• Title/Summary/Keyword: 검사각도

Search Result 194, Processing Time 0.026 seconds

Development of Automatic Visual Inspection System for Micro Needle (미세 탐침의 비전 자동 검사 시스템 개발)

  • Kang, Su-Min;Han, Kwang-Hee;Huh, Kyung-Moo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.16-25
    • /
    • 2008
  • The micro needle means the ultrafine probe of 'Probe Card'. The size of micro needle is so minute that it is difficult to minute that it is difficult to inspect it with eyes. On the other hand it is very critical if there is a defect in micro needle of probe card. In this study, we developed an automatic visual inspection system for finding defect status in probe angle, tip length and diameter. Through the experimental results, we could find that our proposed method is better than human-eyes inspection method in accuracy and inspection speed, and also in robustness to lighting circumstances.

A Study on Measuring the Temperature and Revising the Result When Measuring the Temperature of NPP Pipes Using Infrared Thermography (적외선 열화상 기술을 이용한 원자력 배관의 온도측정과 보정에 관한 연구)

  • Kim, Kyeong-Suk;Jung, Hyun-Chul;Pack, Chan-Joo;Kim, Dong-Soo;Jung, Duk-Woon;Chang, Ho-Sub
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.421-426
    • /
    • 2009
  • The emissivity is different because the emitted angle changes according to the position of the infrared thermography camera and object. Because of this, the temperature distribution expressed when measuring the temperature by using the infrared thermography system is not the accuracy temperature. Although the real surface temperature is constant, the temperature measured by using infrared thermography camera have error in accordance with the value of emissivity. In this paper, the temperatures of the round cylindrical object and the flat square object that heated to the equal temperature were measured by infrared thermography camera. The emissivity calibration formula and correction table are made with the affect of the view angle and emission angle form the surface temperature value. The error of measured temperature values are corrected by using the emissivity calibration formula and correction table, and apply to defect detection of the nuclear power plant pipe. From the calibration method, reliability surface temperature values were obtained.

The Diagnosis of Rheumatologic and Degenerative Arthritis by X-ray Sacroiliac Joint Projection (X-ray 엉치엉덩관절 촬영법을 통한 류마티스 및 퇴행성관절염 진단)

  • Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.397-402
    • /
    • 2018
  • The study best image for diagnosis of fracture, dislocation and unilateral degenerative arthritis of the Sacroiliac joint, this study was performed to obtain the best image of the joint space of the hip joint by giving angle change to the pelvis phantom and the x-ray tube. I received evaluation. The results of the Receiver Operating Characteristic that in the case of simple photographs for the detection of joint arthritis and degenerative arthritis in the prone position, the photograph taken in the prone position raises the buttocks of the opposite side of the test by $25^{\circ}{\sim}30^{\circ}$ and the x-ray tube is perpendicular to the sagittal plane passing 2.5 cm inward from the thorny vertebra In the lying position, lift the Sacroiliac joint of the test side by $25^{\circ}{\sim}30^{\circ}$, and take a $5^{\circ}$ angle of the x-ray tube angle toward the foot toward the center of the upper bruch spine from it will be helpful to diagnose arthritis. the center of the upper bruch spine to the side of the ankle joints in the transverse direction And posterior direction, it will be helpful to diagnose arthritis.

A Study on the Angle between the Abdominal Aorta and the Superior Mesenteric Artery by 3D Image Reconstruction (3D 영상 재구성을 통한 복부대동맥과 상장간막동맥과의 각도에 관한 연구)

  • Kim, Young-Keun;Choi, Sung-Kwan
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.63-70
    • /
    • 2003
  • SMAS(Superior Mesenteric Artery Syndrome) is a disease caused by a chronic obstruction of the duodenum(transverse portion), which is hardly detectable. However, it is known that when the superior mesenteric artery and abdominal aorta form a narrow angle, that the transverse portion of the duodenum is pressed down between the superior mesenteric artery and the abdominal aorta, and that this can lead to obstruction of the duodenum. Measuring this angle is a complicated job using conventional angiography, and results often turns out to be inaccurate. In addition, no attempt has been made to determine the value of this angle in Koreans. In this study, we conducted abdominal CT angiography using MIP(maximum intensity projection) on patients with no clinical evidence of SMAS in order to determine the angle at which the superior mesenteric artery branches from the abdominal aorta by using PC based software(Rapidia ver. 1.2) for the image reconstruction. Accordingly, we found that the mean angle between the abdominal aorta and the superior mesenteric artery was $50.05{\pm}15.87^{\circ}$ on average, and that the angle in men($53.64{\pm}16.57^{\circ}$) is higher than in women($46.46{\pm}14.98^{\circ}$). We hope that the angles determined by our study will serve as an important indicator for detecting SMAS.

  • PDF

Effects of Knee Position during the Graft Fixation of the Arthroscopic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Graft (이식 건 고정 시 슬관절 위치가 자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 후 결과에 미치는 영향)

  • Lee, Churl-Woo;Yoo, Jae-Doo;Roh, Kwon-Jae;Park, Seong-Pil
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.143-147
    • /
    • 2005
  • Purpose: In case of anterior cruciate ligament (ACL) reconstruction, graft tendon is generally fixed in tibial tunnel with knee extended. When reconstructing ACL using hamstring tendon, the authors aim to find out the effect of knee joint position during graft fixation on postoperative knee joint stability and range of motion. Materials and Methods: Prospective study was done on patients who have undergone ACL reconstruction using hamstring tendon from May 2002 to January 2003 We used Rigifix system (Mitek Product, Johnson and Johnson, USA) and Intrafix system for fixation. Thirty nine patients received ACL reconstruction during this period. Excluding 2 patients lost in the follow-up, 37 patients were analyzed. The mean follow-up period was 14 months $(13{\sim}25months)$. Knee position was decided alternatively without any bias. Clinical evaluation was based on Lachman test, pivot shift test, Lysholm score, IKDC(international knee documentation committee) assessment and side to side KT-1000 maximal manual arthrometer difference. Results: After the last follow-up, average postoperative Lysholm score was 93.1 poins(65-98points). According to IKDC score, 26 cases were normal, 10 cases were nearly normal, 1 case was abnormal and we had no case of severe abnormality. The mean difference from the normal side was 2.5 mm under maximal manual loading KT-1000 arthrometer. According to postoperative Lachman test, 32 cases were normal,2 cases were grade I and 1 case was grade II. There were 34 cases of normal, 2 cases of grade I and 1 case of grade II. When using maximal manual KT-1000 arthrometer side to side difference, the difference from the normal side while fixing the tibia at 20'knee flexion was 2.3 mm and at full extention the difference was 2.7 mm. The range of motion at postoperative 1 year showed 5 degree flexion contracture in 1 case at 20 degrees knee flexion and 10 degrees of flexion limitation was observed in 2 cases at full extension. Conclusion: When ACL reconstruction using autogenous hamstring tendon, anterior laxity showed no difference in its stability between two groups. Tibial side fixation at full extension may be helpful in preventing flexion contracture due to overconstrained graft tendon.

  • PDF

A Study of Tube Angle and Patient's Rotation Angle in Scapular Y View (어깨뼈 후전사방향촬영에서 Tube 각도와 환자의 회전각도 관한 연구)

  • Ahn, ByeoungJu;Lee, JunHaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.271-275
    • /
    • 2013
  • Shoulder bone scan everyday life, sports activities at the side of the shoulder joint, or applying strong force in the lateral occurs. Mainly on upper arm abduction, temple, other rotational dislocation of the shoulder joint gahaejyeo as useful for observing the presence or absence of lesions is used. Shoulder PA oblique projection prevent distortion of the image due to the angle and the most useful diagnostic radiological investigate shooting angle. Shoulder blade body and the acromion and coracoid process Y-view is formed characters. $10^{\circ}$ angle between the shoulder blades and the acromion is the obstruction. $20^{\circ}{\sim}25^{\circ}$ to the Y-view of the humerus head looks superimposed, the position of the shoulder joint and seemed appropriate. $35^{\circ}$ of the humerus head superimposed on the Y-view, but above the humerus head and shoulder joints were distorted. When $45^{\circ}$ elevation observed on the side of the best has come Y-view also acromion and coracoid process is finished.

Urinalysis Screening Application based on Smartphone (스마트폰 기반 요검사 스크리닝 애플리케이션)

  • Baek, Seung-Hyeok;Choi, Hong-Rak;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.5
    • /
    • pp.95-102
    • /
    • 2021
  • The urinalysis, which is universally accessible to the general public, has disadvantages of being less objective using sight and purchasing a separate portable urinalysis machine. However, due to the high penetration rate and performance improvement of smartphone created by the development of mobile communication technology, research on urinalysis services using smartphone has been conducted. In this paper, a new urinalysis screening application based on smartphone was developed by supplementing the limitations of the previously studied urinalysis services. The key technology of the application is urinalysis recognition algorithm and urinalysis pad color determination algorithm through image-processing and contour detection. In order to confirm the performance of the developed application, urinalysis strip was photographed and analyzed from various backgrounds and angles.

A Study on Projection Angles for an Optimal Image of PNS Water's View on Children (유.소아 부비강 Water's 영상의 이상적 구현을 위한 촬영기준각도 변화에 관한 연구)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Sung-Kyu;Hong, Sang-Woo;Kim, Je-Bong
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.105-111
    • /
    • 2007
  • This study is to calculate the proper angle for the optimal image of PNS Water's view on children, comparing and analyzing the PNS Water's projection angles between children and adults at every age. This study randomly selected 50 patients who visited the Medical Center from January to May in 2005, and examined the incidence path of central ray, taking a PNS Water's and skull trans-Lat. view in Water's filming position while attaching a lead ball mark on the Orbit, EAM, and acanthion of the patients's skull. And then, we calculated the incidence angles(Angle A) of the line connected from OML and the petrous ridge to the inferior margin of maxilla on general(random) patients's skull image, following the incidence path of central ray. Finally, we analyzed two pieces of the graphs at ages, developing out the patients' ideal images at PNS Water's filming position taken by a digital camera, and calculating the angle(Angle B) between OML and IP(Image Plate). The angle between OML and IP is about $43^{\circ} in 4-years-old children, which is higher than $37^{\circ}, as age increases the angle decreases, it goes to $37^{\circ} around 30 years of age. That is similar result to maxillary growth period. We can get better quality of Water's image for children when taking the PNS Water's view if we change the projection angles, considering maxillary growth for patients in every age stage.

  • PDF

Development of an optical hologram Inspection system for counterfeit money discrimination (위폐 판별을 위한 홀로그램 광학 검사 시스템 개발)

  • Seo, Hye-Yeong;Kwon, Hyuk-Joong;Lee, Gu-Youl;Park, Tae-Hyoung
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.163-164
    • /
    • 2007
  • 위폐 판별을 위한 홀로그램 광학 검사 시스템을 제안한다. 이 시스템은 홀로그램의 표준패턴을 생성을 CGH(Computer Generated Hologram)방법에 근거한 주파수 변환을 적용하고, 조명각도에 따라 홀로그램 이미지를 정확하게 획득하여 특성에 적합한 홀로그램 표준패턴을 생성하게 된다. 생성한 표준패턴과 실제 영상과의 패턴매칭을 위해 패턴매칭알고리즘을 적용하여 위폐를 판별하는 검사시스템이다.

  • PDF

Method of PCB Short Circuit Detection using SURF (SURF를 이용한 PCB 쇼트-서킷 검출 방법)

  • Hwang, Dae-Dong;Shin, Si-Woo;Lee, Keun-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5471-5478
    • /
    • 2012
  • In this paper, we propose a new short-circuit detecting method which can detect bad short-circuits, one of bad types occurring in PCB(Printed Circuit Board), by using SURF(Speeded-Up Robust Features) algorithm. The basic procedure in the proposed method sequentially consists of extracting features from both sample and inputted images by SURF, performing perspective transform by feature matching and matching results, extracting check areas of interest, binary coding and extracting short-circuits, and verifying results. The proposed method focuses on the robustness which can detect bad short-circuits even though the position and angle of PCB are not uniform and arbitrarily placed. Experimental results show that our method enables to detect bad short-circuits regardless of the location and angle of PCB placed variously and validate that the proposed method outperforms the conventional methods detecting bad short-circuits manually on the aspect of both the detection rate and time.