• Title/Summary/Keyword: 경경골 술기

Search Result 21, Processing Time 0.021 seconds

Femoral Tunnel Obliquity between the Transtibial and Anteromedial Portal Technique in Single Bundle Anterior Cruciate Ligament Reconstruction (전방십자인대 단일 다발 재건술에서 경경골 술기 및 전내측 삽입구를 이용한 대퇴골 터널의 기울기)

  • Lee, Ju-Hong;Park, Jong-Hyuk;Bae, Hyeon-Kyeong;Kim, Jong-Gil;Wang, Sung-Il
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.9 no.1
    • /
    • pp.41-47
    • /
    • 2010
  • Purpose: To compare the obliquity of femoral tunnels prepared with transtibial (TT) versus anteromedial portal technique (AM) using x-ray in single-bundle anterior cruciate ligament (ACL) reconstruction. Materials and Methods: Among one-hundred thirty two patients who were undergoing ACL reconstruction from January 2007 to December 2009, thirty patients using TT and twenty patients using AM, those who had single-bundle ACL reconstruction, were evaluated with plain radiographs including anteroposterior, intercondylar notch and lateral view to compare the obliquity of bone tunnels. Results: The mean coronal obliquity of femoral tunnel for TT was $71^{\circ}$ (range; $65^{\circ}{\sim}77^{\circ}$), while for AM was $51^{\circ}$ (range; $39^{\circ}{\sim}60^{\circ}$) and the mean sagittal obliquity of femoral tunnel for TT was $22.7^{\circ}{\pm}7.8$, while for AM was $30.2^{\circ}{\pm}6.9$, their differences between them were statistically significant (P<0.05). However, there were no differences between two techniques on the tibial tunnel obliquity in coronal and sagittal plane. Conclusion: Anterior cruciate ligament reconstruction using AM portal technique allows more horizontally oriented and divergent femoral tunnel compared to that of transtibial technique. This seems to enable the graft placement into the femoral footprint and preserve the posterior cortical wall.

  • PDF

Clinical Results of the Single-bundle, Transtibial Posterior Cruciate Ligament Reconstruction: A Systematic Review (경경골 단일다발 후방십자인대 재건술의 임상 결과: 체계적 고찰)

  • Kim, Yeong-Mo;Lee, Cassandra A.;Matava, Matthew J.
    • 대한관절경학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.57-57
    • /
    • 2009
  • 관절경적 경경골 단일 다발 후방십자인대 재건술은 전통적으로 가장 흔하게 사용되는 사용되는 술기이다. 그러나, 후방십자 단독 파열시 이 술기의 결과에 대한 임상 평가 및 효용성에 대한 임상적 분석 자료가 거의 없는 실정이다. 이 술기를 시행받은 환자군들에서 객관적 슬관절 이완이 존재함에도 불구하고 주관적 슬관절 기능 장애는 우수한 결과를 나타낸다고 인정되어 왔다. 후방십자인대 단독 파열 후 경경골 단일 다발 재건술을 시행한 문헌 10개를 대상으로 잔존하는 후방 이완과 주관적, 객관적인 기능 평가, 활동성 정도, 환자 만족도, 골관절염의 발생 빈도, 술후 합병증을 체계적으로 고찰하였다. 술전 후방 슬관절 이완은 8.38~12.3 mm에서(4문헌) 술후 1.96~5.9 mm으로(9 문헌) 호전되었다. Lysholom 점수는 평균 81~100점이었다(9 문헌). IKDC는 75%에서 정상 또는 거의 정상의 결과를 보였다(6 문헌). 평균 Tegner 활동도는 4.7~6.3점이었다(8 문헌). 이번 고찰을 통한 결과에서 이 술기 후 퇴행성 변화가 관찰되었으며 보고된 합병증은 거의 없었다. 후방십자인대 단독 파열에서 경경골 단일 다발 재건술은 정상 슬관절의 안정성까지 회복하지는 못하나 한 등급 정도의 후방 슬관절 이완의 호전을 기대할 수 있다. 재활 및 운동으로의 회복에 대한 주관적 슬관절 점수는 80점이며 75%의 정상 또는 정상에 가까운 객관적 결과를 보여주었다. 이 술기가 퇴행성 관절염을 예방할 수는 없더라도 이러한 결과는 후방십자인대 재건 술기의 평가에 도움이 될 것으로 사료된다.

  • PDF

Transtibial Double Bundle PCL Reconstruction using TransFix Tibial Fixation - Technical Note - (TransFix 경골부 고정을 이용한 경 경골 두 다발 후방십자인대 재건술 - 수술 술기 -)

  • Lee, Yong-Seuk;Jung, Young-Bok;Ahn, Jin-Hwan;Kang, Bun-Jung;Shin, Yun-Chang;Kong, Chae-Gwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.203-208
    • /
    • 2006
  • Purpose: Previous transtibial double bundle posterior cruciate ligament (PCL) reconstruction methods have several problems in graft length and tibial fixation. We introduce new surgical method that is less restrictive by graft length and is more stable with single tibial fixation. Operative technique: After diagnostic arthroscopy, we prepare the graft, ream the tibial tunnel and perform the procedure for TransFix tibial fixation. Femoral 2 tunnel is made and graft is passed via anteromedial (AM) portal. Tibial fixation is done and femoral 2 graft is fixed sequentially at each knee position. Conclusion: TtransFix tibial single fixation method in double bundle PCL reconstruction provides more stable fixation, more free graft selection and prevents graft damage by passing the graft via AM portal.

  • PDF

ACL Reconstruction with Remnant Preserving Technique - Technical Note - (잔류조직 보존 술기를 이용한 전방 십자 인대 재건술 - 수술 술기 -)

  • Cho, Sung-Do;Youm, Yoon-Seok;Jeong, Ji-Young;Jeon, Hyung-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.82-85
    • /
    • 2009
  • Purpose: In anterior cruciate ligament (ACL) reconstruction, preservation of the remnant original tissue might promote graft healing and be helpful in proprioception. But this procedure is difficult and causes the notch impingement. So we introduce a surgical technique that makes a transtibial femoral tunnel at 10 or 2 o'clock position with preservation of remnant tissue. Surgical approach: We tried to preserve the remnant tissue and synovium as much as possible, especially those of tibial attachment and extending to the posterior cruciate ligament (PCL), so as to have some tension and to prevent notch impingement. We set the tibial drill guide at 40~45 degrees and the intra-articular guide tip was 1 mm anterior and medial to the conventional site. The starting point of tibial guide pin was proximal to the pes anserinus and anterior to the medial collateral ligament. When the reamer approached the cortical bone of the tibial articular surface, the reamer must be advanced very carefully to minimize injury to the remnant tissue. The tibial and femoral tunnel at 10 or 2 o'clock position were made with the reamer, the diameter of which was same with that of the graft. Conclusion: We report a remnant preserving technique in ACL reconstruction that makes a transtibial femoral tunnel at 10 or 2 o'clock position

  • PDF

Arthroscopic All-Inside Repair of Medial Meniscus Root Tear Using 18 Gauge Spinal Needle and Suture Anchor -A Report of Surgical Technique- (18 Gauge 척수 주사 바늘과 Suture Anchor를 이용한 내측 반월상 연골 경골 후방 부착부 파열의 관절경적 All-Inside 봉합술 - 수술 술기 보고 -)

  • Kim, Jong-Min;Jung, Sung-Hoon;Lee, Sang-Ho;Park, Byeong-Mun;Lee, Kil-Hyeong;Jeon, Ho-Seung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.1
    • /
    • pp.66-71
    • /
    • 2012
  • The posterior root of medial meniscus maintains normal meniscal function by circumferential hoop tension and prevents extrusion of meniscus and progression of osteoarthritis. A complete tear of posterior root of medial meniscus leads to loss of hoop tension, it is important to repair it and preserve the function of the medial meniscus. Recently, a variety of arthroscopic assisted reduction and repair techniques have been used. We create an arthroscopic all-inside suture technique using a 18 gauge spinal needle and suture anchor that is easier and more convenient compared with the previous techniques. So we report this technique with a review of current literatures.

  • PDF

Arthroscopic All Inside Repair of Lateral Meniscus Root Tear -Technical note- (외측 반월상 연골 경골 후방 부착부 파열의 관절경적 All-Inside 봉합술 - 수술술기 -)

  • Ahn, Jin-Hwan;Lee, Dong-Hoon;Chang, Moon-Jong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.1
    • /
    • pp.63-68
    • /
    • 2007
  • Purpose: The authors introduce a new technique of arthroscopic all inside repair using anterolateral and anteromedial portals for lateral meniscus root complete radial tear in patients who underwent concurrent anterior cruciate ligament (ACL) reconstruction. Operative technique: Arthroscope is placed through anteromedial portal and suture hook ($Linvatec^{TM}$, Largo, Florida, USA) is delivered through anterolateral portal. By rotating the suture hook, it penetrates posterior horn of the torn meniscus from femoral to tibial surface for vertical orientation. PDS No. 1 ($Ethicon^{TM}$, Somerville, NJ, USA) is delivered through the suture hook, and then it is withdrawn. Both end of PDS No. 1 are taken out through the anterolateral portal. MAXON 2-0 ($Syneture^{TM}$, Norwalk, Connecticut, USA) is used to penetrates remnant of tibial attachment of the torn meniscus from tibial to femoral surface in a same manner. MAXON 2-0 is changed for PDS No. 1 from tibial to femoral surface by shuttle relay technique. PDS No. 1 is tied using SMC (Samsung Medical Center) knot. Conclusion: All inside repair is a useful technique to achieve anatomical repair and to restore the hoop tension in lateral meniscus root complete radial tear.

  • PDF

Arthroscopic Reduction and Fixation of an Anterior Cruciate Ligament Avulsion Fracture From the Tibial Eminence Using Bioabsorbable Pins - Technical Note - (생흡수성 핀을 이용한 소아 경골 과간부 견열 골절의 관절경적 정복 및 고정 방법 - 수술 술기 -)

  • Lee, Su-Chan;Yang, Il-Soon;Seo, Hee-Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.183-187
    • /
    • 2009
  • Purpose: We describe a new and simple technique for arthroscopic fixation of tibial intercondylar eminence avulsion fracture using bioabsorbable pins in skeletally immature patients. Operative Technique: Diagnostic knee arthroscopy is performed using anterolateral and anteromedial portals. Fracture debris and blood clot are debrided to expose the injured site well. The fragment is reduced with the probe and fixed temporarily with a 1.1-mm diameter K-wire that is inserted percutaneously from the anterosuperior aspect of the knee joint. The drill guide is introduced into the joint and the fragment is secured by bioabsorbable, poly-p-dioxanone 1.3-mm pins inserted from different angles. The pins are 40 mm in length. The knee is placed in a long leg cast in extension for 4 weeks to assure that full extension is obtained. Conclusion: Arthroscopic fixation of an tibial intercondylar eminence avulsion fracture using bioabsorbable pins is not a technically demanding, suitable method that ensures fracture healing and restores the stability of the joint.

  • PDF

ACL Reconstruction using Transtibial Femoral Tunnel at 10 or 2 O'clock Position - Technical Note - (10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 - 수술 수기 -)

  • Cho, Sung-Do;Ko, Sang-Hun;Park, Mun-Soo;Jung, Kwang-Hwan;Cha, Jae-Ryong;Gwak, Chang-Youl;Kim, Sang-Woo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.209-213
    • /
    • 2006
  • Purpose: Conventional transtibial approach for the anterior cruciate ligament (ACL) reconstruction tended to place the femoral tunnel in too vertical position (11 or 1 o'clock), which could provide the postoperative anteroposterior (AP) stability but not provided the rotational stability. Therefore we present a surgical technique to make the transtibial femoral tunnel at 10 or 2 o'clock position. Surgical approach: To make a transtibial femoral tunnel at the 10 or 2 o'clock position, the direction and position of the tibial drill guide was important. We set the tibial drill guide at $40{\sim}45$ degrees and the intraarticular guide tip was 1 mm anterior and medial to the conventional site. The starting point for the guide pin on the proximal tibia was proximal to the pes anserinus and anterior to the medial collateral ligament. The tibial tunnel was initially drilled 1mm less than the diameter of the graft. Then femoral offset guide could be easily placed at 10 or 2 o'clock position through the tibial tunnel. The tibial tunnel and the femoral tunnel of 30 mm in length were made with the reamer that was same size with the graft. Conclusion: We report a surgical technique to create a transtibial femoral tunnel at 10 or 2 o'clock position in ACL reconstruction to provide the rotational stability as well as the AP stability.

  • PDF

Arthroscopic Pull-out Wire Fixation Using Cannulated Screw of Tibial Eminence Fractures (도관 나사못을 이용한 경골 과간 융기 골절의 관절경적 견인 봉합술)

  • Kim, Jong-Min;Kim, Hyung-Gyu;Park, Byeong-Mun;Song, Kyeong-Seop;Jung, Sung-Hoon;Noh, Haeng-Kee;Yoon, Jong-Joo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.254-258
    • /
    • 2009
  • Tibial eminence fracture is caused by distortion, excessive flexion and extension, varus and valgus injury of the knee joint in the form of avulsion fracture. A failure over the exact anatomical reduction of fragment can lead to instability and limitation of joint motion. Recently, a variety of arthroscopic assisted reduction and fixation technique have been used. In the tibial eminence fracture, we created an arthroscopic pull-out wire fixation technique using a cannulated screw that is easy and more convenient than in the conventional technique. So we report this technique with a review of current literatures.

  • PDF