• Title/Summary/Keyword: 검사 결과

Search Result 16,659, Processing Time 0.047 seconds

Selection of Unnecessary Urine Culture Specimens Using Sysmex UF-5000 Urine Flow Cytometer (Sysmex UF-5000 소변 유세포분석기를 이용한 요배양 불필요 검체의 선별)

  • Song, Duyeal;Lee, Hyun-Ji;Jo, Su Yeon;Lee, Sun Min;Chang, Chulhun L.
    • Annals of Clinical Microbiology
    • /
    • v.21 no.4
    • /
    • pp.75-79
    • /
    • 2018
  • Background: Urine culture is one of the most frequently requested tests in microbiology. Automated urine analyzers yield much infection-related information. The Sysmex UF-5000 analyzer (Sysmex, Japan) is a new flow cytometry urine analyzer capable of quantifying urinary particles, including bacteria, WBCs, and yeast-like cells (YLCs) and can provide a Gram stainability flag. In this work, we evaluated how many unnecessary urine cultures could be screened out using the UF-5000. Methods: We compared the culture results of 126 urine samples among 453 requested urine cultures (from sources other than the Urology and Nephrology departments) with urinalysis results. Urine cultures were considered positive if bacterial or YLC growth was ${\geq}10^4CFUs/mL$. Results: We used urinalysis cut-off values of $50/{\mu}L$ and $100/{\mu}L$ for bacteria and YLC, respectively. Forty eight of the 126 (38.1%, or 10.6% of 453 requested) cultures were below these cut-off values and did not contain any culture-positive samples. Conclusion: Bacteria and YLC counts generated using the UF-5000 analyzer could be used to screen out negative cultures and reduce urine culture volume by ~10% without sacrificing detection of positive cultures.

A Study on the Validity of the Grit Test as a Tool for Identification of Mathematically Gifted Elementary Students (초등수학영재 판별 도구로서 그릿 검사 타당성 검증)

  • Heo, Jisung;Park, Mangoo
    • Communications of Mathematical Education
    • /
    • v.36 no.3
    • /
    • pp.355-372
    • /
    • 2022
  • The purpose of this study was to find out whether the Grit test is valid as a test tool for Identification of mathematically gifted elementary students. For this study, we conducted Grit tests, Mathematical Problem Solving Aability Tests, Mathematical Creative Ability Tests, and Mathematically Gifted Behavior Characteristic Tests on 39 ordinary students at Seoul public elementary school and 20 mathematically gifted students at the Education Center for Gifted Education, and analyzed correlation with each test. In addition, we conducted a discriminant analysis to find out how the Grit test can accurately determine the members of the mathematically gifted student group and the ordinary student group. As a result of Pearson's correlation analysis, the Grit test was .521 with the Mathematical Problem Solving Ability Tests, .440 with the Mathematical Creative Ability Tests, and .601 with the Mathematically Gifted Behavior Characteristic Tests, according to significant positive correlation at p<.01. Through this, it can be confirmed that the Grit test has a high official validity as a tool for determining mathematically gifted students. As a result of conducting a discriminant analysis to confirm the classification discrimination ability of the elementary mathematically gifted student group and ordinary student group of the Grit test, Wilk's λ was .799(p<.001). We confirm that the Grit test is a significant variable in determining the mathematically gifted student group and ordinary student group. In addition, 64.4% of the entire group was accurately classified as a result of group classification through discriminant analysis. This shows that the Grit test can be actually used as a test tool to determine mathematically gifted elementary students.

Development of the Defect Inspection Equipment for Mobile TFT-LCD Modules (Mobile용 TFT-LCD 화면 검사장비 개발)

  • Koo, Young-Mo;Hwang, Man-Soo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.2
    • /
    • pp.259-264
    • /
    • 2009
  • High level quality control is required for mobile TFT-LCD modules which are frequently used for fine observation. However, quantitative quality control is difficult. Defect inspection using naked eyes makes irregular inspection results. This paper developed desk type defect inspection equipment for mobile TFT-LCD modules using the same inspection criterion with that of naked eyes. From experiments using this equipments, possibilities of standardization in defect inspection equipment for mobile TFT-LCD modules are presented.

System Implementation for Automatic Inspection of Wind Pressure Sensor Based on Reliability Improvement (신뢰성 향상 기반의 풍압센서 자동검사 시스템구현)

  • Do, Nam Soo;Ryu, Conan K.R.
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.775-778
    • /
    • 2017
  • This research describes system implementation for automatic inspection on wind pressure sensor production based on reliability improvement. The reliability is minimized by the automatic inspection system on the wind pressure sensor against the manual system. The system consists of the control system and monitoring system to be scanning the inspection processing. The inspection system for reliability is evaluated in Gage Repeatability and Reproducibility. The experimental results are improved about 2 times speed, measured error ${\pm}0.02V$, effectiveness 15%, missing probability 17% and false alarm 12% respectively. The system will be also improved by database and the product barcodes for the total quality control system based on the effective reliability in the future.

  • PDF

Diagnostic Usefulness of Quantitative Sensory Test Comparison with Photoplethysmography (광용적맥파와 정량적 감각검사의 비교를 통한 진단적 유용성)

  • LEE, Sang-Bong;SEO, Jeong-Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.315-322
    • /
    • 2015
  • The purposes of this study were to compare the sensitivities of two tests, QST(quantitative sensory test)and PPG(photoplethysmography) in normal adults. We evaluated the sensory thresholds of QST and PPG and diabetes mellitus test in 17 normal adults. The finding of this study can be summarized as follow :The diagnostic sensitivities of QST was similar to PPG. There is a direct correlation between the amount of Blood sugar and parasympathetic nerve in ANS. Concluded that the QST might be complement to NCS for early of diabetic polyneuropathy. A new diagnostic approach, QST was introduced and exploited for diagnosis. This study provides support for PPG performed a ANS analysis.

Comparing the Change in SUVmax Over Time by the Type of Ductal Breast Carcinoma (유방암 환자 중 유관에서 발병되는 암의 종류(IDC와 DCIS)별 시간경과에 따른 SUVmax 변화에 대한 비교)

  • Hyoung, Mi-Jin;Kim, Jeong Nip;Moon, Pyeong Soo;Kim, Kil Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.140-144
    • /
    • 2014
  • Purpose: The recent surge in breast carcinoma patients is reported in a variety of statistics. Breast cancer occurs mainly from duct and lobulus: 85% is from the breast ducts. The present study is aimed to distinguish the difference in $SUV_{max}$ changing over time by identifying the type of cancers attacking from the duct. Materials and Methods: The subjects of the study are 291 female breast cancer patients who have visited the present PET/CT center from July 1, 2012 to July 23, 2013. Based on the pathological results, 248 IDC (invasive ductal carcinoma) patients and 43 DCIS (ductal carcinoma in situ) patients were selected. In the same manner as the general PET/CT scan (3.7 MBq/Kg), F-FDG was injected, followed by the primary test (Routine tests) after 1 hr, and the secondary test (Delay test) after another hr. $SUV_{max}$ was measured after setting ROI in the lesion based on the data from the two tests. Results: As the comparative result of the change in the lesion $SUV_{max}$ between the two groups, IDC group's $SUV_{max}$ showed M=7.11 and SD=5.405 in the primary test and increased M=7.11 and SD=5.405 in the secondary test (P<0.05); DCIS group's $SUV_{max}$ showed M=2.739, SD=1.229 in the primary test and increased M=2.614, SD=1.470 in the secondary test (P<0.05). Conclusion: As the comparative result of $SUV_{max}$ over time between the groups, IDC showed increased $SUV_{max}$ in the secondary test (Delay test) compared to the primary test (Routine test) (P=0.000); DCIS showed decreased $SUV_{max}$ in the secondary test (Delay test) compared to the primary test (Routine test) (P=0.039). It was confirmed through this study that the change in $SUV_{max}$ has occurred over time by the type of breast cancer (IDC or DCIS) occurring from the breast ducts. However, the onset of breast cancers (ILC, LCIS) from the lobulus was not discussed due to the lack of samples. Future research on the breast cancers from the lobulus is suggested.

  • PDF

Comparison of the Right-to-left Shunt Test by Transcranial Doppler Based on the Addition of Blood and Patient Posture (경두개 초음파를 이용한 좌우단락검사 시 Blood 사용 유무와 환자 자세에 따른 실증적 결과 비교)

  • Kun-Woo KANG;Eui-Jeong LEE;Hyun-Kyung LEE;Eun-Son LEE;Yang-Hee LIM
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.3
    • /
    • pp.228-235
    • /
    • 2024
  • Using transcranial doppler ultrasonography (TCD) to measure the presence or absence of abnormalities in patent foramen ovale (PFO) is more effective than transesophageal echocardiography (TEE) because it is simple, inexpensive, and non-invasive. Thus, it can be a good alternative test in cases where it is difficult to perform TEE or in groups at a high risk of complications. Therefore, in this study, we sought to assist in arriving at a diagnosis by suggesting an appropriate method through the comparison of empirical results according to the presence or absence of blood use and varying patient posture. The results were compared depending on the patient's posture and whether blood was used. Patients in whom both middle cerebral arteries were observed were targeted. In cases where the temporal window was defective, it was replaced with basilar artery and compared. There were higher positivity rate and accuracy for sitting position using valsalva maneuver (VM) than for Resting and supine position using VM. Therefore, if it is possible to perform a sitting position using VM with a mixture of blood, it would be a good idea to perform it.

Evaluation of a Rapid Diagnostic Antigen Test Kit Ribotest Mycoplasma® for the Detection of Mycoplasma pneumoniae (Mycoplasma pneumoniae 감염의 신속 항원 검사 키트 "Ribotest Mycoplasma®"의 진단적 평가)

  • Yang, Song I;Han, Mi Seon;Kim, Sun Jung;Lee, Seong Yeon;Choi, Eun Hwa
    • Pediatric Infection and Vaccine
    • /
    • v.26 no.2
    • /
    • pp.81-88
    • /
    • 2019
  • Purpose: Early detection of Mycoplasma pneumoniae is important for appropriate antimicrobial therapy in children with pneumonia. This study aimed to evaluate the diagnostic value of a rapid antigen test kit in detecting M. pneumoniae from respiratory specimens in children with lower respiratory tract infection (LRTI). Methods: A total of 215 nasopharyngeal aspirates (NPAs) were selected from a pool of NPAs that had been obtained from children admitted for LRTI from August 2010 to August 2018. The specimens had been tested for M. pneumoniae by culture and stored at $-70^{\circ}C$ until use. Tests with Ribotest $Mycoplasma^{(R)}$ were performed and interpreted independently by two investigators who were blinded to the culture results. Results: Among the 215 NPAs, 119 were culture positive for M. pneumoniae and 96 were culture negative. Of the culture-positive specimens, 74 (62.2%) were positive for M. pneumoniae by Ribotest $Mycoplasma^{(R)}$, and 92 of the 96 (95.8%) culture-negative specimens were negative for M. pneumoniae by Ribotest $Mycoplasma^{(R)}$. When culture was used as the standard test, the sensitivity and specificity of Ribotest $Mycoplasma^{(R)}$ were 62.2% and 95.8%, respectively. Additionally, the positive predictive value, negative predictive value, and overall agreement rates with Ribotest $Mycoplasma^{(R)}$ were 94.9%, 67.2%, and 77.2%, respectively. Conclusions: A positive test result of Ribotest $Mycoplasma^{(R)}$ suggests a high likelihood of culture-positive M. pneumoniae infection. However, a negative test result should be interpreted with caution because nearly one-third of negative test results reveal culture-positive M. pneumoniae infections.

Diagnostic Imaging of Liver Cirrhosis in a Shih-Tzu Dog (시츄견에서 발생한 간경화의 영상 진단)

  • Choi, Ho-Jung;Lee, Ki-Ja;Chang, Jin-Hwa;An, Ji-Young;O, I-Se;Ahn, Se-Joon;Jeong, Seong-Mok;Park, Seong-Jun;Cho, Sung-Whan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.26 no.4
    • /
    • pp.367-370
    • /
    • 2009
  • A 5-year-old, intact female Shih-Tzu dog was presented with 1 year history of icterus, ascites and anorexia. The serum biochemistry revealed elevated liver enzyme levels. Microhepatica and decreased serosal detail were detected in abdominal radiography. Abdominal ultrasonographic findings included irregular liver margins, multifocal hypoechoic nodules in the liver parenchyma, and ascites. Computed tomography (CT) showed multifocal hypodense nodules with ring-like contrast enhancement. Cytologic and histopathologic examination by liver core biopsy revealed fibrosis. Cirrhosis was diagnosed based on above results. This report focuses on the imaging characteristics of ultrasonography and CT for liver cirrhosis in a dog.

A defect inspection method for the LCD ploarizer film using statistical moment of histogram (히스토그램의 통계적 모멘트를 이용한 편광필름 결함 검출 방법)

  • Yoon, Hee-Sang;Park, Tae-Hyoung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1760-1761
    • /
    • 2007
  • 액정 디스플레이(LCD)의 핵심 재료인 편광필름은 제조 과정이나 운반 과정에서 실오라기 같은 이물 및 찍힘 등의 결함이 발생하며 이를 사람이 육안으로 검사하고 있다. 본 논문에서는 이런 편광필름의 결함을 자동으로 검출하기위한 방법으로 히스토그램의 통계적 모멘트를 사용하여 주변 밝기에 따라 검사 영역의 밝기의 기울기를 구하고, 이를 통해 결함의 유무를 판단하는 편광필름 검사 방법을 제안한다.

  • PDF