Local Buckling of Built-up Square Tubular Compression Members Fabricated with HSA800 High Performance Steels under Concentric Axial Loading (중심압축력을 받는 건축구조용 고성능강(HSA800) 용접 각형강관 압축재의 국부좌굴)

  • Yoo, Jung-Han;Kim, Joo-Woo;Yang, Jae-Keun;Kang, Joo-Won;Lee, Dong-Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.435-442
    • /
    • 2012
  • Recently, high performance(strength) steels have been utilized to structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper is a series of basic study for the design specification of structural members using high performance steel, material properties of high performance rolled steel building structures. HSA800 was compared with the requirements of Korean Standards(KS) for HSA800. Welded square tube stub columns with variables of width-to-thickness ratios are planned in order to investigate the local buckling behaviors and check the current design limit of width-to-thickness ratio and uniaxial compressive tests are carried out. In addition, the local buckling behaviors of stub columns obtained finite element analysis were compared with those of test results.

A Study on Compressive Strength of Built-up H Shaped Columns Fabricated with HSA800 High Performance Steels (건축구조용 고성능강(HSA800) 용접 H형단면 기둥의 압축강도에 관한 연구)

  • Kim, Tae Soo;Lee, Myung Jae;Oh, Young Suk;Lee, Kang Min;Kim, Do Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.627-636
    • /
    • 2012
  • Recently, high performance(strength) steels have been utilized to structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper is a series of basic study for the design specification of structural members using high performance steel, material properties of high performance rolled steel building structures; material properties of HSA800 steel was compared with the requirements of Korean Standards(KS) for HSA800. Welded H-shape stub columns with variables of width-to-thickness ratios are planned in order to investigate the local buckling behaviors and check the current design limit of width-to-thickness ratio and uniaxial compressive tests are carried out. In addition, the buckling behaviors of stub columns obtained finite element analysis were compared with those of test results.

Changes in Insulation Performance of Organic Insulating Materials for Building Construction by Accelerated Durability Test Conditions (가속내구성 조건에 따른 건축용 유기계 단열재의 단열성능 변화)

  • Lim, Soon-Hyun;Lee, Gun-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.595-601
    • /
    • 2016
  • The insulation performance of the insulation currently used in building structures is reflected only during design based on initial performance and the reduction in heat insulation performance due to the degradation of long-term durability is not reflected. This study reviewed the degradation of heat insulation performance due to the durability degradation of insulating materials through the accelerated durability test. The study findings showed that the foamed polystyrene insulation bead method did not show performance degradation due to aging in the standard environmental condition and laboratory accelerated test condition but the performance is degraded in the freeze-thaw test condition. On the other hand, in the case of the extrusion method, the degradation of the heat insulation performance was less in the freeze-thaw test condition, but the rapid performance degradation was caused by the release of the internal gas at the beginning of aging. In addition, the hard polyurethane foam insulation showed better initial insulation performance than other insulation materials, but the performance was found to be degraded somewhat under laboratory accelerated test conditions and freeze-thaw test conditions.

Suggestion of Load and Resistance Factored Design Value for PHC Bored Pile (PHC 매입말뚝의 하중저항 설계정수 제안)

  • Park, Jong-Bae;Park, Yong-Boo;Lee, Bum-Sik;Kim, Sang-Yeon
    • Land and Housing Review
    • /
    • v.3 no.3
    • /
    • pp.279-286
    • /
    • 2012
  • The limit states design method is replacing the allowable stress design method worldwide, e.g. the design code of ISO and various construction codes of Korea are adopting the reliability based limit state method. This paper proposed LRFD design value which is one of limit states design method for the PHC bored pile used as building foundation. This paper analysed 81 load test results and the bearing design(Meyerhof method & SPT-CPT conversion method), and proposed LRFD value for each design reliability Index 2.33 and 3.0 for PHC bored pile. LRFD value of PHC bored pile represents 0.36~0.44 for Meyerhof method and 0.24~0.31 for SPT-CPT conversion method according to the deign reliability index.

Hybrid Prototype of Performance and Prescriptive Specifications in Curtain Wall Construction (커튼월 공사의 성능·사양 연계 시방서 프로토타입)

  • Lee, Jun-Ho;Cho, Dong-Hyun;Koo, Kyo-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.5
    • /
    • pp.433-442
    • /
    • 2014
  • The most design criteria and specifications in Korea utilized to ensure appropriate quality are based on process and prescriptive criteria determining materials, measure and methods. It has many problems including a loss of competitiveness resulting from inhibited creativity of the contractors. The performance-based specifications focused on final product are being proposed, but have difficulty in adapting to the architectural field. In this study the hybrid specification prototype for curtain wall construction was suggested. The specification framework was presented through analysis of linkage between the performance and prescriptive specification cases. Based on the survey with practitioners, the performance inspection process and the sample specification were developed by identifying the essential performance test timings. The applicability of the specification prototype was evaluated by interviews with experts. It was found that the prototype was active and a progressive supporting tool which could support to secure phased performance during construction as well as final performance.

Fire Resistance Performance Test of High Strength Concrete by Type of Mineral Admixture (혼화재 종류에 따른 고강도 콘크리트의 내화성능 평가)

  • Kwon, Ki-Seok;Ryu, Dong-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.6
    • /
    • pp.597-605
    • /
    • 2015
  • The method of concrete mix design used in this study aims to achieve the identical specified design strength, applying different types and replacement ratio of mineral admixtures and afterwards, fire tests were conducted using the standard time-temperature curve specified in the ASTM E119 to identify the influences of the types of mineral admixtures on the fire resistance performance of high strength concrete(HSC). The least spalling was observed in the test specimen containing blast furnace slag as a partial replacement of cement, while the most significant spalling phenomena were observed in the blast furnace slag test specimen that silica-fume was added in. In particular, the reasonable volume of spalling was observed when solely replaced by silica fume. However, the influence of the cement replacement by silica fume and blast furnace slag on the increases of spalling can be explained through blocked pores by the fine particles of silica fume, leading to decreases in permeability.

A study on quantitative risk assessment for railway Tunnel fire (철도터널에서 차량화재시 정량적 위험도 평가에 관한 연구)

  • Yoo, Ji-Oh;Nam, Chang-Ho;Jo, Hyeong-Je;Kim, Jong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.4
    • /
    • pp.307-319
    • /
    • 2010
  • As we learned in Daegu subway fire accident, fire in the railway tunnel is prone to develop to large disaster due to the limitation of smoke control and smoke exhaust. In railway tunnel, in order to ensure fire safety, fire prevention and fighting systems are installed by quantitative risk assessment results. Therefore, in this research, developed the program to establish quantitative risk assessment and suggested quantitative safety assessment method including fire scenarios in railway tunnel, fire and evacuation analysis model, fatality estimate model and societal risk criteria. Moreover, this method applys to plan preventing disaster for Honam high speed railway tunnel. As results, we presented the proper distance of escape route and societal risk criteria.

BIM-based Repair&Replacement (R&R) Cost Estimating Process (BIM기반 건축물 수선교체비 산정 프로세스)

  • Park, Jieun;Yu, Jungho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.2
    • /
    • pp.31-38
    • /
    • 2016
  • In a construction project, the portion for maintenance costs for a building is considerable compared to the initial construction cost. As such, Life Cycle Cost (LCC) analysis is being increasingly utilized to assess the design value of engineering work in Korea. Additionally, the Public Procurement Service in Korea announced that it will be mandatory for all domestic construction projects to adopt BIM. Furthermore, the paradigm for architectural design has shifted from 2D to 3D, and to BIM, which includes a data management system. Within this background, however, there is currently no adequate BIM-based LCC analysis software and the requirements of cost estimation for repair and replacement cost for a building is not completely adequate in BIM tools such as Revit and Archicad. Therefore, this study suggests a process of cost estimation for repair and replacement (R&R) cost based on IFC data. First, we analyzed existing R&R criteria and defined BIM-based requirements when calculating R&R costs. These requirements were extracted from relevant IFC data. Subsequently, this was saved to a database and a BIM-based database was built for R&R cost estimation. Finally, this database was connected with external databases such as R&R Criteria DB and Cost Information DB to calculate R&R costs. This process is expected to improve upon the traditional process of cost estimation of R&R cost by applying a BIM model. The proposed process can contribute to a further standardizing of BIM-based LCC analysis thru application to initial construction costs, energy costs, and other maintenance costs.

A Vibration Evaluation and Improvement Scheme for Open Test Blasting (노천시험발파의 진동평가와 개선방안)

  • Kim, Eung-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.310-315
    • /
    • 2017
  • Although studies evaluating the effects of the blasting vibration on the adjacent structures from various angles have continued, cases of securing the safety of the adjacent buildings and researching the proper blasting method for the field condition by analyzing the vibration waveform of the measuring field while performing the open pit blasting are poor. Therefore, it is necessary to present a remedy for blasting pattern selection through test blasting that is appropriate for field conditions, and is economical and efficient. In this study, open pit blasting work was conducted based on the separation distance applied according to the standard blasting method by test blasting and the vibration regulation standard in the road expansion construction site to measure the blasting vibration value, and the vibration prediction equation by blasting methods was examined using a regression analysis computer program to calculate K, N, and R of the confidence level 95%. By setting the blasting allowed vibration standard of the test blasting target area to 0.3cm/sec, and the charring weight and blasting method by the separation distances according to the blasting vibration estimation equation of the open pit blasting guideline and the blasting vibration estimation equation of the test blasting were compared/analyzed, it was possible to identify the factors that increased the working expenses. In addition, the measurement and analysis of the adjacent structures during open pit blasting and the blasting vibration were performed after selecting the most adjacent structure to the open pit blasting spot to analyze the problems on the test blasting procedure and analysis method in the open pit blasting design/construction guidelines, which appeared in the process of completing open pit blasting construction, and a remedy is presented.

Analysis of Civil Defense Shelters and Measures (민방위 대피소의 실태분석 및 대책방안)

  • Kim, Tae-Hwan
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.31-31
    • /
    • 2011
  • 1990년 이후 공산체계인 구소련과 동구권이 몰락하고 세계적으로 탈냉전의 변화와 우리의 민주정부 수립 후 햇빛정책 등에도 불구하고 북한은 적화통일을 포기하지 않고 작년 11월에 연평도에 포격을 가하여 민간인과, 군이 2명이 사망하는 사건이 발생 하였다. 또한 북한의 공격은 과거의 포탄공격뿐만 아니라 미사일이나 화생방과 같은 생화학물질 탑재 가능한 공격이 예상된다. 이에 대비 정부에서는 고정시설의 화생방 방호는 일단유사시에 국민의 생명과 재산을 보호하는데 필수요소로서 집단보호개념에 도입하고 있으며, 현재 각 중요 대피시설 및 지자체의 기존 대피시설을 개인방호, 탐지, 제독, 운용절차를 포함한 실태파악 및 재래식 탄을 포함한 통합적인 조치를 마련하고 있다. 작년 2010년 11월 연평도에서의 북한 포격이후 우리는 서해5도나 접경지역 주민과 그리고 근접거리의 서울시민들이 안전하게 포격으로부터 피난 할 수 있는 민방위대피소에 대한 문제점이 대두되고 대책방안을 요구하고 있다. 소방방재청 기준에 따르면 직격(直擊) 핵폭탄을 제외한 화생방, 재래식 무기 공격에 견딜 수 있는 시설은 '1등급 대피시설'인데 서울에는 한 곳도 없다. 고층건물의 지하 2층 이하나 지하철, 터널 같은 2등급 대피시설도 폭격은 견딜 수 있지만 화생방 공격에는 취약하다. 지하상가 등 건축물의 지하층, 지하차도나 보도는 그보다 더 취약한 3등급이며 단독 주택의 지하층처럼 방호 효과가 떨어지는 곳이 4등급이다. 2등급으로 분류된 대피소의 경우 분류만 되어 있을 뿐 장기간 대피시 시민들이 사용 할 수 있는 거주공간이 아닌 임시 대피로서의 역할만 하고 있다. 본 연구에서는 민방위 기본법에 따라 지하에 $3.3m^2$ 당 4명 이상이 대피할 수 있는 규모의 공간을 갖추기만 하면 대피시설로 볼 수 있는 현 문제점과 1등급에서 4등급으로 나뉘어져있는 민방위 대피소와 대피소가 있지만 피난공간으로서의 역할과 구조적으로 안전한가에 대한 국내외 실태 분석을 통하여 분석한 결과 우리는 서해5도 대피시설의 반 이상이 무용지물이고 접경지 또한 피난시에 피난장으로서의 대피소가 난방이나, 구급품과 식구 시설 등이 구비가 되어 있지 않고 대피시설로 지정한곳이 간판이나 안내시설이 없다. 외국의 경우 스위스는 연방정부의 관리책임으로 전쟁이나 핵 확산에 따른 화생방 업무 전담팀을 두고 있으며, 방독면은 개인 방호물자로서 전국민 100% 보유하고, 각가정이나 건축, 시설물의 경우 화생방 표준 대피시설 설치관련 규정 마련 시행하고 있다. 대피시설은 화생방 방호가 가능한 지휘부용 대피시설과 일반 주민대피용 시설을 구분하여 설치운영하고 있으며, 전국에 650만개를 설치하고 있다. 결론은 대피시설이 북한 공경시 피난시설로의 활용방안을 모색 등급구분에 따른 현실적용 수정과 기존 대피소 보강과 재선별이 필요하고, 신축시 설계 표준설계안 그리고 기존의 대피소에 대한 보수, 보강방법 가이드라인과 장기간 거주에 대한 설비구축 등과 국민 대홍보등을 제안하였다.

  • PDF