• Title/Summary/Keyword: 격리병동

Search Result 19, Processing Time 0.023 seconds

Patient Management to Improve the Efficiency of Infectious U-MAS System Design (전염성 환자관리의 효율성을 개선하기 위한 U-MAS 시스템 설계)

  • Shin, Yoon-Hwan;Shin, Ye-Ho;Ryu, Keun-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.9
    • /
    • pp.75-84
    • /
    • 2009
  • In this paper, the EPC Network as the most important technologies in the field of applied technology research and special attention to the use of RFID to better manage the disease in infected U-MAS (U-Medical Administrative Services) system was designed. U-MAS system, the Center for Disease Control in the illness, depending on the type of isolate and treat infected patients, recovery, discharge, isolation wards and intensive italian to manage and increase efficiency, manual and use a simple computer program improve the qualify of the current level, using RFID tags to improve the management of the patient everything that a little more and be out of the isolation ward, if competent disease management districts, such as the location to respond more quickly to facilitate the purpose is to contribute to. First, EPC Network and related technology for mobile RFID systems and related technology research. U-MAS system design offers. If you take advantage of the proposed U-MAS system for monitoring infectious disease patients and patients in the isolation ward, when the unauthorized departure location to shorten the time it takes to improve the effectiveness of disease management and present the elected effects was.

A Study on the Design Qualification of an Isolation Hospital According to Circulation System (동선계획에 따른 격리병동의 설계검증에 관한 연구)

  • Park, Hyun-Jin;Jung, Chung-Soo;Hong, Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.7
    • /
    • pp.520-527
    • /
    • 2011
  • Recently, Influenza(AI, PI) patients have been increasing rapidly. But, there is a lack of isolation hospitals. In particular, according to increase the rate of patients with airborne infection, in order to prevent the spread of pathogens, design of layout plan and air conditioning system of isolation hospitals becomes more important to maintain patient's room as negative pressure. In this study, the spread of pathogens are analyzed as room differential pressure, moving time of medical staff and patients, and moving way in isolation hospitals by multizone simulation; CONTAM 2.4. Through the analysis, the ways to improve isolation hospital considered at the design step are reached to prevent the spread of pathogens effectively. Also, it verifies that HVAC system for isolation hospital is suitably designed as standard.

A Design Methodology for the Temporary Isolation Room Based on the MERS-Cov Infection Control Guideline - In Case of Temporary Negative Pressure Isolation Room Using Shipping Container - (메르스 감염관리지침에 따른 감염병 임시 격리병동 계획방법에 관한 연구 - 컨테이너를 이용한 음압격리병동을 중심으로 -)

  • Lee, Sang-Hyun;Lee, Jin-Woo
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.33 no.12
    • /
    • pp.19-28
    • /
    • 2017
  • The purpose of this study is to propose a design methodology to build temporary isolation rooms when infectious diseases suddenly occur in a certain region, such as the case of MERS-Cov in South Korea in 2015. Although most big hospitals usually have isolation rooms, they are expensive and dangerous to run such facilities on normal and typical days. To deal with these problems in this research, shipping containers are chosen as devices used to build the temporary isolation rooms near the original hospital. To do so, firstly, a prototype for the temporary isolation room was designed with the three part modules. The first part is for the medical team; the second part including the isolation rooms is for patients; the third part is for medical selection rooms to test the specimens. Secondly, the plan was compared with the MERS-Cov infection control guidelines. Finally this prototype is applied into the Yong-in Yon-sei severance hospital and then evaluated through a CFD simulation using STAR-CCM+(ver.9.06) for checking infectious bacterium movement in this prototype. The result showed that the prototype is effectively safe for patients tested as negative, patients waiting to be tested, and the medical team.

A CFD Simulation Study on the Isolation Performance of a Isolation Ward (CFD를 이용한 격리병동의 격리성능 검토)

  • Sohn, Deokyoung;Kwon, Soonjung;Choi, Yunho
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.20 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • Purpose: In this study, we performed ventilation simulations for a standard isolation ward including three intensive care rooms, one anteroom(buffer room), and its recommended ventilation equipments. The purpose of this study is to predict outflow of pathogenic bacteria from patient breath to verify the reliability and the safety of the isolation ward. Methods: We suppose three scenarios of the movement of medical staff. The leakage of patient's breath to out of the ward is predicted in these scenarios using CFD simulations. Results: The patient's breath leakage rate to out of the ward in scenario 1 according to room air changes per hour(ACH : 6 and 12) is predicted to be 0.000057% and 0.00002%, respectively. The patient's breath leakage rate to out of the ward in scenario 2 according to room air changes(ACH : 6 and 12) is predicted to be 0.00063% and 0.00019%, respectively. The patient's breath leakage rate to out of the ward in scenario 3, which is the worst case(6 room air changes) is predicted to be 0.1%. Implications: Through the ventilation simulation like that in this study, the reliability and the safety on isolation performance of various plan of isolation ward are predicted quantitatively.

A Comparative study on Perceived Importance and Frequency of Core Nursing Skills between General and Special wards (일반병동과 특수병동의 핵심기본간호술에 대한 중요성인식과 수행 빈도 비교)

  • Chang, Eun-Hee;Mo, Moon-Hee;Choi, Eun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1264-1272
    • /
    • 2015
  • This study was performed to compare the perceived importance and performance frequency of the core nursing skills between general and special department. Subjects were 182 nurses who work on the hospital. Data was collected using items made by Korean accreditation board of nursing education and analyzed by frequency, mean and t-test. There were differences of importance and frequencies about nursing core skill between general and special wards. Core nursing skills of general wards were higher importance on intradermal injection(p=.011), transfusion(p=.028), simple catheterization(p=.047), cleansing enema(p=<.001), preoperative and postoperative care(p=.035), management administration(p=.027) and oxygenation with cannular(p=.002) than special wards. Actual performance frequency core nursing skills of general wards were higher similar on transfusion(p=.002), intermittent tube feeding(p=.032), simple catheterization(p=<.001), cleansing enema(p=<.001), preoperative care(p=.001), postoperative care(p=<.001), management administration(p=.001), protection equipment for quarantine room and waste disposal(p=.021), oxygenation with cannular(p=<.001) than special wards. It is needed to develop efficient and sequential program to learning the nursing core skills for nursing students.

A Study on the General Ward Planning Considering Conversion to Negative Pressured Isolation Unit (음압격리병실으로의 전환을 고려한 일반병동의 건축계획에 대한 연구)

  • Kwon, Soonjung;Kim, Jiyoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.3
    • /
    • pp.25-33
    • /
    • 2024
  • Purpose: As infectious diseases spread, hospitals have converted general wards into negative pressure isolation wards through remodeling. During the conversion process, there were limitations in converting the existing ward into an effective isolation ward due to its existing structure and mechanical system. To minimize these problems, this study proposes some general ward planning methods taking into account effective conversion to an infectious disease ward. Methods: Seven rapid conversion isolation wards have been analyzed in order to check their appropriateness as a negative pressured isolation unit. Then, general ward design planning methods that can minimize problems in rapidly converted negative pressured wards have been derived. Results: If general wards can be efficiently converted into negative pressure isolation wards, many isolation facilities can be secured effectively in a short period of time during a pandemic.

A Development of Design Guidelines for the Negative Pressured Isolation Units Controlling Severe Respiratory Infectious Disease (중증 호흡기 감염병 진료를 고려한 음압격리병동부의 건축계획)

  • Kwon, Soon Jung;Yoon, Hyungjin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.3
    • /
    • pp.45-56
    • /
    • 2016
  • Purpose: The MERS(Middle East Respiratory Syndrome) outbreaks in Korea highlighted dramatically the failings of traditional hospital environment for controlling or preventing infections among both patients and healthcare workers. MERS is transmitted by droplets that can be airborne over a limited area. The point should be emphasized that MERS in South Korea was predominantly a hospital-acquired (not a community-acquired) infection, because approximately 93% of MERS cases were resulted from exposure in hospital settings. This paper tries to suggest the design guidelines of negative pressured isolation ward for the sake of proper control of severe respiratory infectious diseases. Methods: Literature survey on the design guideline and regulations of airborne infection wards in Korea, Europe U.K. and CDC of U.S. have been carries out. 4 special infection wards in Hongkong, Germany, Japan and Korea have been surveyed in order to make the best use of the experiences related to facility design and operations. Results: Operating system influencing the facility design, space organizations of infectious ward including required space and zoning, and circulations of patients, staffs and materials are proposed. Implications: The results of this paper can be the basic data for the design of the airborne infection ward and relevant regulations. Afterwards in-depth study such as the development of space standards for the single bedroom, locker room and so on could be explored.

A study on the Types of Urgent Isolation Ward (긴급치료격리병동의 평면유형)

  • Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.61-69
    • /
    • 2022
  • Purpose: In response to the rapid spread of COVID-19 in 2020, the government supported facilities and equipment through the 'Urgent Isolation Ward Expansion Project'. Design and remodeling of efficient negative pressure isolation facilities had to be done in a short period of time, and the performance gap between facilities was very large because the types of hospitals and wards of existing medical facilities were diverse. In order to secure the stability of isolation wards between medical facilities and reduce the facility gap, guidelines for planning isolation wards considering the diversity of each hospital should be appropriately presented. In consideration of these points, this study aims to provide basic data for future remodeling guidelines for each plan type of the negative pressure isolation ward first. Methods: We analyzed the plans before and after the change of 13 case hospitals that performed the urgent care bed expansion project for COVID-19 confirmed patients. Before the remodeling, the current status of the facility was analyzed according to the type of corridor, the location of the nursing station, and the location of the elevator. After remodeling, the flow of medical staff and patients, the flow of entry and exit of clean and contaminated items, and the space of negative pressure and non-negative pressure areas. Results: The ward type was divided into three types according to the corridor type and room arrangement: double loaded corridor type with two side wards, race track type with one side ward, and race track type with two side wards. Based on these three types, the standard floor plan type of the isolation ward was proposed in terms of the location of the elevator bank and Nurse station. Implications: When the existing general ward is converted into a negative pressure isolation ward, this study can be a basic data to present customized guidelines for each ward type.

Space planning about Personal Protective Equipment(PPE) Doffing Area to reduce cross-infection among healthcare workers (의료진 교차감염을 낮추기 위한 음압격리병동 내 개인보호구 탈의구역의 공간구성)

  • Park, Doeun;Lee, hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.3
    • /
    • pp.37-44
    • /
    • 2023
  • Purpose: To decrease cross-infection, it's essential to analyze the spatial composition of the 'PPE doffing area'. Instead of solely relying on manpower standards, we should focus on responding to infectious diseases within the context of space planning. By doing so, we can lower the risk for healthcare workers' infection and ensure a level of safety in various environmental changes or new manpower input situations. Methods: This analysis is conducted specifically for facilities with negative pressure isolation wards. Additionally, interview surveys to obtain feedback from healthcare workers and incorporate their expertise into the design of the 'PPE doffing area' have been carried. Results: In a PPE doffing area, the standard spaces include a PPE doffing room, a shower room, and a clothing room. Depending on the facility environment or the level of infectious diseases, a Decontamination room or Anteroom can be optionally added. Healthcare workers who remove their PPE in the PPE doffing room should avoid re-entering the Negative pressure room. The shower room is often underutilized. When planning for a future PPE doffing area, an aisle space or passageway must be included even if a shower room is planned. Implications: This study examined the space used by healthcare workers rather than patients, with a focus on infection prevention through architectural planning rather than individual efforts. However, the investigation was limited to facilities that have been converted from general wards to negative pressure isolation wards, so it cannot be generalized to all infectious disease facilities.

Perceived Anxiety and Uncertainty in Hematopoietic Stem Cell Transplantation Recipients to and from Isolation Unit (격리병동 입.퇴실시 조혈모세포 이식 환자가 지각하는 불안과 불확실성)

  • Kim, Hye-Jo;Choi, Dong-Won;Park, Ho-Ran;Sohng, Kyeong-Yae
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.13 no.3
    • /
    • pp.428-436
    • /
    • 2006
  • Purpose: To investigate the levels of uncertainty and anxiety at admission and discharge to the isolation unit for patients undergoing hematopoietic stem cell transplantation (HSCT). Method: The data were collected from 60 patients who were admitted to the department of HSCT. Uncertainty and anxiety were assessed using the Mishel Uncertainty in Illness Scale (MUIS) and Anxiety Inventory (STAI). Collected data were analyzed using the SAS program. Results: The mean score for anxiety at admission was 2.20, and at discharge 2.10. The mean score for uncertainty at admission was 2.19, and at discharge 2.07. The anxiety at admission the group with physical discomfort was higher than that of group without physical discomfort. A positive relationship was found between anxiety and uncertainty at admission and at discharge. The major variables were expectation for cure and physical discomfort, explaining 25.87% of the anxiety at admission. The major variable was expectation for cure, explaining 20.94% of the uncertainty at admission. Conclusion: Front the above results, it can be concluded that support and consideration are required to reduce anxiety of the inpatient in single room.

  • PDF