• Title/Summary/Keyword: 결함유형

Search Result 153, Processing Time 0.028 seconds

Development of Ultra-compact LED Package and Analysis of Defect Type (극소형 LED 패키지의 개발과 불량 유형의 분석)

  • Lee, Jong Chan
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.12
    • /
    • pp.23-29
    • /
    • 2017
  • This paper introduces the mold technology for the development of ultra-compact package of less than 1mm, and also analyze the error pattern of the results using this mold technology. The existing ultra-small mold structure was one-piece, which caused the surface of EDM to be rough and increase the error rate. This has been an obstacle to further reducing the size of the mold. On the other hand, the proposed mold technology tries to overcome the limitation of the one-piece type by using the prefabricated type method. This paper also classify defect patterns in the results of the proposed mold structure and analyze the occurrence probability of each pattern to use as a basic data to develop a detector.

Failure Diagnosis Technology Trends and Analysis of Permanent Magnet Synchronous Motors for Aircraft Application (항공기용 영구자석 동기전동기 고장진단의 기술 동향 및 분석)

  • Minwoo, Kim;Sangho, Ko
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.6
    • /
    • pp.129-137
    • /
    • 2022
  • Recently, the technology of aircraft drivers has been transitioning from the existing hydraulically-focused mechanical system to an all-electric one due to the high precision and ease of maintenance of electric drivers. Consequently, the failure of an aircraft's electric motor can have fatal consequences. To ensure aircraft safety, efficient and timely fault diagnosis methods are required prompting the active pursuit of research into fault diagnosis technology. This paper introduces and analyses the failure types and failure diagnosis technology trends of permanent magnet synchronous motors among electric motors.

Fault-Free Process for IT System with TRM(Technical Reference Model) based Fault Check Point and Event Rule Engine (기술분류체계 기반의 장애 점검포인트와 이벤트 룰엔진을 적용한 무장애체계 구현)

  • Hyun, Byeong-Tag;Kim, Tae-Woo;Um, Chang-Sup;Seo, Jong-Hyen
    • Information Systems Review
    • /
    • v.12 no.3
    • /
    • pp.1-17
    • /
    • 2010
  • IT Systems based on Global Single Instance (GSI) can manage a corporation's internal information, resources and assets effectively and raise business efficiency through consolidation of their business process and productivity. But, It has also dangerous factor that IT system fault failure can cause a state of paralysis of a business itself, followed by huge loss of money. Many of studies have been conducted about fault-tolerance based on using redundant component. The concept of fault tolerance is rather simple but, designing and adopting fault-tolerance system is not easy due to uncertainty of a type and frequency of faults. So, Operational fault management that working after developed IT system is important more and more along with technical fault management. This study proposes the fault management process that including a pre-estimation method using TRM (Technical Reference Model) check point and event rule engine. And also proposes a effect of fault-free process through built fault management system to representative company of Hi-tech industry. After adopting fault-free process, a number of failure decreased by 46%, a failure time decreased by 56% and the Opportunity loss costs decreased by 77%.

CHARACTERISTICS OF ATTENTION DEFICIT OF ADHD ON COMPUTERIZED NEUROCOGNITIVE FUNCTION TESTS (전산화 신경인지기능검사를 이용한 주의력결핍/과잉운동 장애의 주의력결핍특성에 관한 연구)

  • Chung, Sun-Ju;Shin, Min-Sup;Ha, Kyoo-Seob;Hong, Kang-E
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.8 no.2
    • /
    • pp.242-255
    • /
    • 1997
  • Characteristics of attention deficit of attention-deficit hyperactivity disorder(ADHD) were investigated by administering six computerized attention tests of Vienna Test System and four neuropsychological tests to children aged 6-12, with ADHD(n=21) and age-matched normal control children(n=22). The findings indicated that ADHD children show lower level of vigilance, more decline of performance in vigilance task on time, and impaired preparedness to response. They also have selective attention deficit on monitoring tasks, but did not have sustained attention deficit compared with normal control children. On the tasks wich overload their information processing capacity, ADHD children show more impulsive response pattern than normal control children. The performance of ADHD was worse than control on the neuropsychological tests sensitive to frontal lobe dysfunction. The presense 'These' attention deficits supports the theory that the defect of ADHD is due to the dysfunction of more than one brain region, including brain stem reticular formation and frontal lobe.

  • PDF

Stability Analysis of the Foundation of Hazardous Material Storage Tank for Preventing Leakage Accidents (누출사고 방지를 위한 위험물 탱크의 기초 안정성 분석)

  • Lim, Jong-Jin;Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.96-100
    • /
    • 2020
  • The leakage of hazardous materials due to the defect in storage tank foundations is likely to cause tremendous fire disasters in the industry cluster area. Thus, adequate design and construction of the tank foundation is required for preventing tank leakage. In this study, four types of typical tank foundations were classified and modeled for 3D FEM analysis to perform stability evaluation on tank foundations. Furthermore, numerical analysis indicated that stress concentration just below the tank shells is 40 times that at the tank center. The settlement influence zone is about the tank radius and tank diameter in the horizontal and vertical directions, respectively. Thus, the appropriate guidelines for the design and construction of tank foundations were suggested via a comparison assessment of the numerical analysis results on the stress distribution and displacement of the tank foundations.

Characteristics of Various PD Signatures due to Defects in GIS (가스절연 개폐장치의 결함별 부분방전 신호 특성)

  • Goo, Sun-Geun;Lim, Jae-Sup;Park, Ki-Jun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1991-1993
    • /
    • 2004
  • 가스절연개폐장치에서 발생하는 사고를 예방하기 위해서는 방전 위치 및 방전원인을 방전신호로부터 유추하는 것이 핵심 기술이다. 본 논문에서는 다양한 방전원에 대한 신호 유형을 정리하고 방전원별 특성을 추출하여 실제 부분방전 발생시 방전원을 쉽게 유추할 수 있도록 하였다.

  • PDF

Type Classification and Shape Display of Brazing Defect in Heat Exchanger (열교환기 브레이징 결함의 유형 분류 및 형상 디스플레이)

  • Kim, Jin-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.2
    • /
    • pp.171-176
    • /
    • 2013
  • X-ray cross-sectional image-based inspection technique is one of the most useful methods to inspect the brazing joints of heat exchanger. Through X-ray cross-sectional image acquisition, image processing, and defect inspection, the defects of brazing joints can be detected. This paper presents a method to judge the type of detected defects automatically, and to display them three-dimensionally. The defect type is classified as unconnected defect, void, and so on, based on location, size, and shape information of defect. Three-dimensional display which is realized using OpenGL (Open Graphics Library) will be helpful to understand the overall situation including location, size, shape of the defects in a test object.

새로운 오메프라졸염의 개발 및 제제화 연구

  • 이계주;이기명;이창현;우종수
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.329-329
    • /
    • 1994
  • OMZ과 HP-$\beta$-CD 포접화합물의 유형은 $A_{L}$ type의 가용성 복합체이며, CD, UV, IR, DSC, XRD pattern 및 $^1$H-NMR 방법으로 측정한 포접화합물의 결함형태는 OMZ의 benzimidazole부분이 HP-$\beta$-CD 공동에 포접된 형태이었고, OMZ과 HP-$\beta$-CD의 결합조성몰비는 1:1, 안정도 상수는 약 34 M$^{-1}$이었다. 또한 cholestyramine 수지와 OMZ 복합체는 방출양상이 신속하였다. OMZ-cholestyramine 수지염은 안정성이 양호하고 용출율이 우수한복합체로 경구용 재제를 개발할 수 있었으며, 용출시험 및 산 저항성이 양호하고 pellet의 제조에 있어서 core의 제조는 정제수 : 에탄올(7: 3) 결합액을 이용하여 lactose를 주로 사용하고 기타 PEG 6000, sorbitol, Avicel PH101, sodium lauryl sulfate 및 무수 PVP K-30을 적절히 배합하여 제조하고, 장용코팅의 내산성은 90.5% 이었으며, 소장에서의 용출경향이 85%이상이 10분 이내에 용출되어 규정에 적합하였다.

  • PDF

A study on the structure-vibration analysis of power transformer(154kV Single Phase) (전력용 변압기(154kV 단상)의 구조진동 해석에 관한 연구)

  • Kim, Young-Dal;Park, Woo-Yong;Kim, Seun-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.203-206
    • /
    • 2008
  • 전력용 변압기의 고장 원인이 과도 진동에 의한 기계적 결함이 대부분을 차지하고 있으며, 그 원인 120Hz배수 조합으로 이루어진 진동이다. 전력용변압기에 작용되는 기계적 가진력을 유형별로 분류하고, 기계나 구조물에 미치는 진동전달 경로를 통해 전력용변압기의 기계적 손상 메커니즘을 규명한다. 일반적으로 120Hz 성분의 진동이 변압기변의 외함, 부싱, 부흐홀쯔, 방압변 및 탭체인쳐의 진동영향에 대해 확인하였다.

  • PDF

A Field Investigation of Defect Type for Development of Maintenance Manual of Han-ok (한옥 유지관리매뉴얼 개발을 위한 결함 유형 현장 조사)

  • Lee, Jong Shin;Choi, Gwang Sik;Yang, Jeong Moo
    • Journal of the Korea Furniture Society
    • /
    • v.24 no.3
    • /
    • pp.302-308
    • /
    • 2013
  • To collection of field data for development of maintenance manual of Han-ok, we investigated defects which occurred in members of Han-ok by field investigation. The noticeable defects were wood cracks, gaps that developed between wood pillar and wall or wood window frame and tenon joints. The most common biological defect was blue stain which was created in log. The mold generation was observed on exterior wood and wall which get wet by precipitation. The gaps between members of Han-ok pointed out as defect that is urgently improved by residents of Han-ok. The reason is mainly due to poor of insulation in winter by bad confidentiality. The maintenance work of defect such as gap was conducted personally. As a result, the repair parts were ugly for unfamiliar repair work.

  • PDF