• Title/Summary/Keyword: 견고성 고정

Search Result 62, Processing Time 0.021 seconds

Treatment of Pseudoarthrosis due to Nonunion of the Acromial Fracture with LCP - Case Report - (견봉 골절의 불유합으로 기인한 가관절증의 잠김 금속판을 이용한 치료 - 증례보고 -)

  • Kim, Yong-Min;Park, Kyoung-Jin;Kim, Dong-Soo;Choi, Eui-Sung;Shon, Hyun-Chul;Cho, Byung-Ki;Park, Ji-Kang;Keum, Sang-Wook;Jeong, Ho-Seung
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.130-134
    • /
    • 2013
  • A painful pseudoarthrosis will develop due to a delay in diagnosis and treatment, and surgical care is required. Treatment of pseudoarthrosis is really difficult because the acromion is a thin flat bone that is difficult to be fixed firmly. A 52-year-old woman with multiple trauma had an acromial fracture that was not detected until it had caused pain after ambulation. Open reduction and internal fixation with a variable angle locking compression plate for distal radius and autogenous iliac bone graft were performed. At nine months after the operation, there was partial tear in the supraspinatus tendon, and arthroscopic repair of the supraspinatus tendon was performed. At nine months after the operation, radiographs showed a complete union. At three months after tendon repair, the patient had excellent function of the shoulder. We have reported a case of a successful treatment of nonunion and pseudoarthrosis of acromial fracture that is difficult to be fixed.

Comparison of Enzymatic Activity and Cleavage Characteristics of Trypsin Immobilized by Covalent Conjugation and Affinity Interaction (공유결합과 친화력결합에 의한 고정화 Trypsin의 효소역가와 절단특성 비교)

  • Jang, Dae-Ho;Seong, Gi-Hun;Lee, Eun-Kyu
    • KSBB Journal
    • /
    • v.21 no.4
    • /
    • pp.279-285
    • /
    • 2006
  • We investigated the effects of immobilization chemistry on the yield of immobilization and the bioactivity of the immobilized enzymes. Trypsin as a model protein and macroporous polymer beads(Toyopearl AF 650M, Tosho Co., Japan) was used as a model matrix. Four methods were used to immobilize trypsin; covalent conjugation by reductive amination(at pH 10.0 and pH 4.0) and affinity interaction via streptavidin-biotin, and double-affinity interaction via biotin-streptavidin-biotin system. The covalent conjugation immobilized $3{\sim}4$ mg/ml-gel, ca. 3-fold higher than the affinity method. However, the specific activity of the covalently(pH 10.0) and affinity-immobilized trypsin(via streptavidin-biotin) are ca. 37% and 50%, respectively, of that of the soluble enzyme(on the low-molecular-weight BAPNA substrate). When the molecular size of a substrate increased, the affinity-immobilized trypsin showed higher clavage activity on insulin and BSA. This result seemed to indicate the streptavidin-biotin system allowed more steric flexibility of the immobilized trypsin in its interaction with a substrate molecule. To confirm this, we studied the molecular flexibility of immobilized trypsin using quartz crystal microbalance-dissipation. Self-assembled monolayers were formed on the Q-sensor surface by aminoalkanethiols, and gultaraldehyde was attached to the SAMs. Trypsin was immobilized in two ways: reductive amination(at pH 10.0) and the streptavidin-biotin system. The dissipation shift of the affinity-immobilized trypsin was $0.8{\times}10^{-6}$, whereas that of the covalently attached enzyme was almost zero. This result confirmed that the streptavidin-biotin system allowed higher molecular flexibility. These results suggested that the bioactivity of the immobilized enzyme be strongly dependent on its molecular flexibility.

Improvement of the Elbow Function with Early Mobilization and Rigid Fixation of Coronoid Fracture by Tension Band Technique (압박 긴장대 방법을 이용한 구상 돌기 골절의 견고한 고정과 조기 운동을 통한 주관절 기능의 향상)

  • Rhyou, In-Hyeok;Suh, Bo-Gun;Kim, Hyung-Jin;Chung, Chae-Ik;Kim, Kyung-Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.159-166
    • /
    • 2009
  • Purpose: We wanted to evaluate the surgical results of early mobilization after rigid fixation of small coronoid fracture using the tension band technique Materials and Methods: Eight cases of coronoid fracture were fixed with the tension band technique and using K-wire and wire through the medial approach. All the cases were Regan-Morrey type 2. According to O'Driscoll, they were classified as 5 cases of the tip type (subtype 2) and 3 cases of the anteromedial type (1 case of subtype 2, and 2 case of subtype 3). The associated collateral ligament injuries (6 cases) and radial head/neck fractures (4 cases) were managed simultaneously. After immobilization for 5~7 days, active ROM exercise with a fitted hinge brace started and continued till postoperative 6 weeks. The patients were assessed for pain, ROM and functional disability using the Mayo elbow performance score (MEPS) at an average of 11 months (range: 6~28 months). The ulnar nerve symptoms were also investigated. Results: We observed solid union in all the coronoid fractures without hardware failure. An average of 2.2 wires (range: 2~4) were used. The mean extension was $3^{\circ}$(range: $0^{\circ}\sim25^{\circ}$), the mean flexion was $137^{\circ}$(range: $130^{\circ}\sim140^{\circ}$), the mean pronation was $69^{\circ}$(range: $45^{\circ}\sim90^{\circ}$) and the mean supination was $78^{\circ}$(range: $45^{\circ}\sim90^{\circ}$). The mean MEPS was 96 (range: 65~100). Ulnar nerve symptoms occurred at postoperative one day and persisted in one patient with the terrible triad of taking radial head excision and residual medial instability. Conclusion: The tension band technique uses easily obtained, economic K-wires and the wire was strong enough to permit early elbow ROM exercise and the technique might improve the elbow function. It was especially useful for fixation of multiple small fragments.

Transpatellar Cannulated Screw Fixation of Displaced Tibial Intercondylar Eminence Fractures (전위성 경골 과간 융기부 골절의 슬개골 하단을 통한 삽관 나사못 고정술)

  • Nha Koung Wook;Jung Byung Hyun;Suh Jin Soo;Suk Seung Yeub;Park Gyu Won;Chae Dong Ju
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.1
    • /
    • pp.25-30
    • /
    • 2002
  • Purpose : To evaluate the clinical results of displaced tibial intercondylar eminence fractures which were treated with transpatellar cannulated screw fixation. Materials and Methods : Ten patients with displaced tibial intercondylar eminence fractures were treated between December 1998 and May 2001 and then followed up for more than one year. They were treated arthroscopic reduction and fixation of fracture site by cannulated screw through the hole of nonarticular surface of inferior patella. They were prospectively evaluated with regard to their clinical and radiologic results. Results : Radiologic unions occurred at an average of 9.2 weeks. Average anterior displacements were 1.8 mm in stress x-rays and 1.1 mm in KT-2000 arthrometer. Average loss of extension was $4.1^{\circ}$. Functional results were excellent in 7 cases and good in 3 cases. Conclusion : Arthroscopic transpatellar cannulated screw fixation is one of the useful methods for the treatment of displaced tibial intercondylar eminence fractures.

  • PDF

An Intelligent Mobile Agent System with Planning Capability (계획 기능을 가진 지능형 이동에이전트 시스템)

  • Seok, Hwang-Hee;Kim, In-Cheol
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.11
    • /
    • pp.3417-3426
    • /
    • 2000
  • Most of conventional mobile agent systems requre that the users or the programmer should give the mobile agenl its detail behavioral script for accomplishing the given task. And during its runtime, such mobile agents just behave acording to the fixed script given by its user. Therefore it is impossible that conventional mobile agents autonomously build their own plans and execute. There in considering their ultirnale goals and the dynamic world states. One way to overcome such limtations of conventional mobile agent systems is to develop an mielligent mobile agent system ombedding a reactive planner.In this paper, we design both a modelof agent inobility and a model of inter-agent commuication based upon the representative reactive planning agent architecture called JAM. An then we develop an intelligent mobile agent system with planing capability, IMAS, by implementing addtional basic actions for agent moves and inter-agent comunication within JAM according too the predevined models. Unlike conventional mobile agents, IMAS agents can be able to adapt, their behaviors to the dynamic changes of their anvironment as well as build their own plans autonomously. Thus IMAS aents can snow higher flexibility and robustness than the conventional ones.

  • PDF

Operative Treatment of the Displaced Midshaft Clavicle Fracture Using Precontoured Locking Compression Plate (Precontoured Locking Compression Plate를 이용한 전위성 쇄골 간부 골절의 수술적 치료)

  • Kim, Jeong Woo;Kang, Hong Je;No, Sung Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.117-122
    • /
    • 2012
  • Purpose: To assess the effectiveness of internal fixation using a precontoured locking compression plate for the treatment of the displaced clavicle fracture by analyzing both radiological and clinical outcomes. Materials and Methods: We reviewed 34 cases of displaced clavicle shaft fracture treated by internal fixation using precontoured locking compression plates between May 2009 and February 2010. Radiological outcomes were analized on the basis of bone union and the differences between the time for bone union depending on sex and age. Clinical outcomes were analyzed on the basis of quick DASH Scores and the differences in the range of motion of the affected shoulder compared to the contralateral shoulder. Results: In the radiological evaluation, all fractures showed bone union, and the average time for bone union was 12.3 weeks, without delayed unions. Time for bone union did not differ significantly with respect to sex and age (p=0.87). In the clinical evaluation, the average final quick DASH Score was 23.5 (range, 12~42). At final follow up, the range of motion after bone union in the affected shoulder was not significantly different from that of the contralateral shoulder (p=0.69). Conclusion: The internal fixation achieved using precontoured locking compression plate in displaced clavicle shaft fracture showed effective bone union and can be considered as a reliable method with fine clinical results showing early range of motion at the shoulder joint.

ORTHODONTIC TREATMENT WITH MINISCREWS IN MIXED DENTITION (혼합치열기의 miniscrew를 이용한 교정치료)

  • Lim, Su-Min;Yang, Yeon-Mi;Kim, Jae-Gon;Baik, Byeong-Ju;Lee, Yong-Hun;Shin, Jeong-Geun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.367-375
    • /
    • 2008
  • Anchorage plays an important role in orthodontic treatment. Skeletal anchorage like the miniscrew is considered a more effective method in anchorage control than conventional anchorage which needs much patient's cooperation. The miniscrew offers many advantages. 1) It is easy to insert and to remove. 2) It can endure the force needed for moving teeth. 3) It can be immediately loaded and 4) Patient cooperation is not needed. 5) It is economic compared to other skeletal anchorage systems. In comparison to adult's bones, children's bones have comparatively poor bone quality and quantity. Therefore, it is hard to obtain primary stability in younger patients. However, if the miniscrew can be retained successfully, it will be effective in many orthodontic treatments. In these cases, we used the miniscrew in correcting of diastema, in aligning dental midline, and in rendering a forced eruption of impacted tooth in mixed dentition patient. We obtained satisfactory results.

  • PDF

Alternative Fixation Technique for Bony Bankart Lesion with Using Suture Anchor (봉합나사와 골터널을 이용한 골성 반카르트 병변의 고정)

  • Kim, Byung-Kook;Lee, Ho-Jae;Kim, Go-Tak;Dan, Jinmyoung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.574-578
    • /
    • 2019
  • For the treatment of a bony Bankart lesion accompanied by an acute traumatic shoulder dislocation, anatomical reduction and stable fixation of the bone fragment and glenohumeral ligament are essential to avoid chronic instability or degenerative changes. If the Bankart lesion has large bony pieces or comminuted fragments, it can be difficult to perform precise and secure fixation of the big intraarticular fragment to the fracture site because of the limited visualization of the arthroscopic procedure. In addition, in the case of the open procedure, it requires an extensive surgical dissection to access the fractured fragment, which may cause surgical approach-related morbidity, such as neurovascular complications, delayed subscapularis healing, and increased risk of stiffness. This paper describes an alternative open suture anchor technique for a large bony Bankart lesion, which was secured anatomically with squared knots after a shuttle relay through bony tunnels and adjacent soft tissue and labrum. This technique can achieve anatomical and firm fixation under direct vision, and reduce the number of surgery related morbidities.

Periodontal Regeneration Using the Mixture of Human Tooth-ash and Plaster of Paris in Dogs (성견에서 치아회분말과 연석고를 이용한 치주조직재생술)

  • Gu, Ha-Ra;Jang, Hyun-Seon;Kim, Su-Wan;Park, Joo-Cheol;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.1
    • /
    • pp.15-26
    • /
    • 2006
  • 흡수성 차페막을 이용한 조직 유도 재생술시 차폐막의 견고성으로 미루어 보아 재생을 위한 공간의 유지가 어려울 수 있다. 조직 유도 재생술과 함께 골이식술을 시행함으로써 공간 확보와 함께 적절한 혈병의 유지를 도모할 수 있고 이식된 골은 선생골 형성을 위한 핵으로 작용할 수도 있다. 최근에 사람의 치아회분말과 연석고를 혼합한 골이식재가 여러 연구를 통해 좋은 골이식재로 평가되었다. 본 연구에서는 성견 하악 소구치 2급 치근이개부위에 외과적으로 형성하여 흡수성 차폐막과 치아회분말-연석고 혼합 이식재를 이용한 조직유도재생 술을 시행하여 치주 조직 재생의 양상을 조직학적으로 관찰하고자 한다. 생후 12개월에서 16개윌 된 체중 15 Kg 내외의 성견 4마리를 이용하였다. 실험 재료로 생체흡수성 차폐막 (Biogide(R), Swiss) 를 사용하였고, 골이식재로 치아회분말-연석고를 혼합매식 하였다. 양측 상악 소구치 부위에 변연 치조골하방에 4 mm ${\times}$ 4 mm ${\times}$ 4 mm, (깊이 ${\times}$ 근원심 ${\times}$ 협설폭경) 깊이로 골내낭을 형성하였다. 형성된 골내낭의 기저부위 치근 표면에 1/4 round bur로 notch를 형성하여 참고점으로 하였다. 무작위로 선택된 한 쪽의 결손부를 대조군으로 오직 생체 흡수성 차폐막을 사용하였고, 실험군으로 치아회분말-연석고와 생체 흡수성 차폐막을 결손부로부터 2 mm 이상 덮을 수 있도록 다듬어 결손부 위에 위치시킨 후 협측 판막을 덮고 봉합하였다. 4주 후 2마리 ,8주 후 2마리를 희생시키고 통상의 방법으로 고정, 탈회, 포매의 과정을 거쳐 광학 현미경으로 검경하였다. 그 결과, 1. 4주 대조군에서 Bio-gide(R)는 완전한 흡수를 보였고, 치근이개부내에는 큰 공간이 존재하였다. 2. 4주 실험군에서 역시 Bio-gide(R)는 완전한 흡수를 보였고, 골 결손부내에 더 많은 신생골 관찰되었다. 그러나 아직까진 기존골과 신생골간에 명확한 차이가 있어서 쉽게 구분할 수 있었다. 또한 골이식재 주변으로 파골세포가 다수 관찰되며 이로 미루어 보아 활발한 골흡수가 일어남을 알 수 있었다. 3. 8주 대조군에서 결손부내에서는 기존골에 인접하여 신생골 형성이 부분적으로 일어났으나 연조직 침입이 관찰되었다. 4. 8주 실험군은 신생골이 기존골과 매우 유사한 형태로 관찰되었고, 신생골 형성 부위에 신생 혈관 증식이 관찰되었다. 또한 골내낭 기저부위에서는 백악질과, 치주인대가 재생됨이 관찰되었다. 이상의 결과에서 치아회분말-연석고 혼합매식은 골재생을 위한 골전도성이 있는 재료로 사료되며, 이를 이용히여 치주조직재생술시 흡수성 차폐막과 병행하여 사용한다면 더 많은 골재생이 있을 것으로 기대된다.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF