• Title/Summary/Keyword: 검사 유닛

Search Result 20, Processing Time 0.032 seconds

Design of LED TV Multi Test Unit (LED TV 통합검사유닛의 설계)

  • Kouh, Hoon-Joon
    • Journal of Digital Convergence
    • /
    • v.10 no.4
    • /
    • pp.37-43
    • /
    • 2012
  • LED TV integration test unit are the equipment for testing LED BLU as LED BLU's operation, error check, AGING work. The previous test unit were inconvenient because it must change test unit in production line according to LCD's kind and size. This paper develops by integration style test unit that can accommodate various LED TV BLU model of 32 ~ 52 inch that is not one LED TV BLU model. We make that output current is various to dimension of 80 ~ 215 mA. We make functions that are LED BLU state check, Diming and heat occurrence mitigation. Also we develop firmware program and that the program can be upgraded and that can support new panel.

Development of Vision system for Back Light Unit of Defect (백라이트 유닛의 결함 검사를 위한 비전 시스템 개발)

  • Cho, Sang-Hee;Han, Chang-Ho;Oh, Choon-Suk;Ryu, Young-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.127-129
    • /
    • 2005
  • 본 연구에서는 백라이트 유닛의 검사를 위한 머신비전 시스템을 구축한다. 시스템은 크게 하드웨어와 소프트웨어로 나눌 수 있고 하드웨어는 조명부, 영상획득부, 로봇 암 제어부로 분류된다. 조명부는 36W FPL램프로 구성되었고 조명부의 상판에 아크릴판을 거치대로 이용하여 백라이트 유닛을 거치한다. 로봇 암 제어부는 2축 로봇 암을 제어하여 로봇 암의 센서부착 지지대에 부착된 CCD 센서를 이동시킨다. 이와 동시에 영상획득부에서는 이미지를 획득하여 PC로 전송한다. 소프트웨어의 화상처리 검사 알고리즘은 일정 패턴이 있는 도광판에 대한 검사 알고리즘과 일정패턴이 없근 백라이트 유닛에 대한 검사 알고리즘으로 분리된다. 일정 패턴이 인쇄되어 있는 패널에 대한 검사 알고리즘은 모폴로지 연산을 이용하는 템플릿 체크방법과 블록 매칭 방법이 사용되었고 일정패턴이 없는 유닛에 대한 검사는 개선된 Otsu 방법을 이용하여 얼룩이나 흐릿한 결함에 대한 결함을 검출하였다. 실험결과 불균일한 결함과 밝기가 일정하지 않은 결함일지라고 90% 이상의 검출율로 뛰어난 성능을 입증하였다.

  • PDF

Comparison of Egg Testing Devices for Internal Egg Quality Measurements (계란 할란검사장비의 성능 비교)

  • Kim, Dong Jun;Jeon, Seung Yob;Kim, Hee Won;Won, Jea Sun;Lee, Jae Cheong;Lee, Kyung-Woo
    • Korean Journal of Poultry Science
    • /
    • v.43 no.4
    • /
    • pp.229-233
    • /
    • 2016
  • This study was conducted to compare three commercially available egg testing devices for measuring egg quality. The devices used were a Laser-type (automatic), a Ultrasonic-type (automatic), and a Probe-type (manual). Fresh eggs weighing 60~68 grams were obtained from a commercial hen farm. Three trials were conducted. In Trial 1, a total of 50 eggs were successively analyzed by the three egg testing devices. In Trial 2, fresh eggs were successively analyzed by a combination of two egg testing devices. In Trial 3, a total of 600 eggs (weighing 60~68 grams) laid by same flock were selected, further divided into three sub-groups with a total of 200 eggs, and analyzed by an egg testing device. In Trials 1 and 2, no apparent difference was observed in egg weight between egg testing devices. However, albumin height was scored highest in the Ultrasonic-type egg tester followed by the Probe-type and Laser-type (Trials 1 and 2). Consequently, the Haugh unit was similarly altered. Yolk color was highest in the Laser-type egg tester followed by the Ultrasonic-type and Probe-type (Trials 1 and 2). When fresh eggs laid by a single flock were independently analyzed by three devices, egg weight did not differ, but albumin height and Haugh unit were higher (p<0.05) in the Ultrasonic-type egg tester than in the Probe-type or Laser-type testers. However, Laser-type testers produced higher (p<0.05) yolk color values than the Ultrasonic-type or Probe-type egg testers. In conclusion, the commercially available egg testing devices exhibited performance differences in measuring egg qualities, which warrants further consideration as to whether the magnitude of bias and precision between the devices could be acceptable in the egg grading system, especially when assessing eggs stored for certain durations.

A Study on the Development of Diagnosing System of Defects on Surface of Inner Overlay Welding of Long Pipes using Liquid Penetrant Test (PT를 이용한 파이프내면 육성용접부 표면결함 진단시스템 개발에 관한 연구)

  • Lho, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.121-127
    • /
    • 2018
  • A system for diagnosing surface defects of long and large pipe inner overlay welds, 1m in diameter and 6m in length, was developed using a Liquid Penetrant Test (PT). First, CATIA was used to model all major units and PT machines in 3-dimensions. They were used for structural strength analysis and strain analysis, and to check the motion interference phenomenon of each unit to produce two-dimensional production drawings. Structural strength analysis and deformation analysis using the ANSYS results in a maximum equivalent stress of 44.901 MPa, which is less than the yield tensile strength of SS400 (200 MPa), a material of the PT Machine. An examination of the performance of the developed equipment revealed a maximum travel speed of 7.2 m/min., maximum rotational speed of 9 rpm, repeatable position accuracy of 1.2 mm, and inspection speed of $1.65m^2/min$. The results of the automatic PT-inspection system developed to check for surface defects, such as cracks, porosity, and undercut, were in accordance with the method of ASME SEC. V&VIII. In addition, the results of corrosion testing of the overlay weld layer in accordance with the ferric chloride fitting test by the method of ASME G48-11 indicated that the weight loss was $0.3g/m^2$, and met the specifications. Furthermore, the chemical composition of the overlay welds was analyzed according to the method described in ASTM A375-14, and all components met the specifications.

An implementation of 2D/3D Complex Optical System and its Algorithm for High Speed, Precision Solder Paste Vision Inspection (솔더 페이스트의 고속, 고정밀 검사를 위한 이차원/삼차원 복합 광학계 및 알고리즘 구현)

  • 조상현;최흥문
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.3
    • /
    • pp.139-146
    • /
    • 2004
  • A 2D/3D complex optical system and its vision inspection algerian is proposed and implemented as a single probe system for high speed, precise vision inspection of the solder pastes. One pass un length labeling algorithm is proposed instead of the conventional two pass labeling algorithm for fast extraction of the 2D shape of the solder paste image from the recent line-scan camera as well as the conventional area-scan camera, and the optical probe path generation is also proposed for the efficient 2D/3D inspection. The Moire interferometry-based phase shift algerian and its optical system implementation is introduced, instead of the conventional laser slit-beam method, for the high precision 3D vision inspection. All of the time-critical algorithms are MMX SIMD parallel-coded for further speedup. The proposed system is implemented for simultaneous 2D/3D inspection of 10mm${\times}$10mm FOV with resolutions of 10 ${\mu}{\textrm}{m}$ for both x, y axis and 1 ${\mu}{\textrm}{m}$ for z axis. Experiments conducted on several nBs show that the 2D/3D inspection of an FOV, excluding an image capturing, results in high speed of about 0.011sec/0.01sec, respectively, after image capturing, with $\pm$1${\mu}{\textrm}{m}$ height accuracy.

Development of Bio-Check Unit and Health Index for Measuring Health Degree through Noninvasive Examination (비침습적 검사를 통한 건강 정도 측정을 위한 바이오체크 유닛과 건강지수의 개발)

  • Lee, Chong-Sun;Yi, Sung-Il;So, Byung-Rok;Park, Byung-Kang;Chung, In-Wook;Lee, Seung-Ju;Park, Seon-Kyun;Han, Cheng-En
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.7
    • /
    • pp.859-865
    • /
    • 2011
  • A bio-check unit and health index were developed to provide information on personal health state with easily available noninvasive measurements and surveys. Four health indices were defined such as cardiovascular index, stress index, obesity index, and management index. Methods were developed to calculate health index scores from measured physiological signals and answer of survey questions. In order to evaluate effectiveness of the health indices, a clinical trial was conducted for 362 persons who visited general hospital for annual health inspection. The cardiovascular index showed a good correlation coefficient of 0.685 with the cardiovascular health graded by a medical doctor. The stress index showed a good correlation coefficient of 0.638 with the results of stress questionnaires being used in the public health center. Once the health index function is added in the bio-check unit, the unit may provide useful contents for personal health management.

An Efficient k-D tree Traversal Algorithm for Ray Tracing on a GPU (GPU상에서 동작하는 Ray Tracing을 위한 효과적인 k-D tree 탐색 알고리즘)

  • Kang, Yoon-Sig;Park, Woo-Chan;Seo, Choong-Won;Yang, Sung-Bong
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.3
    • /
    • pp.133-140
    • /
    • 2008
  • This paper proposes an effective k-D tree traversal algorithm for ray tracing on a GPU. The previous k-D tree traverse algorithm based on GPU uses bottom-up searching from a leaf to the root after failing to find the ray intersected primitive in the leaf node. During the bottom-up search the algorithm decides the current node is visited or not from the parent node. In such a way, we need to visit the parent node which was already visited and the duplicated bounding box intersection tests. The new k-D tree traverse algorithm reduces the brother and parent duplicated visit by using an efficient method which decides whether the brother node is already visited or not during the bottom-up search. Also the algorithm take place bounding box intersection tests only for the nodes which is not yet done. As a result our experiment shows the new algorithm is about 30% faster than the previous.

A Study Regarding Bacterial Contamination of Surfaces in Dental Offices (치과진료실 내 표면 세균 오염에 관한 연구)

  • Yun, Kyoung-Ok;Kim, Hye-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.4
    • /
    • pp.279-285
    • /
    • 2015
  • This study studied samples taken off surfaces at three sites (Unit chairs, light handles, cuspidors) of 19 dental hospitals and 28 clinics located in Gyeonggi-do and Incheon, South Korea. The bacterial contamination levels of surfaces were $44.82{\times}10^3CFU/mL$ in cuspidors, higher than in unit chairs ($5.47{\times}10^3CFU/mL$) and light handles ($16.28{\times}10^3CFU/mL$). The values were statistically higher at dental hospitals than at dental clinics, the greater number of patients being associated with the higher bacterial cell count in the cuspidors. The results of identifying the strains isolated purely from surfaces at dental clinic showed Gram positive 47.3% and Gram negative 52.7%. Among Gram positive, the most numberous bacteria were Micrococcus luteus (10.9%), Bacillus pumilus (3.6%), and Staphylococcus aureus (3.6%). Among Gram negative, the most numberous bacteria were Acinetobacter ursingii (5.5%), Brevundimonas diminuta (4.5%), Chryseobacterium (Flavo.) indologenes (CDC IIb) (4.5%), and Methylobacterium sp. (4.5%). This study measures the level of bacterial contamination and identifies the strains isolated in dental clinics. It recognizes the importance of infection control, and the results of the study may be considered as the basis for establishing specific plans for prevention of infection.

Correlation between Internal and External Egg Quality Indicators in the Early Phase of Hy-Line Brown Laying Hens

  • Jang, Eunhye
    • Korean Journal of Poultry Science
    • /
    • v.49 no.2
    • /
    • pp.53-60
    • /
    • 2022
  • This study investigated correlations between egg quality indicators to identify external egg quality traits to predict internal egg quality using non-destructive and convenient measurements. Thirteen indicators, including Haugh unit, albumen height, eggshell breaking strength, eggshell thickness, eggshell color (CIE L*, CIE a*, CIE b*), and reflectivity value, egg weight, egg length, egg width, shape index, and yolk color, were investigated. A total of 180 brown eggs were obtained from one 27-week-old flock of Hy-line brown-laying hens raised in a cage system. Correlations were evaluated using Pearson's correlation coefficient (r). The results showed strong correlations between Haugh unit and albumen height, eggshell color CIE L* and reflectivity, egg weight and width, egg weight and length, eggshell color CIE L* and CIE a*, eggshell color CIE a* and reflectivity, and shape index and egg length (P<0.001). Moderate correlations were observed between eggshell breaking strength and eggshell thickness, eggshell color CIE a* and CIE b*, and shape index and egg width (P<0.001). Eggshell color CIE L* was correlated with eggshell breaking strength (P<0.01), and eggshell color CIE a* was correlated with Haugh unit, albumen height (P<0.01), and eggshell breaking strength (P<0.001). The present study showed significant correlations between eggshell color and other quality indicators. Thus, this study suggests that eggshell colors based on reflectiveness and the CIE L*a*b* value can be used to estimate the Haugh unit, albumen height, eggshell breaking strength, and thickness.

Multiple Camera Based Imaging System with Wide-view and High Resolution and Real-time Image Registration Algorithm (다중 카메라 기반 대영역 고해상도 영상획득 시스템과 실시간 영상 정합 알고리즘)

  • Lee, Seung-Hyun;Kim, Min-Young
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.4
    • /
    • pp.10-16
    • /
    • 2012
  • For high speed visual inspection in semiconductor industries, it is essential to acquire two-dimensional images on regions of interests with a large field of view (FOV) and a high resolution simultaneously. In this paper, an imaging system is newly proposed to achieve high quality image in terms of precision and FOV, which is composed of single lens, a beam splitter, two camera sensors, and stereo image grabbing board. For simultaneously acquired object images from two camera sensors, Zhang's camera calibration method is applied to calibrate each camera first of all. Secondly, to find a mathematical mapping function between two images acquired from different view cameras, the matching matrix from multiview camera geometry is calculated based on their image homography. Through the image homography, two images are finally registered to secure a large inspection FOV. Here the inspection system of using multiple images from multiple cameras need very fast processing unit for real-time image matching. For this purpose, parallel processing hardware and software are utilized, such as Compute Unified Device Architecture (CUDA). As a result, we can obtain a matched image from two separated images in real-time. Finally, the acquired homography is evaluated in term of accuracy through a series of experiments, and the obtained results shows the effectiveness of the proposed system and method.