• Title/Summary/Keyword: 경량 콘크리트

Search Result 571, Processing Time 0.028 seconds

A Study on Fabrication and Characterization of Inorganic Insulation Material by Hydrothermal Synthesis Method (2) (수열합성법을 이용한 무기계 단열소재 제조방법 및 특성에 관한 연구 (2))

  • Seo, Sung-Kwan;Chu, Yong-Sik;Lee, Jong-Kyu;Song, Hun;Park, Jae-Wan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.225-232
    • /
    • 2013
  • The inorganic insulating material was fabricated with quartzite, ordinary portland cement(OPC), lime, anhydrous gypsum and foaming agent by hydrothermal reaction. The inorganic insulating material was fabricated by using autoclave chamber under high-temperature and high-pressure. The inorganic insulating material is a porous lightweight concrete. Because of its porous structure, properties of inorganic insulating material were light-weight and high-heat insulation property. Properties of fabricated inorganic insulating material were $0.26g/cm^3$ in specific gravity, 0.4MPa in compressive strength and 0.064W/mK in thermal conductivity. In this study, the inorganic insulating material was fabricated and analyzed at different size of quartzite/OPC, various foaming reagent and functional additives to improve the properties. Consequently, polydimethylsiloxane can improve density and thermal conductivity. Especially, polydimethylsiloxane showed excellent improvement in compressive strength.

Evaluation of Vibration and Structural Performance of an Innovative Sliding Step Steel Stair Using Full-Scale Mock-up Test (실물대 목업실험에 의한 슬라이딩스텝 철골계단의 진동 및 구조성능 평가)

  • Kim, Sung Yong;Lee, Cheol Ho;Kim, Na Eun;Cho, Sung Sang;Chung, Woon Ok
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.511-522
    • /
    • 2014
  • In this study, an innovative steel stair system is presented which enables rapid erection and high quality control in both residential and office building construction. This system features two lightweight steel stringers of box shape, bolted connections easy to absorb construction tolerance, and stair steps movable transversely (or sliding steps) such that the work space needed for concrete stairway wall could be easily provided. In this type of stairway system, other than providing robust connecting details, ensuring vibration performance is especially important since this system may be vibration-sensitive due to lightweight nature and/or probable low damping. To tackle these issues, a series of full-scale mock-up tests were conducted by using box-shape stringer members with or without concrete-fill. The connection system was shown to be sufficiently stiff and strong, or it remained elastic even under the 160% of service load level. Among the seven stringer alternatives, five exhibited satisfactory vibration performance according to the related North American and European acceptance criteria.

Evaluation of Bond Strength in FRP Hybrid Bar Affected by Freezing/thawing Test and UV Rays (동결융해 및 UV 폭로시험을 거친 FRP Hybrid Bar의 인발거동특성 평가)

  • Park, Jae-Sung;Yoon, Yong-Sik;Park, Ki-Tae;Kwon, Sung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.1
    • /
    • pp.53-58
    • /
    • 2017
  • FRP Hybrid Bar, composed of an embedded steel and the coated composites with epoxy and glass fiber, is an effective construction material with tension-hardening performance and lightweight. The epoxy exposed to UV(Ultra Violet Rays) and FT(Freezing and Thawing) action easily shows a surface deterioration, which can cause degradation of bonding strength between inside-steel and outside-concrete. In the present work, surface inspection for 3 different samples of normal steel, FRP Hybrid Bar before UV, and FRP Hybrid Bar after UV test was performed, then concrete samples with 3 reinforcement types were prepared for accelerated FT test. Through visual inspection on 3 typed reinforcement, no significant deterioration like chalking was evaluated. The results from FT test to 120 and 180 cycles showed FRP Hybrid Bar exposed to UV test has higher bonding strength than normal steel by 106.3% due to enlarged bond area by silica coating. The 3 cases showed a similar bond strength tendency with increasing FT cycles, however a relatively big deviations of bond strength were evaluated in FRP Hybrid Bar after UV test due to loss of silica coating.

Structural Performance of One-way Void Plywood Slab System with form work Pane (거푸집 패널이 부착된 1방향 중공슬래브의 구조 성능)

  • Hur, Moo-Won;Chae, Kyoung-Hun;Hwang, Kyu-Seok;Yoon, Sung-Ho;Park, Tae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.7-15
    • /
    • 2021
  • In this study, we developed Void Plywood Slab (VPS) that improved the shape of existing hollow materials. Its performance was evaluated through one-way flexural and one-way shear tests using the developed VPS. As a result of the one-way flexural performance tests of VPS, the yield load value for FPS series(longitudinal direction specimens with hollow materials) was approximately 97.5% compared to FPS-00(without hollow materials) specimen. The tests showed that the yield load was not much different. In addition, FNS series(transverse direction specimens with hollow materials) also represented about 97% of FPS-00 specimen. The one-way flexural performance was shown to have little impact from void materials. Therefore, it is confirmed that the presented system is applicable to the VPS to the slab design. The results of the one-way shear performance tests of VPS showed that it was about 92% compared to the SS-00(without hollow materials) specimen. These results were somewhat insufficient for the SS-00 specimen. Shear strength equation is expressed as the sum of shear force by concrete and shear force by reinforcement. However, in the case of void slab, it is believed that the concrete section has been deleted by the void material. However, the strength of the structure applied to the shear design, as with the flexural design, is also applied to the design based on the yield load value.

An Experimental Study on Concrete Bond Behavior According to Grid Spacing of CFRP Grid Reinforcement (격자형 CFRP 보강재의 격자간격에 따른 콘크리트 부착거동에 대한 실험적 연구)

  • Noh, Chi-Hoon;Jang, Nag-Seop;Oh, Hongseob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.73-81
    • /
    • 2022
  • Recently, as the service life of structures increased, the load-carrying capacity of deteriorated reinforced concrete, where corrosion of reinforcing bars occurs due to various causes, is frequently decreased. In order to address this problem, many studies on the bond characteristic of FRP (Fiber Reinforced Polymer) bars with corrosion resistance, light weight and high tensile strength have been conducted, however there are not many studies on the bond characteristic of grid-typed CFRP embedded in concrete. Therefore, in order to evaluate the bond characteristics of grid-typed CFRP and its usability as a substitute for steel rebar, a pull-out test is performed using the longitudinal bond length and transverse grid length of the grid-typed CFRP as variables. Through the pull-out test, the bond load-slip curve of the grid-typed CFRP is derived, and the bond behavior is analyzed. The total bond load equation is proposed as the sum of the bond force of the longitudinal bond length and the shear force of the grid in the transverse direction. Also, expressing the area of the bond load-slip curve as total work, the change in dissipated energy with respect to the slip is analyzed to examine the effect of the tranverse grid on the bond force.

Characteristics of Lightweight Aggregate Concrete according to Freezing and Thawing Resistance Test Methods (동결융해 저항성 시험방법에 따른 경량골재 콘크리트의 특성)

  • Kim, Se-Hwan;Kim, Sang-Heon;Lee, Soo-Hyung;Jeon, Hyun-Kyu;Seo, Chee-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.3
    • /
    • pp.202-208
    • /
    • 2013
  • The method used to test lightweight aggregate concrete for its resistance to freezing and thawing is different in each country. In Korea, the method of KS F 2456 on normal concrete is adopted for lightweight aggregate concrete, while the testing method of ASTM C 330 lightweight aggregates for structural concrete is used in the majority of overseas countries. In this study, we identified differences between KS F 2456 and ASTM C 330 in terms of the testing method for freezing and thawing resistance, and we studied the influence of this on the freezing and thawing resistance of lightweight aggregate concrete. The results of this study were as follows: Blocked lightweight aggregates had a slight collapse of shape and lost weight by repeated freezing and thawing, but unblocked lightweight aggregates were badly collapsed. And while the freezing and thawing resistance tests of normal concrete showed similar results despite the difference in the KS and ASTM testing method, the results for lightweight aggregate concrete were very different. So the KS test method shows evaluation results that are much lower than the ASTM test method.

A Study for Physical Properties of ALC using different Quartzite (규석 종류에 따른 ALC 물성 연구)

  • Chu, Yong-Sik;Seo, Sung-Kwan;Im, Du-Hyuk;Song, Hun;Lee, Jong-Kyu;Lee, Seung-Ho
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.89-94
    • /
    • 2012
  • ALC was fabricated using cement, lime and quartzite by hydrothermal reaction. The kind of quartzite was reviewed for ALC properties and returned slurry was recycled in this study. Munkyung and Kumpyung quartzite was used and quartzite powder was experimented. The major mineral phase of Munkyung quartzite was quartz and muscovite crystal but that of Kumpyung was quartz. It was certain that crystallinity of Kumpyung quartzite was superior to Munkyung quartzite. Compressive strength and A-number of ALC with Kumpyung quartzite was higher than that of ALC with Munkyung quartzite under similar specific gravity. These results was resulted from major mineral phase, crystallinity and minor components of quartzite.

  • PDF

A Fundamental Study on Properties of Method of Packaged Dry Combined Materials for Concrete -based on using high absorption aggregate- (건조된 재료를 혼합 포장한 콘크리트의 특성에 관한 기초적 연구 -흡수율이 높은 골재 사용 중심으로 -)

  • Han, Da-Hee;Kim, Kwan-Ki;Jung, Sang-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.1 s.23
    • /
    • pp.115-121
    • /
    • 2007
  • Ordinary concrete uses aggregate sufficiently soaked with water, and is weighed, mixed with other materials and placed in accord with performances required in the construction field. Recently special concrete with high fluidity and durability is required but it is difficult to use top-quality concrete due to lack of high-quality aggregate, delayed transportation because of traffic jam, etc. In addition, sometimes the use of a remicon is inevitable just for small-sized concrete constructions or it is difficult for a remicon to reach remote construction places such as mountainous areas. To solve these problems, this study attempted to pack concrete materials. In other words, it is to instantize concrete. This study dried aggregate, a material of concrete, and compared the change of absorption phase of the aggregate in water and in paste in order to examine the effect of the dryness of aggregate on its absorption rate and, based on the absorption rate, decided water addition ratio necessary for the reduction of unit quantity caused by the use of dry aggregate in designing concrete mixture, and analyzed the properties of unhardened concrete according to water addition ratio in manufacturing concrete using aggregate in the state of absolute dryness and in the state of surface dryness.

Stability Analysis of Reinforced Retaining Wall with Steel Supported Face (강재지주 전면판 보강토 옹벽의 안정성 평가)

  • Kim, Ki Il;Kim, Byoung Il;Lee, Yeong Saeng;Lee, Soon Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2C
    • /
    • pp.75-82
    • /
    • 2011
  • Recently, a new reinforced retaining wall with light steel support face has been developed. In this study, full size in-situ test is carried out to investigate the stability of the new reinforced retaining wall. The lateral displacement of wall, lateral earth pressure, and settlement of the reinforced retaining wall are measured in the full size test. And numerical analysis by 3-D finite element method is also carried out to compare the test results with those of the analysis. From the full size in-situ test, the maximum lateral displacement of wall is 46mm(0.009H) and the maximum settlement is 21.5mm. And comparing these values with those of numerical analysis, it is confirmed that the new reinforced retaining wall with light steel support face is stable and applicable.

The Characteristic of Physical properties and Shrinkage of Nano-filament according to the Textured Conditions (사가공 조건에 따른 nano-filament의 물성 및 수축특성)

  • Kang, Ji-Man;Cho, Dae-Hyun;Lee, Jun-Hee;Choi, Jong-Duk
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.92-92
    • /
    • 2012
  • 나노필라멘트 섬유는 직편물 등으로 구조/용도 다양화 가능하다. 나노필라멘트 섬유는 소재특유의 닦음성, 흡착성, 고밀도 특성 등을 활용하여 직편물의 형태로 다양한 용도 개발이 가능하며, 나노기술을 접목시킨 새로운 기능성과 고성능 섬유 소재 개발을 통한 자동차 분야의 개발 트랜드인 고급화, 경량화, 고성능화 추진을 위해 연료전지, 신슐레이터, 고성능 필터, 시트나 도어트림, 헤드라인과 같은 인테리어류와 전자 분야의 제조원가 절감, 공정 단순화를 위해 프린터 토너, 하드디스크 연마제, 다용도 No Dust Cleaner 등의 개발, 의료/바이오 분야의 혈액필터, 수술용 보호제, 창상억제제(유착 방지막), 항균마스크, 의료용 약물전달 시스템 및 환경 분야의 정수/공기 정화 시스템, 건축 토목용 보강제, 고(高)인성 콘크리트, 폐수처리용 슬러리 담체(Matrix) 등 다양한 분야로 용도 개발이 가능하다. 본 연구는 나노필라멘트의 다양한 분야로의 용도 개발 적용의 기초연구로서, 부직포 상으로 얻어지는 나노섬유 제조기술의 단점인 직경의 불균일, 물리적 특성의 한계와 필라멘트가 아닌 단섬유로 인해 발생하는 용도 및 상품 개발에의 제한성을 개선하기 위하여 연속적으로 필라멘트를 생산가능한 해도형 복합방사 방법을 도입하여 개발한 장섬유 필라멘트 형태의 해도형 나노 섬유 소재를 활용하는 것으로 방사된 SDY 형태의 나노필라멘트 섬유를 제직상에서의 작업성 용이 및 직물의 벌키성 증대와 Crimp성을 향상 시켜 터치감 및 후가공에 용이할 수 있도록 DTY를 제조함에 있어 기존 일반 POY사에서의 DTY공정과는 달리 소재의 특성 즉, 해도사의 해성분 및 도성분의 후공정을 감안하여 최적의 Crimp는 발현하되 단면의 형상을 유지할 수 있는 다양한 사가공 조건을 설정 하고 이에 따라 가공사를 생산하여 공정조건에 따른 가공사의 물성 및 수축특성을 비교 분석 하여 염색 및 후가공시 소재의 물성 및 수축특성이 미치는 영향성을 살펴보고자 하였다.

  • PDF