• Title/Summary/Keyword: 검안기

Search Result 10, Processing Time 0.019 seconds

의료용 광계측 및 센서기기 동향 및 전망

  • An, Seon-Yeong
    • Photonics industry news
    • /
    • s.36
    • /
    • pp.36-41
    • /
    • 2006
  • 의료용 광 계측은 의광학의 일부분으로 빛이 생체조직과 일으키는 상호작용을 이용하여 환자의 치료나 진단 또는 의학 기초분야의 발전에 효과적으로 사용하고 있다. 광 계측 및 센서기기를 응용하여 제품화된 의료용품들에는 혈당센서,혈압센서,내시경,검안기,영상진단기 등이 있다. 특히 혈당센서의 경우 급속하게 늘어가고 있는 당뇨병 환자의 수요에 비례한 시장이 현재 세계시장규모인 5조원에서 연간200%씩 증가될 것으로 예측되고 있다. 내시경의 세계시장은 매년 약 5% 내외의 성장을 거듭하고 있으며 검안기는 매년 약 7.2%의 성장률을 기록하고 있다.

  • PDF

A Study on Digital Healthcare Optometry System Using Optometry DB

  • Kim, Do-Yeon;Jung, Jin-Young;Kim, Yong-Man;Park, Koo-Rack
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.9
    • /
    • pp.155-166
    • /
    • 2021
  • Recently, digital health care technology is spreading and developing in various fields. Therefore, in this paper, we realized that the field to which digital healthcare technology is not applied is the field of optometry, and implemented a digital healthcare optometry system for precise lens manufacturing. A device called Phoroptor is used to manufacture the lens, and this device sets the lens by measuring the visual acuity of the person who requested the glasses. And when the person to be measured wears glasses, a device called a PD meter is used to align the pupil center and lens focus. However, there is a limit to the convenience of precise lens production and optometry due to the absence of a database and program that can accumulate and analyze the PD measurement error, inconvenience and error due to manual control of the Phoroptor, and optometric information. Therefore, in this paper, PD meter design for more accurate PD measurement, Phoroptor design and Phoroptor control application design for automatic Phoroptor control, and a database and analysis program that automatically set lenses using optometry information for each subject had been designed. Based on this, ultimately, a digital healthcare optometry system using an optometry database has been implemented.

Super Multi-View 3D Display Using Liquid-Crystal Shutter Glasses and Parallax Barrier (액정 셔터 안경방식 3D 디스플레이와 패럴랙스 베리어를 이용한 초다시점 3D 디스플레이)

  • Lee, Hyun-Min;Kwon, Ki-Chul;Park, Jae-Hyeung;Kim, Sung-Kyu;Min, Sung-Wook;Kim, Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.2
    • /
    • pp.130-138
    • /
    • 2014
  • In this paper, the SMV 3D display method using liquid crystal shutter glass(LCSG) and SPB has been proposed. The proposed SMV display can solve the resolution degradation problem of conventional multiview displays that using based time-multiplexing method. Also, observers fatigue due to the mismatch between accommodation and vergence problem of glass-type 3D displays and conventional multiview displays, can be improved using SMV 3D display method.

Criminal Investigators' Recognition of Judicial Autopsy and It's Implications - With the Case of P Police Station - (사법부검에 대한 수사경찰의 인식분석 및 함의 - P 경찰서의 사례를 중심으로 -)

  • Park, Dong-Kyun;Choi, Mu-Chan
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.12
    • /
    • pp.256-263
    • /
    • 2008
  • Based on the analysis of criminal investigators' recognition of judicial autopsy, this study presented policy alternatives as follows. First, a procedure is needed that optometrists and investigators jointly make previous explanations to bereaved families the status of investigation and the results of examination to their satisfaction and collect their opinions, for the purpose of obtaining an agreement to autopsy from them. Second, the dignity of the dead should be kept. To this end, particular consideration should be given to women bodies. Also, we need to minimize the number of autopsy witnesses and obtain agreement from bereaved families when there is an on-the-spot study. Third, we need to establish a guideline that investigators could request a warrant later in certain cases of dead bodies. Also, if a bereaved family positively asks for autopsy, it should be allowed through tentatively named ‘Request for Autopsy.’ Finally, To make a careful decision on whether an autopsy should be made or not, we can form a joint investigation team of public prosecutors and criminal investigators; however, an autopsy should be done only if it is deemed inevitable, considering the bereaved family's opinion.

Relationship Between the Degree of Exophoria and Stereoacuity (외사위의 정도와 입체시의 관계)

  • Shin, Hoy-Sun;Lee, Sun-Haeng;Yun, Mi-Ok;Kim, Mi-Yeon;Bea, Hong-Sup;Park, Sang-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.41-46
    • /
    • 2009
  • Purpose: Stereopsis is one of primary characteristics for assessment of binocular function. The purpose of this study was to determine the possible relationship between the degree of exophoria and stereoacuity at near. Methods: 110 exophores (male n=71, female n=39, mean $age{\pm}SD=11.30{\pm}1.47$ years) without amblyopia, strabismus, and ocular and systemic pathology were studied. Subjects were also excluded if they had visual acuity poorer than 0.8 in either eye or vertical phoria greater than 1 prism diopter. Clinical tests were performed for near phorias by von Graefe technique using a Digital Refractor (CDR-3100, Huvitz, Korea) with chart (Predio CDC-4000, Huvitz, Korea), and for stereoacuity using the Titmus fly. Results: A one-way analysis of variance revealed that mean values of the stereoacuity classified according to the degrees of the exophoria were not significantly different (p>0.05). Conclusions: Based on the result of this study, it was found that there was no relationship between the degree of exophoria and stereoacuity.

  • PDF

The Study on Hansen's Disease of Ametropia (나환자들의 비정시에 대한 고찰)

  • Lee, Hark Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.145-150
    • /
    • 1998
  • To 160 persons(90 men, 70 women) who went to the national hospital of Solok-island with Hansens's disease, I tested the objective refracts test with the product of Cannon Ltd. Co. which RK-3 Auto Ref-keratometer's auto ophthalmoscope. The results were like these. Visual acuity of above 0.7 that can live without glasses was contained 44 men's eyes(24.4%) and 19 women s eyes(13.6%). These result are indicated that men have had more good visual acuity than women. Visual acuity of below 0.6 that cannot do normal life was contained 80.3% of the total patients. And amblyopia of below 0.3 and eyes which cannot be corrected were shown 44.4%(80 men's eyes and 55.7% 78 woman's eyes). Myopia was contained 119 eyes(43), hyperopia was contained 139 eyes (50.4%) and emmetropia was 6.5%. Astigmatism was shown 136 men s eyes (86.6%) and 97 women's eyes(81.5%). These results are indicated what many people accompany with astigmatism. And these ratio had some high percentages men rather than women. Direct astigmatic was contained 37 eyes (11.6%), Indirect astigmatic 81 eyes(25.3%) and Oblique Astigmatic 115 eyes(35.9%). As a of distributed result oblique astigmatic occupied best high point as 49.4% in 233 astigmatism and distributed the opposite direction as compared with normal irregular emmetropia not patient.

  • PDF

A Study of correlation between spherical refractive error and astigmatism (굴절이상도와 난시와의 관계 연구)

  • Lee, Jeung-Young;Kim, Jae-Do;Kim, Dae-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.439-446
    • /
    • 2004
  • Many studies have reported that retinal defocus cause and increase refractive error specially myopia. Uncorrected astigmatism may be one factor of retinal defocus factors. To understand the relationship between myopia and astigmatism 62 college students were participated in this study. Spherical refractive error and astigmatism were measured using N-vision 5001 autorefractor (Shinnippon). Co-relations between spherical refractive error and astigmatism were high both in the with-the-rule astigmatism group(r=0.53; ANOVA F=32.40, N=87, P<0.05) and oblique astigmatism group (r=0.53ANOVA F=5.14, N=15, P<0.001). However it was very low (r=0.09; ANOVA F=0.18, N=22, P<0.001)in the against-the-rule stigmatism group. In the total group co-relation was also high (r=0.56: ANOVA F=77.80, N=173, P<0.001). Uncorrected astigmatism may cause and increase spherical refractive error.

  • PDF

The Aging Eye and World Blindness (노안과 세계적인 맹)

  • Cullen, Anthony P.;Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.105-115
    • /
    • 2004
  • In developed and industrialized countries life expectancy has increased significantly over the past century. As a consequence, the proportion of elderly individuals in these countries has also enlarged with the resulting increased burden on health care providers. In many developing countries the problem of age related and other eye disorders has far outstripped the ability to manage them. Accordingly, the World Health Organization (WHO) has introduced an initiative: Vision 2020 - The Right to Sight, with the objective of eliminating preventable blindness by the year 2020. This paper reviews the broad range of conditions involving external and internal structures of the eye and also the effects of aging on visual functions. It is hoped that this will provide a stimulus for increased study of these disorders, improved clinical diagnosis, and an enhanced interest and role in contributing to the objectives of the WHO and the World Council of Optometry with respect to early diagnosis, prevention and management of the diseases and disorders of the eye that are more prevalent in old age.

  • PDF

A Study of Optical System Design for a Retinal Camera (망막 카메라용 광학계 설계)

  • Hong, Kyung-Hee
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.113-119
    • /
    • 2006
  • We need a good image of the retina of the human eye in order to inspect or cure it. In this work, an optical system design for a retinal camera is studied and the finite schematic eye model made by Sang Gee Kim and Sung Chan Park is used. The optical system is composed of four lens groups. The rays of the entire object field are collected on the center by the 1st group and the objective is imaged by all the other groups. The image is detected by the CCD array and displayed by a monitor The 1st lens group is employed singlet and other groups are employed triplets. Ray aberrations, spot diagrams, diffraction line spread functions and MTFs are calculated for optical performance assessment. This design may be very useful for the development of a retinal camera with high performance.

STUDIES ON AVIAN VISCERAL LYMPHOMATOSIS I. THE INCREASED INCIDENSE AMONG CHICKEN FLOCKS AND PATHOLOGIC PICTURES (장기형임파종증(臟器型淋巴腫症)에 관(關)한 연구(硏究) 1. 계군(鷄群)에서의 임파종증(淋巴腫症)의 발생(發生) 및 병리학적소견(病理學的所見))

  • Kim, Uh Ho;Lim, Chang Hyeong
    • Korean Journal of Veterinary Research
    • /
    • v.4 no.1
    • /
    • pp.35-42
    • /
    • 1964
  • 1). An nanlysis was made of 3,500 postmortem diagnoses for the three years 1961 through 1963 to determine whether there was any actual incidence of avian visceral lymphomntosis in the field. Chickens autopsied, which showed gross alterations were 7.6 percent or 266 cases. The diminished incidence of the disease in second and third years seemed due to decreased total numbers of chicken flocks year by year for the reason of difficult feed supply. 2). Because chickens autopsied in this study were not clearly known of their breeds and lines, no distinct data on the incidence in various breeds were made. Some exact breeds were in too small numbers to have any statistical significance. Inconceivably, no other types of avian leukosis than visceral lymphomatosis had been observed in any appreciable number in this analysis. 3). Pathologic analysis for affected organs was made grossly and microscopically. In the gross pictures, liver, spleen, kidney, ovary, and in some case, intestine principally showed lesions, but its manifestation was variable in different organs. In such organs, livers were affected more frequently, and spleens followed next. The organs were classified and arranged according to the gross alterations, and among their distribution one-half of livers were in diffuse variety; one-fourths in nodular; about one-sevenths in mixed; and granular variety followed next. In the spleen samples, two-thirds were in diffuse variety; one-fourths in nodular; and follicular only in three cases. Ovaries almost showed follicular lesions, the diffused were less than one-fifths of total specimens. Kidneys were occurred almost in diffuse variety. And intestine showed only nodular tomors. Microscopically, 42 cases of visceral lymphomatosis composed of 24 livers, 10 spleens, 3 kidneys, 3 intestines and 2 ovaries were examined. The tumor cells were lymphoid cells showing various component in size, shape and stainability. Mitotic figures were usually present. The proportion of the component cells were various in all cases and there were variations in the distribution of the tumor cells. The types of distribution were classified according to the standard proposed by Horiuchi as nodular, infiltrative and diffuse proliferation. In cases of visceral lymphomatosis of the livers and the spleens the types of infiltrative, nodular and diffuse proliferation could be classified. In the cases of the kidneys the types of diffuse and nodular proliferation were observed. In the cases of the intestines and the ovaries the types of infiltrative and diffuse proliferation were observed respectively.

  • PDF