• Title/Summary/Keyword: 검출기교정

Search Result 113, Processing Time 0.024 seconds

TheReviser : A Gesture-based Editing System on a Digital Desk (TheReviser : 가상 데스크 상의 제스처 기반 문서 교정 시스템)

  • Jung, Ki-Chul;Kang, Hyun
    • The KIPS Transactions:PartB
    • /
    • v.11B no.4
    • /
    • pp.527-536
    • /
    • 2004
  • TheReviser is a digital document revision application on a projection display, which allows us to interact a digital document with the same gestures used for paper documents revision. To enable these interactions, TheReviser should detect foreground objects such as hands or pens on a projection display, and should spot and recognize gesture commands from continuous movements of a user. To detect foreground objects from a complex background in various lighting conditions, we perform geometry and color calibration between a captured image and a frame buffer image. TheReviser uses an HMM-based gesture recognition method Experimental results show that the proposed application recognizes user's gestures on average 93.22% in test gesture sequences.

Manufacture of a Gamma-ray Source using the Neutron Activation and Determination of a HPGe Detector Efficiency (중성자 방사화법을 이용한 감마선원 제조 및 HPGe 검출기 효율 결정)

  • Seo, Bum-Kyoung;Lee, Kil-Yong;Yoon, Yoon-Yeol;Lee, Kune-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.17-23
    • /
    • 2004
  • In order to save time and money needed in the purchase commonly used gamma-ray standard sources, a new radioactive standard source was manufactured by the neutron activation of some regent in the research reactor HANARO. The source was manufactured with an aqueous solution by mixing and dissolving the irradiated reagents. The manufactured source was compared with a commercial standard source. It was confirmed that it could be used as an efficiency calibration source. Also, in order to compare the variation of efficiency due to the volume difference for various containers used in radioactivity assay, the efficiency variation as a function of sample volume was investigated.

Calibration Examination of Dose Area Product Meters using X-ray (X선을 이용한 면적선량계의 교정 연구)

  • Jung, Jae Eun;Won, Do-Yeon;Jung, Hong-Moon;Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.37-42
    • /
    • 2017
  • We measured the absorbed dose and the area dose using an ionization chamber type of area dose product (DAP) meter and measured the calibration factor in the X-ray examination. In the indirect dose measurement method, the detector was installed in the radiation part of the X-ray equipment, and the measured value was calculated as the dose at the exposure part. The instrument used to calculate the calibration factor was an X-ray equipment (DK-550R / F, DongKang Medical Co., Ltd., Seoul, Korea). The calibration method for the calibration factor was to connect the DAP meter (PD-8100, Toreck Co. Ltd., Japan) to the calibration dosimeter tube voltage of 70 kV, tube current of 500 mA, 0.158 sec. The reference dosimeter used a semiconductor (DOSIMAX plus A, Scanditronix, $Wellh{\ddot{o}}fer$, Germany). After installing the DAP meter on the front of the multi-collimator of the ionization chamber, the calibration factor of the dosimeter was obtained using the reference dosimeter for accurate dose measurement. Experimental exposure values and values from the calibration dosimeter were calculated by multiplying each calibration factor. The calibration factor was calculated as 1.045. In order to calculate the calibration coefficient according to the tube voltage in the ionization type DAP dosimeter, the absorbed dose and the area dose were calculated and the calibration factor was calculated. The corrective area dose was calculated by calculating the calibration factor of the DAP meter.

SI-traceable Calibration of a Transmissometer for Meteorological Optical Range (MOR) Observation (기상관측용 투과형 시정계의 국제단위계에 소급하는 교정)

  • Park, Seongchong;Lee, Dong-Hoon;Kim, Yong-Gyoo
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.2
    • /
    • pp.73-82
    • /
    • 2015
  • This work demonstrates the indoor SI-traceable calibration of a transmissometer with a 75-m baseline for the measurement of visibility in MOR (Meteorological Optical Range). The calibration is performed using a set of neutral density (ND) filters (OD 0.1-2.5) and a set of high-transmission quartz glass plates (a bare quartz glass plate and antireflective-coated quartz glass plates), the collection consisting of 20 artifacts in total. The luminous transmittance values of the reference artifacts had been calibrated traceable to the KRISS spectral transmittance scale, which ranges from 0.2 % to 99.5 %. The transmissometer to be calibrated typically consists of a loosely collimated light source based on a white LED (CCT ~5000 K) and a luminous intensity detector with a CIE 1924 V(${\lambda}$) spectral response. As a result of calibration, we obtained the MOR error and its uncertainty for the transmissometer in 20 m - 40 km of MOR. Based on the results, we investigated the applicability of the calibration method and the conformity of the transmissometer to the ICAO's (International Civil Aviation Organization) accuracy requirement for meteorological visibility measurement. We expect that this work will establish the standard procedure for the SI-traceable calibration of a transmissometer.

MIRIS 지구관측 적외선카메라 인증모델 성능 시험 및 Field Test

  • Mun, Bong-Gon;Park, Yeong-Sik;Lee, Chang-Hui;Park, Seong-Jun;Cha, Sang-Mok;Lee, Dae-Hui;Jeong, Ung-Seop;Nam, Uk-Won;Park, Jang-Hyeon;Yuk, In-Su;Ga, Neung-Hyeon;Lee, Mi-Hyeon;Lee, Deok-Haeng;Yang, Sun-Cheol;Kim, Yeong-Ju;Lee, Gi-Hun;Jeong, Han;Lee, Seung-U;Han, Won-Yong
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.45.1-45.1
    • /
    • 2009
  • 과학기술위성 3호의 주탑재체인 MIRIS (Multi-purpose InfraRed Imaging System)는 우주관측카메라 (Space Observation Camera, SOC)와 지구관측카메라 (Earth Observation Camera, EOC)가 독립적인 시스템으로 구성되어 있다. 지구관측카메라는 유효 구경 100 mm, F/5의 광학계로 3-5 마이크론 파장영역을 관측하며, 국내에서 개발된 적외선 검출기의 우주 인증 시험과 유사시 한반도 적외선 감시를 주요 목적으로 하고 있다. 고도 700km에서 지상을 볼 때 약 42m/pixel의 공간분해능을 나타낼 것으로 기대하고 있다. 지구관측카메라의 인증 모델(Qualification Model)은 냉동기를 제외한 모든 부품이 국내기술로 제작되었으며, 미러 본딩 및 릴레이 렌즈 조립 기술, 적외선 영상 검교정 기술 등 다양한 경험과 도전을 제공했다. 이 발표에서는 지구관측카메라 인증모델을 이용하여 수행한 주요 시험 과정을 소개한다. 국내 회사 (주)i3 system에서 제작된 적외선 검출기는 $320\times256$ HgCdTe array (평균 양자효율 80% 이상) 이며 77K에서 정상적으로 운영된다. Micro Stirling Cooler에 의해 듀어는 전원을 켠 후 5분 이내에 검출기 운영온도인 77K까지 내려간다. 적외선 광학계의 정렬, 시스템 MTF 측정, 흑체 측정 및 검교정 작업을 수행한 후 야외에서 다양한 경우에 대해 Field Test를 진행했다. 이 발표에서는 Field Test 과정과 이를 통해 얻은 결과를 발표하고, FM (Flight Model) 제작에 있어 수정해야 할 사항들을 제안해 본다.

  • PDF

원자로 정지 관련 동적보상기의 응답시간 평가

  • 주운표;황희수;우숭웅;김건중
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.309-314
    • /
    • 1996
  • 가압 경수로형 원전 안전정지/ 안전 주입 변수와 관련된 계기는 관련 기술 기준에 따라 정기 보수시 교정이 이루어지면, 정지 신호를 모의 주입하여 물리량 검출기로 부터 원자로 정지집계 권선의 풀림시간까지의 총 응답 시간이 사고해석시 가정된 계통의 응답 지연시간이내에 들어 있는 지를 확인한다. 이 정지 신호에 응답하는 동적 보상기의 특성과 관련하여 설계과정에서 삽입된 근사화 오차에 대한 정략적인 평가가 이미 알려진 바 있고, 시간 응답 측정시 삽입되는 지연 요소로 인한 오차도 이에 포함시켜 분석한 바 있어 실제 교정시 정밀도 향상을 위하여 활용하고 있다. 이 논문을 통하여 원자로 정지계통의 응답시간 측정시 노 냉각수 평균 온도 변화율 동적 보상 미분-지연 카드에 모의입력으로 스텝신호를 주입할 경우, 이를 과도하게 큰 신호로 인식하여 매우 짧은 시간(1초 이내)에 응답되고, 스텝신호대신 1%P.U./초로 평균온도 변화율만을 주입할 경우, 보다 늦게 응답됨을 밝혔다. 따라서 모의 시험 방범에 있어서 입력 선택을 적합하게 하여야만 계통의 건전성을 응답시간으로 확인한 수 있는 데, 이에 적합한 모의 입력 방법을 제안하였다.

  • PDF