• Title/Summary/Keyword: 검사 시간

Search Result 3,823, Processing Time 0.039 seconds

The Change of Total Scan Time in Accordance with the Time of the Decision of Scan Time (스캔 시간의 결정시기에 따른 총 스캔 시간 변화에 관한 연구)

  • Lee, Jong-Hun;Ryu, Jae-Kwang;Chung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.81-85
    • /
    • 2009
  • Purpose: The examination of nuclear medicine observes the change in accordance with the time elapsed in the same region purposed and there are many examinations to acquire the image during the same term. At this time, the same parameter should be applied. The hepatobiliary scan, lung scan etc, are the acquired examination in the divided time with a regular term. Pre-set time that is applied in continued next image is set in order to acquire the fixed counts. The same scan time should be applied for each image. This study will look for the rational plan and analyze the change of scan time in accordance with the time of the decision of scan time at examination that pre-set time is applied. Methods: The hapatobiliary scan that use the radio pharmaceutical $^{99m}Tc$-mebrofenin is choosed as compensation from Jan. 2009 to Mar. 2009 in the department of nuclear medicine in ASAN MEDICAL CENTER. Scan is started after 5 minutes from when 222 MBq (6 mCi) is injected to patient. We let patient stand up between both detectors, and possibly close to the front of detector. When scan time reach 10%, 25%, 50%, 75% of total scan time, we measured the expected total scan time. After finishing all of scan, we compared the total scan time and the expected total scan time, while image is acquiring. and we observed the change of scan time in accordance with radio activity by using phantom. Results: After starting scan, a difference of when scan time reach 10%, 25%, 50%, 75% of total scan time is that the biggest difference is 5 seconds on 10%. There statistically is difference between 25% (t:2.88, p<0.01) and 50% (t:2.05, p<0.01). Conclusions: When the same the scan time is applied in the examination that acquire the many frame, concluding the same scan time has a important effect on a quantitative analysis. Although method that decide the scan time after finish all of the examinations, there is a few problem to apply practical affairs. This may cause an inaccurate result on the examination that need a quantitative analysis. We think that operator should try to improve it. At least, after reach 50% of total scan time, deciding the total scan time mean that you can minimize error of a quantitative analysis caused by unmatched scan time from a gap of image.

  • PDF

Study of SUVm Cut-off Value for the Distinction of Pancreatic Cancer In PET/CT Exam (PET/CT 검사에서 췌장암 판별을 위한 SUVm 경계값 연구)

  • Chang, Boseok;Kim, Jae Ho;Liu, Guoxu;Jang, Eun Sung
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.567-575
    • /
    • 2017
  • In this study, when diagnosis pancreatic cancer by dual time point PET/CT, we propose SUVm 2.52 as the threshold value for performing the dual time point PET/CT exam. The hypothesis of normal distribution was adopted through data conversion of 60 pancreatic diseases. The proposed SUVm2.52 boundary value showed a significance level that could be applied to both 120 and 180 minutes of delay time scan for pancreatic cancer determination (p<0.05). C-value variation shows that delay time 2 hour test is more useful than delay time 3 hour test. When the SUVm 2.52 is set to the boundary value and the double-time point PET/CT exam is performed, the probability of distinguishing cancer from inflammation in the delayed image is 95%. When the delayed test is performed with the proposed boundary value SUVm 2.52, Compared with general PET / CT scans, it is thought that it may be helpful to distinguish pancreatic cancer.

Analysis and Optimization of the Combined Primality Test Using gcd Operation (gcd 연산을 이용한 조합 소수 검사 알고리즘의 분석 및 최적화)

  • Seo, Dong-Woo;Jo, Ho-Sung;Park, Hee-Jin
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.06b
    • /
    • pp.476-481
    • /
    • 2007
  • 큰 소수를 빠르게 생성하기 위한 다양한 소수 검사 방법이 개발되었으며, 가장 많이 쓰이는 소수 검사 방법은 trial division과 Fermat (또는 Miller-Rabin) 검사를 조합한 방법과 gcd 연산과 Fermat (또는 Miller-Rabin) 검사를 조합한 방법이다. 이 중 trial division과 조합한 방법에 대해서는 확률적 분석을 이용하여 수행시간을 예측하고 수행시간을 최적화 하는 방법이 개발되었다. 하지만, gcd 연산과 조합한 방법에 대해서는 아무런 연구결과도 제시되어 있지 않다. 본 논문에서는 gcd 연산을 이용한 조합 소수 검사 방법에 대해 확률적 분석을 이용하여 수행시간을 예측하고 수행시간을 최적화 하는 방법을 제안한다.

  • PDF

Terahertz reflection nondestructive test by time analysis and short-time Fourier analysis (시간 분석 및 짧은 시간 구간별 주파수 분석을 이용한 반사형 테라헤르츠파 비파괴 검사)

  • NamGung, Chan;Cho, Sang-Heum;Ahn, Chang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2033-2034
    • /
    • 2011
  • 본 논문에서는 물체 내부를 파괴하지 않고 검사 할 수 있는 방식 중에 인체에 무해한 테라헤르츠파를 이용하여 짧은 시간 영역과 짧은 시간 주파수 영역을 분석하고, 집적회로 샘플을 대상으로 실험하였으며 짧은 시간 주파수 영역을 분석함으로써 비파괴 검사를 할 수 있다는 가능성을 제시하였다.

  • PDF

The Variation of Scan Time According to Patient's Breast Size and Body Mass Index in Breast Sentinel lymphangiography (유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화)

  • Lee, Da-Young;Nam-Koong, Hyuk;Cho, Seok-Won;Oh, Shin-Hyun;Im, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.62-67
    • /
    • 2012
  • Purpose : At this time, the sentinel lymph node mapping using radioisotope and blue dye is preceded for breast cancer patient's sentinel lymph node biopsy. But all patients were applied the same protocol without consideration of physical specific character like the breast sizes and body mass indexes. The purpose of this study is search the optimized scan time in breast sentinel lymphangiography by observing how much the body mass index and breast size influence speed of lymphatic flow. Materials and Methods : The Object of this study was 100 breast cancer patients(Female, 100 persons, average age $50.34{\pm}10.26$ years old)at Severance hospital from October 2011 to December 2011. They were scanned breast sentinel lymphangiography before operation. This study was performed on Forte dual heads gamma camera (Philips Medical Systems, Nederland B.V.). All patients were intra-dermal injected $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml. For 80 patients, we have scanned without limitation of scan time until the lymphatic flow from the lymph node since injection. We measured how long the lymphatic flow time between departures from injects site and arrival to lymph node using stopwatch. After we calculated patient's Body mass Index and classified as 4 groups. And we measured patient's breast size and classified 3 groups. The modified breast lymphangiography that changing scan time according to comparison study's result was performed on 20 patients and was estimated. Results : The mean scan time as breast size was A group 2.48 minutes, B group 7.69 minutes, C group 10.43 minutes. The mean scan time as body mass index was under weight 1.35 minutes, normal weight 2.56 minutes, slightly over 5.62 minutes, over weighted 5.62 minutes. The success rate of modified breast lymphangiography was 85%. Conclusion : As the Body mass index became higher and breast size became bigger, the total scan time is increased. Based on the obtained information, we designed modified breast lymphangiography protocol. At the cases applying that protocol, most of sentinel lymph nodes were visualized as lymphatic pool. In conclusion, we found that the more success rate in modified protocol considering physical individuality than study carrying out in the same protocol.

  • PDF

관능에 관여하는 의식요소와 식품관능평가의 시간함수개념

  • 전재근
    • Proceedings of the Korean Society of Food Science and Nutrition Conference
    • /
    • 2000.11a
    • /
    • pp.115-123
    • /
    • 2000
  • 식품의 관능검사는 인간의 의식과 식품간의 반응결과를 객관적으로 나타내는 방법으로 수치, 언어적 묘사, 도표 등의 표현법을 사용하고 있으며 검사 요원들 간의 오차를 발생한다. 이 오차를 줄이기 위하여 통계 및 심리학적으로 접근하여 해결을 시도해 오고 있으며 오차를 심리적 잡음 (psychological noise)이라고 주장되고 있다. 식품의 기호도는 감각신경세포에서 전기적 신호로 전환되어 뇌에 전달되고 의식의 분석과 해석을 거쳐 얻어지는 것이므로 전기적 신호처리가 포함된다. 그러나 현재의 관능검사 방법들은 시간의 함수관계를 중시하고 있지 않다. 감각신경의 신호 전달체계의 유사성을 바탕으로 관능검사과정에 시간함수를 도인하는 개념이 요구된다. 시간을 개입하는 방법론으로 의식과 식품간의 일어나는 순차적 또는 병열적 행동과 의식체계를 분석하고 시간인자의 중요성을 부각시켰다. 시간함수의 도입방법으로 관능영향인자 표의 구성하고 bar-code를 생성하는 프로그램과 파형곡선으로 전환하는 개념을 제안하였다.

  • PDF

찹쌀첨가량에 따른 백편의 조직감 특성의 변화

  • 이윤경;이효지
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.10a
    • /
    • pp.218.3-219
    • /
    • 2003
  • 백편을 만들 때 멥쌀가루 100에 찹쌀가루를 총중량의 0%, 5%, 10%, 15%, 20%, 25%, 30% 첨가하고 저장시간 0시간, 24시간, 48시간, 72시간 저장한 후 (4$^{\circ}C$에서) reheating 한 백편의 기호성과 조직감(Texture)에 어떠한 영향을 끼치는 가를 관능검사와 기계적 검사에 의해 측정한 결과를 다음과 같이 요약할 수 있다 1. 관능검사 결과 백편의 Color 는 찹쌀의 첨가량이 증가할수록 누런색이 짙어졌으며, 24, 48, 72 시간 저장한 후 reheating 한 백편도 누런색이 짙어지는 경향을 나타냈다. Coarseness 는 찹쌀의 첨가량이 증가할수록 증가하는 경향이었으나 저장전의 백편은 유의적인 경향을 나타내지 않았다. 찹쌀의 첨가량이 증가할수록 Softness, Dryness, crumblyness는 감소경향을 나타냈으며 24, 48, 72 시간을 저장한 후 reheating 한 백편도 유의적인 감소경향을 나타냈다. 외관의 기호도는 찹쌀의 첨가율이 5% 인 백편을 가장 좋아했고, 조직감 및 종합적인 기호도는 찹쌀의 첨가율이 10~20%인 백편을 좋아했다. 2. Rhemeter에 의한 백편의 Texture는 찹쌀의 첨가량이 증가할수록 Compression force, gumminess, Chewiness가 증가하는 경향을 나타냈다. 24, 48, 72 시간 저장한 후 reheating 한 백편은 저장전보다 점점 감소경향을 나타냈다가 72시간 저장한 후 reheating 하면 다시 증가경향을 나타냈다. Work ratio 및 Recovered height는 찹쌀의 첨가량과 저장시간의 변화에 크게 영향을 미치지 않았다. Recovered 하지 않고 0, 24, 48, 72 시간 저장한 백편의 Compressing force는 찹쌀의 첨가량이 증가할수록 증가경향이 컸고 저장시간이 경과함에 따라 Compression force가 증가하였는데 특히 24시간 저장하는 동안 급격히 증가하였다. 3. 찹쌀 첨가량이 증가할수록 수분함량은 증가하였고, 저장시간이 경과함에 따라 수분함량은 감소경향을 나타냈으나 24시간 저장한 후 reheating 한 백편만이 수분함량의 증가경향을 나타내었다. 4. qoruvs의 Softness 는 Compression force 및 Work ratio 와 유의적인 상관관계를 나타내었으며, Dryness 와 Crumblyness 는 Work ratio와 유의적인 상관관계를 나타내고 있어 백편의 조직감은 Compression force 와 Work ratio로 대치할 수 있을 것이라고 사료된다. 수분함량은 기계적 검사보다 관능검사와 더욱 높은 상관관계를 나타냈다.

  • PDF

Hearing Screening Test for High Risk Neonate (고위험군 신생아의 청각 스크린 검사)

  • Soh, Un-Ki;Na, Bak-Ju;Lee, Moo-Sik;Kim, Chul-Woung;Lim, Nam-Gu
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.599-602
    • /
    • 2009
  • 본 연구는 2006년 3월부터 2007년 2월까지 일개 대학병원에서 출생한 고위험군 신생아 121명을 대상으로 청각선별검사인 자동화 유발이음향방사와 확진검사인 청성뇌유발전위검사를 실시하여 임상양상과 청각장애 발생률, 검사소요 시간에 대해 조사하였다. 결과는 다음과 같다. 1. 청각장애발생률은 전체 고위험군 신생아 121명 중 5명의 신생아가 난청으로 조기에 진단되었다. 2. 난청으로 확진 받은 신생아 5명의 관련 질병을 살펴보면 고빌리루빈혈증 2명, 저체중 1명, 구개열 1명, 다운증후군 1명이었다. 3. 난청으로 확진 받은 신생아 5명의 청력손실정도는 양측 고도난청 1명(70dB), 양측 중도난청 2명(55dB), 편측성 난청 2명으로 나타났다. 4. 검사소요 시간은 선별검사인 유발이음향방사 검사를 실시하는 데 소요된 총 시간의 평균은 $107.5{\pm}65.2$초였고, 확진검사인 청성뇌유발전위 검사를 실시하는 데 소요된 총 시간의 평균은 $1,500{\pm}90.1$초가 소요되었다. 5. 연구를 진행하는 도중 11명의 고위험군 신생아가 이사, 연락처 변경, 경제적 사정으로 추적검사에 참여하지 않았다. 신생아 난청은 다른 질병에 비해 발병률이 높은 선천성 질환으로서 모든 신생아를 대상으로 청각검사를 실시하여 난청의 조기진단에 대한 선별검사의 정착이 필요하다고 생각된다.

  • PDF

Radiological Perspectives for Diagnosis of Vasospastic Angina with Coronary Angiography (이형성 협심증 진단 조영 검사의 방사선학적 관점)

  • Jong-Gil Kwak;Young-Hyun Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.589-595
    • /
    • 2023
  • If complete coronary artery occlusion occurs due to severer coronary spasm, malignant arrhythmias can lead to death. Therefore, early screening for coronary artery spasm angina is essential. Among the test methods, the drug injection test through coronary angiography is generally performed. Therefore, the purpose of this study was to evaluate the advantages of ergonovine drug test for vasospasitc angina examination during coronary angiography, such as the relationship between the procedure time, contrast medium usage, and radiation exposure effects of coronary angiography. Follow-up data of 142 patients who underwent coronary angiography and variant angina examination from september 2021 to february 2023 were used. As a result of analyzing contrast usage dose and dose area product and air kerma dose and number of imaging series and procedure time, variant angina examination was statistically significantly higher than coronary angiography. (p<0.001) In conclusion, variant angina examination other than coronary artery angiography are radiologically negative. Therefore, we think it is better to avoid excessive inspection. Nevertheless, in the case of the provocation test, the longer the examination time, the higher the fluoroscopy time and the amount of contrast medium used, so it is better to conduct the test as quickly as possible or shorten it.