• Title/Summary/Keyword: 경골골절

Search Result 113, Processing Time 0.038 seconds

Use of Minimally Invasive Plate Osteosynthesis for Tibial Diaphyseal Fracture in Three Dogs (경골 골간 골절에서의 최소 침습적 금속판 고정술의 이용 3례)

  • Heo, Su-Young;Lee, Ki-Chang;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.29 no.4
    • /
    • pp.339-343
    • /
    • 2012
  • Three dogs were presented with diaphyseal fracture of the tibia following separate motor vehicle accidents. On physical and orthopedic examinations, the dogs were noted to have soft-tissue swelling and a closed fracture in these tibia sites. Radiographs revealed a simple, short oblique fracture (case 1), a comminuted, spiral fracture (case 2), and a simple, spiral fracture (case 3) in tibia. Minimally invasive percutaneous plate osteosynthesis (MIPO) using a veterinary cuttable plate or locking plate was applied for the treatment of these fractures. The surgery was successful, and the fractures healed without any complications by 7 weeks (case 1), 10 weeks (case 2) and 8 weeks (case 3) after surgery. Our patients showed fast bone healing times and early weight-bearing during the treatment of their tibia fractures. Therefore, MIPO was a useful procedure for diaphyseal fracture of the tibia in veterinary orthopedics.

Effects of Non-Invasive Constant Microcurrent Stimulation on Expression of BMP-4 After Tibia Fracture in Rabbits (비침습식 미세전류자극이 토끼 경골의 골절 후 BMP-4 발현에 미치는 영향)

  • Cho, mi-suk
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1124-1129
    • /
    • 2009
  • This study aims to examine the effects of non-invasive constant microcurrent stimulation on expression of Bone Morphogenetic Protein(BMP) 4 after tibia fracture in rabbits. Twenty four rabbits with tibia fracture were randomly divided into control and experimental groups. Each group was divided into four subgroups, based on the duration of the experiment (3, 7, 14, 28 days). The experimental groups received a constant microcurrent stimulation of $20{\sim}25{\mu}A$ intensity with surface Ag-AgCl electrode (diameter 1cm, Biopac, U.S.A.) for 24 hours a day. Cathode of the microcurrent stimulator located on the tibia directly, anode of it did on the gastrocnemius muscle. Rabbits were sacrificed on each of the postoperative days 3, 7, 14, 28. To investigate how non- invasive constant microcurrent stimulation affects bone healing, immunohistochemical analysis of BMP-4 was performed at each point. After evaluation, the test results are as follows: Comparisons of immunohistochemical observation of BMP-4 in 7 days after tibial fracture show that there was shown to be a moderate positive reaction (++) on concentric circles of Harversian system andt he interstitial lamella in the control group, while there was a very strong positive reaction (++++) on concentric circles of Harversian system and interstitial lamellain the experimental group. These results suggest that applying non-invasive constant microcurrent stimulation on fractured bone is helpful to bone healing.

  • PDF

Result in Tibial Stress Fracture Treatment in a Elite Soccer Player -A Case Report- (축구 선수에서 발생한 경골 피로 골절 치료에 대한 결과 -1예 보고-)

  • Lee, Kyung-Tai;Kim, Ki-Chun;Park, Young-Uk;Kim, Jun-Beom
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.9 no.2
    • /
    • pp.114-120
    • /
    • 2010
  • Anterior tibial diaphyseal stress fracture have a propensity for delayed union or nonunion and have risk of complete fracture after minor trauma. So, careful evaluation and optimal management are mandatory to succeed in treatment. It is also important to decide the point of time of return to full activity. We report experience of treatment for complete fracture of the delayed union of anterior tibial diaphyseal stress fracture as an athletic injury.

  • PDF

Nonunion of Tibial Eminence Fracture in Child - 2 cases Report - (소아 경골 극 골절의 불유합 - 2예 보고 -)

  • Hur, Yoon-Moo;Chung, Whan-Yong;Kim, Sang-Bum;Kim, Sung-Hun;Rhu, Seung-Reol
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.192-198
    • /
    • 2006
  • The general consensus is that tibial eminence fractures have an excellent prognosis. But symptomatic nonunions requiring reduction and grafting have been reported. This report presents two cases of nonunion after tibial eminence fracture in eight years old boys which were treated with arthroscopy-guided reattachment and internal fixation and obtained good outcome.

  • PDF

Radiographic Changes of Bilateral Partial Avulsion Fracture of Tibial Tuberosity in a Dog (개에서 발생한 양측성 경골조면 부분 견열골절의 방사선학적 변화)

  • Keh, Seo-Yeon;Choi, Mi-Hyun;Lee, Nam-Soon;Jang, Jae-Young;Lee, Hae-Keong;Kim, Hyun-Wook;Yoon, Junghee
    • Journal of Veterinary Clinics
    • /
    • v.30 no.2
    • /
    • pp.134-137
    • /
    • 2013
  • A 4-month-old intact male Jindo dog was presented for left hindlimb lameness. On radiographs, a small mineralized piece was identified beneath the apophysis of tibia with no or minimal displacement of apophysis bilaterally. Subsequently, the cranioproximal bony aspect of the tibia changed radiolucent to radiopaque. The left side recovered after surgical management, but the right side was self-limited with conservative management. The diagnosis was partial avulsion fracture of the tibial tuberosity which has been called 'Osgood-Schlatter disease' in dogs.

Characteristics of Meniscus Tear in Tibial Plateau Fractures (경골 고평부 골절의 반월상 연골 파열 양상)

  • Lee, Dong-Hoon;Kim, Byung-Kuk;Kim, Jae-Hwa;Chung, Ju-Hwan;Lee, In-Sung;Lee, Jun-Ku;Lee, Soon-Chul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.1
    • /
    • pp.9-16
    • /
    • 2012
  • Purpose: Tibial plateau fractures cause a variety of problems in the knee joint. The purpose of this study was to investigate the characteristics of the meniscus injuries in tibial plateau fracture arthroscopically. Materials and Methods: Thirty-three out of 39 consecutive patients diagnosed with tibial plateau fractures underwent arthroscopy between March 2007 and March 2010. According to Schatzker classification, there were 1 type I (3.3%), 19 type II (53.3%), 4 type III (13.3%), 2 type IV (6.6%), 2 type V (6.6%) and 5 type VI (20%) fracture patterns in 33 patients. Results: Twenty-five cases (75.8%) had lateral meniscus tears. There were 18 meniscal tears in 19 cases of Schatzker type II fractures (94.7%), 3 meniscal tears out of 4 cases of Schatzker type III fractures (75%) and 4 meniscal tears out of 5 cases of Schatzker type VI fractures (80%). The most commonly affected site (22/25) was the anterior horn of the lateral meniscus. Of the 25 documented meniscal tears, all but one were vertical longitudinal tear at meniscocapsular junction so most cases are amenable to arthroscopic repair. Conclusion: Arthroscopy for the meniscal injuries in tibial plateau fractures is a valuable diagnostic and treatment tool, we recommend arthroscopy in tibial plateau fracture.

  • PDF

The Treatment of Tibial Condylar Fractures Using Arthroscopy (관절경을 이용한 경골 과부 골절의 치료)

  • Shin Dong-Min;Lee Sang-Hong;You Jae-Won;Lee Byoung-Ho;Ha Sang-Ho;Na Tae-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.1
    • /
    • pp.32-37
    • /
    • 2000
  • Purpose : We performed routinely arthroscopy to diagnose and treat intra-articular soft tissue pathology and tibial condylar fractures. The purpose of this study was to evaluate clinical value of arthroscopy in the tibial condylar fractures. Materials and Methods : The 31 tibial condylar fractures was examed by routine arthroscopy, 9 treated by conservative method and 22 treated by surgery at least follow up of 12 months. The authors analysed to the cause, classification, soft tissue injuries such as ligaments and menisci, treatment and results. Results : The most common type was Schatzker classification type I in 15 cases$(18\%)$ and intra-articular lesions and associated ligament injury were in 21 cases$(67\%)$. Most common lesion was meniscal tear in 16 cases and most common type of meniscal lesions was peripheral detachment in 7 cases$(44\%)$. Schatzker I, II fracture patterns were associated with the highest frequency of soft tissue injuries, especially medial collateral ligament and meniscal injuries. Conclusion : Arthroscopic examination is useful method to evaluate the intra-articular pathology and to treat the tibial condylar fractures.

  • PDF

Tibial Plateau Leveling Osteotomy for Treatment of Naturally Occurring Cranial Cruciate Ligament Rupture in Small Breed Dogs - Case Series (소형견에서 전 십자인대 단열의 치료를 위한 경골 고평부 평탄 골절단술의 평가)

  • Kim, Choong-Sup;Heo, Su-Young;Kim, Min-Su;Kim, Nam-Soo;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.483-489
    • /
    • 2014
  • This study describes a surgical technique and evaluates the clinical outcomes in small breed dogs with cranial cruciate ligament rupture (CCLR) treated with tibial plateau leveling osteotomy (TPLO). Seven skeletally mature dogs weighing less than 15 kg underwent unilateral TPLO to stabilize the stifle joint with CCLR. Clinical evaluation was performed via visual lameness score, range of motion (ROM), and thigh girth circumference (TC). Postoperative complications were recorded. All patients reached a grade 1 score at 1 week and grade 0 at 8 weeks postoperatively. The mean operated limb extension angle was 98.11%, 99.07%, and 98.73% of the mean extension angle of the contralateral limb at 4 weeks, 8 weeks, and 12 weeks postoperatively, respectively. The mean operated limb flexion angle was 98.07%, 95.88%, and 96.35% of the mean flexion angle of the contralateral limb at 4 weeks, 8 weeks, and 12 weeks postoperatively, respectively. The mean TC of the operated limb was 92.95%, 93.68%, and 95.44% of the mean TC of the normal limb at 4 weeks, 8 weeks, and 12 weeks postoperatively, respectively. Our outcomes for TPLO in small breed dogs are not worse than those previously reported for large breed dogs. Based on the result in the present study, CCLR in small dogs can be successfully managed with TPLO, as done in large breed dogs.

Arthroscopically assisted Operative Treatment of Tibial Plateau Fracture (관절경을 이용한 경골 고평부 골절에 대한 수술적 치료)

  • Byun, Jae-Yong;Kim, Bo-Hyun;Kang, Shin-Taek;Whang, Chan-Ha
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.45-52
    • /
    • 2006
  • Purpose: We evaluated the results of operative treatment of tibial plateau fractures using both arthroscopy and fluoroscopy. Materials and Methods: From May 1999 to February 2003, tibial plateau fractures were treated with arthroscopy. Tweenty seven patients are followed up over two years and the average follow-up period was fourty one months. We classified the fractures according to the Schatzker classification. We reduced the fracture over 2mm depression and displacement on articular surface in simple radiologic finding. Firstly, we treated the associated injuries and reduced the fractures using Steinmann pins. Then, we accomplished internal fixation or external fixation. Both the postoperative clinical and radiological results were evaluated by Rasmussen system. Results: In all tweenty seven cases, the fractures were healed completely in average fourty one months. According to Rasmussen classification, we obtained the excellent or good results in 23 cases. An average range of motion was between 2.5 degrees and 130 degrees. However, postoperative infection developed in one case and the other had loss of reduction. Conclusions: We consider that arthroscopically assisted operative treatment of tibial plateau fracture is a useful method. We can reduce joint surface correctly and treat associated injuries with arthroscopy. There are less complications.

  • PDF

Arthroscopic Reduction and Fixation of an Anterior Cruciate Ligament Avulsion Fracture From the Tibial Eminence Using Bioabsorbable Pins - Technical Note - (생흡수성 핀을 이용한 소아 경골 과간부 견열 골절의 관절경적 정복 및 고정 방법 - 수술 술기 -)

  • Lee, Su-Chan;Yang, Il-Soon;Seo, Hee-Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.183-187
    • /
    • 2009
  • Purpose: We describe a new and simple technique for arthroscopic fixation of tibial intercondylar eminence avulsion fracture using bioabsorbable pins in skeletally immature patients. Operative Technique: Diagnostic knee arthroscopy is performed using anterolateral and anteromedial portals. Fracture debris and blood clot are debrided to expose the injured site well. The fragment is reduced with the probe and fixed temporarily with a 1.1-mm diameter K-wire that is inserted percutaneously from the anterosuperior aspect of the knee joint. The drill guide is introduced into the joint and the fragment is secured by bioabsorbable, poly-p-dioxanone 1.3-mm pins inserted from different angles. The pins are 40 mm in length. The knee is placed in a long leg cast in extension for 4 weeks to assure that full extension is obtained. Conclusion: Arthroscopic fixation of an tibial intercondylar eminence avulsion fracture using bioabsorbable pins is not a technically demanding, suitable method that ensures fracture healing and restores the stability of the joint.

  • PDF