• Title/Summary/Keyword: 경도 근시

Search Result 27, Processing Time 0.022 seconds

Accommodative response measurement using both eyes open-view autorefractometer (양안 개방형 자동굴절검사기를 이용한 조절반응량 검사)

  • Shim, Hyun-Seog;Lee, Seong-Wook;Shim, Moon-Sik;Choi, Sun-Mi;Jang, Seong-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.323-328
    • /
    • 2005
  • The purpose of this research was to measurement real Accommodative response amount using both eyes open-view autorefractometer. Compared each Accommodative response amount to distinction of sex, age, kind of ametropia, amount of astigmatism and kind of astigmatism. The subjects were 153 healthy men and women between the age of 20~80 years. Age comparison, 20 years 1.15D, 30 years 1.23D and above 40 years 0.60D. It was no difference between 20 to 30 years old. But, is decrescent remarkably above 40 years old. Ametropia examined by hypermetropia 1.78D, emmetropia 1.51D, low myopia 1.08D, middle myopia 0.72D, high myopia 0.643D. Myopia increased, Accommodative response amount was expose that decrease. Astigmatism examined by non astigmatism 1.13D, low astigmatism 1.12D, middle astigmatism 0.85D, high astigmatism 0.83D. Astigmatism increased, Accommodative response amount was expose that decrease. The sex and astigmatism type difference appeared with the fact that the result is not a difference.

  • PDF

Comparison of Clinical Results of Excimer Laser Correction of Myopia and Compound Myopic Astigmatism Using VISX 20/20B $VisionKey^{TM}$ (VISX 20/20B $VisionKey^{TM}$ 엑시머레이저의 version 4.01 software를 이용한 근시교정술 및 근시성난시교정술의 임상성적 비교)

  • Lee, Sang-Bumm;Bae, Sang-Bok
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.1
    • /
    • pp.55-65
    • /
    • 2000
  • Purpose: To compare the efficacy, predictability, stability and safety of excimer laser photorefracive keratectomy(PRK) for myopia and photoastigmatic refractive keratectomy(PARK) for compound myopic astigmatism. Methods: Two-hundred and three eyes(l18 eyes < -7D spherical equivalent, 85 eyes ${\geq}$ -7D spherical equivalent) received excimer laser correction for compound myopic astigmatism and 152 eyes(116 eyes < -7D, 36 eyes ${\geq}$ -7D) for simple myopia. A VISX 20/20B $VisionKey^{TM}$ excimer laser was used to perform either PARK or PRK. Visual acuity with and without correction, refraction, IOP, corneal haze, and topography were evaluated at 1, 3, 6, and 12 months postoperatively. All patients were followed up for more than 12 months. Results: Postoperative refraction were generally stable after 3 months without significant early overcorrection. At 12 months, 110(94.8%) eyes that underwent PRK and 104(88.1%) eyes that underwent PARK achieved UCVA of 20/30 or better in the group who had lower than -7D correction. For eyes treated with -7D or more, these figures were 31(86.1%) eyes after PRK and 57(67.1%) eyes after PARK. The incidences of within 1D of plano refraction at 1 year follow-up were 97.4% after PRK and 93.2% after PARK in the group who had lower than -7D correction. For eyes treated with -7D or more, these figures were 80.6% after PRK and 70.6% after PARK. Conclusions Myopia with or without astigmatism was successfully treated in most of the eyes using PRK or PARK with VISX 20/20B $VisionKey^{TM}$ excimer laser. The predictability and stability of the postoperative refraction during the first 12 months seem to be quite reliable. Further improvement of excimer laser system and software should increase the clinical outcomes and safety of refractive procedures.

  • PDF

Time-dependent Changes of Ocular Functions after Alcohol Ingestion (알코올 섭취 후 시간경과에 따른 시 기능의 변화)

  • Kim, Sang-Yoeb;Moon, Byeong-Yeon;Lee, Sun Haeng;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.133-138
    • /
    • 2009
  • Purpose: This study was designed to investigate the changes of vision and ocular functions induced by increase of blood alcohol level. Methods: Blood alcohol level, vision, refractive errors, near point convergence, heterophoria, and relative convergence were measured at 1 h, 4 h, and 24 h after acute alcohol ingestion of 0.7 g per kg body weight. Results: At 1 h after alcohol ingestion, myopization and ocular functions which measured near point convergence, positive and negative convergences, and degree of heterophoria remarkedly worked a changes accompanied with the maximum value of blood alcohol level. But at 24 h after that, all of ocular functions were recovered to degree of 90~99% compared with non-alcoholic normal conditions. Conclusions: As the increase of blood alcohol level is able to induce the significant changes of visual acuity and ocular functions, opticians have to understand thoroughly the patient's conditions by alcohol ingestion before refractive test and ocular examinations.

  • PDF

Contrast Sensitivity and Glare with Spherical and Toric Soft Contact Lenses in Low-astigmatic Eyes (구면과 토릭 소프트 렌즈로 교정한 약도 난시안의 대비감도와 눈부심)

  • Lee, Min-Ah;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the visual performance by contrast sensitivity (CS) and disability glare (DG) in low astigmatic eyes corrected with toric soft lenses and other optical corrections. Methods: Twenty university students with myopia (-1.00 to -6.50D Sph. with astigmatism up to 1.50 cyl) were enrolled and corrected by five different methods: 1) soft toric lenses; 2) spherical soft contact lenses; 3) RGP lenses; 4) best spectacle corrected visual acuity; 5) spherical equivalent spectacles. All subjects had corrected vision acuity of 20/20 or better. Contrast sensitivity and disability glare were measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView Functional Vision Analysis software at photopic or mesopic conditions with glare. Results: At photopic condition, best corrected spectacle wearers had the highest monocular contrast sensitivity at all spatial frequency followed by soft toric lenses, RGP lenses, spherical equivalent spectacles, and spherical soft contact lenses. However, all of them were in normal contrast sensitivity value at photopic condition. At mesopic condition with glare, toric soft lenses were the highest and followed by RGP lenses, spherical equivalent spectacles, best spectacle corrected visual acuity and spherical soft contact lenses. It was observed that spherical soft contact lens wearers demonstrated lower range than normal contrast sensitivity value at mesopic condition with glare. Conclusion: Toric soft lenses gave better visual performance than spherical soft lenses in low astigmatic eyes. Subjects requiring the use of contact lenses under mesophic conditions could benefit from toric soft lenses.

  • PDF

A Comparative Analysis of increased along with the age presbyopic additions in city and island villages (도시와 섬마을 노안의 연령에 따른 근용 가입도의 비교 관찰)

  • Kim, In-Suk;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.61-65
    • /
    • 2002
  • This study examines how the average presbyopic additions and eye refraction state of old ages in city may be different to that island. There were 677 of the old who were 50 or over 90 in the sample. The visual acuity test was done by objective and subjective methods and used for near-chart program. The far-point refraction state and power of the additions lens results were as follows ; 1. Of far-point refraction state in city peoples; male: emmetropia 10%, myopia 17%, hyperopia 19%, mixed astigmatism 38%, etc. 16% female : emmetropia 20%, myopia 20%, hyperopia 20%, mixed astigmatism 27%, etc. 13% 2. Of far-point refraction state in island villages ; male : emmetropia 13%, myopia 17%, hyperopia 22%, mixed astigmatism 40%, etc. 8% female : emmetropia 7%, myopia 13%, hyperopia 26%, mixed astigmatism 44%, etc. 10% 3. Average presbyopic additions states has been presented no discrimination ; male: 50 to 60 : +1.25 or +1.50D, 61 to 65 : +1.75 or + 2.00D, 66 to 70 : +2.25 or +2.50D 71 to 75 : +2.75 or +3.00D, 76 to 80 : +3.25 or +3.50D, over81 : +3.75D female : 50 to 60 : +1.25 or + 1.50D, 61 to 65 : +1.75 or + 2.00D, 66 to 70 : +2.25 or +2.50D 71 to 75 : +2.25 or + 2.50D, 76 to 80 : +2.75 or +3.00D, over81 : +2.75 or +3.00D 4. Under the condition of wearing lens, the average working time was 1 or 2 hour but some people used over 5 hours. 5. Generally, it has been investigated the old ages peoples has ocular diseases and cataract was the most common.

  • PDF

The factors influencing the quantity of Phoria: I. A study of effects to the quantity of Phoria by the refractive error and the conformity to the optical center and the pupillary center (사위량에 영향을 미치는 요인: I. 굴절이상, 동공중심과 광학중심의 일치에 따른 연구)

  • Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.361-370
    • /
    • 2004
  • The purpose of this study was to evaluate the outcome and Factors that influence the quantity of Phoria in the low correction and perfect correction. Also the coincidence with the opticenter and the pupillary distance was a principal factor that influence the quantity of Phoria. Thereupon, this study is attributed to promote the perfect Phoria test. The subjects for this study were 120 persons(240 eye) in myopic refractive errors. ISP/WIN program was used for the data analysis. The collected data was analyzed by descriptive statistics and Spearman's correlation coefficient. The results of this study were as follows: 1. The prism pattern was difference between low correction and perfect correction in the Phoria test. The proportion of orthophoria was changed from 10.0% to 12.5%, exophoria was changed from 67.5% to 62.5%, and esophoria was changed from 22.0% to 32.5%, respectively. 2. The average of optical center distance and pupillary distance were 31.70mm and 31.49 mm, respectively. 3. Among the 120 myopic glasses wearers, the distance between optical centers was coincided with the pupillary distance in 37.5%, and discrepant in 62.5%. 4. For the patients who were coincided with the pupillary distance, the proportion of exophoria decreased 53.33%, esophoria increased 20.0%. 5. For the changing of the quantity of Phoria in the low correction, the degree of exophoria decreased 1.11 prism diopters in the perfect correction, esophoria increased 0.39 prism diopters.

  • PDF

Studies on the Characters of Green-stem Varient Ginseng Plant (청경종의 제형질 특성에 관하여)

  • 천성룡;김경태
    • Journal of Ginseng Research
    • /
    • v.13 no.2
    • /
    • pp.153-157
    • /
    • 1989
  • The characteristics of the areal parts, photosynthetic and respiration rates and stem color were examined in 1- to 5-year-old Green-stem, Violet-stem and Yellow-berry variant ginseng (Panax ginseng C.A. Meyer). The top characteristics, photosynthetic and respiration rates were not significantly different among the three variants. Selfed progency of the Green-stems variant plant produced only green stems, while the others produced green and violet stem in the seedling stage. These results showed that most of the top characteristics of the Green-stem variant were similar those of the Violet-stem and Yellow-berry variants with age.

  • PDF

The Clinical Tests for Treatment Improvement Comparison in Myopia between Eye Acupuncture Massage Machine (NURIEYE-1) and Acupuncture (경도근시(가성근시 포함) 환자에 있어 눈 경혈 마사지기와 침치료간의 증상개선 효과 비교를 위한 임상시험(단일기관, 무작위 배정))

  • Kim, Mi-Bo;Kim, Kyu-Kon;Hong, Sang-Hun;Ko, Woo-Shin;Yoon, Hwa-Jung
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.22 no.3
    • /
    • pp.80-94
    • /
    • 2009
  • Objective : The purpose of this clinical research is the investigation of the effects between acupuncture group(control group) and NURIEYE-1 group (experimental group) in myopia Methods : Comparison clinical study was conducted with the randomly arranged 32 patients for acupuncture group(control group) and NURIEYE-1 group(experimental group). For effectiveness evaluation, eye sight test, MQOL and DITI were tested three times with visits for every 4 weeks. With SAS, Statistical analysis was performed by using paired t-test and two sample t-test. Statistical significance was achieved with less than 5% probability (p<0.05). Result : 1. There was no significant effect from the eye sight comparison between the two group. We had improved results in average with MQOL, however, there was no statistical significance. Though there was also no significant result with DITI average comparison between two group, we witnessed significant effect in some part of MQOL. 2. Nevertheless Periodical comparison test showed weak significance with eye sight and DITI, significant effect was found in some part of MQOL. 3. With periodical comparison tests, there were significant effects in eye sight, MQOL and DITI with the experimental groups and control groups, respectively. Conclusion : There was no significant eye sight improvement. However, with acupuncture point stimulation, we think there are some positive effects for the relaxation of excessive stress in eyes.

  • PDF

Design and Implementation of the Quantity Surveying and Shop Drawing System for Structures (BIM 기반 골조 물량산출 및 도면생성 모듈의 설계와 구현)

  • Lee, Byung-Kwon;Kim, Chee-Kyeong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.132-135
    • /
    • 2011
  • 최근 설계 단계에서 설계품질 향상과 시공 단계에서 비용 절감을 효과를 기대하며 3차원 BIM 관련 기술에 대한 관심이 높아가고 있으며, 또한 부분적으로 기술 도입 효과가 나타나고 있다. BIM 기술은 크게 BIM 도구를 활용하여 설계정보를 디지털화하는 모델링 단계 기술과 BIM 모델로부터 설계 정보를 추출하여 업무 진행에 필요한 형태로 가공, 변환하는 정보 활용 기술로 구분하여 생각할 수 있다. BIM 기술에 대한 근자의 높은 관심에도 불구하고 실제 현장에 적용되어 가시적인 성과를 내는 데에 한계를 보이고 있는 이유 중 하나로 후자의 정보 추출 및 활용 기술의 범위와 완성도의 한계를 들 수 있다. 즉 많은 노력을 통하여 BIM 모델을 구축하더라도 이를 기반으로 물량산출, 도면 생성 등 가장 기본적인 업무조차도 현장에서 바로 사용할 수 있는 수준의 기능이 제공되고 있지 않다. 본 연구에서는 건축 골조를 대상으로 3차원 골조 모델을 이용하여 골조 물량, 특히 정확한 물량산출이 상대적으로 어려운 철근에 대하여 철근의 이음, 정착 등이 고려된 실행물량을 산출할 수 있는 시스템을 설계하고 구현하였다. 또한 3차원 모델을 기반으로 철근 배근시공도와 가공일람표를 관련 기준에 따라 정확히 자동 작성함으로써 골조공사가 효율적으로 수행되고, 특히 정확한 이음 및 정착과 가공 계획을 통하여 철근 손실율을 최소화함이 기대된다. 본 논문에서는 이러한 BIM 기반 골조 물량산출 및 도면생성 시스템과 관련하여 주요 시스템 설계 내용과 구현 결과에 대하여 기술한다.

  • PDF

The Age-specific Change of Refraction(D) Power and Relative Risks of Refractive Errors (연령에 따른 굴절력 변화와 굴절이상의 상대 위험도)

  • Lee, Eun-Hee;Lee, Sang-Yoon;Lee, Hee-Jung;Cho, Sung-Il;Paek, Domyung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.1-5
    • /
    • 2007
  • This is a succeeding article of J. Korean Optalmic Optics Society vol. 11(2) pp. 121-129(2006) [Research about the distribution of refractive errors in distinction of gender and at age of Kyonggi province's partial area]. The former article showed age-specific distribution of myopia, hyperopia and astigmatism which generally appears in refractive errors. This paper aimed to investigate the change of refractive power and prevalence of refractive errors by age. Total 928 subjects were sampled and their refractive errors were determined using auto refractometer. As the results, change of refractive power of subjects appeared at the age about 40, and suddenly reduced over 46 years resulting in (+)refractive power at their fifties. Relative risks of refractive errors of myopia increased in younger subjects but the risks decreased in older subjects (over 46 years). On the other hand, the risks of hyperopia decreased as the age of subjects increase, but could increase to 0.24 (95% CI: 0.07-0.88) after 36 years. This results showed that presbyopia might progress more early when people were before 40 years.

  • PDF