• Title/Summary/Keyword: 결정오차

Search Result 1,957, Processing Time 0.036 seconds

A study on the optimal geometrical placement of eLoran stations in Korea (eLoran 송신국 배치 최적화 방안 연구)

  • Lee, Chang-Bok;Shin, Mi-Young;Hwang, Sang-Wook;Lee, Sang-Jeong;Yang, Sung-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.37 no.1
    • /
    • pp.35-40
    • /
    • 2013
  • In the eLoran navigation system, the dominant deterioration factors of navigation accuracy are the TOA measurement errors on user receiver and the GDOP between the receiver and the transmitters. But if the ASF data measured at dLoran reference station are provided for users through the Loran data channel, it will be possible to correct the TOA measurement errors. The position accuracy can be determined by the DOP depending on the geometry of receiver-transmitters, and their optimal placement improves the navigation accuracy. In this study we determined the geometric placement in case of up to six stations, and evaluated the performance of position accuracy for the receiver-transmitter geometry set of eLoran stations. The proposed geometry of eLoran stations can be referred for the construction of eLoran infrastructure meeting the capability of HEA for maritime, and time/frequency users in Korea.

A Feasibility Study on Multiple DME Positioning Considering Time-Misaligned Range Measurements (시각 비동기 오차를 고려한 다중 DME 측위 적용 방안 연구)

  • Choi, Kwang-Ho;Lim, Joon-Hoo;Yoo, Won-Jae;So, Hyoungmin;Lee, Hyung-Keun
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.6
    • /
    • pp.534-543
    • /
    • 2015
  • This paper introduces the time-misalignment error between multiple range measurements acquired by an onboard distance measuring equipment (DME) interrogator and proposes an efficient position determination method that can mitigate the negative effects of the time-misalignment error. The introduced time-misalignment error does not occur in conventional utilization of DME combined with VHF omnidirectional range (VOR). The proposed position determination method projects all the DME range measurements acquired irregularly during an interval to the same time instance where the aircraft position is determined. By the simulation utilizing a representative aircraft trajectory, it is shown that it is possible to estimate the horizontal position accurately without any changes of ground DME facilities.

Sample size using response rate on repeated surveys (계속조사에서 응답률을 반영한 표본크기)

  • Park, Hyeonah;Na, Seongryong
    • The Korean Journal of Applied Statistics
    • /
    • v.31 no.5
    • /
    • pp.587-597
    • /
    • 2018
  • Procedures, such as sampling technique, survey method, and questionnaire preparation, are required in order to obtain sample data in accordance with the purpose of a survey. An important procedure is the decision of the sample size formula. The sample size formula is determined by setting the target error and total cost according to the sampling method. In this paper, we propose a sample size formula using population changes over time, estimation error of the previous time and response rate of past data when the target error and the expected response rate are given in the simple random sampling. In actual research, we use estimators that apply complex weights in addition to design-based weights. Therefore, we induce a sample size formula for estimators using design-based weights and nonresponse adjustment coefficients, that can be a formula that reflects differences in response rates when survey methods are changed over time. In addition, we use simulations to compare the proposed formula with the existing sample size formula.

Performance Analysis of MSAGF-MMA Adaptive Blind Equalization Algorithm with Variable Step Size Using Input Power Signal and Decision-Directed Error Signal (입력 전력 신호와 결정지향 오차 신호를 이용한 가변 스텝 크기를 가지는 MSAGF-MMA 적응 블라인드 등화 알고리즘의 성능 분석)

  • Jeong, Young-Hwa
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.53-58
    • /
    • 2020
  • This paper is concerned with the performance analysis of MSAGF-MMA with variable step size whose step size varies according to input power signal and decision-directed error signal. The proposed algorithm is made to change according to the input power signal which can reliably increase the convergence speed to the steady state by making the step size less affected by the fluctuation of the input signal in the MMA having the binary flag obtained from the modified Stop-and-Go algorithm. At the same time, the step size can be varied according to the decision-directed error signal so that the residual error can be reduced in the steady state. As a result of computer simulations, it is confirmed that the proposed algorithm has a very good performance in the evaluation of residual ISI and averaged-MSE in steady state as well as in terms of convergence speed to steady state compared to MMA and MSAGF-MMA.

Precision GPS Orbit Determination and Analysis of Error Characteristics (정밀 GPS 위성궤도 결정 및 오차 특성 분석)

  • Bae, Tae-Suk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.4
    • /
    • pp.437-444
    • /
    • 2009
  • A bi-directional, multi-step numerical integrator is developed to determine the GPS (Global Positioning System) orbit based on a dynamic approach, which shows micrometer-level accuracy at GPS altitude. The acceleration due to the planets other than the Moon and the Sun is so small that it is replaced by the empirical forces in the Solar Radiation Pressure (SRP) model. The satellite orbit parameters are estimated with the least-squares adjustment method using both the integrated orbit and the published IGS (International GNSS Service) precise orbit. For this estimation procedure, the integration should be applied to the partial derivatives of the acceleration with respect to the unknown parameters as well as the acceleration itself. The accuracy of the satellite orbit is evaluated by the RMS (Root Mean Squares error) of the residuals calculated from the estimated orbit parameters. The overall RMS of orbit error during March 2009 was 5.2 mm, and there are no specific patterns in the absolute orbit error depending on the satellite types and the directions of coordinate frame. The SRP model used in this study includes only the direct and once-per-revolution terms. Therefore there is errant behavior regarding twice-per-revolution, which needs further investigation.

Simulation Study for the Distortion Correction of Digital Angiographic Images using Geometric Transformation (디지털 혈관 조영상의 기하학적 왜곡 보정을 위한 모의 실험 연구)

  • 진호상;신동훈;허순녕;곽철은;최보영;이형구;서태석
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.365-373
    • /
    • 2002
  • Accurate localization of target lesion is required to protect normal peripheral tissue and irradiate exactly to tumors in stereotactic radiosurgery(SRS). Digital angiography is one of the most effective diagnostic tools to detect and identify the target tumors. However, it shows pincushion distortion due to the characteristics of the image intensifier. We have implemented a simulation study for the correction of distortion using the geometric transformation. Phantom images were produced transformation. In conclusion, the geometric transformation could effectively be used for the pincushion distortion of image intensifier and there was no significant different between two methods indicating 2% correction error from the ideal image in all cases.

Performance of Automatic Guidance System for Combine at Turning and Curved Paths (자율주행시스템을 이용한 콤바인의 무인자율 선회 및 곡선 주행)

  • 최창현;양원준;남궁만준;김용주
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.494-500
    • /
    • 2002
  • 본 연구의 목적은 DGPS와 자이로 센서를 장착하여 무인으로 콤바인을 직선주행, 선회 및 곡선주행, 직진주행 중 1 m 오프셋(offset) 주행시켰을 때, 무인 자율주행의 성능을 분석하고 개선하는데 있다. 콤바인의 무인자율주행 시스템은 콤바인의 현재위치를 인식하고, 주행하고 있는 콤바인의 주행방향을 감지하여 미리 설정된 경로를 따라 자율적으로 주행하며, 주행 중에 장애물이 검출되면 정지할 수 있도록 개발하였다. 콤바인의 무인 자율주행시스템은 DGPS의 입력 신호로부터 콤바인의 현재위치를 결정하고, 자이로 센서의 입력신호로부터 주행방향을 알 수 있다. 또한 장애물의 감지를 위한 초음파 센서, 콤바인의 주행방향을 조정하는 유압 작동부, 좌.우의 조향레버를 조정하는 서보모터 시스템, 마이크로 컴퓨터로 구성된 제어기와 입출력 인터페이스로 구성되어 있다. 콤바인 자율주행시스템의 프로그램은 DGPS 신호, 자이로 센서 등을 수신하는 수신 프로그램, DGPS 신호등으로부터 관련 변수들을 분석하여 콤바인의 조향수준을 결정하고, 유압실린더 등을 제어하는 제어 프로그램과 콤바인의 이동경로를 저장하는 저장 프로그램으로 구성되어 있다. 콤바인의 무인주행 실험결과 RMS 오차는 50 m 직선주행에서 7.52 cm, 20 m 직선주행 후 1 m 오프셋 된 30 m의 직선주행에서 21.85 cm, 20 m 직선주행 후 90$^{\circ}$선회하여 25 m 직선주행에서 7.55 cm, 반지름 23 m의 원주 사분면 곡선주행에서는 25.98 cm로 각각 나타났다. 소 구획의 포장에서 벼는 가로 방향으로 25~30 cm, 세로 방향으로 15~20 cm의 간격으로 심어져 있다. DGPS 신호에 의한 위치 결정을 할 때 자체 오차 10 cm를 고려하여도 콤바인이 직선구간 및 선회구간을 주행하며 수확작업이 가능함을 알 수 있었다. 그러나 곡선구간에서는 최대오차가 65.5 cm로 매우 크게 나타나, 콤바인을 무인 자율주행으로 수확하기에는 어려움이 있는 것으로 나타났다. 실제 포장은 이론적인 완전한 직선보다는 작은 굴곡이 있는 곡선의 형태가 이루어져 있으므로 주행 오차를 감소하기 위해서는 기계시각을 이용하면 보다 정밀한 조향을 이룰 수 있을 것으로 예상된다. 포장에서 DGPS 신호, 자이로 센서 등을 이용한 콤바인의 무인주행 장치는 무인 수확작업을 위한 가능성을 보여주었고, 일부의 센서의 기능을 개선하면 만족한 성능을 나타낼 수 있을 것으로 판단된다.

  • PDF

전신 정위 프레임을 이용한 환자의 움직임 및 외부자세 setup 오차 분석

  • 정진범;정원균;서태석;최경식;지영훈;이형구;최보영
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.59-59
    • /
    • 2003
  • 목적 : 환자의 호흡에 의한 움직임 및 부정확한 환자 자세 setup 때문에 3 차원 전신 정위 방사선치료,3 차원 입체조형 방사선치료 IMRT와 같은 방사선 치료기술에서 병소에 대한 정확한 표적 위치측정은 매우 어려운 실정이다. 그러므로 본 연구는 방사선 치료시 환자의 움직임을 최대한 고정시켜 줄 수 있으며 환자 자세에 대한 setup 오차를 감소시키고 환자 전신에 산재한 병소의 위치를 좌표화할 수 있는 전신 정위 프레임 제작과 제작한 프레임에 대한 고정효과 및 재현성을 나타내는 환자 자세의 setup 오차를 평가하는데 있다. 재료 및 방법 : 자체 제작한 전신 정위 프레임 구조는 CT 영상 촬영 가능성에 중점을 두고 병소 표적의 좌표실현 및 환자체형에 따른 다양성 그리고 프레임에 대한 견고성 및 안정성 확인에 초점화하여 제작하였다. 이렇게 제작된 전신 정위 프레임에 대한 방사선 투과율 측정 실험과 CCTV 카메라와 DVR(Digital Video Recorder)를 이용해 환자 자세 변화에 대한 영상을 획득하여 matlab으로 구현한 오차분석용 프로그램으로 환자 외부자세에 대한 오차 비교 평가하고 CT 촬영에 의한 가상표적 위치측정 실험을 수행하였다. 또 한 고정벨트 추가 사용으로 인한 환자의 고정효과 정도를 살펴보았다. 결과 : 제작된 전신 정위 프레임에 대한 방사선 투과율은 마그네트론 10, 21 MeV의 에너지에서 95, 96% 의 투과율이 측정되었고 30 $^{\circ}$. 60 。각도의 경사로 빔이 전달될 때는 90.3, 94.4% 가 측정되었다. CCTV 카메라를 이용하여 흉부 및 복부의 움직임을 촬영한 영상을 Matlab프로그램으로 구현한 오차분석 프로그램을 적용한 결과, 환자 자세에 대한 오차의 평균값은 흉부의 lateral 방향에서는 3.63$\pm$1.4 mm, AP 방향에서는 2.1$\pm$0.82 mm이었다. 그리고 복부의 later의 방향에서는 7.0$\pm$2.1 mm, AP 방향에서는 6.5$\pm$2.2 mm 이었다. 또한 표적 위치측정을 위해서 환자의 피부에 임의의 가상표적을 부착하고 CT 촬영한 영상결과, 프레임으로 가상표 적에 대한 위치를 정확히 파악할 수 있었다. 결론 : 제작된 프레임을 적용하여 방사선투과율 측정실험, 환자 외부자세에 대한 오차 측정실험, 가상표적 위치측정 실험 등을 수행하였다. 환자 외부자세에 대한 오차 측정실험 경우, 더 많은 Volunteer를 적용하여 보다 정확한 오차 측정실험이 수행되어야 할 것이며 정확한 표적 위치 측정실험을 위해서 내부 마커를 삽입한 환자를 적용한 임상실험이 수행되어야 할 것이다. 또한 위치결정에서 획득한 좌표값의 정확성을 알아보기 위해서 팬톰을 이용한 방사선조사 실험이 추후에 실행되어져야 할 것이다. 그리고 제작된 프레임에 Rotating X선 시스템과 내부 장기의 움직임을 계량화하고 PTV에서의 최적 여유폭을 설정함으로써 정위 방사선수술 및 3 차원 업체 방사선치료에 대한 병소 위치측정과 환자의 자세에 대한 setup 오차측정 결정에 도움이 될 수 있을 것이라고 사료된다.

  • PDF

Experimental Study on Source Locating Technique for Transversely Isotropic Media (횡등방성 매질의 음원추적기법에 대한 실험적 연구)

  • Choi, Seung-Beum;Jeon, Seokwon
    • Tunnel and Underground Space
    • /
    • v.25 no.1
    • /
    • pp.56-67
    • /
    • 2015
  • In this study, a source locating technique applicable to transversely isotropic media was developed. Wave velocity anisotropy was considered based on the partition approximation method, which simply enabled AE source locating. Sets of P wave arrival time were decided by the two-step AIC algorithm and they were later used to locate the AE sources when having the least error compared with the partitioned elements. In order to validate the technique, pencil lead break test on artificial transversely isotropic mortar specimen was carried out. Defining the absolute error as the distance between the pencil lead break point and the located point, 1.60 mm ~ 14.46 mm of range and 8.57 mm of average were estimated therefore it was regarded as thought to be 'acceptable' considering the size of the specimen and the AE sensors. Comparing each absolute error under different threshold levels, results showed small discrepancies therefore this technique was hardly affected by background noise. Absolute error could be decomposed into each coordinate axis error and through it, effect of AE sensor position could be understood so if optimum sensor position was able to be decided, one could get more precise outcome.

Temperature Control of Greenhouse Using Ventilation Window Adjustments by a Fuzzy Algorithm (퍼지제어에 의한 자연환기온실의 온도제어)

  • 정태상;민영봉;문경규
    • Journal of Bio-Environment Control
    • /
    • v.10 no.1
    • /
    • pp.42-49
    • /
    • 2001
  • This study was carried out to develop a fuzzy control technique of ventilation window for controlling a temperature in a greenhouse. To reduce the fuzzy variables, the inside air temperature shop was taken as one of fuzzy variables, because the inside air temperature variation of a greenhouse by ventilation at the same window aperture is affected by difference between inside and outside air temperature, outside wind speed and the wind direction. Therefore, the antecedent variables for fuzzy algorithm were used the control error and its slop, which was same value as the inside air temperature slop during the control period, and the conclusion variable was used the window aperture opening rate. Through the basic and applicative control experiment with the control period of 3 minutes the optimum ranges of fuzzy variables were decided. The control error and its slop were taken as 3 and 1.5 times compared with target error in steady state, and the window opening rate were taken as 30% of full size of the window aperture. To evaluate the developed fuzzy algorithm in which the optimized 19 rules of fuzzy production were used, the performances of fuzzy control and PID control were compared. The temperature control errors by the fuzzy control and PID control were lower than 1.3$^{\circ}C$ and 2.2$^{\circ}C$ respectively. The accumulated operating size of the window, the number of operating and the number of inverse operating for the fuzzy control were 0.4 times, 0.5 times and 0.3 times of those compared with the PID control. Therefore, the fuzzy control can operating the window more smooth and reduce the operating energy by 1/2 times of PID control.

  • PDF