcement index selected for main variables were 0.06, 0.15, 0.30. Test results showed that the stress of the unbonded tendons in the ultimate strength of the post-tensioned lightweight concrete beams can be conservatively evaluated using the empirical equations specified in ACI 318-08.

  • PDF

Evaluation of Flexural Behavior of Lightweight Precast Panel with Ultra High Performance Concrete (초고성능 콘크리트를 적용한 경량 프리캐스트 패널의 휨 거동 평가)

  • Kim, Kyoung-Chul;Koh, Kyung-Taek;An, Gi-Hong;Son, Min-Su;Kim, Byung-Suk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.3
    • /
    • pp.269-275
    • /
    • 2020
  • In this study, flexural tests of precast concrete panels according to the thickness of cross-sectional and the with or not of reinforcement were carried out in order to develop and assess of a lightweight precast concrete panel using ultra high performance concrete. For the test, four panels were fabricated, and consisted of one normal concrete panel and three ultra high performance concrete panels. As a test result, it was found that the plain precast panel using ultra high performance concrete had a lower flexural performance than the reinforced normal concrete panel, regardless of the cross-sectional size. The flexural performance of the hollow-sectional precast panel applying ultra high performance concrete, is improved by 150% compared to that of the reinforced normal concrete panel. That is, through additional performance verification and optimization of the cross-sectional design of the panel, the ultra high performance concrete precast panel can be made lighter. Also, the practical use of lightweight precast panels with ultra high performance concrete can be available through evaluation on shear, joint connection and anchoring, etc.

Optimized Mixing Design of Lightweight Aerated Concrete by Response Surface Analysis (반응표면분석법에 따른 경량기포콘크리트 최적배합 도출에 관한 연구)

  • Lee, Sang-An;Jung, Chan-Woo;Kim, Wha-Jung;Ahn, Jung-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.745-752
    • /
    • 2009
  • This paper presents the optimized mixing design of lightweight aerated concrete using hydrogen peroxide. Design of experiments in order to the optimized mixing design was applied and commercial program (MINITAB) was used. Statistical analysis was used to Box-Behnken (B-B) method in response surface analysis. The influencing factors of experimental are unit cement content, water ratio and hydrogen peroxide ratio. According to the analysis of variance, at the hardened state, water ratio and hydrogen peroxide ratio affects on dried density, compressive strength and bending strength of lightweight aerated concrete, but unit cement content affects on only dried density. In the results of response surface analysis, to obtain goal performance, the optimized mixing design for lightweight aerated concrete using hydrogen peroxide were unit cement content of 800 kg/$m^3$, water ratio of 44.33% and hydrogen peroxide ratio of 10%.

A Physical Properties of Lightweight Foamed Concrete According to Lightweight Aggregate Types and Foaming agent Types (경량골재와 기포제 종류에 따른 경량기포 콘크리트의 물리적 특성)

  • Kim, Ha-Seog;Lee, Sea-Hyun;Sun, Jung-Soo;Kim, Jin-Man
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.4
    • /
    • pp.435-444
    • /
    • 2016
  • In Korea, approximately 48% of all households live in apartments, which are a form of multi-unit dwellings, and this figure increases up to 58%, when row houses and multiplex houses are included. As such, majority of the population reside in multi-unit dwellings where they are exposed to the problem of floor impact noise that can cause disputes and conflicts. Accordingly, this study was conducted to manufacture a high-weight, high-stiffness foamed concrete in order to develop a technology to reduce the floor impact noise. For the purpose of deriving the optimum mixing ratio for the foamed concrete that best reduces the floor impact noise, the amounts of the foaming agent, lightweight aggregate and binder were varied accordingly. Also, the target characteristics of the concrete to be developed included density of over $0.7t/m^3$, compressive strength of over $2.0N/mm^2$ and thermal conductivity of under 0.19 W/mK. The results of the experiment showed that the fluidity was very excellent at over 190 mm, regardless of the type and input amount of foaming agent and lightweight aggregate. The density and compressive strength measurements showed that the target density and compressive strength were satisfied in the specimen with 50% foam mixing ratio for foamed concrete and in all of the mixtures for the lightweight aggregate foamed concrete. In addition, the thermal conductivity measurements showed that the target thermal conductivity was satisfied in all of the foamed concrete specimens, except for VS50, in the 25% replacement ratio case for Type A aggregate, and all of the mixtures for Type B aggregate.

Mechanical Property of Foamed Light Weight Concrete with Wasted Expanded Poly-Styrene (폐스티로폼을 혼입한 경량기포콘크리트의 역학적 특성)

  • 오세출;서치호;신상태;김봉주
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.3
    • /
    • pp.285-293
    • /
    • 2001
  • To improve the vulnerable point and the mechanical property of the existing lightweight foamed concrete, this study was intend to manufacture the lightweight foamed concrete with wasted expanded poly-styrene, examinate and analyze the mechanical property of its. The experiment was being processed with mixing the wasted expanded poly-styrene maximum 40 % by stages and which was mainly basis on the practical mixture. The results of the experiment are following. The flow value is most affected by the mixtured rate of the wasted expanded poly-styrene. The more the mixtured ratio, the less the flow value and the more the more the unit quantity of cement and the W/C, the more the flow value. The apparent specific gravity indicated 0.31∼0.54 and which is seemed to be mainly included in the 0.4 degree and 0.5 degree that are regulated in the KS F 4039. The more the mixtured wasted poly-styrene ratio, the less the apparent specific gravity. The absorbing ratio which was depend on the mixture condition indicated 11 ∼46% and the more the mixtured ratio of the wasted expanded poly-styrene, the less the absorbing ratio remarkably. The compressive strength of the lightweight foamed concrete had a tendency to increase as the mixtured ratio of the wasted poly-styrene, the ratio quantity of cement and the apparent specific gravity increasing but as the ratio of bubble decreasing. The W/C affected little.

Moment-Curvature Relation of Concrete Filled Circular Steel Tubular Beam with Nonlinear Stress-Strain Properties (비선형 응력-변형률 특성을 갖는 콘크리트 충전 원형강관 보의 모멘트-곡률 관계)

  • Park, Woo-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.195-202
    • /
    • 2005
  • This paper presents moment-curvature analytical method of concrete filled steel tubular members considering intensity increase phenomenon by triaxial compression stress generation. For this purpose, this study considers buckling characteristics about compression department of steel members that filled up light weight and normal concrete. The analytical results are compared with the test results. Even if beam that filled up light weight concrete was calculated moment-curvature relationship easily analytically and could know that analytical results estimates as well agreed with the test results in case filled up normal concrete. In addition, the efficiency and applicabilities of the proposed moment curvature relationship algorithm are verified through conventional experimental results.

A Study on the Early Strength Prediction of Lightweight Polymer Mortars by the Maturity Method (적산온도법에 의한 경량 폴리머 모르터의 초기강도 예측에 관한 연구)

  • 이윤수;대빈가언;연규석
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.191-202
    • /
    • 1998
  • The maturity method in which the strength increase of cement concrete is expressed as a function of an intergral of the curing period and temperature of the concrete has often been applied to its strength prediction. For the purpose of the application of the maturity method to the compressive strength prediction for lightweight polymer mortars using an unsaturated polyester resin as a binder, the lightweight polymer mortars with various catalyst and accelerator contents, are prepared. tested for compressive strength, and the datum temperatures for the maturity equations are estimated. The maturity is calculated by using the maturity equations with the estimated datum temperature. The compressive strengths of the lighweight polymer mortars are predicted from the maturity-compressive strength relationships.

Fundamental Properties of Lightweight Concrete with Dry Bottom Ash as Fine Aggregate and Burned Artificial Lightweight Aggregate as Coarse Aggregate (건식 바텀애시 경량 잔골재와 소성 인공경량 굵은골재를 사용한 콘크리트의 기초 특성)

  • Choi, Hong-Beom;Kim, Jin-Man
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.267-274
    • /
    • 2018
  • Though the wet bottom ash has been used as a type of lightweight aggregate, dry bottom ash, new type bottom ash from coal combustion power plant, has scarcely researched. It is excellent lightweight aggregate in the view point of construction material. This study is performed to check the applicability of dry bottom ash as a fine aggregate in lightweight aggregate concrete, by analyzing various properties of fresh and hardened concrete. We get results that the slump of concrete is within the target range at less than 75% replacement rate of dry bottom ash, the air content is not affected by the replacement rate of dry bottom ash, the bleeding capacity is less than $0.025cm^3/cm^2$ at 75% under of the replacement rate of dry bottom ash, and the compressive strength of concrete show 90% or more comparing the base mix while initial strength development is a little low. Oven dry unit weight of concrete is reduced by 8.9% when replaced 100% dry bottom ash, and dry shrinkage tends to decrease depending on increase of replacement rate of dry bottom ash. Modulus of elasticity of concrete shows no decease at 50% over of the replacement rate of dry bottom ash, while modulus of elasticity of concrete decreases when the replacement rate increases further. The dry bottom ash, when used as a fine aggregate in lightweight concrete, can be used effectively without any deterioration in quality.

Properties of Concrete Panel Made by Light Weight Aggregates (인공경량골재로 제조된 콘크리트 패널의 물성)

  • 엄태호;김유택
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.3
    • /
    • pp.221-228
    • /
    • 2004
  • Basic properties of artificial lightweight aggregate by using waste dusts and strength properties of LWA concrete were studied. Bulk specific gravity and water absorption of artificial lightweight aggregates varied from 1.4 to 1.7 and 13 to 16%, respectively. Crushing ratio of artificial lightweight aggregate was above 10% higher than that of crushed stone or gravel. As a result of TCLP leaching test, the leaching amount of tested heavy metal element was below the leaching standard of hazardous material. Slump, compressive strength and stress-strain properties of LWA concrete made of artificial lightweight aggregate were tested. Concrete samples derived from LWA substitution ratio of 30 vol% and W/C ratio of 45 wt% showed the best properties overall. Thermal insulation and sound insulation characteristics of light weight concrete panel with the optimum concrete proportion were tested. Average overall heat transmission of 3.293W/㎡$^{\circ}C$ was observed. It was higher by about 15% than those of normal concrete made by crushed stone. Sound transmission loss of 50.9 ㏈ in frequency of 500 ㎐ was observed. It was higher by about 13% than standard transmission loss.

An Experimental Study on the Pore Structure and Thermal Properties of Lightweight Foamed Concrete by Foaming Agent Type (기포제 종류에 따른 경량기포콘크리트의 기포구조 및 열적특성에 관한 실험적 연구)

  • Kim, Jin-Man;Choi, Hun-Gug;Park, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.63-73
    • /
    • 2009
  • Recently, the use of lightweight panels in building structures has been increasing. Of the various lightweight panel types, styrofoam sandwich panels are inexpensive and are excellent in terms of their insulation capacity and their constructability. However, sandwich panels that include organic material are quite vulnerable to fire, and thus can numerous casualties in the event of a fire due to the lack of time to vacate and their emission of poisonous gas. On the other hand, lightweight foamed concrete is excellent, both in terms of its insulation ability and its fire resistance, due to its Inner pores. The properties of lightweight concrete is influenced by foaming agent type. Accordingly, this study investigates the insulation properties by foaming agent type, to evaluate the possibility of using light-weight foamed concrete instead of styrene foam. Our research found thatnon-heating zone temperature of lightweight foamed concrete using AP (Aluminum Powder) and FP (animal protein foaming agent) are lower than that of light-weight foamed concrete using AES (alkyl ether lactic acid ester). Lightweight foamed concrete using AES and FP satisfied fire performance requirements of two hours at a foam ratio 50, 100. Lightweight foamed concrete using AP satisfied fire performance requirements of two hours at AP ratio 0.1, 0.15. The insulation properties were better in closed pore foamed concrete by made AP, FP than with open pore foamed concrete made using AES.