• Title/Summary/Keyword: 검출한계

Search Result 1,546, Processing Time 0.033 seconds

Algorithm Development and Experimental Verification of Acoustic Emission First-arrival-time Determination for the Source Location (정확한 미소파괴음의 발생위치 분석을 위한 신호 도달시간 결정 알고리즘 연구 및 실험적 검증)

  • Jang, Hyun-Sic;Choi, Jun-Young;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.587-598
    • /
    • 2015
  • We examined various existing threshold methods for the determination of the first arrival time of acoustic emission (AE), and developed a new variable threshold method that could determine the first arrival time of AE more accurately and more quickly than existing methods. The new method, a modification of an existing threshold method, does not fix the threshold, but applies variable thresholds for the AE signals according to noise analysis. Two- and three-dimensional models were established to test the effectiveness of the new method. It could determine source locations of AE in a two-dimensional model 38.3% more accurately than the pre-existing threshold methods. Its accuracy improvement over the existing methods in a three-dimensional model was about 15.2%. A practical test involved measuring the source locations of AE during three-point bending tests of granite cores. The new method placed the sources closer to the fracture plane than did the pre-existing methods, indicating its superior (and quicker) ability to determine the source locations of AE.

Determination of Minimum Detectable Activity in Environmental Samples (환경방사능 측정에서의 검출한계치의 정량적 고찰 및 최소검출방사능 농도 계산)

  • Lee, Myung-Ho;Shin, Hyun-Sang;Hong, Kwang-Hee;Cho, Young-Hyun;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.171-184
    • /
    • 1999
  • In this paper, using statistical theory the basic concepts and the formulars of lower limit of detection were deasribed. Assuming that risks of 5% are acceptable (95% confidence level), lower limits of detection were calculated on the measuring apparatus for alpha, beta and gamma nuclides. Also, on the basis concepts of lower limit of detection, the MDA values were calculated for the radionuclides detected easily in the environment. These results make it possible to evaluate confidence limits on the radioanalytical results in the environmental sample.

  • PDF

Environmental Behavior of Fenarimol, Chlorothalonil, and Ethoprophos in Agroforesty Field (산림농업지대에서 fenarimol, chlorothalonil 그리고 ethoprophos의 행방)

  • Kim, Eun-Hyeok;Cho, Ki-Young;Cho, Jae-Young
    • Journal of Applied Biological Chemistry
    • /
    • v.57 no.4
    • /
    • pp.341-345
    • /
    • 2014
  • Fate of fenarimol, chlorothalinol, and ethoprophos sprayed to control disease and pest was studied in a agroforest culture field of Jangsu-gun, Jeollabuk-do, Korea. Concentrations of fenarimol, chlorothalinol, and ethoprophos in runoff water ranged mostly to 0.2 mg/L at the first rainfall-runoff event. And then was rapidly decreased than detection limit at 60 days after the application. The fenarimol and chlorothalonil residue in soil was dissipated to below detection limit at 30 days after the application. But ethoprophos was decreased to below detection limit at 135 days after the application. The concentrations of experimental pesticides were highly detected in agroforest culture field than in open culture field. It is assumed that experimental pesticides were strongly adsorbed by organic matter such as fulvic acid and humic acid.

Real-time PCR assay for the Detection of Toxoplasma gondii in Retail Meats: Proof-of-concept Study (유통식육에서의 톡소포자충 검출을 위한 유전자검사법 개발)

  • Yun, Han Seong;Suh, Soo Hwan;Kwak, Hyo-Sun;Joo, In-Sun
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.3
    • /
    • pp.199-205
    • /
    • 2017
  • Although many PCR-based assays have been developed, the majority of rapid detection of Toxoplasma gondii in animal and their meat product has been dependent on immunogenic assays. Thus, there is still a need for more reliable PCR based detection method for T. gondii in retail meats. Recently, a 529-bp repeat element that exists in 200-300 copies per genome of T. gondii genome had been spotlighted for its usefulness as potential detection targers. In this study, the 529-bp repeat element was selected for real-time PCR to detect three types of T. gondii (type I, II and III). A primer pair targeting 82-bp of the 529-bp element detected all three types of T. gondii and showed high level of specificity against 14 different food-borne pathogens as well as 3 protozoan parasites such as Giardia lamblia, Cryptosporidium parvum and Entamoeba histolytica. Application of the new real-time PCR assay in meat samples showed improved detection sensitivity compared to the B1-gene targeted method suggesting potential new target for Toxoplasma gondii screening in retail meats.

Analysis of gibberellic acid from fruits using HPLC/UV-vis (HPLC/UV-vis을 이용한 과일류 중의 지베렐린 산 분석)

  • Ma, Kyung Na;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.19-26
    • /
    • 2013
  • Gibberllic acid ($GA_3$) is one of gibberellins (GAs) that are a class of plant growth hormones that exert profound and diverse effects on plant growth and development. $GA_3$ is essentially non-UV absorbing and is difficult to assay by UV-detector. For effective extraction of gibberellic acid from fruits by using liquid-liquid extraction, optimized pH and extraction solvent were established. The selective and sensitive derivative of $GA_3$ for HPLC/UV-vis was derivatized using phenacyl bromide, and the experimental factors, including reaction time, reaction temperature and amount of derivatizing reagent and base were investigated for the effective synthesis. The derivatized $GA_3$ with phenacyl bromide was effectively analyzed by HPLC/UV-vis. The structure of derivatized $GA_3$ was confirmed by HPLC/ESI-MS. For apple, LOD and LOQ were 0.008 mg/kg and 0.027 mg/kg, respectively. For pear, LOD and LOQ were 0.003 mg/kg, 0.012 mg/kg, respectively. The established method can be applied to more effective analysis of $GA_3$ from plant and food.

Characterization of Atomic Emission Detector for Gas Chromatography Using Cylindrical Microwave Cavity (원통형 Microwave Cavity를 이용한 기체크로마토그라프 원자발광 검출기의 특성에 관한 연구)

  • Park, Young-Joo;Yoo, Hee-Soo
    • Analytical Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.263-268
    • /
    • 1992
  • A plasma source with cylindrical microwave cavity was used as atomic emission detector for gas chromatography. Detection limits of several elements were determined for this system. Detection limits for bromine and sulfur were 0.46 pg/s and 0.51 ng/s, respectively. The plasma was stable at the range of flow rate of 10 to 20mL/min.

  • PDF

Some Improvements of Gamma-ray Measurement for the Determination of the Boron Content (붕소 함량결정을 위한 즉발 감마선 계측법의 개선)

  • Nak Bae Kim;Hae-Ill Bak
    • Nuclear Engineering and Technology
    • /
    • v.16 no.1
    • /
    • pp.18-20
    • /
    • 1984
  • The detection limit of boron has been lowered further in the capture gamma-ray measurement after preconcentration of boron by placing natural lithium brick in front of Ge(Li) detector. The experimental detection limit is found to be 0.30ppm, 0.18ppm, 0.045ppm and 0.090ppm for the samples of aluminum, steel, uranium dioxide and graphite, respectively. An alternate counting technique kas been also used for neglecting the error caused by the fluctuation of neutron flux during counting.

  • PDF