• Title/Summary/Keyword: 건 봉합술

Search Result 63, Processing Time 0.033 seconds

Effects of Knee Position during the Graft Fixation of the Arthroscopic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Graft (이식 건 고정 시 슬관절 위치가 자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 후 결과에 미치는 영향)

  • Lee, Churl-Woo;Yoo, Jae-Doo;Roh, Kwon-Jae;Park, Seong-Pil
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.143-147
    • /
    • 2005
  • Purpose: In case of anterior cruciate ligament (ACL) reconstruction, graft tendon is generally fixed in tibial tunnel with knee extended. When reconstructing ACL using hamstring tendon, the authors aim to find out the effect of knee joint position during graft fixation on postoperative knee joint stability and range of motion. Materials and Methods: Prospective study was done on patients who have undergone ACL reconstruction using hamstring tendon from May 2002 to January 2003 We used Rigifix system (Mitek Product, Johnson and Johnson, USA) and Intrafix system for fixation. Thirty nine patients received ACL reconstruction during this period. Excluding 2 patients lost in the follow-up, 37 patients were analyzed. The mean follow-up period was 14 months $(13{\sim}25months)$. Knee position was decided alternatively without any bias. Clinical evaluation was based on Lachman test, pivot shift test, Lysholm score, IKDC(international knee documentation committee) assessment and side to side KT-1000 maximal manual arthrometer difference. Results: After the last follow-up, average postoperative Lysholm score was 93.1 poins(65-98points). According to IKDC score, 26 cases were normal, 10 cases were nearly normal, 1 case was abnormal and we had no case of severe abnormality. The mean difference from the normal side was 2.5 mm under maximal manual loading KT-1000 arthrometer. According to postoperative Lachman test, 32 cases were normal,2 cases were grade I and 1 case was grade II. There were 34 cases of normal, 2 cases of grade I and 1 case of grade II. When using maximal manual KT-1000 arthrometer side to side difference, the difference from the normal side while fixing the tibia at 20'knee flexion was 2.3 mm and at full extention the difference was 2.7 mm. The range of motion at postoperative 1 year showed 5 degree flexion contracture in 1 case at 20 degrees knee flexion and 10 degrees of flexion limitation was observed in 2 cases at full extension. Conclusion: When ACL reconstruction using autogenous hamstring tendon, anterior laxity showed no difference in its stability between two groups. Tibial side fixation at full extension may be helpful in preventing flexion contracture due to overconstrained graft tendon.

  • PDF

Patterns of Retear After Repair of the Rotator Cuff - MRI Analysis of 109Cases - (회전근 개 봉합술 후 발생한 재파열의 양상 - 109예의 자기 공명 영상 검사 분석 -)

  • Tae, Suk-Kee;Kim, Young-Sung;Lee, Ho-Min;Park, Pan-Kun
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.16-24
    • /
    • 2012
  • Purpose: This study was designed to investigate the rate of incidence, location and the clinical value of the rotator cuff retear by analyzing MRI scans, which was taken after an arthroscopic rotator cuff repair. Materials and Methods: This study included a total of 109 patients, who underwent a shoulder MRI scan after an average of 10.6 months later from the arthroscopic rotator cuff repair. We only defined the 'retear' when the Sugaya type IV and V was observed in the sagittal section of the MRI. The location of the retear was divided into the medial and lateral areas by the site, which was 1 cm medial to the anchor insertion. We investigated the incidence rate and the location of the retear, in terms of the age, sex, initial tear size and the suture method. Also, we compared the functional score of the retear group and the non-retear group, after an average of 13.9 months follow-up. Results: There were 38 of the 109 patients that showed the rotator cuff retear. Of these patients, 25 were male patients, and 13 were female patients. Of the 38 patients with the rotator cuff retear, 21 patients were included in the <3 cm retear group, and 17 were included in the ${\geqq}3$ cm retear group. At the end of the follow up period, all 109 patients showed a statistical significant improvement in the shoulder functional score. Conclusion: According to the follow up of the MRI scan, which was taken after the rotator cuff repair, the retear rate reached 34.9 %, and there were no significant differences on the age and the suture method. More rotator cuff retear occurred in male patients, and the initial tear size was positively correlated with the incidence rate of the rotator cuff retear. Also, the retear was more frequently observed at the medial side. That is because when the suture was performed, excessive tension was loaded on the medial side of the suture site.

Simultaneous Acute Rupture of Anterior Cruciate Ligament and Patellar Tendon - A Case Report - (전방십자인대 및 슬개건 급성 동시 파열 - 1예 보고 -)

  • Kim, Yeung-Jin;Kim, Tae-Kyun;Yang, Hwan-Deok;Kim, Hyoung-Jun;Park, Jin-Young;Seo, Kwang-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.103-107
    • /
    • 2006
  • Simultaneous acute rupture of the anterior cruciate ligament (ACL) and the patellar tendon is a very unusual injury. That is difficult to diagnose in initial evaluation of knee injury, because the patellar tendon rupture is often missed. We report a 26 year-old male patient who was treated with ACL reconstruction using achilles allograft and direct patellar tendon repair with achilles allograft augmentation. The patient had the stable knee and full range of motion. It's clinical results were excellent(Lysholm score 93, Tegner activity score 6).

  • PDF

Mid-term Results of Biceps Incorporating Suture Without Deteaching the Biceps Tendon from the Flenoid in the Large or Massive Cuff Tear (회전근 개 대파열 및 거대 파열에서 상완 이두 근 장두를 포합한 회전근 개 봉합술의 중기 추시 결과)

  • Ji, Jong-Hu;Park, Sang-Eun;Kim, Young-Yul;Kim, Weon-Yoo;Kewon, Oh-Su;Jang, Dong-Gyun;Moon, Chang-Yun
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.104-111
    • /
    • 2008
  • Purpose: The aim of this study is to analyze the clinical results of using the technique of rotator cuff repair without parting the biceps long head from the glenoid for large or massive tear of the rotator cuff. Material and Methods: Form January 2005 to January 2007, we performed the arthroscopic biceps repair with incorporating suture to the rotator cuff for 21 patients with large or massive rotator cuff tear. The mean follow up period was 23 months (range: 6-48months). The number of males and females was 9 and 13, respectively. The age distribution ranged from 47 to 73 years with a mean age of 60.3 years. We compared the preoperative score with the postoperative scores using the University of California Los Angeles (UCLA) score, the shoulder index of the American Shoulder and Elbow Surgeons (ASES) and a simple shoulder test (SST). Results: The improvement in the VAS, ASES and the UCLA and SST scores was statistically significant at the final follow up (average follow-up 23 months) (p>0.05). Two of nine cases were found to have partial tear with continuity but seven cases were found to have complete tear according to the ultrasonography and MRI. Conclusion: The technique of rotator cuff repair without parting the biceps long head from the glenoid for large or massive tear of the rotator cuff is considered to be recommendable.

Arthroscoic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Gratt - Effect of the Additional Fixation after Fixation of the Graft with Intrafix - (자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 - INTRAFIX system을 이용한 경골부 고정 후 부가적 고정의 효과 -)

  • Yoo, Jae-Doo;Roh, Kwon-Jae;Shin, Sang-Jin;Yoon, Jong-Suk;Yeo, Sung-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.1
    • /
    • pp.51-55
    • /
    • 2005
  • Purpose: To compare the stability and clinical result after anterior cruciate ligament reconstructed knee after graft fixation using Intrafix in tibial tunnel with or without additional tibial post fixation. Materials and Methods: We analyzed 37 cases which were treated with four-strand hamstring tendon autograft during the period from May 2002 to January 2003. The grafts were fixed with Rigidfix system (Mitek Product, Johnson and Johnson, USA) in femur tunnel and Intrafix system (Mitek Product, Johnson and Johnson, USA) in tibial tunnel. After tibial fixation, additional tibial post fixation was done, which was determined by the serial case number prospectively. Patients were followed for average of fourteen months(range, thirteen to twenty-five months) At the time of final follow-up, patients were evaluated in terms of Lachman test, pivot shift test, Lysholm scores, IKDC (International Knee Documentation Committee) assessment, side-to-side KT-1000 maximum-manual arthrometer differences. Results: At last follow-up, Lysholm score was average 93.1(range: 65 to 98), IKDC assessment revealed that 26 cases had score of A, 10 cases had score of B and 1 case had score of C. The average maximum-manual KT-1000 arthrometer side ?to-side difference was 2.5 mm$(0{\sim}6mm)$. There was one case in which the Lachman test was graded as 2+ and four cases in which the Lachman test was graded as 1+ and the remaining thirty-two cases were normal by Lachman test. One case had a 2+ pivot-shift, and 2 cases had a 11 pivot-shift. The remaining 34 knees were normal on pivot -shift testing. The average maximum-manual KT-1000 arthrometer side-to-side difference was average 2.8 mm$(0{\sim}6mm)$ in Intrafix only group and average 2.2 mm$(0{\sim}4mm)$ in additional fixation group (P>0.05). Conclusion: Without additional tibial fixation, the stability of the anterior cruciate reconstructed knee with hamstring graft which was fixed with Intrafix was restored.

  • PDF

Risk Factor for Poor Clinical Outcome in Patients with Retear after Repair of the Rotator Cuff (회전근 개 파열 봉합술 후 재파열 환자에서 불량한 임상 결과의 원인 인자)

  • Lee, Hee Jae;Joo, Il Han;Hur, Jeong Min;Oh, Hyun Keun;Lee, Bong Gun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.61-67
    • /
    • 2021
  • Purpose: To evaluate the prognostic factors affecting poor functional outcomes in patients with retear after rotator cuff repair. Materials and Methods: From January 2013 to December 2018, among 631 patients who underwent arthroscopic repair of a rotator cuff tear, 42 patients, who could be followed-up for more than one year and showed a retear of the repaired cuff on magnetic resonance imaging (MRI), were collected retrospectively. The preoperative demographic data, range of motion, American Shoulder and Elbow Surgeons (ASES) score, fatty degeneration, and tear progression on postoperative MRI, as well as other factors that could affect the clinical outcomes, were analyzed. Patients who scored <80 points on the ASES score were allocated to the poor function group. The risk factors for poor clinical outcomes were compared with the group with ASES scores of 80 or above. Results: The postoperative functional results in the group with retear (n=42) after arthroscopic rotator cuff repair showed significant improvement. Univariate analysis revealed the preoperative visual analogue scale (VAS) score and tear progression to have associations with a poor shoulder function. In addition, subscapularis repair was found to be associated with a good shoulder function. The preoperative VAS score and tear progression except for subscapularis repair were independent factors associated with poor clinical outcomes according to multivariate logistic regression analysis. Conclusion: In patients with retear after rotator cuff repair, the preoperative VAS and tear progression in postoperative MRI are factors predicting a poor functional outcome.

Repair of Large to Massive Rotator Cuff Tears in the Elderly Patients (65세 이상 고령 환자의 대형 및 광범위 회전근 개 파열에 대한 봉합술)

  • Jung, Hong Jun;Chun, Jae Myeung;Jeon, In-Ho;Kwon, Jun;Ha, Sang-Ho;Yang, Sung Wook;Lee, Ji-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Purpose: The objective of this study is to evaluate the functional outcome and identify prognosis of retear patients in patients aged 65 years or over undergoing surgical repair for a large to massive full-thickness rotator cuff tear. Materials and Methods: From 1995 September to 2010 March, 147 patients aged 65years or over (40 male, 107 female, with an average age of 69.6) undergoing surgical repair for large to massive full thickness rotator cuff tear (large 67 cases, massive 80 cases). For functional evaluation, preoperative and postoperative 1 year range of motion and muscle power checked. For subjective evaluation, American shoulder and elbow surgeons score and Constant score were checked. For anatomical evaluation, 87 patients were checked shoulder MRI at the time of the postoperative 1 year. Results: ASES score improved from to 50.4 to 88.9, Constant score improved from 47.1 to 75.2. Supraspinatus power improved from 51.1% to 80.8%, external rotator muscle power improved from 64.5% to 83.1%. Forward elevation improved from 117.4 degrees to 153 degrees, external rotation improved from 23.6 degrees to 41.8 degrees. Follow up MRI showed re-tear in 23%, all re-tear patients were from massive tear except one patient. All re-tear patients showed improved clinical outcomes, but supraspinatus and external rotator muscle power were not improved. Conclusions: Patients aged 65 years or over undergoing surgical repair for a large to massive full-thickness rotator cuff tear showed successful outcomes over 90 percent. Re-tear patients also showed successful clinical outcomes. In elderly patients with large to massive full thickness rotator cuff tear, aggressive surgical repair leads good clinical outcomes.

Minimal-incision tenorrhaphy in flexor tendon injury (굴곡건 손상에서 최소절개 건 봉합술)

  • Jang, Ju Yun;Oh, Sang Ah;Kang, Dong Hee;Lee, Chi Ho
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.516-518
    • /
    • 2009
  • Purpose: To retrieve the retracted flexor tendon, additional incision and wide dissection are conventionally required. We introduce minimal - incision tenorrhaphy using 1 cm - length incision and minimal dissection. Methods: Transverse incision about 1 cm - length is made over the level of retracted tendon. Nelaton's catheter is advanced into tendon sheath from distal primary laceration wound to emerge proximally through the incisional wound. Catheter is sutured to proximal tendon in end - to - end fashion. By gently pulling the catheter, retracted tendon is delivered to distal wound. Tenorrhaphy with core suture and epitendinous suture is then carried out. Results: This retrieving technique provides minimal incision, minimal dissection, minimal bleeding, minimal injury to tendon end, and shorter operation time with preservation of vincula tendinum and pulley system. Conclusion: In case of flexor tendon rupture with retraction, this operative method is believed to allow reliable and effective tenorrhaphy and excellent postoperative outcomes.

Minimally Invasive Surgery with Tenorrhaphy for Postoperative Hallux Varus Deformity Combined with Flexor Hallucis Longus Rupture after Hallux Valgus Correction: A Case Report (무지외반증 교정술 이후 합병된 무지내반증과 병발한 장무지굴건 파열에 대한 최소침습적 수술 및 건 봉합술: 증례 보고)

  • Nam, Bum Joon;Suh, Jin Soo;Choi, Jun Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.2
    • /
    • pp.102-106
    • /
    • 2020
  • A postoperative hallux varus deformity is a dreaded complication of hallux valgus surgery. Several surgical options have been introduced to overcome this problem. This paper reports an uncommon case of a 68-year-old female patient who presented with a postoperative hallux varus deformity combined with a rupture of the flexor hallucis longus (FHL) tendon. She was treated successfully by a minimally invasive correctional osteotomy with open tenorrhaphy. With experience in treating this complicated case, it was noted that FHL could be transected during the trans-articular adductor tenotomy. Hence, extra caution is needed when the degree of hallux valgus deformity is excessive. To the best of the author's knowledge, correctional valgization osteotomy for a postoperative hallux varus deformity in a minimally invasive manner has not been reported. This case report is expected to benefit surgeons and their patients with severe hallux valgus deformity.

A Suture Bridge Transosseous-Equivalent Technique for Bankart Lesions with Deficient Bony Stability - Technical Note - (골안정성 결손을 가진 Bankart 병변에 대한 경 골-유사 교량형 봉합술식 - 술기 보고 -)

  • Choi, Chang-Hyuk;Kim, Shin-Kun;Chang, Il-Woong;Chae, Sung-Bum
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.179-182
    • /
    • 2009
  • Purpose: Point fixation at the margin of the glenoid is a limitation of conventional arthroscopic stabilization using suture anchors, and does not afford sufficient footprint healing, especially in glenoid bone deficiency. So, we introduce an arthroscopic suture bridge transosseous-equivalent technique for bony Bankart lesions to avoid the technical disadvantage of point contact with anchor fixation and to improve mechanical stability through cross compression of the labrum. Surgical approach: The technique was adapted from the transosseous-equivalent rotator cuff repair technique using suture bridges, which improved the pressurized contact area and mean pressure between the tendon and footprint. After preparation of the glenoid bed by removal, reshaping, or mobilization of the bony lesion, two anchors (3.0 mm Biofastak, $Arthrex^{(R)}$, Naples, FL) were inserted into the superior and inferior portion of the bony Bankart lesion. Using a suture hook, medial mattress sutures were applied around the capsulolabral portion of the IGHL complex to obtain sufficient depth of glenoid coverage. A 3.5 mm pushloc anchor ($Arthrex^{(R)}$, Naples, FL) hole was made in the articular edge of the anterior glenoid rim. distal, suture bridge was applied, and proximal was inserted to mobilize the labrum in the proximal direction. This avoided the technical disadvantage of point contact with anchor fixation and decreased the level of gap formation through cross-compression of the labrum.

  • PDF