• Title/Summary/Keyword: 검사 결과

Search Result 16,659, Processing Time 0.047 seconds

Usefulness Evaluation 'Ankle Stress View Compared with MRI scan' of Subacute Ankle Sprain (아급성기 발목염좌에 대한 Stress View와 MRI검사 대비 유용성 평가)

  • Ahn, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.201-205
    • /
    • 2011
  • Subacute Ankle Sprain patients, 3 tests have been acknowledge for diagnostic precision and thus most commonly used to test their soft tissues, muscles, and ligaments: ankle stress-valgus test, anterior-draw test, and MRI scan. Although not much different from the rest two in its diagnostic value, MRI costs patients some money and time. Also, we have reached the conclusion through an experiment with a group of patients in a certain hospital that the rest two methods is as efficient and useful as MRI in diagnosing ankle joint patients.

Program Implementation for Efficient Calibration Management of Measuring Instruments (효율적 계측기기 교정검사 관리를 위한 프로그램 구현)

  • Roh, Su-Sung;Lee, Chil-Gee
    • Annual Conference of KIPS
    • /
    • 2005.05a
    • /
    • pp.727-730
    • /
    • 2005
  • 계측기기의 사용업체들은 기기 관리부분 및 교정검사 주기가 상이한 계측기기 교정검사 관리부분의 어려움으로 인하여 교정검사 유효기간을 지나치는 경우가 많았으며, 국가교정검사 기관은 각 계측기기의 측정 데이터 결과 형식이 달라 교정검사 후 발행하는 성적서의 작성 및 발행 하는데 어려움이 많았다. 또한 계측기기 사용업체와 교정검사기관 모두 관리 프로그램과 교정검사 성적서 관리 프로그램을 별도로 사용하였다. 이러한 계측기기 및 성적서 관리를 하나의 시스템으로 쉽게 통합관리 할 수 있도록 구성 하였으며, 각각의 상이한 계측기기 주기 정보를 데이터베이스화 하여 주기별, 측정기기별, 업체별 검색 및 자동 팝업창으로 상태를 알려주게 하였고, 계측기기별 상이한 형식의 측정 데이터는 부서별, 유형별로 데이터베이스화 하여 응용프로그램과 연동될 수 있도록 구현 하였다. 계측기기 관리 및 교정검사 관리 부문에 있어서 사용 대상에 따라 GUI 환경으로 구현된 프로그램으로서 기본설정을 통하여 교정대상업체 및 교정검사기관 모두 하나의 통합된 프로그램으로 사용 및 관리를 할 수 있다.

  • PDF

Fabrication of Mechanical fatigue flawed Specimen and Evaluation of Flaw Size (기계적 피로결함 시험편 제조 및 결함 크기 평가)

  • Hong, Jae-Keun;Kim, Woo-Sung;Son, Young-Ho;Park, Ban-Uk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.38-44
    • /
    • 2003
  • Performance demonstration with real flawed specimens has been strongly required for nondestructive evaluation of safety class components in nuclear power plant. Mechanical or thermal fatigue crack and intergranular stress corrosion cracking could be occured in the in-service nuclear power plant and mechanical fatigue crack was selected to study in this paper. Specimen was designed to produce mechanical fatigue flaw under tensile stress. The number of cycles and the level of stress were controlled to obtain the desired flaw roughness. After the accurate physical measurement of the flaw size and location, fracture surface was seal-welded in place to ensure the designed location and site. The remaining weld groove was then filled by using gas-tungsten are welding(GTAW) and flux-cored arc welding(FCAW). Results of radio graphic and ultrasonic testing showed that fatigue cracks were consistent with the designed size and location in the final specimens.

Analysis at Effects of Task Skills on Osteoporosis Tests (업무 숙련도가 골다공증 검사에 미치는 영향 분석)

  • Kim, Hyeon-Jin;Kim, Won-Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.31-37
    • /
    • 2020
  • This study was conducted to examine the kinds and the frequency of incorrect outcomes occurring depending examiners' skills, in testing osteoporosis by using Dual Energy X-ray Absorptiometry(DXA) and improve frequently occurring errors by educating them. The results of an analysis show that the outcomes from the test of hips in patients with wrong postures or some regions with pressure fracture and degenerative changes were often included, even though they should be excluded, and that surgical instruments were also included in the analysis, though they should be excluded from resulting values. Of them, the errors most often found were those about patients' postures (n=56, 6 cases for spines and 50 cases for hips), followed by those about analytical processes (n=37, 35 cases for spines and 2 cases for hips), and then those about regions of interest (n=33, 28 cases for spines and 5 cases for hips). There were, however, no errors caused by the defectiveness of quality control.

A Case of Canine Uterine Adenocarcinoma with Negative Estrogen and Progesterone Receptor Expression (개의 에스트로겐과 프로케스테론 수용체 발현이 되지 않은 자궁 선암종 증례)

  • Cho, Hyang-Mi;Kim, Hyun-Wook;Kim, Hye-Jin;Choi, Ji-Hye;Jang, Jae-Young;Choi, Ul-Soo
    • Journal of Veterinary Clinics
    • /
    • v.28 no.3
    • /
    • pp.303-306
    • /
    • 2011
  • A 12-year-old female mixed breed dog receiving a progesterone drug was referred for evaluation of an abdominal mass. Abdominal radiography and ultrasonography revealed a swollen uterus and an associated mass. Serum chemistry revealed hyperglobulinemia consistent with acute inflammation based on the results of serum protein electrophoresis. Fine needle aspiration of the mass guided by ultrasonography was performed for cytological evaluation. The cytological impression was consistent with adenocarcinoma. Exploratory laparotomy identified a uterine body mass, which was surgically removed for histopathology. Histology of the mass identified a uterine adenocarcinoma. Immunochemistry using anti-estrogen and progesterone receptor antibodies was performed and neoplastic cells were negative to both antibodies while some normal elements were reactive to both of them. Computer tomography demonstrated evidence of metastatic disease in the lung one week after the surgery and the dog died about 40 days after surgery.

The Study of Nondestructive Test about Impact Damage of Plate Composite Materials (판형 복합재료의 충격 손상에 대한 비파괴시험적 고찰)

  • 나성엽;김재훈;최용규;류백능
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.4
    • /
    • pp.20-30
    • /
    • 2001
  • This study represents the Nondestructive Test about impact damage of composite materials made by different lay-up patterns and degrees. For this study, they were examined by the drop test on composite materials of two type lap-up patterns with fabric and unidirectional prepreg and examined nondestructive test of those. Nondestructive methods were X-ray test with $ZnI_2$ penetrant and Ultrasonic C-scan. The defect detectability of X-ray and Ultrasonic test was compared according to defect species. And the amounts of damage on impacted zone wert compared according to impact energy on two type test specimens. At results, Ultrasonic test was more effective to detect delamination and Penetrant X-ray test was more effective to detect matrix crack and fiber fracture. There were some differences in defect shapes and grades according to lay-up patterns and degrees, and the trend appeared that matrix crack, delamination, fiber fracture occured and increasing defects sizes according to increasing impact energy.

  • PDF

Eddy Current Bobbin Probe Design for Steam Generator Tubes in NPPs (원전 증기발생기 전열관 와전류검사 보빈탐촉자 설계)

  • Nam, Min-Woo;Lee, Hee-Jong;Jee, Dong-Hyun;Jung, Jee-Hong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.89-96
    • /
    • 2007
  • The bobbin probe examination is basic and the important method among other ECT techniques for the steam generator tube integrity assesment that is practiced during each plant outage. The bobbin probe is one of the essential components which consist of the whole ECT examination system, and provides us a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of examination probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has enormous effects on examination results. In this study, An optimal differential bobbin probe is designed for the steam generator tube inspection in nuclear power plants(NPPs). Based on the test results for electrical and ECT signal characteristics, the prototype bobbin probe satisfies all the criteria.

자유곡면을 위한 CAD지향 측정시스템

  • 박희재;김영호;홍예선
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1992.04b
    • /
    • pp.309-317
    • /
    • 1992
  • 현재 3차원 좌표측정기(Coordinate Measuring Machine:CMM)는 기계가공품의 수치검사(Dimensional inspection)에 널리 사용된다. 검사과정의 자동화를 향상시키기 위해 CMM을 이용한 컴퓨터통합검사시스템이 필요하게 되었다. 이 논문에서는 자유곡면 형상에 대해 CAD지향의 검사개념을 사용하여 CMM을 이용 자동측정하고 그 결과를 토대로 측정한 자유곡면에 대한 형상오차를 분석하는 부분을 다룬다.

  • PDF

Implementation of Automated Defect Detection and Classification System for Semiconductor Wafers (반도체 웨이퍼 자동 결함 검출 및 분석 시스템 구현)

  • 남상진;한광수
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.10b
    • /
    • pp.334-336
    • /
    • 2001
  • 반도체 제조와 같은 대량 생산 시스템에서 제품 검사는 매우 중요란 단계 중의 하나이다. 반도체 제조 공정 내에서의 시각 검사는 현재 사람의 육안에 주로 의존하고 있으나, 회로가 점점 복잡해지고 작아지는 추세에 비추어 볼 때 사람에 의한 시각 검사는 한계에 이를 것으로 보인다. 본 연구에서는 웨이퍼상의 결함을 자동으로 검출하고 검출된 길함을 분류하는 자동시각검사 시스템을 설계 구현하였다.

  • PDF

건강검사에서 가장 받고 싶은 것은 간기능 검사

  • KOREA ASSOCIATION OF HEALTH PROMOTION
    • 건강소식
    • /
    • v.14 no.9 s.142
    • /
    • pp.34-37
    • /
    • 1990
  • 생활이 복잡다단해지면서, 사람들의 건강문제 특히 성인병의 문제는 한층 심각하게 다가오고 있으며 그만큼 사람들의 건강에 대한 관심도 증대되었다. 그럼에도 불구하고, 건강관리를 위한 검사를 정기적으로 해보겠다는 생각을 가진 사람은 의외로 적다. 건강관리협회가 ‘89년에 이어, 본회 내원자 500명을 대상으로 실시한 설문조사를 통해 이러한 결과를 알 수 있었는데, 이번 설문조사에서는 특히, 사람들이 매스콤을 통해 여러 차례 알려진 주요사망원인과 관련된 질환에 대해 많은 관심을 가져 매스콤의 국민건강에 대한 역할을 실감케 해 주었다.

  • PDF