• Title/Summary/Keyword: 검사 장비

Search Result 987, Processing Time 0.034 seconds

Design and Implementation of Hand-Held Inspection Device for High Performance Mobile TFT LCD/OLED Module (고성능 모바일 TFT LCD/OLED 모듈을 위한 헨드헬드 검사장비 설계 및 구현)

  • Moon, Seung-Jin;Kim, Hong-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6B
    • /
    • pp.630-640
    • /
    • 2009
  • The thesis suggests hand-held equipment to overhaul for mobile TFT LCD/OLED module of high-performance. The established module equipment to overhaul could distinguish outputting video data to module for distinguishing flicker, but it is impossible with low system. In this thesis, supporting system could check the various supplement functions from bringing equipment to overhaul without changing design of FPGA or H/W the module various size for equipment to overhaul for module of high-performance coincidently. The system includes hand-held equipment to overhaul, test software embedded and software a base personal computer and have designed to output, save, and certify all contents of module test of hand-held equipment to overhaul to interface universal serial bus. Setting up 9 items that represent for efficient verification of the proposed system have been possible confirmation with TFT LCD/OLED module of high-performance, establishment scan time, creation gamma, changing register, supporting interface, and multi inch modules.

Noise Exposure of Radiographer Caused by Magnetic Resonance Imaging(MRI) (자기공명영상(MRI) 검사 시 방사선사의 소음노출)

  • Gil, Jong-Won
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.11
    • /
    • pp.699-706
    • /
    • 2016
  • This study aimed to propose the necessity and system establishment of noise reduction facility via evaluating noise level exposed by the radiographer due to MRI scan. Noise measurements were carried out using at S general hospital in Daejeon using 1.5 Tesla MRI (7 exams) and 3.0 Tesla MRI (16 exams), while using SC-804 noise meter. The measurement distance was from the soundproof door of the MRI room to the radiographer which measured 100cm, and the measurement height, the height to the radiographer's ears when working, 100cm. The noise measured for each exam was an average of three measures per exam which observed the noise occurring in each sequence recorded every 20 seconds. As the results, the maximum of noise exposed by the radiographer is 73.3 dB(A), which is MRCP by the 3.0 Tesla device, and also the maximum of average noise is 66.9(3.1) dB(A), which is Myelogram by the 3.0 Tesla device. Average noise by each device is 61.9(4.1) dB(A) by the 3.0 Tesla device and 52.0(3.1) dB(A) by the 1.5 Tesla device, which comes to the result that the 3.0 Tesla MRI device is about 10 dB(A) degree higher(p <0.001). The noise level exposed by the radiographer does not affect auditory acuity, but the level is able to incur a non auditory effect. The reflect sound can be removed by installing curtains in the rear wall of MRI control room in order to reduce the noises, but, first of all, An institutional system is needed in order to prevent noise.

Design of DICOM Standard Interface Module for Medical Image Standardization (의료영상 표준화를 위한 DICOM 표준 인터페이스 모듈 설계)

  • Kim, Sung-Hyun;Jeon, Jae-Hwan;Kim, Gwan-Hyung;Kang, Sung-In;Oh, Am-Suk
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.221-224
    • /
    • 2010
  • PACS(Picture Archiving Communication System)를 바탕으로 하는 DICOM(Digital Imaging and Communications in Medicine)은 주요 의료영상장비들 사이에 데이터와 영상을 효율적으로 교환하고 전송할 수 있도록 마련한 표준안으로 현재 대부분의 최신형 의료영상장비(CT, MR, DSA, CR(Computed Radiology), 초음파검사, 핵의학검사, 내시경검사, 조직병리검사, 등)들은 의료 영상 분야의 국제 표준인 DICOM 표준방식에 의해 영상을 제공하고 있다. 최근 이러한 의료영상장비들은 독립적으로 사용하기보다는 의료수술 모니터링 장비 등의 비 의학영상장비와 서로 연계하여 사용하는 경우가 많아졌다. 그러나 이러한 의료수술 모니터링 장비들은 DICOM 표준 데이터를 고려하지 못하므로 PACS를 통한 데이터 연계에 어려움이 있다. 따라서 본 논문에서는 표준 DICOM 포맷과 의료수술 모니터링 장비의 데이터 구조를 분석하여 non-DICOM 의료수술 모니터링 장비의 PACS 연동을 위한 방안을 제안하였다.

  • PDF

The Study of Patient Dose Comparison on Liver Computed Tomography : For 4 Equipment Vendors (간 전산화단층촬영 시 환자 선량 비교 연구 : 4개 장비회사를 대상으로)

  • Joo, Young-Cheol;Lim, Chung-Hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2013.05a
    • /
    • pp.215-216
    • /
    • 2013
  • 본 연구는 간 CT검사를 받은 환자의 선량 및 일반적 정보를 이용하여 후향적으로 진행된 연구로서, 우리나라에서 사용 빈도가 높은 4개사의 CT장비에서 각 장비별로 간 CT검사 시 환자가 받는 평균유효선량의 차이를 알아보고, 성별, 연령, 신장, 체중과 같은 환자의 특성에 따라 장비사별 환자선량을 비교 분석을 통해 임상에서 각자의 장비를 이용하여 방사선사가 간 CT검사를 진행하거나 새로운 검사조건 설정 시 환자선량 감소를 위해 고려해야 할 사항을 제시하는데 목적이 있다.

  • PDF

초정밀 스테이지의 반복정밀도 분석

  • 박종하;황주호;박천홍;홍준희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.320-320
    • /
    • 2004
  • 반도체용 노광장비나 검사장비, 초정밀 광학렌즈, 비구면 렌즈 가공 등의 핵심이 되는 것은 초정밀결정기술이다. 서브미크론의 정밀도를 갖는 장비는 한치의 오차도 허용치 야고 계획된 경로대로 정확하게 목표지점에 도달해야 초정밀 가공을 기대 할 수 있다 초정밀 공기정압 스테이지는 저마찰 특성과 높은 운동정밀도, 청정환경유지가 가능하여 반도체 노광장비에서 PDP 나 LCD검사장비, 초정밀가공 가공기 등 다양한 정밀장비에서 활용된다.(중략)

  • PDF

Evaluation of X-ray System for Nondestructive Testing on Radioactive Waste Drums (방사성폐기물 드럼 비파괴 검사를 위한 X-ray 장비 평가)

  • Park, Jong-Kil;Maeng, Seong-Jun;Lee, Yeon-Ee;Hwang, Tae-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.189-203
    • /
    • 2008
  • The physical and chemical properties of radioactive waste drums, which have been temporarily stored on site, should be characterized before their shipment to a disposal facility in order to prove that the properties meet the acceptance guideline. The investigation of NDT(Nondestructive Test) method was figured out that the contents in drum, the quantitative analysis of free standing water and void fraction can be examined with X-ray NDT techniques. This paper describes the characteristics of X-ray NDT such as its principles, the considerations for selection of X-ray system, etc. And then, the waste drum characteristics such as drum type and dimension, contents in drum, etc. were examined, which are necessary to estimate the optimal X-ray energy for NDT of a drum. The estimation results were that: $(R)\acute{A}$ the proper X-ray energy is under 3 MeV to test the drums of 320 ${\beta}\S$ and less; $(R)\ddot{E}$ both X-ray systems of 450 keV and/or 3 MeV might be needed considering the economical efficiency and the realization. The number of drums that can be tested with 450 keV and 3 MeV X-ray system was figured out as 42,327 and 18,105 drums (based on storage of 2006. 12), respectively. Four testing scenarios were derived considering equipment procurement method, outsourcing or not, etc. The economical and feasibility assessment for the scenarios was resulted in that an optimal scenario is dependent on the acceptance guide line, the waste generator's policy on the waste treatment and the delivery to a disposal facility, etc. For example, it might be desirable that a waste generator purchases two 450 keV mobile system to examine the drums containing low density waste, and that outsourcing examination for the high density drums, if all NDT items such as quantitative analysis for 'free standing water' and 'void fraction', and confirmation of contents in drum have to be characterized. However, one 450 keV mobile system seems to be required to test only the contents in 13,000 drums per year.

  • PDF

Comparison of the Values of Bone Mineral Density Between DEXAs (DEXA 측정기 간 골밀도 값 비교)

  • Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.271-276
    • /
    • 2011
  • Statistical analysis was performed on the patients who took bone densitometry using Lunar and Hologic equipments for 5 months from January $1^{st}$ 2010 to May $30^{st}$, 2010. Patients consisted of 50 in their 40s, 100 in 50s and 50 in 60s. In addition, the results from bone densitometry were carried out on the same subject with two equipments on the same day. In case of 200 subjects, who received the bone densitometry with two equipments, the average age was 54.5 and 54.4 years old, respectively. There was no difference. The T- score of Lunar equipment was $-1.377{\pm}1.221$ and that of Hologic equipment was $-1.806{\pm}1.123$. The T-score of Lunar equipment was measured higher than that of Hologic equipment. T-test was conducted to determine the equality of the mean of two groups with 200 patients. Since the pvalue was 0.000, the value of bone mineral density was significant in two equipments. Furthermore, the patients, who were diagnosed by Lunar, showed more 'normal' and who were diagnosed by Hologic, showed more osteoporosis, which cartegorized by WHO, such as normal, osteopenia, and osteoporosis. Thus, compared results of bone densitometry on lumbar spine L1 - L4 of four normal people with the same equipment showed that T- score of Lunar equipment was $-0.4{\pm}1.2$, and T- score of Hologic equipment was $-1.1{\pm}1.5$. It showed the higher T- score was measured in Lunar equipment as well. Therefore, the correction factor should be considered to use, since T- scores are different between two equipments.

Evaluation for the Usefulness of Automated Blood Typing Analyzer (혈액은행 자동화 장비 도입의 유용성 평가)

  • Kim, Ha-na;Kim, Hee-Bum;Park, Hyun-Sang;Lee, Hyun-Im;Hong, Myung-Kook;Shin, Gyoung-Sook;Suh, In-Bum
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.6
    • /
    • pp.565-574
    • /
    • 2019
  • In this study, we evaluated the usefulness of an automatic blood typing analyzer using QWALYS-2 up (Diagast, Loos Cedex, France). During a month( 01OCT2013 - 31OCT2013) we performed 1,636 tests for ABO & RhD blood typing, 1,374 tests for antibody screen & identification tests and compared the results by automatic blood type analyzer with previous manual methods and column agglutination tests. And we analyzed the economic performance by comparison the test unit price between automatic blood type analyzer and manual methods. In ABO & RhD blood typing tests, there were complete concordances between manual and automated blood typing analyzer for 200 clinical samples. In Antibody screen tests, the concordance rate between manual and automated blood typing analyzer was 98.5% and more strong reaction in automated blood typing analyzer than manual methods. Therefore, the introduction of an automated blood typing analyzer, reagents costs were increased but labor costs were decreased. Considering the importance of transfusion safety and economic advantages, the introduction of an automated blood typing analyzer was very useful.

A Study on the Nondestructive Test Optimum Design for a Ground Tracked Combat Vehicle (지상궤도전투장비의 비파괴검사 최적설계방안에 대한 연구)

  • Kim, Byeong Ho;Seo, Jae Hyun;Gil, Hyeon Jun;Kim, Seon Hyeong;Seo, Sang Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.358-366
    • /
    • 2015
  • In this study, a nondestructive test (NDT) is performed to inspect the optimal design of a ground tracked combat vehicle for self-propelled artillery, tank, and armored vehicles. The minimum qualification required for personnel performing the NDT of a ground tracked combat vehicle was initially established in US military standards, and then applied to the Korean defense specifications to develop a ground tracked combat vehicle. However, the qualification standards of an NDT inspector have been integrated into NAS410 through the military and commercial specifications unification project that were applied in the existing aerospace/defense industry public standard. The design method for this study was verified by applying the optimal design to the liquid penetrant testing Al forging used in self-propelled artillery. This confirmed the reliability and soundness of the product.

항로표지장비 ${\cdot}$ 용품의 성능 검사

  • Kim, Jong-Uk
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.495-499
    • /
    • 2006
  • 선박의 안전한 항해와 운항능률을 향상시키기 위하여 사웅중인 광파표지에 사용하는 등명기의 경우 그 자체에 대한 중요성은 많이 인식되었으나 그 외의 항로표지장비${\cdot}$용품은 사용범위 및 빈도에 비해 중요성이 많이 인지되고 있지 않아 e-Navigation 시대에 맞추어 항로표지장비·용품의 품질 향상 및 기능 유지를 위한 성능 검사 방법 및 전원공급시스템의 실태 파악 분석결과에 대하여 기술하였다.

  • PDF