• Title/Summary/Keyword: 경계부재

Search Result 141, Processing Time 0.026 seconds

Effect of Transverse Reinforcement on the Shear Friction Capacity of Concrete Interfaces with Construction Joint (시공줄눈이 있는 콘크리트 경계면의 전단마찰 내력에 대한 보강철근의 영향)

  • Hwnag, Yong-Ha;Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.555-562
    • /
    • 2016
  • The objective of the present study is to evaluate the shear transfer capacity of transverse reinforcement at the concrete interfaces with smooth construction joint. The transverse reinforcing bars were classified into two groups: V-type for the arrangement perpendicular to the interface and X-type for inclined-crossing arrangement. The transverse reinforcement ratio at the interface varied from 0.0045 to 0.0135 for V-type and 0.0064 to 0.0045 for X-type. The mechanism analysis proposed for monolithic concrete interface, derived based on the upper-bound theorem of concrete plasticity, was modified to evaluate the shear friction capacity of concrete interfaces with smooth construction joint. Test results showed that the specimens with X-type reinforcement had lower amount of relative slippage at the interface and higher shear friction capacity than the companion specimens with V-type reinforcement. This observation was independent of the unit weight of concrete. The mean and standard deviation of the ratios between the experimental shear friction strength of smooth construction joints and predictions obtained from the proposed model are 1.07 and 0.14, respectively.

Topology Optimization Application for Initial Platform Design of 10 MW Grade Floating Type Wave-wind Hybrid Power Generation System (10MW급 부유식 파력-풍력 복합발전 시스템 플랫폼 초기설계를 위한 위상최적화 응용)

  • Song, Chang Yong;Lee, Kangsu;Hong, Keyyong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.3
    • /
    • pp.194-202
    • /
    • 2016
  • This study aims to review a topology optimization based on finite element analysis (FEA) for conceptual design of platform in the 10MW class floating type wave-wind hybrid power generation system (WHPGS). Two topology optimization theories, density method (DM) and homogenization design method (HDM) were used to check which one is more effective for a simplified structural design problem prior to the topology optimization of platform of WHPGS. From the results of the simplified design problem, the HDM was applied to the topology optimization of platform of WHPGS. For the conceptual platform design of WHPGS, FEA model was created and then the structural analysis was performed considering offshore environmental loads at installation site. Hydrodynamics analysis was carried out to calculate pressure on platform and tension forces in mooring lines induced from the offshore environmental loads such as design wave and current. Loading conditions for the structural analysis included the analysis results from the hydrodynamic analysis and the weights of WHPGS. Boundary condition was realized using inertia relief method. The topology optimization of WHPGS platform was performed using the HDM, and then the conceptual arrangement of main structural members was suggested. From the results, it was confirmed that the topology optimization might be a useful tool to design the conceptual arrangement of main structural members for a newly developed offshore structure such as the floating type WHPGS.

Occurrence of the lowermost part of the Yucheon Group and its SHRIMP U-Pb ages in Hyeonpoong and Bugok areas (현풍-부곡일원 최하부 유천층군의 산상과 SHRIMP U-Pb 연대)

  • Ghim, Yong Sik;Ko, Kyoungtae;Lee, Byung Choon
    • Economic and Environmental Geology
    • /
    • v.53 no.4
    • /
    • pp.397-411
    • /
    • 2020
  • The Cretaceous Yucheon Group is volcano-sedimentary successions that are formed by volcanic activities of the Gyeongsang Volcanic Arc. Lack of the detailed field researches on the Yucheon Group results in poor understanding of the formation time and the tempo-spatial development of the volcanic arc. Also, this causes difficulties to reconstruct the depositional history from the Sindong and Hayang groups to the Yucheon Group. In this study, we conducted field research targeting to the interface between topmost part of the Hayang Group and the lowermost part of the Yucheon Group from Hyeonpoong to Bugok areas. We also identified depositional timing of the lowermost part of the Yucheon Group using SHRIMP U-Pb zircon age dating. This Yucheon Group is composed of tuff and lapilli tuff, conformably overlying the Jindong Formation. The results of SHRIMP U-Pb zircon age are 97 to 96 Ma, indicating cessation of deposition of the Hayang Group at 97 to 96 Ma by input of pyroclastic materials into the Jinju Subbasin during the explosive volcanic eruptions from the Gyeongsang Volcanic Arc. In comparison with field researches and results of LA-ICP-MS zircon U-Pb age dating (88-85 Ma) of the lowermost part of the Yucheon Group in Gyeongju areas, the volcanic activities that formed Yucheon Group and their influence ranges varied tempo-spatially. This is probably due to distance difference from the volcanic arc or establishment of the paleo-drainage system from the Gyeongsang Volcanic Arc to nearby lowlands.

Evaluation of the Pull-out Resistance of the SMA Wire Connector (SMA 와이어를 이용한 연결재의 인발저항성능 평가)

  • Jung, Chi-Young;Woo, Tae-Ryeon;Lee, Jong-Han;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.130-137
    • /
    • 2019
  • Precast concrete (PC) structure is one of the type of the structures which is made in a facility prior to installing it to a construction field. The contact surfaces between two PC structures should be treated for obtaining enough binding force by inducing prestressing force. However, in the many cases, the contact surface causes the crack and leakage of water. These cracks and water leakage can cause the corrosion of the rebar, and the corrosion of the rebar can severely reduce the long-term durability. In this study, the SMA wire connector is suggested to solve the problem with the contact surfaces between two PC structures. The pull-out resistance of the suggested SMA wire connector is evaluated by conducting the tests to find the effect of the number of wires, shape of connector part, and shape memory effect. As a result of this study, the empirical formula is suggested to estimate the pull-out resistance related with the effects of the shape of the connector, shape memory effect, and the adhesive force. The validity between the estimated pull-out resistance and the measured value is confirmed.

A Study on the Evaluation of Radiation Safety in Opened-Ceiling-Facilities for Radiography Testing (천장 개방형 RT 사용시설의 방사선 안전성 평가 연구)

  • Sung-Hoe, Heo;Won-Seok, Park;Seung-Uk, Heo;Byung-In, Min
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.741-749
    • /
    • 2022
  • Radiography-Testing that verify the quality of welding structures without destruction are overwhelmingly used in industries, but many safety precautions are required as radiation is used. The workers for Radiography-Testing perform the inspection by moving the Iridium-192 radiation source embedded in the transport container of the gamma-ray irradiator within or outside the facility. The general facility is completely blocked about radiation from the outside with thick concrete, but if it is difficult for worker to handle object of inspection, facilities ceiling can be opened. A general facility may be constructed using a theoretical dose evaluation method because all exterior facilities are blocked, but if the ceiling is open, it is not appropriate to evaluate radiation safety with a simple theoretical calculation method due to the skyshine effect. Therefore, in this study, the radiation safety of the facility was evaluated in the actual field through an ion chamber survey-meter and an accumulated dose-meter called as OSLD, and the actual evaluation environment was modeled and evaluated using the Monte Carlo simulation code as FLUKA. According to the direction of the irradiation, the radiation dose at the facility boundary was difficult to meet the standards set by the regulatory authority, and radiation safety could be secured through additional methods. In addition, it was confirmed that the simulation results using the Iridium-192 source were valid evaluation with the actual measured results.

3D Finite Element Analysis of High Tension Bolted Joints (고장력 볼트 이음부의 3차원 유한요소 해석)

  • Shim, Jae Soo;Kim, Chun Ho;Kim, Dong Jo
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.407-414
    • /
    • 2004
  • Bridges in common use are expected to have more varieties of load in their connected members and bolts than in construction. Faults in connection members or bolts occur so often according to the time flow. One of the purposes of this study is to find out the behavior and structural features of high-tension bolted joints with faults that are very difficult and cost much to find out through experimentation with finite element analysis. Another purpose of this study is to provide sufficient data, estimated experimental results, and the scheme of the test plate for an economical experimental study in the future. Surveys of bridges with a variety of faults and statistical classifications of their faults were performed, as was a finite element analysis of the internal stress and the sliding behavior of standard and defective bridge models. The finite element analysis of the internal stress was performed according to the interval of the bolt, the thickness of the plate, the distance of the edge, the diameter of the bolt, and the expansion of the construction. Furthermore, the analysis explained the sliding behavior of high-tension bolt joints and showed the geometric non-linear against the large deformation, and the boundary non-linear against the non-linear in the contact surface, including the material non-linear, to best explain the exceeding of the yield stress by sliding. A normally bolted high-tension bolt joint and deduction of bolt tension were also analyzed with the finite element analysis of bridge-sliding behavior.

Late Pleistocene Unconformity in Tidal-Flat Deposit of Gyeonggi Bay, Western Coast of Korea (한국 서해 경기만 조간대 퇴적층의 후기 플라이스토세 부정합)

  • Jung, Hoi-Soo;Yoo, Hai-Soo;Seo, Jung-Mo;Paeng, Woo-Hyun;Lim, Dhong-Il
    • Journal of the Korean earth science society
    • /
    • v.24 no.8
    • /
    • pp.657-667
    • /
    • 2003
  • Deep-drilled core sampling and high-resolution seismic survey were carried out to identify a Holocene-late Pleistocene boundary in Gyeonggi Bay, western coast of Korea. Analysis of core sections revealed the existence of an oxidized and semi-consolidated sediment layer, Iying immediately below a Holocene horizon (Unit I) and being developed at the top of a late Pleistocene deposit (Unit II). The oxidized sedimentary layer (uppermost part of Unit II) is characterized by semi-consolidated, yellowish sediments showing signs of desiccation and alteration such as high N value, low water content, periglacial cryogenic structure, depletion of smectite, and high geochemical weathering index (Ba/Sr ratio). This feature, together with radiocarbon ages, suggests that the layer has formed as a result of prolonged subaerial exposure of Unit II sediments during the late Wisconsin sea-level lowstand, producing a regional unconformity. Such unconformitic-bounding surface corresponds to a prominent near-surface reflector (R), which is observed in seismic profiles obtained across the drilled-core sections in the study area. Consequently, the buried oxidized-sedimentary layer associated with the seismic reflector possibly plays a key horizon for the understanding of late Quaternary environmental changes as well as evidence of the emergence of the Yellow Sea shelf during the late Wisconsin sea-level lowstand.

Extraction of Waterline Using Low Altitude Remote Sensing (저고도 원격탐사 영상 분석을 통한 수륙경계선 추출)

  • Jung, Dawoon;Lee, Jong-Seok;Baek, Ji-Yeon;Jo, Young-Heon
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_2
    • /
    • pp.337-349
    • /
    • 2020
  • In this study, Helikite, Low Altitude Remote Sensing (LARS) platform, was used to acquire coastal images. In the obtained image, the land and water masses were divided using four types of region clustering algorithms, and then waterline was extracted using edge detection. Quantitative comparisons were not possible due to the lack of in-situ waterline data. But, based on the image of the infrared band where water masses and land are relatively clear, the waterlines extracted by each algorithm were compared. As a result, it was found that each algorithm differed significantly in the part where the distinction between water masses and land was ambiguous. This is considered to be a difference in the process of selecting the threshold value of the digital number that each algorithm uses to distinguish the regions. The extraction of waterlines through various algorithms is expected to be used in conjunction with a Low Altitude Remote Sensing system that can be continuously monitored in the future to explain the rapid changes in coastal shape through several years of long-term data from fixed areas.

A Study on the Improvement of Security Terminology (경호・경비 용어의 개선방안)

  • Kim, Hong Seong
    • Korean Security Journal
    • /
    • no.57
    • /
    • pp.231-252
    • /
    • 2018
  • we have long used foreign words in using the term for guard security despite the obvious existence of own language, the use of foreign terms is strong in foreign feeling in delivery. and also weakens the true meaning of security. there are no terms expressed independently in korean, and we(they) are negligent in finding them and use the terms of foreign language. as a result, we(they) brought about a lack of choice in terms of proper security for our langage. currenty, it is widely used as a security guard even though there is an appropraite word that corresponds to the meaning and meaning of security guards in our words, we still use enlish expressions. there is because the English language is used for convenience regardless of weather the term is appropraite or not, and as the power of the English language is great amid in the trend of globalization. lt is easy to use english without thinking in terms of the use of terminology. ultimitely, however, this is due to the lack of awareness of the korean language. with these reasons, we must find the term of security guards in pure korean language. until now, we have used the terms 'guard, security, protect' as the terms security and protection the term 'Jikim' refers to the korean language as a means to be vigilant and guarded. Jikim refers to the action of maintaining the current safe state. Like school jikimi, children safety jikimi and environment jikimi, Jikim is already being used in many places. Therefore, the term 'guard' should be changed to an appropriate Korean term, and the term 'Jikim' is considered to be the most appropriate term in various sections. so, 'Jikim' will be appropriate in korean, which corresponds to the meaning of security guards. the guardian here is called the Jikimi. Jikimi is a combination of the word Jikim and the korean pronounce 'I' which means people

Configurations of the Friction Dampers Installed in a Reinforced Concrete Shear Wall-Moment Frame System (철근콘크리트 전단벽-모멘트골조 형식 건물에 대한 마찰형 감쇠기 설치방식 비교연구)

  • Park, Ji-Hun;Kim, Gil-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.53-67
    • /
    • 2008
  • In this study, seismic control performance of friction dampers installed in a reinforced concrete shear wall-moment frame system, of which main lateral force resisting system is a shear wall, is investigated. Three configurations of friction dampers are investigated. One is a diagonal brace type reinforcing the shear wall directly, another is a diagonal brace type reinforcing the moment frame without the shear wall, and the other one is a vertical boundary element type installed at both ends of the shear wall. In addition, various levels of the total friction force and its distribution methods are examined. Time history analysis considering material nonlinearity is conducted for seismic loads increased by the enhanced design code compared to the initial design loads, and energy dissipation, lateral loads and structural member damages are analyzed. As a result, the shear wall-reinforcing diagonal brace type with the total friction force of 30 % of the reference friction force gives the best performance on the whole, and the distribution methods of the friction force do not have remarkable difference in effects. Also, concentrated installation in adjacent four stories shows just a little compromised control performance compared to the entire story installation.