• Title/Summary/Keyword: 검출기

Search Result 4,882, Processing Time 0.047 seconds

UWB Automobile Short Range Radar Receivers Performance In a Log-Normal Clutter Background (Log-Normal Clutter 환경에서 차량용 UWB 단거리 레이더 수신기의 성능분석)

  • Kumaravelu, Nandeeshkumar;Ko, Seok-Jun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.9
    • /
    • pp.59-64
    • /
    • 2011
  • Ultra wideband radars attract considerable attention as a short range automotive radar because of its high range resolution. Radar signal reflected from a target often contains unwanted echoes called as clutter, so the detection of target is difficult due to clutter echoes. Therefore, it is important to investigate the radar detector for better detecting from the reflected signals. In this paper, the optimal detector is obtained for various mean and variance value in log-normal clutter environment. The types of non-coherent detectors used are square law detector, linear detector, and logarithmic detector. The performances of detectors are compared in log normal clutter environment and the suitable detector is determined for automotive short range radar application.

A Study on Multiuser Detector for MC-DS/CDMA System (MC-DS/CDMA 시스템을 위한 다중 사용자 검출에 관한 연구)

  • 우대호;조남현;장병건;윤태성;변윤식
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.919-922
    • /
    • 2001
  • 다중 반송파를 사용하는 직접 확산 코드 분할 다중 접속 방식에서는 다중 사용자들에 의해서 시스템의 성능에 영향을 미치는 문제인 다중 사용자 간섭이 발생된다. 이 문제를 해결하기 위해서 사용된 기법이 다중 사용자 검출이다. 기존 방안으로 부공간 최소 평균 제곱 에러 다중 사용자 검출기가 존재한다. 이 검출기는 정확한 타이밍과 채널에 대한 정보가 필요하다. 이에 이점을 극복하기 위해서 부공간 MMSE 구조에 적응 구조를 더하여 검출 능력을 향상 시키고자 하였다. 모의 실험 결과 제안된 검출기가 기존 검출기 보다 BER 10/sup -3/ 기준에서 약 0.5[dB]의 신호대 잡음 이득을 얻을 수 있음을 나타내고 있다. 따라서 제안된 검출기가 기존 검출기보다 더 나은 성능을 지니고 있음을 알 수 있다.

  • PDF

Evaluation of the Small Field of for the Detector Type Medical Linear Accelerator (의료용 선형가속기의 소조사면에 대한 검출기 종류에 따른 평가)

  • Lee, Dong-Woon;Jung, Kang-Kyo;Shin, Gwi-Soon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.177-184
    • /
    • 2016
  • Recently linear accelerator of radiation therapy intensity modulated radiation therapy, stereotactic radiation therapy are widely used. Such radiation treatment techniques are generally difficult to exclude the small field by using the inverse treatment plan. It is necessary to dose an accurate measurement of characteristics of the small field. Thus, using different detectors to measure the volume of the effective percentage depth dose, beam profile, and the output factor of the small field was to evaluate the dose characteristics of each detector. Experimental results for the X-ray beam 6 MV energy beam quality($PDD_{20}/PDD_{10}$) is $10{\times}10cm^2$ Diode detector is as high as 2.4% compared to Pinpoint detector. All field size to lesser effective volume of Diode detector shows that it is far better than other detectors by more than 50% of small penumbra, therefore spatial resolution far excellent. In field size $2{\times}2cm^2$ Semiflex detector was measured about 2% less than the other detector. Field size $1{\times}1cm^2$ is that there is no judgment about the validity show the difference between 20%. Field size $1{\times}1cm^2$ from the measured values of the Diode detector and Pinpoint detector showed a 13% difference. Less than field size $3{\times}3cm^2$ the feed to the difference between the output factor of the effective volume of the detector to be used for the effective volume available to the detector.

A Study for Analysis of Image Quality Based on the CZT and NaI Detector according to Physical Change in Monte Carlo Simulation (CZT와 NaI 검출기 물질 기반 물리적 변화에 따른 영상의 질 분석에 관한 연구: 몬테카를로 시뮬레이션)

  • Ko, Hye-Rim;Yoo, Yu-Ri;Park, Chan-Rok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.741-748
    • /
    • 2021
  • In this study, we evaluated image quality by changing collimator length and detector thickness using the Geant4 Application for Tomographic Emission (GATE) simulation tool. The gamma camera based on the Cadimium Zinc Telluride (CZT) and NaI detectors is modeled. In addition the images were acquired by setting 1, 2, 3, 4, 5, and 6 cm collimator length and 1, 3, 5, and 7 mm detector thickness using point source and phantom, which is designed by each diameter (4.45, 3.80, 3.15, 2.55 mm) with 447, 382, 317, and 256 Bq. The sensitivity (cps/MBq) for point source, and signal to noise ratio (SNR) and profile for phantom at the 4.45 mm by drwan the region of interests were used for quantitative analysis. Based on the results, the sensitivity according to collimator length is 2.3 ~ 48.6 cps/MBq for CZT detector, and 1.8 ~ 43.9 cps/MBq for NaI detector. The SNR using phantom is 3.6~9.8 for CZT detector, and 2.9~9.5 for NaI detector. As the collimator length is increased, the image resolution is also improved according to profile results based on the CZT and NaI detector. In addition, the senistivity for detector thickness is 0.04 ~ 0.12 cps/MBq for CZT detector, and 0.03 ~ 0.11 cps/MBq. The SNR using phnatom is 7.3~9.8 count for CZT detector, and 5.9~9.5 for NaI detector. As the detector thickness is increased, the image resolution is decreased according to profile results based on the CZT and NaI detector due to scatter ray. In conclusion, we need to set the geometric material such as detector and collimator to acuquire suitable image quality in nuclear medicine.

A Study on the Validation of Effective Angle of Particle Deposition according to the Detection Efficiency of High-purity Germanium Gamma-ray Detector (고순도 저마늄 감마선 검출기의 검출효율에 따른 유효입체각 검증에 관한 연구)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.487-494
    • /
    • 2020
  • The distance between the source and the detector, the diameter of the detector, and the volume effect of the radiation source result in a change in solid angle at the detector entrance, which affects the determination of detection efficiency by causing a difference in path length within the detector. A typical analysis method for calculating solid angles was useful only for a source (60Co) with a simple geometric structure, so in this experiment, the distance between the detector and the source was measured by switching on for up to 25 cm with the reference point of window cap 0.5 cm. In addition, 450 and 1000 ㎖ Marinelli beaker of standard volumetric sources were closely adhered to the detector. For circular point sources co-axial with the detector, the change in the solid angle to the distance from the detector window is equal to half the square radius of the source versus the square radius of the detector, if the resulting relationship of the calculation analysis results in the detector being less than the radius of the source. Since the solid angular difference is 0.5 the result of Monte Carlo is acceptable. The relationship between detector and source distance is shown. Solid angles have been verified to decrease rapidly with distance. Measurement and simulation results for a volumetric source show a difference of ±1.01% from a distance of 0 cm and less than 4 % when the distance is reduced to 5 and 10 cm. It can be seen that the longer distance, the smaller efficiency angle, and the exponential increase in attenuation as the energy decreases, is reflected in the calculation of efficiency. Thus, the detection efficiency has proved sufficient for the use of solid angle and Monte Carlo codes.

Novel control scheme for the absence of the thermoelectric(TEC) of infrared detector in an Uncooled thermal system (비냉각 열상시스템에서의 적외선 검출기의 열전소자(TEC) 부재에 대한 효율적인 제어기법)

  • Kim, Yong-Jin;Seo, Jae-Gil;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2335-2340
    • /
    • 2012
  • The detector is an uncooled detector system that functions inside the thermoelectric cooler (TEC) equipped with features instead of the cooler. The function of the thermoelectric device to control the temperature of the detector based on a function of temperature to prevent degradation of image quality to perform the role, the latest technology trend by removing the thermoelectric device size, cost a lot of effort to reduce has been studied. In this paper, It would be proposed of the actual test result using real chamber environment of for the best TECless algorithm as to minimize the degradation of image quality and obtain the low price of the uncooled detector.

Development of Control System for Thimble Handling Equipment for Neutron Flux Mapping (노내 핵계측 검출기 안내관 인출 및 삽입 장비 제어시스템의 개발)

  • Byun, Seung-Hyun;Cho, Byung-Hak;Park, Joon-Young;Lee, Jae-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1995-1996
    • /
    • 2006
  • 검출기 안내관은 노내 핵계측 계통의 중성자 분포 측정을 위한 이동형 검출기의 이동경로를 제공할 뿐만 아니라 원자로 냉각수 계통의 압력경계를 유지하는 안전성 등급의 중요한 설비이다. 그러나, 인출과 삽입을 위한 검출기 안내관 취급은 의외로 낙후되어 작업자의 인력에만 의존하고 있는 실정이며, 원자로 격납용기 내부에 위치한 고방사선 지역에서 작업이 수행되고 있는 실정이다. 따라서 노내 핵계측 계통의 검출기 안내관의 안정적인 관리를 위해 검출기 안내판을 일정한 힘으로 인출하고 삽입할 수 있는 자동화시스템의 개발이 이루어지고 있다. 전력연구원에서 개발한 안내관 취급기구는 롤러에 의해 안내관을 파지하고, DC 모터 구동에 의해 안내관을 인출하고 삽입하는데, 본 논문에서는 안내관 취급 기구의 제어 시스템 구성과, 롤러와 안내관 사이에 발생하는 슬립을 고려한 제어기 구조를 제안하고, 실험을 통해 구현한 제어 시스템의 효용성을 보인다.

  • PDF

Low-Power ECG Detector and ADC for Implantable Cardiac Pacemakers (이식형 심장 박동 조율기를 위한 저전력 심전도 검출기와 아날로그-디지털 변환기)

  • Min, Young-Jae;Kim, Tae-Geun;Kim, Soo-Won
    • Journal of IKEEE
    • /
    • v.13 no.1
    • /
    • pp.77-86
    • /
    • 2009
  • A wavelet Electrocardiogram(ECG) detector and its analog-to-digital converter(ADC) for low-power implantable cardiac pacemakers are presented in this paper. The proposed wavelet-based ECG detector consists of a wavelet decomposer with wavelet filter banks, a QRS complex detector of hypothesis testing with wavelet-demodulated ECG signals, and a noise detector with zero-crossing points. To achieve high-detection performance with low-power consumption, the multi-scaled product algorithm and soft-threshold algorithm are efficiently exploited. To further reduce the power dissipation, a low-power ADC, which is based on a Successive Approximation Register(SAR) architecture with an on/off-time controlled comparator and passive sample and hold, is also presented. Our algorithmic and architectural level approaches are implemented and fabricated in standard $0.35{\mu}m$ CMOS technology. The testchip shows a good detection accuracy of 99.32% and very low-power consumption of $19.02{\mu}W$ with 3-V supply voltage.

  • PDF

구부린 완전결정을 이용한 중성자 단색기의 특성평가

  • 김신애;최용남;김성규;김성백;문명국;홍광표;최병훈;최영현;이창희
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2003.05a
    • /
    • pp.23-23
    • /
    • 2003
  • Cu 단결정과 다결정 Cu 막대(rod)를 시료로 하여 구부린 완전결정(bent perfect crystal, BPC)을 이용한 중성자 단색기의 특성을 평가함으로써 단결정 회절 및 집합조직 측정장치인 4축 단결정 회절장치(FCD)에 BPC 단색기를 적용할 수 있는지 시험하였다. 측정은 한국원자력연구소의 연구용 원자로인 하나로의 571 수평공에 구성된 test station에서 수행하였다. 단색기와 시료 사이의 거리는 3000mm, 시료와 검출기 사이는 600mm, 단색화빔 인출각도(2θ/sub M/)는 44.6°로 고정하여 FCD와 거의 같은 배치를 구현하였다 직사빔의 단면분포와 강도는 저효율 2차원 위치민감형 검출기(2-D PSD)를 이용하여 확인하였다. 이 검출기는 검출면적 90x90㎟, 공간 분해능 1.2mm, 검출효율 약 1%인 저효율 검출기이다. 회절빔은 검출면적 190x190㎟, 검출효율은 1Å에서 60%인 고효율 2-D PSD를 이용하여 측정하였다. Cu 단결정 측정에 사용한 ePC 단색화 결정은 200×40×3.4㎣ 크기의 Si(220) 슬랩이며, 비대칭 기하로 Si(331)면을 사용하여 파장 λ=0.954Å으로 중성자빔을 단색화시켰다. BPC-Si를 구부려 슬랩의 곡률반경을 변화시키면서 단색기-시료-검출기가 평행배치일 때 Cu(200), (220), (400), (420)면의 rocking curve를 측정하여 각 조건에서의 분해능과 강도를 평가하였다. BPC 단색기를 집합조직 측정에 적용할 수 있는지 시험하기 위하여 다결정 Cu 막대(직경 4.5mm, 길이 18mm)를 시료로 선택하였다. 207x30x3.0㎣ 크기의 Si 슬랩을 단색화 결정으로 사용하였다. 이 슬랩은 다양한 결정면을 이용한 특별한 기하를 구현할 수 있도록 Si(111)면에서 10° 벗어난 면을 절단한 것이다. 비대칭 기하로 Si(311)면을 사용하여 파장 λ=1.253Å의 단색화된 중성자빔으로 측정하였다 BPC-Si를 구부려 슬랩의 곡률반경을 변화시키면서 단색기-시료-검출기가 평행파 반평행배치일 때 Cu(111), (200), (220), (311), (331), (420)면의 회절선을 측정하여 각 조건에서 분해능과 강도를 평가하였다.

  • PDF

Structure Parameters for High Speed and High efficiency Waveguide Photodetectors integrated with passive optical waveguides (수동 광도파로를 집적한 고효율 도파로 광 검출기 구조에 대한 해석)

  • Cho, Won;Hyun, Kyung-Sook
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.176-177
    • /
    • 2003
  • 초고속,대용량,유-무선 통합 등의 광 통신 시스템 발전 요구에 따라 광 검출기는 점점 더 초고속,고출력의 사양을 요구 받고 있다. 기존 광소자의 일반적인 광 검출기구조에서는 속도와 효율이 서로 상반되어,40GHz이상의 속도와 고효율을 모두 얻기가 매우 어려우므로, 이를 해결하기 위하여 수동 광도파로가 집적된 광 검출기가 필요하다. 도파로형 광 검출기는 일반적으로 잘 알려져 있는 구조이지만 입사광을 수용하고, 광의 크기를 조절하여 광 흡수층에 제대로 전달하기 위해서는 광 도파로 및 구조에 대한 연구가 필요하다. (중략)

  • PDF