Design a Four Layer Depth-Encoding Detector Using Quasi-Block Scintillator for High Resolution and Sensitivity (고분해능 및 고민감도를 위한 준 블록 섬광체를 사용한 네 층의 반응 깊이 측정 검출기 설계)

  • Seung-Jae Lee;Byungdu Jo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.65-71
    • /
    • 2024
  • To achieve high resolution and sensitivity of positron emission tomography (PET) for small animals, the detector is constructed using very thin and long scintillation pixels. Due to the structure of these scintillation pixels, spatial resolution deterioration occurs outside the system's field of view. To solve this problem, we designed a detector that could improve spatial resolution by measuring the interaction depth and improve sensitivity by using a quasi-block scintillator. A quasi-block scintillator size of 12.6 mm x 12.6 mm x 3 mm was arranged in four layers, and optical sensors were placed on all sides to collect light generated by the interaction between gamma rays and the scintillator. DETECT2000 simulation was performed to evaluate the performance of the designed detector. Flood images were acquired by generating gamma-ray events at 1 mm intervals from 1.3 mm to 11.3 mm within the scintillator of each layer. The spatial resolution and peak-to-peak distance for each location were measured in an 11 x 11 array of flood images. The average measured spatial resolution was 0.25 mm, and the average distance between peaks was 1.0 mm. Through this, it was confirmed that all locations were separated from each other. In addition, because the light signals of all layers were measured separately from each other, the layer of the scintillator that interacted with the gamma rays could be completely separated. When the designed detector is used as a detector in a PET system for small animals, it is considered that excellent spatial resolution and sensitivity can be achieved and image quality can be improved.

Response Function of HPGe Detector using $^{23}Na$(p, $\gamma$)$^{24}Mg$ and $^{27}Al$(p, $\gamma$)$^{28}Si$ Reaction ($^{23}Na$(p, $\gamma$)$^{24}Mg$$^{27}Al$(p, $\gamma$)$^{28}Si$반응을 이용한 HPGe 검출기의 응답함수)

  • Park, Sang-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.85-90
    • /
    • 2010
  • In the present work, peak relative efficiency for the energy was obtained and response function was worked out. This study was carried out using the high resolution high efficiency HPGe detector(diameter 78.7 mm, length 86.5 mm) and NaI(Tl) detector for anti-compton. The anti-coincidence of the signals from the two detectors could be used to lessen the Compton effect signal; thus, the $\gamma$-ray energy resolution could be improved. The $\gamma$-ray spectrum was measured at $55^{\circ}$ to the direction of the incident proton beam. Reaction spectrum was obtained from the $^{23}Na$(p, $\gamma$)$^{24}Mg$ reaction at $E_p$ = 1424 keV and $^{27}Al$(p, $\gamma$)$^{28}Si$ reaction at $E_p$ = 992 keV. To accelerate the incident proton which creates the (p, $\gamma$) capture reaction, the 3 MeV Pelletron accelerator at the Tokyo Institute of Technology was used. Response function was worked out by a noble technique. We worked out a response function from 1.2 to 9.4 MeV at intervals of 0.75 MeV.

Design of a Depth Encoding Detector using Light Guides with Different Reflector Patterns for Each Layer (각 층별 반사체 패턴이 서로 다른 광가이드를 사용한 반응 깊이 측정 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.31-36
    • /
    • 2023
  • Among imaging and treatment devices for small animals, positron emission tomography(PET) causes a change in spatial resolution within a field of view. This is a phenomenon caused by using a small gantry and a thin and long scintillation pixel, and detectors that measure the interaction depth are being developed and researched to solve this problem. In this study, a detector that measures the interaction depth was designed using several scintillator blocks and light guides with different reflector patterns. The scintillator block composed of 4 × 4 arrays of 3 mm × 3 mm × 5 mm scintillation pixels formed four layers, and a light guide was inserted in each layer to configure the entire detector. In order to check whether the interaction depth was measured, a gamma ray interaction was generated at the center of all scintillation pixels to acquire data and then reconstructed into a flood image. The reflector patterns of the light guides inserted between the layers were all different, so the positions of the scintillation pixels for each layer were formed in different locations. It is considered that even spatial resolution can be achieved over all regions of the field of view if all positions of the scintillation pixels thus formed are separated and used for image reconstruction.

The development of conductive 10B thin film for neutron monitoring (중성자 모니터링을 위한 전도성 10B 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Jung, Yongju;Choi, Young-Hyun;Baek, Cheol-Ha;Moon, Myung-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.199-205
    • /
    • 2014
  • In the field of neutron detections, $^3He$ gas, the so-called "the gold standard," is the most widely used material for neutron detections because of its high efficiency in neutron capturing. However, from variable causes since early 2009, $^3He$ is being depleted, which has maintained an upward pressure on its cost. For this reason, the demands for $^3He$ replacements are rising sharply. Research into neutron converting materials, which has not been used well due to a neutron detection efficiency lower than the efficiency of $^3He$, although it can be chosen for use in a neutron detector, has been highlighted again. $^{10}B$, which is one of the $^3He$ replacements, such as $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$, is being researched by various detector development groups owing to a number of advantages such as easy gamma-ray discrimination, non-toxicity, low cost, etc. One of the possible techniques for the detection is an indirect neutron detection method measuring secondary radiation generated by interactions between neutrons and $^{10}B$. Because of the mean free path of alpha particle from interactions that are very short in a solid material, the thickness of $^{10}B$ should be thin. Therefore, to increase the neutron detection efficiency, it is important to make a $^{10}B$ thin film. In this study, we fabricated a $^{10}B$ thin film that is about 60 um in thickness for neutron detection using well-known technology for the manufacturing of a thin electrode for use in lithium ion batteries. In addition, by performing simple physical tests on the conductivity, dispersion, adhesion, and flexibility, we confirmed that the physical characteristics of the fabricated $^{10}B$ thin film are good. Using the fabricated $^{10}B$ thin film, we made a proportional counter for neutron monitoring and measured the neutron pulse height spectrum at a neutron facility at KAERI. Furthermore, we calculated using the Monte Carlo simulation the change of neutron detection efficiency according to the number of thin film layers. In conclusion, we suggest a fabrication method of a $^{10}B$ thin film using the technology used in making a thin electrode of lithium ion batteries and made the $^{10}B$ thin film for neutron detection using suggested method.

A study on the derivatization technique for tamoxifen metabolites in human urine by gas chromatography/mass spectrometry (기체크로마토그래피/질량분석기를 이용한 인체 내 뇨시료에서의 Tamoxifen 대사체 검출을 위한 유도체화 연구)

  • Kim, Yunje;Lee, Yoonjung
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.322-336
    • /
    • 2004
  • The improved derivatization technique of tamoxifen metabolite in human urine is described for the acylation method that they are substituted by derivatization reagent like acyl anhydride for use of gas chromatography/mass spectrometry. The hydroxyl group of tamoxifen metabolite was derivatized by trifluoroacetic anhydride (TFAA), pentafluoroacetic anhydride (PFPA) and heptaflorobutylic anhydride (HFBA). It was investigated to the gas chromatography/mass spectrometry (GC/MS) technique use negative ion chemical ionization (NCI), positive ion chemical ionization (PCI) and electron impact (EI). In acylation of the metabolites of tamoxifen, the effective reaction temperature and time were shown to be at $50^{\circ}C$ for 30 min. The 4-hydroxytamoxifen, which is known to major metabolite of tamoxifen, was not detected in human urine, whileas the hydroxymethoxytamoxifen was detected. We thought that this result was from the single dose of tamoxifen.

Degradation of Sulfonamide Antibiotic Substances by Ozonation: An Experimental and Computational Approach (설폰아미드계 항생물질의 오존산화분해에 대한 계산화학적 해석 및 실험적 검증)

  • Won, Jung Sik;Lim, Dong Hee;Seo, Gyu Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.442-450
    • /
    • 2014
  • Concern has grown over a presence of micropollutants in natural water since sulfonamide antibiotic substances such as sulfamethazine, sulfamethoxazole, sulfathiazole have been frequently detected in Nakdong River, Korea. The current work investigates the degradation of the three sulfonamide substances by using quantum chemistry calculations of density functional theory (DFT) and experimental measurement techniques of Fourier transform infrared spectroscopy (FT-IR) and ultraviolet-visible spectrophotometer (UV-VIS). DFT calculations demonstrate that the lowest energy gap between the highest occupied molecular orbital (HOMO) and the lowest unoccupied molecular orbitals (LUMO) lies in sulfanilamide functional group of sulfonamide, implying that the sulfanilamide functional group would be the most active site for ozone oxidation. Also, UV-VIS spectra and FT-IR analysis reveal that 260 nm band originated from sulfanilamide group was absent after ozone oxidation, indicating that a functional group of amine (N-H) was removed from sulfanilamide. Both theoretical and experimental observations agree well with each other, demonstrating the DFT calculation tool can be an alternative tool for the prediction of chemical reactions in purification treatment processes.

Thermophilic Hydrogen Production from Microbial Consortia Using PVDF Membrane Bioreactor (PVDF 여과막 생물막 반응기를 이용한 혐기 세균 복합체의 고온 수소생산)

  • Oh, You-Kwan;Lee, Dong-Yeol;Kim, Mi-Sun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.3
    • /
    • pp.223-229
    • /
    • 2007
  • 여과막 생물반응기를 이용하여 $60^{\circ}C$에서 혐기 세균 복합체가 포도당으로부터 수소를 생산할 수 있는 최적조건을 연구하였다. 여과막 생물반응기는 연속교반 탱크반응기와 외부에 장착된 PVDF (polyvinylidene fluoride) 중공사막 여과장치로 구성되었다. 접종슬러지는 하수처리장 소화 슬러지조에서 얻었고, 포자형성 수소생산 미생물을 얻기 위해 $90^{\circ}C$에서 20분 간 열처리하였다. 16S rRNA PCR-DGGE(polymer chain reaction-denaturing gradient gel electrophoresis) 분석을 통해 열처리 전후의 미생물상 변화를 조사하였다. 열처리 후 DGGE 밴드의 수는 감소하였고, 주요 밴드는 Clostridium perfringens와 유사한 염기서열을 나타내었다. 운전 기간 동안 바이오가스 내 수소함량은 60%(v/v)를 유지하였고, 메탄은 검출되지 않았다. 연속교반 탱크반응기를 여과막 없이 수력학적 체류 4시간에서 운전하였을 때 공급된 포도당의 95.0%가 제거되었고, 이때 균체농도 및 수소생산속도는 각각 1.35 g cell/L 및 7.4 L $H_2$/L/day이었다. 동일한 체류시간에서 PVDF중공사막 여과장치를 장착하여 연속교반 탱크반응기를 운전하였을 때, 균체농도는 1.62 g cel/L로 증가하였고 높은 포도당 제거율(99.5%) 및 수소생산속도(8.8 L $H_2$/L/day)가 관찰되었다. 40 nm 및 100 nm의 공극크기를 가진 여과막은 균체농도 및 수소생산 측면에서 유사한 성능을 나타내었다. 여과막 생물반응기는 여과막의 반복적인 세척을 통해 30일 이상 안정적으로 운전될 수 있었다.

A 145 GHz Imaging Detector Based on 65-nm RFCMOS Technology (65-nm RFCMOS공정 기반 145 GHz 이미징 검출기)

  • Yoon, Daekeun;Kim, Namhyung;Kim, Dong-Hyun;Rieh, Jae-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1027-1033
    • /
    • 2013
  • In this work, a D-band imaging detector has been developed in a 65-nm CMOS technology for high frequency imaging application. The circuit was designed based on the resistive self-mixing of MOSFET devices. The fabricated detector exhibits a maximum responsivity of 400 V/W and minimum NEP of 100 $pW/Hz^{1/2}$ at 145 GHz. The chip size is $400{\mu}m{\times}450{\mu}m$ including the probing pads and a balun, while the core of the circuit occupies only $150{\mu}m{\times}100{\mu}m$.

Energy and Angular Response of CR-39 Neutron Track Detector (중성자 비적 검출기 CR-39의 에너지 및 입사각 응답특성)

  • Kim, Jang-Lyul;Ha, Chung-Woo;Yoon, Yea-Chang;W.G. Cross;A. Arneja
    • Nuclear Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.71-79
    • /
    • 1988
  • Published data of the efficiency of CR-39 detectors as a function of neutron energy from different laboratories show wide variations in the response obtained. These variations result from differences in etching conditions, in the materials and thickness of the radiator, in the sensitivities of CR-39 from different manufacturers and perhaps in criteria used for the size of spots that are counted. This paper describes some effects of these factors on the energy and angular response with calculational results. Calculated and measured results of the variations of response with neutron incident angie are more consistent than those of energy response. The data calculated show that the angular response is not a strong function of neutron energy except below about 0.3 MeV.