Antimicrobial Coating Agent (항균 코팅제)

  • Ko, Jong-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.96-115
    • /
    • 2013
  • This article describes the concept and the trend of antimicrobial coating agents, which will help to establish the direction of the research and development on antimicrobial coating agent. Antimicrobial agents are compounds that inhibit or kill microorganisms. They are classified into inorganic, metallic, low molecular weight organic, natural organic, and polymeric compounds. Antimicrobial coatings are applied to the surface of daily necessities, medical devices, industrial products, electrical appliances, fabrics, and interior building materials, etc. Conventional antibiotics penetrate microbes without damaging bacterial cell walls, leading to drug resistance which polymeric antimicrobials can prevent by disrupting cell walls. Most polymeric antimicrobials are focused on cationic polymers. Improvement in the selectivity and durability of antimicrobials and reduction of their toxicity will come true by more reasonable design of molecular structures and their combination in coating system.

A Study of Structural Safety Diagnosis using Frequency Domain Analysis of Impact-Echo Method (충격반향기법의 주파수영역 해석을 이용한 구조물 안전진단에 관한 연구)

  • 안제훈;서백수
    • Tunnel and Underground Space
    • /
    • v.14 no.1
    • /
    • pp.35-42
    • /
    • 2004
  • Impact-echo is a method for non-destructive testing of concrete structure. This method is based on the use of impact-generated stress wave which is propagated and reflected from internal flaws within concrete structure and external surface. In this study, we performed non-destructive testing using impact-echo methods for safety diagnosis of civil engineering and building structures. There are testing cases for the three models having one-dimensional form ; The first case is the measurement of thickness change of the model, the second is the detection of cavity in the model, and the third is the predictions of the lining thickness and the position of the cavity under tunnel lining condition.

$Cu(In,Ga)Se_2$ 박막 태양전지 제작을 위한 폴리이미드 기판의 열분석 및 후면전극 특성 분석

  • Park, Su-Jeong;Jo, Dae-Hyeong;Jeong, Yong-Deok;Kim, Je-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.593-593
    • /
    • 2012
  • CIGS 박막 태양전지는 일반적으로 soda-lime glass(SLG)를 기판으로 사용하여 SLG/Mo/CIGS/CdS/ZnO/ITO/Grid의 구조로 제작된다. 하지만 SLG를 기판으로 사용할 경우, 유리의 특성상 무게가 무겁고, 유연성이 없기 때문에 건축물 적용에 적합하지 않다. 이러한 문제점을 극복하기 위해 가볍고 유연한 금속 및 폴리이미드 기판을 이용한 CIGS 태양전지가 널리 연구되고 있다. 그러나, 폴리이미드 기판의 경우, 특성이 우수한 CIGS 박막을 얻기 위한 고온 공정을 사용할 수 없기 때문에 이에 대한 고려가 필요하다. 본 논문에서는 CIGS 박막 태양전지 제작을 위한 폴리이미드 기판의 특성과 그 위에 형성한 후면 전극의 특성을 논의하고자 한다. 4종류의 폴리이미드 기판에 대한 열 특성을 시차주사열량계(differential scanning calorimeter)와 열중량분석기(thermogravimetric analysis), 열기계분석기(thermo mechanical anaylsis)를 이용해 분석하였다. 또한 Mo 후면 전극을 DC-sputter를 이용해 형성한 후, XRD와 AFM, 4-point probe를 이용하여 결정성 및 표면 거칠기, 면저항을 분석하였다. 결정성과 거칠기는 SLG에 증착했을 때와 동일한 결과를 보였으며, 면저항은 폴리이미드 필름에 증착 할 경우 더 크게 측정되었다. 본 연구는 중소기업청 산연기술개발사업(SL122689) 및 과학기술연합대학원대학교(UST)의 지원을 받아 수행된 "공동연구 지원사업"의 연구결과입니다.

  • PDF

Study of the environmental assessment of heavy metals bearing slag utilization (중금속 함유 폐기물의 재사용을 위한 환경적 평가에 관한 연구)

  • Bae, Hae-Ryong;Gwon, Yeong-Bae;Moszkowicz Pierre
    • 연구논문집
    • /
    • s.28
    • /
    • pp.161-172
    • /
    • 1998
  • In the recycling industry, the recuperation of zinc from Electric Arc Furnace dust by the Waelz process generates important quantities of slag. This slag presents good mechanical properties, and for the most siliceous slag. a high stability which would enable its use by total or partial substitution of certain granulates in civil engineering Our study (within the framwork of a European programme cofunded by the European Commission-DGXII) concerns the physico-chemical and mineralogical characterization and leaching behaviour of several types of Waelz slag. The leaching tests are regulatory tests and specific characterization tests of leaching behaviour. They take into account the influence of several main parameters of the valorization scenarios envisaged for the slag(e.g. pH, Redox potential, chemical nature of the leachant, type of contact-liquid/ solid etc.).

  • PDF

특집 - 산업디자인 발전 및 경쟁력을 위한 우수디자인

  • (사)한국포장협회
    • The monthly packaging world
    • /
    • s.215
    • /
    • pp.55-69
    • /
    • 2011
  • 우수디자인(GOOD DESIGN)은 산업디자인진흥법에 의거, 상품의 외관, 기능, 재료, 경제성 등을 종합적으로 심사해 디자인의 우수성이 인정된 상품에 GOOD DESIGN 마크를 부여하는 제도로 지난 1985년부터 시행하고 있다. 지식경제부가 주최하고 한국디자인진흥원이 주관하는 굿 디자인은 우수한 디자인상품을 선정 장려함으로써 상품의 디자인개발을 촉진하고 독창적이고 우수한 상품디자인을 개발하여 상품의 경쟁력 강화를 통한 수출증대와 국민경제 발전에 기여해 나가고 있다. 우수디자인(GOOD DESIGN)은 제품디자인, 포장디자인, 환경디자인, 커뮤니케이션디자인, 소재표면처리디자인, 건축디자인 패션디자인, 패션디자인 등의 부문으로 나뉘어 선정, 시상하고 있다. 포장디자인의 경우 우리 생활에 사용 및 유통되는 모든 포장상품으로 환경보호 측면과 폐기물 처리과정, 재활용성 등을 고려한 포장의 기능과 디자인이 우수한 상품을 중심으로 선정하고 있으며, 제과류, 화장품류, 의약품류, 주류, 음료, 농 축 수산물, 가전제품류, 생활용품류, 잡화 등 기타 유통 중인 상품을 대상으로 시상하고 있다. 매년 대통령상 1점을 포함해 국무총리상 2점, 대상(지식경제부장관상) 6점, 최우수상(조당청장상) 15점, 우수상(한국디자인진흥원장상) 25점이 선정되며, 특별상으로 국민참여 선정 굿디자인 상품에 대한 시상식도 있다. 또한 대통령상, 국무총리상, 지식경제부장관상을 수상한 상품의 주 디자이너 및 디자인팀을 대상으로 우수디자이너상도 시상하고 있다. 본 고에서는 지난 해 2010 우수디자인(GD)상품 455점 가운데 포장디자인 부분 수상작들을 살펴보도록 한다.

  • PDF

A Study on the Proper Quantity of Ventilation through Changing Floor Temperature in Sleeping (수면시 바닥표면온도에 따른 적정 환기량에 관한 연구)

  • Kim, Dong-Gyu;Lee, Sung;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Modern people are spending most of time in interior area. Indoor air environmental problem is one of the most effective factors influenceable to human health. Furthermore, saving energy and making ventilation system for pleasant indoor environment are necessary when it is faced shortage of energy over the world. In our country's case, it is already imposed that required quantity of air ventilation in buildings is 0.7 times per hour on "The regulation on building engineering system". As on the rise of the interests about Indoor air environment, Heat and Carbon dioxide emissions from User's metabolism, activity, furniture, and construction materials etc. could be the causes of Indoor air pollution. If these materials stays in Indoor air for so long, it could directly influence the user's health condition with a disease. As of building's sterilization improved that raised more mechanical ventilation. It also leads much energy waste in a period of high price of fossil fuel. Therefore, the way that saves energy and effective control of indoor ventilation is urgently needed. So, this study places the purpose on validating volume of indoor ventilation and user's comfortable degree by comparison CO2 emission rate through changing floor temperature.

The comparison of thermal characteristics of new Han-ok floor heating for applying modern On-dol system (현대 온돌 시스템 적용을 위한 신한옥 바닥난방의 열적특성 비교)

  • Lee, Tai-Gang;Lee, Ju-Yeob;Song, Min-Jeong;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.61-69
    • /
    • 2013
  • The experiment on thermal characteristics of on-dol systems were carried out to apply to New Han-ok's heating system. Change of surface temperature varied with heating times, distribution of surface temperature, radiation property were surveid on four on-dol system in laboratory conditions. Followings are results. 1) "Hwang-to unit" was most favorable condition of the distribution of floor surface temperature. And the results from reaching time to thermal comfort temperature of on-dol system showed that "Hwang-to unit" was the most favorable to continuance of floor temperature. 2) There were a little difference in surface floor radiations of $30^{\circ}C$ for three wet on dol-systems. 3) It was suggested that "Hwang-to unit" is the most appropriate to floor heating system of new han-ok considering eco-friendship and continuance of floor temperature in intermittent heating condition.

A Study on Representation Techniques of Visual Tactility in the Surface of Contemporary Architectutre (현대건축의 표면에 나타난 시각적 촉각의 표현기법에 관한 연구)

  • Jeon, You-Chang;Kim, Sung-Wook
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.3
    • /
    • pp.139-147
    • /
    • 2008
  • Modern architecture's optical mechanism focused on Ocuularcentrism neglects the tactility of vision and tends to eliminate the optical and tactile dualism of traditional spaces by representing spaces and surfaces that are abstract and cold-hearted. In other words, all sensory experiences, except for visual experiences, are eliminated to make it impossible to create the substantial core of architecture that combines time, image, and surface textures. The fast-changing social trends, the emergence of new materials and technologies, and the corresponding development of various types of media since the Industrial Revolution have changed the paradigm of human perception and representation. With the development of media, other sensory experiences besides visual experience have been stressed and human perception has converted from single perspective to complex perspective. In result, new sensory items, such as visual tactility, have replaced the traditional vision-centered hierarchy. The composition of architectural surfaces has represented the functional and commercial needs of technology, structure, as well as the socio-cultural needs of the community. In contemporary times, it is being changed and developed by the new tactility and the corresponding expression of modern architecture. Based on the visual representation of tactility of architectural surface, this study used a composition of surface that combines various events, meanings, and senses to examine how architecture can mediate and reproduce viewers' visual experiences and discover the existential relationship between architecture and men.

Comparative Performance Evaluation by Winter Apartment Temperature on the Outer Surface of the Insulation (동계 아파트 외표면 온도에 의한 단열성능 비교평가)

  • Park, Jung-Hun;Kim, Bong-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.91-100
    • /
    • 2013
  • This research is to measure and analyze the thermal performance of the apartment structure and to evaluate and establish standards of thermal insulation defect in order to make the basic data necessary for determining the degree of the thermal performance degradation and for repairing and reinforcing the exterior wall of the existing apartment. Furthermore, it is to predict the part of occurrence of the thermal bridge and condensation at the apartment building structure. On the other one hand, it is also to analyze the degree of thermal insulation performance according to the standards of thermal insulation and elapsed time, through the analysis by the workability of concrete.

Characteristics of Sound Insulation in Sandwich Plates with Orthotropic Skin Plate (이방성판을 사용한 샌드위치판의 차음특성)

  • Kang, Hyun-Ju;Kim, Bong-Ki;Kim, Jae-Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.853-856
    • /
    • 2004
  • This study presents a prediction method for sound insulation of sandwich plate which consists of orthotropic plates as skin and mineral wool as core. Prediction by classic theory, which considers orthotropic effects, requires considerably complex and cumbersome process and moreover many assumption. However, experimental results of the sandwich plate with orthotropic plates as skin show that the orthotropic effects are disappeared or fade out. Hence, predictions by using sandwich model are conducted by a simple modelling that substitutes an orthotropic plate into an equivalent flat plate. Comparative results show that sandwich model gives a good agreements with theoretical prediction.